Page 11
E-9 ENGLISH CLEAN ION SHOWER START • If the “Plasmacluster Ion ” is OFF, the plasmacluster ion will be not released. • When the operation fi nishes, the unit will return to the prior operation mode. It is possible to switch this mode to another while operating. However, the CLEAN ION SHOWER mode will not function after switching mode. PLASMACLUSTER ION ON/OFF FAN SPEED Select the desired fan speed. Releases high-density Plasmacluster ions and discharges strong air fl ow for 60 minutes. NOTE OFF...
Page 12
brighter darker turn off E-10 USEFUL FUNCTIONS High Standard Low LIGHT CONTROL Use this function to select the desired brightness. CHILD LOCK Operation of the unit display will be locked. It is the same method as starting operation. ON CANCELLATION SOUND INDICATOR SETTING The unit can be set to give an audible signal when the Water Tank is empty. (with the unit OFF) ON ADJUSTMENT OF SENSOR DETECTION SENSITIVITY 1 DUST MONITOR and ODOUR MONITOR is constantly red to reduce sensitivity, and set to “high” if...
Page 13
1 2 3 E-11 ENGLISH CARE AND MAINTENANCE CARE INDEX The Indicator Light will turn on after approximately 720 hours. (30days×24hours=720) Reminder to perform maintenance of parts below. After performing maintenance, reset the Filter Indicator. (Ref. E-12) Humidifying Filter (Ref. E-12) Humidifying Tray Cover (Ref. E-13) Water Tank (Ref. E-12) Humidifying Tray (Ref. E-13) Unit (Ref. E-14) HEPA Filter Cannot be cared. Deodoriziing Filter (Ref. E-14) HUMIDIFYING DISINSTALLATION frame colour : gray After...
Page 14
E-12 CARE AND MAINTENANCE WATER TANK Rinse the inside with a small amount of water. • Do not shake the Water Tank with holding the carrying handle. CAUTION NOTEfor stubborn dart... Tooth brushs Tank cap Clean inside of the water tank with a soft sponge and the tank cap with a cotton swab or a toothbrush. HUMIDIFYING FILTER Rinse with plenty of water. CAUTION • Do not remove the Humidifying Filter from a fi lter frame. • Avoid spilling water from the Humidifying Tray. NOTEfor stubborn dart... 1. Soak in...
Page 15
E-13 ENGLISH Back Panel HUMIDIFYING TRAY AND COVER CAUTION 1. Remove the Humidifying Tray Cover. 2. Rinse the inside of the Humidifying Tray and the Humidifying Tray Cover with a tooth brush. Be sure to remove the power plug from the wall outlet. • Do not remove the Float and the Roller. • If the Float and / or the Roller comes off. (Ref. E-17) NOTEfor stubborn dart... TRAY1. Fill the tray half way with water. 2. Add a small amount of kitchen detergergent. 3. Sork for 30 minutes. 4. Remove the...
Page 16
E-14 CARE AND MAINTENANCECARE AND MAINTENANCE 4 Dry fi lter completely in a well ventilated area. When possible, dry outdoors. (about 6 hours to dry out) • Avoid drying filter outdoors during inclement weather (e.g. rain or cold temperatures). • Do not allow filter to freeze. • If filter is dried indoors, take precautions, such as placing towels, etc under the filter to prevent water damage to the floor. 1 Remove the dust on the DEODORIZING FILTER. 2 Rinse the DEODORIZING FILTER with water. •...
Page 17
Replacement Filter Model Please consult your dealer for purchase of replacement filter. •HEPA fi lter About 10 years after opening •Deodorizing fi lter* About 10 years after opening •Humidifying fi lter About 10 years after opening Use the date label as a reminder for next replacement. E-15 ENGLISH Replacement timing Filter life will vary depending on the room environment, usage, and location of the unit. If dust or odour persists, replace the fi lter. (Refer to “Please read before operating your new...
Page 18
E-16 TROUBLESHOOTING SYMPTOM REMEDY (not a malfunction) Odours and smoke are not removed. • Clean or replace the fi lters if they appear to be heavily soiled. (Ref. E-11,E-12,E-14) The Front Monitor illuminates green even when the air is impure.• The air could be impure at the time the unit was plugged in. Unplug the unit, wait one minute, and plug the unit in again. The Front Monitor illuminates orange or red even when the air is clean.• Sensor operation is affected if the dust sensor openings...
Page 19
E-17 ENGLISH SYMPTOM REMEDY (not a malfunction) When the Roller / Float was removed. • Install the Roller / Float in order below. AUTO RESTART After a power failure, automatically resume the operation when the power recovers.Auto Restart can be set. • Even when the plug is unplugged or the breaker is thrown during the operation, the operation resumes at the previous operation mode and settings if the power recovers. FLOAT ROLLER 1. Insert the fl oat under this tab. 2. Inner the tab of fl oat into...
Page 20
E-18 TROUBLESHOOTING ERROR DISPLAY If error occurs again, contact the Sharp Service Centre. DIGITAL INDICATIONLAMP INDICATION ERROR DETAILS REMEDY Flashing of the Clean Air & Humidify Indicator Light.Abnormal humidity fi lter. Verify if the Humidifying Filter, Humidifying Tray and Water Tank are properly installed and then turn power ON again. Flashing of the Fan Speed Indicator Light .Abnormal fan motor. Turn power OFF to cancel the error display, wait one minute, and then turn power ON....