. POSTED 6-27-04 This manual is for reference and historical purposes, all rights reserved.This page is copyright @ by M. Butkus. NJ.This page may not be sold or distributed without the expressed permission of the producerI have no connection with any camera company Online camera manual libraryThis is the fulltext and images from the manual.This may take 3 full minutes for this PDF document to download. The r4ain page is located at www.butkus.org/chinon If you find this manual useful, how about a donation of $3 to:M. Butkus, 29Lake Ave., High Bridge, NJ 08829-1701and send your e-mail address so I can thank you.Most other places would charge you $7.50 for a electronic copy or$f8.00 for a hard to read Xerox copy. This will allow me to continue to buy new m:rnuals and pay their shipping costs.ItIl make you feel better, wont it?If you use Pay Pal or wish to use your credit card, use the Pay Pal Link on my page. If you found this page from any other location (other then a link)please notify me at [email protected]
COTPOTEilTS Lishr scote h?Jh 1;t, tii -!.| Needle ASA/DIN Diol Knob Arrow Poinler ASA/DlN Scole Shutter Speed Scole f/stop Scole CdS Cell High/Low Sliding Switch EV Scqle Incident Light Filter On/oe swirch
Boltery Check Button Zero Adjusting Screw Boltery Chqmber Neck-cord Holder SPECIFICATIONS Meosuring sysiem: Reflected light type(with built-in provision for incidentlight type)Accurocy +l/3 f/stopMeosuring ronge:High brightness: EV8-18(ASA100)Low brightness: EV-2-8(ASA l00lLight receiving ongle, Approx. 30o(re0ecfed light type)EV Scole : -6-23ASA Scole: 6-12,000DIN Scole: 9-42Aperture scole: Il1-64Shutter scole: 30 min.-l/4000 sec.Cine scole: 8-64 fpsColibrotion Constont : K: I .3C:25.5Size: 92 x 58 X 36mmWeight: 2l0g 3butkus.org/chinon
BETORE USI]IG SEKO]IIC APEX |. Zero Selting r The needle should indicote zero when the light is completely shut oft ihe meter held upright. To set the needle to the zero, remove the bottery ond slowly turn the zero odiusting screw on the bock of the meter while pressing the ON/OFF switch. 4 The meter requires o ,l.3 voli mercury bottery suchos Mollory PX-1 3, RM-625 or the equivolent,which norrnolly losts for obout o yeor ond o holf.Keep the bottery out of the meter when the meteris not in use in order to ovoid possible domogefrom corrosion of the bottery.To test the bottery for sufficient strengih, press theON/OFF switch ond olso the red button on thebock of the meier ot the some time ond see if theneedle swings up to ihe red mork on the scoleolote. 2, Mercury Botlery: :** 0:,. XOillCco..rro.i4AOT IN JAPAI{
tt:::Po lll u) ,.,: &:. HOW IO USE SEKO]IIC APEX l. Setting the Speed of Your Film: With thumbs of both honds, turn the knobs on thediol to show correct ASA (or DIN) number oligned with the block line by the ASA (DlN) Index Window. Rt0t620 3240 6880 125r60 250320 530640 r,000|,250 2,0002,500 4,0005,00 0 8,00 0i0,000
2.High or Low Brightness Ronge:3. Reoding lhe Scole: for High Ronge for Low Ronge Sliding Switch chonges meosuring ronge of brigt- ness. In dim condition, slide the switch fully to the right showing L mork on the frome for the low ronge. Oiherwise, keep the switch to the left with H mork to oppeor on the frome. lt is odvisoble olwoys to try the high ronge first unless it is very dork, ond switch to the low ronge only when ihe needle foils io defleci. 6 Aim ihe meter ot the subject ond press the ON/ OFF Switch Button to permit the needle to deflect ond indicote o certoin point on the light scole. Then, remove your finger off ihe button to lock the needle ond note the reoding on the scole. The figures on ihe upper side of the light scole froml to 1 1 following L ore for low brightness ronge to reod when the Sliding Bor Switch shows 1 os described in the preceeding porogroph. The figures on lhe lower side ore for high brightness ronge. for High Ronge
4. Colculotion of Exposure: !s,, K; Rotote ihe lorge knurled outer diol to show the reoding of the needle on the light scole iust under the Arrow Pointer on the diol. For exomple, if the needle indicoies I3 on the high ronge, with the ASA Index set ot I00, then, show this reoding (i3) right under the Arrow Pointer so ihot you con get ony combinotion of Shutter Speed ond {/Stop indicoted on the diols, for exomple, 11250 second ot f12. Any com- binotion of shutter speed ond f/stops opposite eoch other on the exposure conirol diol will give the some correct exposu re; 1 ll25 second, f/2.8 ; 1/60 second, ll4t 1130 second, f/5.6 etc. The combinotion you select depends on whether you wont o fost shutter speed (with its corresponding lower f/stop number) to stop oction occurring in the scene; or depth o{ field with o higher f/stop number ond its slower shutter soeed, ,.tJ l,l .t5 ,It c,!tP
5. The 2 ond I12 Position:6.Motion Pictures: L. The 2 ond 112 positions which represent obrightness rotio of 4 to I con be of greol voluein exposing for color ghots. Attempt to hove theprimory colors of interest foll between the 2 ond 1/2 positions for most foithful renderingof those colors. While most color films now hoveo lotitude thot exceeds this rotio, if the primorycolors foll within the 2 ond 112 positionsyou con then be ossured thot the bolonce of thescene will be properly exposed within the limits ofthe film you ore using.In cose of block ond white film, the point morked 112 provides o convenient woy of holving nor-mol exposure for flot scenes such os londscopeswhere there is no extreme controst between high-lights ond shodows. The point morked 2 pro-vides double normol exposure ond is used forscenes of very high controst such os bocklightedsubiects. In these instonces, set the light scole toeither 112 or 2 insteod of the orrow Dointer. 8 I lso Gps.) Meosure the light ond set the diol os instructedin the porogrophs 2-4. Cine speeds rongingfrom 8-64 fromes-per-second ore given in theshutter speed scole, os illustroted obove.Find the cine speed used by your comero ond reodthe corresponding figure on the f/stop scole. Thisis the proper f/stop for your comero. Stondord speed for Regulor-8 is l6 fps., ond forSuper-8 1 8 fps. \I
7. Reflected Light or Incident Light: Reflected light is light reflected from the subject to the comero. Incident light is the light which octuollyfolls on the subiect before it is reflected. Meosurement of either reflected or incident light con be usedto determine correct exposure.Sekonic Apex is bosicolly designed for reflected light, but con olso be converted to reod incident lightsimply by sliding the lncident Light Filter. ob0 a .( To toke incident light reoding, move the opoque,semi-circulor filter fully to the left covering theCdS cell. Hold the meter in the some olone osthe comero lens ond ooint the meter fowqrd thecamero. To toke reflected light reodings, slide the filter bock to the right, uncovering the CdS cell. Hold the meter in the some plone ond direction os the comero lens, ond point the meter loword lhe subiecl. 9