Home > Sanyo > Video Recorder > Sanyo Dsr 3716 P Manual

Sanyo Dsr 3716 P Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Sanyo Dsr 3716 P Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 550 Sanyo manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							English
    General settings
    How to set 70
    1Connect the RS-485 terminal on the rear panel of 
    the DVR with the system controller (Figure 1). 
    2Display the  screen as explained in 
    Displaying the general settings screen, and then 
    turn the S-dial clockwise. (P62)
    The DATA SPEED 19200 indicator starts blinking.
    3Turn the J-dial to select the desired DATA SPEED 
    (example: 9600), and then turn the S-dial twice 
    clockwise. 
    Selections: 2400/4800/9600/19200
    The OFF indicator of STATUS INFO starts blinking.
    4Repeat the procedure for selecting the desired 
    settings for each item. 
     STATUS INFO
    OFF: The status information will not be sent. 
    ON: The status information will be sent. 
     ALARM INFO
    OFF: The alarm information will not be sent. 
    ON: The alarm information will be sent. 
     ADDRESS
    The address should be between 000~127.
    The address is fixed, and it should match the 
    address of the PTZ camera. Refer to the List of 
    camera address for more information. (P90)
    Refer to the system controllers instruction manual for 
    more information about the control method. 
    5Press the EXIT/OSD button.
    FRS-485 settings
    MENU
    (J)(S)                                  
             DATA SPEED   :   19200
             STATUS INFO  :  ON
             ALARM INFO   :  ON
             ADDRESS      :  001
     6.RS-485 SET
     3.GENERAL SET
    
    
    STATUS INFO : OFF
    EXIT/OSD
    POWER MODE AU TO MENU
    RS485B A
    61
    VIDEOCOM SWON1
    234ABTELEMETRY
    12V
    SW
    ON1
    234RS-485TERMINATEOFF ON
    RS-485TERMINATEOFF ON
    CARD CARDMENU
    RESETEJECTCARD CARDMENU
    RESETEJECT
    Figure 1 (Do not use telephone wires.)
    System controller 
    (sold separately)
    Straight cable Cross cableTo  o t h e r  
    A terminals
    The DVR supports straight and cross-type cables.
     Straight type:
    A straight cable connects connector A to A, and 
    B to B of the RS-485 connectors. 
    Cross type:
    A cross cable connects connector A with B, and 
    B with A on the RS-485 connectors.
    Pin numberConnector AConnector B
    1 Not used Not used
    2 Not used Not used
    3AB
    4BA
    5 Not used Not used
    6 Not used Not used
    Dome camera (sold separately)
    Terminator switch settings
    If multiple devices are connected, terminator settings are 
    necessary at both ends. If the terminator settings are not 
    correct, correct data will not be sent to the devices.
     Set the terminator switch on both ends (first device and last 
    device) to ON, and set it to OFF on all other devices.  
    						
    							English
    General settings
    71 How to set
    The protocol (address)  and the external alarm trigger 
    control settings are needed when operating the coaxial 
    superimposed dome camera.
    If the protocol settings are set to OFF the ALARM REC 
    TRIGGER SET cannot be set.
    1Connect the VIDEO IN terminal on the rear panel of 
    the DVR to a remotely controllable dome camera 
    using a coaxial cable. (Figure 1)
    2Display the  screen as 
    explained in Displaying the general settings 
    screen (P62).
    3Turn the J-dial to select PROTOCOL/ADDRESS 
    SET and then turn the S-dial clockwise.
    The  screen is 
    displayed.
    4Turn the J-dial to move the cursor to the channel 
    number (example: 06) of the VIDEO IN terminal 
    where the camera is connected to the rear panel of 
    the DVR, and then turn the S-dial clockwise.
    The OFF starts blinking.
    5Turn the J-dial to select the PROTOCOL setting 
    (example: SANYO COAX1), and then turn the S-dial 
    clockwise. 
    The address (ADD.) is preset, it cannot be modified.
    Refer to List of camera addresses for more 
    information. (P90)Selections:
    OFF: No camera control
    SANYO COAX1: 
    Camera control by coaxial superimposition of the 
    SANYO (SSP) protocol. 
    The address is automatically displayed.
    SANYO RS485: 
    Camera control by SANYO (SSP) protocol using 
    RS485. 
    The address is automatically displayed.
    BBV COAX: 
    Camera control by coaxial superimposition of the 
    BBV protocol. 
    PELCO COAX: 
    Camera control by coaxial superimposition of the 
    PELCO protocol. 
    SANYO COAX2: 
    Camera control by high-speed coaxial 
    superimposition.
    6Press the EXIT/OSD button.
    7Press the FUNC. button.
    The indicator on the FUNC. button and the control 
    indicators turn on. (P73)
    Press the FUNC. button again to exit the function 
    control.
    GCamera control settings
    MENU
    (J)(S)
     7.CAMERA CONTROL SET
     3.GENERAL SET
    
    
     
      
         1. PROTOCOL/ADDRESS SET        ->
         2. ALARM REC TRIGGER SET       ->
                 
     CH PROTOCOL     ADD.   CH PROTOCOL     ADD. 
     01 OFF          ---    09 OFF          ---
     02 OFF          ---    10 OFF          ---
     03 OFF          ---    11 OFF          ---
     04 OFF          ---    12 OFF          ---
     05 OFF          ---    13 OFF          ---
     06 OFF          ---    14 OFF          ---
     07 OFF          ---    15 OFF          ---
     08 OFF          ---    16 OFF          ---
    06 OFF          ---
     Third-party cameras controlled by RS485, RS422 
    etc. are not supported. Consult with the store where 
    you purchased your system regarding the types of 
    cameras that are supported. 
     In order to prevent control mistakes, set the 
    PROTOCOL setting to OFF for channels with 
    cameras that are not capable of coaxial 
    superimposition or not of the supported types.
    06 SANYO COAX1  006
    EXIT/OSD
    FUNC.
    POWER MODE AU TO MENU
    Dome camera (sold separately)
    Figure 1 
    						
    							English
    General settings
    How to set 72
    Depending on the settings of the selections under 
    ALARM RECORDING, the camera lens can be set to 
    move to a preset position or automatic panning when an 
    alarm is detected.
    Confirm the ALARM RECORDING setting. (P56) 
    1Display the  screen 
    using Displaying the general settings screen 
    (P62).
    2Turn the J-dial to select ALARM REC TRIGGER 
    SET and then turn the S-dial clockwise.
    The  screen is 
    displayed.
    3Turn the J-dial to select the camera (CH) that will do 
    the trigger operation when an alarm is detected and 
    then turn the S-dial clockwise.
    The OFF starts blinking.
    4Turn the J-dial to select the motion operation 
    (example: 05 SEQUENCE) and then turn the S-dial 
    clockwise.
    The SEQUENCE is displayed, the cursor moves to the 
    OFF of the next camera so other cameras can be set 
    if necessary.
    Selections:
    OFF: No trigger operation.
    PRESET (2~9/16): Moves to the preset number.
    PAN: Starts auto panning.
    TOUR: Starts tour operations.
    SEQUENCE: Starts automatic sequence operation.
    5Press the EXIT/OSD button.
    6Press the FUNC. button.
    The indicator on the FUNC. button and the control 
    indicators turn on. (P73)
    Press the FUNC. button again to exit the function 
    control.
    G-1Alarm recording trigger settings
                 
       ALARM RECORDING         : OFF
       PICTURE QUALITY         : ENHANCED
       AUDIO RECORDING         : OFF
       ALARM INTERLEAVE        : ONLY   
         REC RATE:  12.5FPS,      DURATION: 20SEC  
       PRE-ALARM RECORDING     : ***
         REC RATE: **** FPS,      DURATION: ****
         =>  (01731 ALARMS CAN BE RECORDED)
       ALARM TRIGGER           : ALARM
         MOTION SENSOR                ->
    MENU
    (J)(S)
     7.CAMERA CONTROL SET
     3.GENERAL SET
    
    
     
      
         1. PROTOCOL/ADDRESS SET        ->
         2. ALARM REC TRIGGER SET       ->
                 
     CH PROTOCOL     ADD.   CH PROTOCOL     ADD. 
     01 OFF          ---    09 OFF          ---
     02 OFF          ---    10 OFF          ---
     03 OFF          ---    11 OFF          ---
     04 OFF          ---    12 OFF          ---
     05 OFF          ---    13 OFF          ---
     06 OFF          ---    14 OFF          ---
     07 OFF          ---    15 OFF          ---
     08 OFF          ---    16 OFF          ---            
     CH ACTION             CH ACTION 
     01 ---------          09 ---------
     02 ---------          10 ---------
     03 ---------          11 ---------
     04 ---------          12 ---------
     05 ---------          13 ---------
     06 ---------          14 ---------
     07 ---------          15 ---------
     08 ---------          16 ---------
    Note:When several alarms are detected at the same time, it is 
    possible that the camera control is disabled, depending on the 
    camera control setting for the alarm recording.
    05 SEQUENCE
    EXIT/OSD
    FUNC. 
    						
    							English
    General settings
    73 How to set
    bCamera control is not possible in the following 
    cases, even if the function indicator (FUNC.) is 
    ON.
     While displaying menus, or the search menu
     During playback (during pause, or copy menu is 
    display)
     During quad-screen, multi-screen (9/16) and plus 
    screen display
     During zooming, automatic scrolling and monitor 2 
    display
    bIf another button is pressed while the following 
    indicators are blinking (controllable state), the 
    control function will be automatically cancelled. 
     PRESET, IRIS, FOCUS indicators
    APress the FUNC. button.
    While the FUNC. indicator is ON, the dome cameras can be operated by using the control buttons listed under 1 ~ H. 
    1Preset button (PRESET)
    When the PRESET button is pressed followed by the 
    camera selection button, the lens moves to the preset 
    position, and the preset call is cancelled.
    Pressing the PRESET button for approximately 3 seconds 
    will activate the registration status. Pressing on the camera 
    selection button allows you to register it.
    2Sequence button (SEQUENCE)
    The cameras will start automatic sequence operation. If 
    another button is pressed, the automatic sequence 
    operation will be cancelled.
    3Tour button (TOUR)
    Performs tour operation. 
    If another button is pressed, the tour operation will be 
    cancelled.
    4Automatic panning button (AUTO PAN)
    Performs automatic panning. If another button is pressed, 
    panning will stop. 
    5Menu button (MENU)
    Displays the cameras internal menu on the monitor. 
    6Confirmation button (ENTER)
    This button is used to confirm the contents of the menu 
    screen. 
    7Autofocus button (AF)
    Use this button to adjust the focus with one touch. 
    8Iris button (IRIS)
    Use this button to switch to iris adjustment mode; the IRIS 
    indicator will start blinking. 
    Press the ZOOM/I/FOo button to close the iris, and 
    press the ZOOM/I/FOp button to open the iris. 
    Press the IRIS button once again to exit the iris adjustment 
    mode. 
    9Focus button (FOCUS) 
    Use this button to switch to focus adjustment mode; the 
    FOCUS indicator will start blinking. 
    Press the ZOOM/I/FOo button to set the focus on nearby 
    objects, and press the ZOOM/I/FOp button to set the 
    focus on far-off objects. 
    Press the FOCUS button once again to exit the focus 
    adjustment mode. 
    FZoom/Iris/Focus button (ZOOM/I/FO)
    Press the o button to shrink the screen, and press the 
    p button to enlarge it.
    GPan dial (PAN)
    Performs panning.
    Turn the PAN dial clockwise to move the lens to the right, 
    and turn it counterclockwise to move the lens to the left. 
    Larger turning angle results in faster movement; and 
    smaller turning angle results in slower movement.
    HTilt dial (TILT)
    Performs tilting.
    Turn the TILT dial clockwise to tilt the lens down, and turn it 
    counterclockwise to tilt the lens up. 
    G-2Camera control from the DVR
    PRESETMENU ENTER AF
    IRIS
    FOCUS
    ZOOM/I/FOAU TO PA N
    SEQUENCE
    TOURPAN
    4
    2 13 9F H56 78 G
    A 
    						
    							English
    How to set 74
    Screen setting
    Menu configuration
                       
     CH          01  02  03  04  05  06  07  08
      MAIN MON.  OFF OFF OFF OFF OFF OFF OFF OFF
      MON.2      OFF OFF OFF OFF OFF OFF OFF OFF
      NETWORK    OFF OFF OFF OFF OFF OFF OFF OFF
     CH          09  10  11  12  13  14  15  16
      MAIN MON.  OFF OFF OFF OFF OFF OFF OFF OFF
      MON.2      OFF OFF OFF OFF OFF OFF OFF OFF
      NETWORK    OFF OFF OFF OFF OFF OFF OFF OFF
                 
      CH          01  02  03  04  05  06  07  08
       MAIN MON.  ON  ON  ON  ON  ON  ON  ON  ON
       MON.2      ON  ON  ON  ON  ON  ON  ON  ON
      CH          09  10  11  12  13  14  15  16
       MAIN MON.  ON  ON  ON  ON  ON  ON  ON  ON
       MON.2      ON  ON  ON  ON  ON  ON  ON  ON
                          
                 QUAD1            QUAD2
                 QUAD3            QUAD4
                  CHECK THE SCREEN ->
    01
    0205
    04 0306
    08 07
    0910 13
    12
    1114
    16 15
                         
                  CHECK THE SCREEN ->
    01
    02
    0503
    06 04
    08 09 07
                        
                  CHECK THE SCREEN ->
    01
    02
    0603
    07 05
    10 1104
    08
    12 09
    14 15 16 13
    0302
    0506
    01
    04
    070809
    12
    16
    03 04
    13 14 1507
    08
    09 10 11 12
    0102
    05060201
    0403
                     
                MAIN MON.  FULL  :  1SEC
                           QUAD  :  1SEC 
                MON.2      FULL  :  1SEC 
               INDIVIDUAL INTERVAL (SEC)
           01:  1  02:  1  03:  1  04:  1
           05:  1  06:  1  07:  1  08:  1
           09:  1  10:  1  11:  1  12:  1
           13:  1  14:  1  15:  1  16:  1
    06
    03
    04
    01-01-06   00:00:00  
    05
    0605
    0807
    0201
    0403
    01
    04
                      
                 CH01   COLOR LEVEL : 5
                     
           1.MULTI SCREEN      :  NORMAL
              QUAD POSITION SET       ->
              MULTI 9 POSITION SET    ->
              MULTI 16 POSITION SET   ->
           2.SEQUENCE          :  1SEC
              SEQUENCE SET            ->
              MAIN/MON.2 MONITOR SET  ->
           3.MASK              :  OFF
              MASK SET                ->
           4.COLOR LEVEL SET          ->
           TIME PERIOD : T-1 (06:00-11:30)
          TIME PERIOD : T-1 (06:00-11:30)
    bDisplaying the screen settings
    1Press the MENU button and use the 
    J-dial to select 4. SCREEN SET, and 
    then turn the S-dial clockwise.
    The  screen appears.
    2Turn the J-dial, select the desired 
    submenu, and turn the S-dial 
    clockwise.
    The selected screen (A~D) is 
    displayed. Refer to the appropriate 
    pages for the settings.
    (S)
    (J)
    MENU                  
          1.INITIAL SET                  ->
          2.RECORD SET                   ->
          3.GENERAL SET                  ->
          4.SCREEN SET                   ->
          5.POWER LOSS/USED TIME         ->
    (S)
    (J)
    AChanging the multi-screen sequence (P75)
    Screen-position modification for live video and playback.
    BSwitching screen at time intervals (P76)
     This setting is used to scroll all live videos based on preset time intervals.
     This setting specifies the monitor to use for live video display during the 
    time set in the time period settings (TIME PERIOD A/B).
    CMasking specific camera images (P78)
    This setting specifies when to use a gray pattern to mask certain camera 
    video on the screen.
    DAdjusting color tones of the live video (P79)
    This setting is used to adjust the color tone of the video on the monitor. 
    ☞The DSR-3709PA does not display 
    MULTI 16 POSITION SET.
    (DSR-3716PA) 
    						
    							English
    Screen setting
    75 How to set
    1Display the  screen as explained in 
    Displaying the screen settings, and then turn the 
    S-dial clockwise. (P74)
    The NORMAL field of 1. MULTI SCREEN starts 
    blinking.
    2Turn the J-dial, select CHANGE, and then turn the 
    S-dial clockwise. 
    Selections: 
    NORMAL: 
    No specified display positions for multi-screen 
    display
    CHANGE: 
    Specified positions for multi-screen (quad/9/16) 
    display
    The cursor moves to QUAD POSITION SET. 
    Turn the J-dial and select the quad, multi-9 or multi-16 
    screen as shown below, for changing the display 
    positions.
    3Example: Switching the live video of the camera 5 
    and camera 1 on the quad screen.
    1Turn the J-dial, select QUAD POSITION SET, 
    and then turn the S-dial clockwise. 
    The  screen 
    appears. 
    2Turn the J-dial, select 01 to QUAD1, and then 
    turn the S-dial clockwise. 
    The 01 indicator starts blinking.
    3Turn the J-dial, select 05, and turn the S-dial 
    clockwise.
    4Turn the J-dial, select CHECK THE SCREEN, 
    and then turn the S-dial clockwise. 
    The  screen with live 
    video appears. Check if camera 1 was replaced by 
    camera 5. 
    Press the QUAD button to check the screen of 
    QUAD2 and beyond.
    5Turn the S-dial counterclockwise. 
    The  screen 
    returns. 
    Repeat the operation for changing the order of multi-9 
    or multi-16 screen display. 
    4Press the EXIT/OSD button. 
    Press the QUAD or the MULTI buttons on the 
    normal live display to see the order of the display 
    changed.
    AChanging the multi-screen sequence
    (S)
     4.SCREEN SET
                     
           1.MULTI SCREEN      :  NORMAL
              QUAD POSITION SET       ->
              MULTI 9 POSITION SET    ->
              MULTI 16 POSITION SET   ->
           2.SEQUENCE          :  1SEC
              SEQUENCE SET            ->
              MAIN/MON.2 MONITOR SET  ->
           3.MASK              :  OFF
              MASK SET                ->
           4.COLOR LEVEL SET          ->
    MENU
                     
           1.MULTI SCREEN      :  CHANGE
              QUAD POSITION SET       ->
              MULTI 9 POSITION SET    ->
              MULTI 16 POSITION SET   ->
           2.SEQUENCE          :  1SEC
              SEQUENCE SET            ->
              MAIN/MON.2 MONITOR SET  ->
           3.MASK              :  OFF
              MASK SET                ->
           4.COLOR LEVEL SET          ->                       
                
                  CHECK THE SCREEN ->
    01
    02
    0503
    06 04
    08 09 07
                          
                
                  CHECK THE SCREEN ->
    01
    02
    0603
    07 05
    10 1104
    08
    12 09
    14 15 16 13
                          
                 QUAD1            QUAD2
                 QUAD3            QUAD4
                  CHECK THE SCREEN ->
    01
    0205
    04 0306
    08 07
    0910 13
    12 1114
    16 15
    02
    04 030102
    04 0305
    QUAD1QUAD1
    05 06
    08 07
    0910 13
    12
    1114
    16 15
                          
                 QUAD1             QUAD2
                
     QUAD3             QUAD4
                  CHECK THE SCREEN ->
    02
    0403
    05
    05
    02
    04 03
    QUAD
    
    EXIT/OSD 
    						
    							English
    Screen setting
    How to set 76
    1Display the  screen as explained in 
    Displaying the screen settings (P74). 
    The cursor moves to the 1. MULTI SCREEN position.
    2Turn the J-dial to select 2. SEQUENCE, and then 
    turn the S-dial clockwise. 
    Selections: 1/2/ ... 29/30SEC/INDIV.
    The 1SEC indicator starts blinking.
    After specifying the number of seconds, the cursor will 
    not move to the SEQUENCE SET position. This way 
    the automatic sequence will be set to the same interval.
    3Turn the J-dial to select the 2. SEQUENCE 
    (example: 5 seconds), and then turn the S-dial 
    clockwise.
    4Press the EXIT/OSD button.
    5Press the SEQUENCE button.
    The video on the main monitor and the monitor 2 will 
    switch every 5 seconds.Display the  screen.
    1Turn the J-dial to select 2. SEQUENCE, and then 
    turn the S-dial clockwise. 
    Selections: 1/2/ ... 29/30SEC/INDIV.
    The 1SEC indicator starts blinking.
    2Turn the J-dial to select INDIV., and then turn the 
    S-dial twice clockwise. 
    The  screen appears.
    3Turn the S-dial clockwise.
    The 1SEC of MAIN MON. FULL starts blinking.
    4Setting the interval time between the MAIN MON. 
    and the MON2.
    1Turn the J-dial to select 5SEC for MAIN MON. 
    FULL, and then turn the S-dial twice clockwise. 
    Selections: 1/2/ ... 29/30SEC/INDIV.
    2Turn the J-dial to select 10SEC for MAIN MON. 
    QUAD, and then turn the S-dial twice clockwise. 
    Selections: 1/2/ ... 29/30SEC
    3Turn the J-dial to select 15SEC for MON.2 
    FULL, and then turn the S-dial clockwise. 
    Selections: 1/2/ ... 29/30SEC/INDIV.
    5Press the EXIT/OSD button.
    6Press the SEQUENCE button.
    The monitor video will be switched the following way:
     Main monitor full-screen video every 5 seconds
     Main monitor quad-screen video every 10 seconds
     Monitor 2 full-screen video every 15 seconds
    B
    Automatic scrolling of live video of the 
    main monitor and the monitor 2 at 
    identical intervals (example: 5 seconds)
    (S)
    MENU
                     
           1.MULTI SCREEN      :  CHANGE
              QUAD POSITION SET       ->
              MULTI 9 POSITION SET    ->
              MULTI 16 POSITION SET   ->
           2.SEQUENCE          :  5SEC
              SEQUENCE SET            ->
              MAIN/MON.2 MONITOR SET  ->
           3.MASK              :  OFF
              MASK SET                ->
           4.COLOR LEVEL SET          ->
     4.SCREEN SET
    
    2.SEQUENCE          :  1SEC
    2.SEQUENCE          :  5SEC
    EXIT/OSD
    SEQUENCE
    B-1
    Automatic scrolling of live video of the 
    main monitor and the monitor 2 at 
    individual intervals (example: 5 seconds)
    2.SEQUENCE          :  1SEC
                    
              MAIN MON.   FULL   :   1SEC
                          QUAD   :   1SEC 
              MON.2       FULL   :   1SEC 
    (S)
    MAIN MON.   FULL   :   5SEC
                QUAD   :  10SEC
    MON.2       FULL   :  15SEC
    EXIT/OSD
    SEQUENCE 
    						
    							English
    Screen setting
    77 How to set
    1Display the  screen as explained in 
    Displaying the screen settings (P74). 
    2Turn the J-dial, select 2. SEQUENCE, and then 
    turn the S-dial clockwise. 
    3Turn the J-dial to select INDIV., and then turn the 
    S-dial twice clockwise. 
    4Turn the S-dial clockwise.
    5Turn the J-dial, select INDIV. for the MAIN MON. 
    FULL, and then turn the S-dial clockwise. 
    MAIN MON. QUAD cannot be set to INDIV..
    6Turn the J-dial to select MON.2 FULL, and then 
    turn the S-dial clockwise. 
    The 1SEC (example) indicator starts blinking.
    7Turn the J-dial to select 3SEC, and then turn the 
    S-dial twice clockwise. 
    1 SEC of channel 1 (01) under INDIVIDUAL 
    INTERVAL (SEC) starts blinking.
    8Turn the J-dial to set the interval for channel 1 (01) 
    of the main monitor (example: 5), and then turn the 
    S-dial clockwise. 
    Repeat the procedure for setting the interval for the 
    other channels.
    9Press the EXIT/OSD button.
    ÀPress the SEQUENCE button.
    1Set TIME PERIOD A and TIME PERIOD B using 
     (P37). 
    Select TIME PERIOD A or TIME PERIOD B for 
    SEQUENCE under SELECT TIME PERIOD.
    The example uses TIME PERIOD A.
    2Turn the J-dial on the  screen to 
    select MAIN/MON.2 MONITOR SET, and then turn 
    the S-dial twice clockwise. 
    The  screen appears, 
    and T-1 at TIME PERIOD starts blinking.
    3Turn the J-dial to select the desired TIME PERIOD 
    (example: T-2), and then turn the S-dial twice 
    clockwise. 
    The ON indicator at CH 01 on the MAIN MON. line 
    starts blinking.
    4Turn the J-dial, select OFF, and turn the S-dial. 
    Repeat the procedure to turn OFF the display of all 
    desired cameras.
    5Press the EXIT/OSD button.
    6Press the SEQUENCE button.
    B-2
    Automatic sequence of live video of the 
    main monitor (full-screen) at individual 
    intervals, and of the monitor 2 at identical 
    intervals (example: 3 seconds)
                     
                MAIN MON.  FULL  : INDIV.
                           QUAD  :  1SEC 
                MON.2      FULL  :  5SEC 
               INDIVIDUAL INTERVAL (SEC)
           01:  5  02:  1  03:  1  04:  1
           05:  1  06:  1  07:  1  08:  1
           09:  1  10:  1  11:  1  12:  1
           13:  1  14:  1  15:  1  16:  1
    EXIT/OSD
    SEQUENCE
    B-3Turning off display of specified 
    cameras during timer-controlled 
    periods
                     
              QUAD POSITION SET       ->
              MULTI 9 POSITION SET    ->
              MULTI 16 POSITION SET   ->
           2.SEQUENCE          :  1SEC
              SEQUENCE SET            ->
           3.MASK              :  OFF
              MASK SET                ->
           4.COLOR LEVEL SET          ->                            
     TIME PERIOD       T-1    T-2    T-3    T-4
       TIME PERIOD A  06:00  11:30  13:30  18:00
       TIME PERIOD B  06:00  08:00  14:30  20:00
     
       SELECT TIME PERIOD
           SEQUENCE         TIME PERIOD A
           MASK             TIME PERIOD A
           MOTION SENSOR    TIME PERIOD A
             1.MULTI SCREEN      :  CHANGE
              MAIN/MON.2 MONITOR SET  ->
    TIME PERIOD : T-1 (06:00-11:30)
                 
      CH          01  02  03  04  05  06  07  08
       MAIN MON.  ON  ON  ON  ON  ON  ON  ON  ON
       MON.2      ON  ON  ON  ON  ON  ON  ON  ON
           TIME PERIOD : T-2 (06:00-11:30)
                 
      CH          01  02  03  04  05  06  07  08
       MAIN MON.  OFF ON  OFF ON  OFF ON  ON  ON
       MON.2      ON  OFF ON  OFF ON  OFF ON  ON        TIME PERIOD : T-2 (06:00-11:30)
    EXIT/OSD
    SEQUENCE 
    						
    							English
    Screen setting
    How to set 78
    1Set TIME PERIOD A and TIME PERIOD B using 
     (P37). 
    Select TIME PERIOD A or TIME PERIOD B for 
    MASK under SELECT TIME PERIOD. 
    The example uses TIME PERIOD A.
    2Display the  screen as explained in 
    Displaying the screen settings (P74). 
    The cursor moves to 1. MULTI SCREEN.
    3Turn the J-dial, select 3. MASK, and then turn the 
    S-dial clockwise. 
    The OFF starts blinking.
    4Turn the J-dial, select ON, and turn the S-dial 
    clockwise. 
    The cursor moves to MASK SET.
    5Turn the S-dial clockwise.
    The  screen appears and the cursor 
    moves to T-1.
    6Turn the S-dial, and use the J-dial to select the 
    desired TIME PERIOD (example: T-2), and then turn 
    the S-dial clockwise. 
    The cursor moves to 01 (CH) of the MAIN MON. line.
    7Turn the J-dial to select the camera number 
    (example: 03) of the MAIN MON., and then turn the 
    S-dial clockwise. 
    8Turn the J-dial, select ON, and turn the S-dial 
    clockwise. 
    Repeat the procedure to turn the masking ON for all 
    desired cameras on MON.2 and on NETWORK. 
    9Press the EXIT/OSD button.
    CMasking specific camera images
                               
     TIME PERIOD       T-1    T-2    T-3    T-4
       TIME PERIOD A  06:00  11:30  13:30  18:00
       TIME PERIOD B  06:00  08:00  14:30  20:00
     
       SELECT TIME PERIOD
           SEQUENCE         TIME PERIOD A
           MASK             TIME PERIOD A
           MOTION SENSOR    TIME PERIOD A
      
                     
           1.MULTI SCREEN      :  CHANGE
              QUAD POSITION SET       ->
              MULTI 9 POSITION SET    ->
              MULTI 16 POSITION SET   ->
           2.SEQUENCE          :  1SEC
              SEQUENCE SET            ->
              MAIN/MON.2 MONITOR SET  ->
              MASK SET                ->
           4.COLOR LEVEL SET          ->
    (S)
    MENU
     4.SCREEN SET
    
           3.MASK              :  ON
        MASK SET           ->
                       
     CH          01  02  03  04  05  06  07  08
      MAIN MON.  OFF OFF OFF OFF OFF OFF OFF OFF
      MON.2      OFF OFF OFF OFF OFF OFF OFF OFF
      NETWORK    OFF OFF OFF OFF OFF OFF OFF OFF
     CH          09  10  11  12  13  14  15  16
      MAIN MON.  OFF OFF OFF OFF OFF OFF OFF OFF
      MON.2      OFF OFF OFF OFF OFF OFF OFF OFF
      NETWORK    OFF OFF OFF OFF OFF OFF OFF OFF
          TIME PERIOD : T-1 (06:00-11:30)
                       
     CH          01  02  03  04  05  06  07  08
      MAIN MON.  OFF OFF ON  OFF ON  OFF ON  OFF
      MON.2      OFF ON  OFF ON  OFF ON  OFF ON
      NETWORK    ON  OFF ON  OFF ON  OFF ON  OFF
     CH          09  10  11  12  13  14  15  16
      MAIN MON.  OFF OFF OFF OFF OFF OFF OFF OFF
      MON.2      OFF OFF OFF OFF OFF OFF OFF OFF
      NETWORK    OFF OFF OFF OFF OFF OFF OFF OFF
          TIME PERIOD : T-2 (06:00-11:30)
    EXIT/OSD 
    						
    							English
    Screen setting
    79 How to set
    1Display the  screen as explained in 
    Displaying the screen settings (P74). 
    The cursor moves to the 1. MULTI SCREEN position.
    2Turn the J-dial, select 4. COLOR LEVEL SET, and 
    then turn the S-dial clockwise. 
    The  screen of CH01 appears, 
    and the cursor moves to COLOR LEVEL. 
    3Press the camera selection button (example: 7) of 
    the channel where you want to adjust the color 
    level, and then turn the S-dial clockwise. 
    The channel switches to CH07, and the 5 field at 
    COLOR LEVEL starts blinking.
    4Turn the J-dial, select the desired COLOR LEVEL, 
    and then turn the S-dial clockwise. 
    Selections: 1/2.../8/9/10 (darker)
    The color tone of the camera video changes. 
    5Press the EXIT/OSD button.
    DAdjusting color tones of the live video
    (S)
    MENU
                     
           1.MULTI SCREEN      :  NORMAL
              QUAD POSITION SET       ->
              MULTI 9 POSITION SET    ->
              MULTI 16 POSITION SET   ->
              SEQUENCE SET            ->
              MAIN/MON.2 MONITOR SET  ->
           3.MASK              :  OFF
              MASK SET                ->
           4.COLOR LEVEL SET          ->
     4.SCREEN SET
    
           2.SEQUENCE          :  1SEC
                      
                 CH01   COLOR LEVEL : 5
                      
                 CH07   COLOR LEVEL : 5
    (S)
    EXIT/OSD 
    						
    All Sanyo manuals Comments (0)