Home > Sanyo > Video Recorder > Sanyo Dsr 3716 P Manual

Sanyo Dsr 3716 P Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Sanyo Dsr 3716 P Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 550 Sanyo manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							English
    Recording settings
    How to set 40
    The following two easy settings are available.
    ☞Easy recording settings 1 (P41)☞Easy recording settings 2 (P42)
    (Menu item - Description)
    1RECORDING DURATION
    1 to 99 can be selected. The default setting is 1.
    2TIMER RECORDING (DLY)
    The timer-controlled recording can be switched ON or 
    OFF.
    When OFF is set, the cursor does not move to the 
    START time.
    3PICTURE QUALITY
    Selections:
    BASIC (BA): Rough image quality, approx. 15kB
    NORMAL (NO): Standard image quality, approx. 22kB
    ENHANCED (EN): Enhanced image quality, approx. 
    30kB
    FINE (FI): Fine image quality, approx. 42kB
    SUPER FINE (SF): Super fine image quality, approx. 
    50kB
    4AUDIO RECORDING
    Audio recording can be switched ON or OFF. Audio 
    recording can only be set if the recording rate is between 
    1~50 FPS. When the audio recording is ON, the letter A 
    will be displayed in front of the recording rate. Since both 
    audio and video will be stored in the normal recording 
    area, the recording capacity of this area will decrease.
    If the recording rate is out of the specified range, audio will 
    not be recorded.
    5NUMBER OF CAMERAS
    Displays the number of cameras connected to the DVR.
    6REC RATE
    Displays the maximum recording rate per camera based 
    on the other settings of this menu and the number of 
    cameras. If a valid number cannot be calculated, 
    ERROR! will be displayed.
    Modify the settings to resolve the problem.
    1REC RATE
    Selections:
    50, 25, 16.67, 12.5, 8.333 ,6.25, 5, 4.167, 3.571, 3.125, 
    2.778, 2.5, 2.273, 1.923, 1.667, 1.471, 1.316, 1.190, 
    1.087, 1, 0.5, 0.333, 0.25, 0.2, 0.1, 0.05, 0.033
    Audio recording can only be set when this setting is within 
    the range of 50~1 FPS.
    2RECORDING DURATION
    Displays the maximum recording duration per camera 
    based on the other settings of this menu and the number 
    of cameras. If a valid number cannot be calculated, 
    ERROR! will be displayed.
    Modify the settings to resolve the problem.
    AEasy recording menu description
                         
          RECORDING DURATION    :  -- DAYS
          TIMER RECORDING(DLY)  :  OFF
            START --:--       STOP  --:--
          PICTURE QUALITY       :  ENHANCED
          AUDIO RECORDING       :  OFF
          NUMBER OF CAMERAS     :  2
          REC RATE              :  ------FPS/CAM
    1
    3
    5
    62
    41
    2
                                   
          REC RATE             : ----- FPS/CAM
          TIMER RECORDING(DLY) : OFF
            START --:--      STOP  --:--
          PICTURE QUALITY      : ENHANCED
          AUDIO RECORDING      : OFF
          NUMBER OF CAMERAS    : 2
          RECORDING DURATION   : ---- DAYS
    The easy recording settings will be erased when the 
    following occur:  
     When the number of cameras stored until now on 
    the DVR increases or decreases.
     Using the , the pre-alarm 
    recording is switched to ON.
     Menu settings are loaded from a CompactFlash 
    card.
     A different easy recording setting is performed.
     The normal recording settings or timer settings are 
    modified.
     The recording areas of the hard disk are modified.
     When mirroring settings were changed under the 
    hard disk settings.
     When the hard disk was changed.
     When a hard disk was added. 
    						
    							English
    Recording settings
    41 How to set
    Setting the recording based on duration
    1Display the  screen as 
    explained in Displaying the recording settings 
    screen (P39).
    The  screen appears.
    2Turn the S-dial clockwise twice.
    The  screen is 
    displayed, and the 1 at RECORDING DURATION is 
    blinking.
    3Turn the J-dial to select the RECORDING 
    DURATION (example: 10), and then turn the S-dial 
    clockwise.
    The cursor moves to the TIMER RECORDING (DLY) 
    field.
    4Set the timer.
    Proceed to 5 if timer setting is not necessary.
    1Turn the S-dial clockwise.
    The OFF starts blinking.
    2Turn the J-dial to set TIMER RECORDING(DLY) to 
    ON, and then turn the S-dial clockwise.
    The cursor moves to the hour setting.
    3Turn the S-dial clockwise.
    The cursor moves to START.
    4Turn the J-dial, select the hour (example: 09), 
    and then turn the S-dial clockwise.
    The 00 indicator starts blinking.
    5Turn the J-dial, select the minutes (example: 30), 
    and then turn the S-dial clockwise.
    Repeat the same procedure to enter the STOP time. 
    The cursor moves to the PICTURE QUALITY 
    ENHANCED field.
    5Turn the S-dial clockwise. Turn the J-dial, select the 
    desired recording quality, and turn the S-dial 
    clockwise.
    The cursor moves to the OFF of the AUDIO 
    RECORDING field.
    6Turn the S-dial clockwise. Turn the J-dial to switch 
    AUDIO RECORDING ON, and then turn the S-dial 
    clockwise.
    The cursor returns to RECORDING DURATION.
    7Turn the S-dial counterclockwise.
    The  screen is displayed, and NO is 
    blinking.
     Turn the J-dial, select YES, and turn the S-dial 
    clockwise.
    Operation returns to the NORMAL REC EASY SET 
    screen.
    8Press the EXIT/OSD button when the settings are 
    complete.
    The normal screen is displayed again.
    A-1Easy recording settings 1
    MENU
    (J)(S)                   
          RECORDING DURATION BASE          ->
          REC RATE BASE                    ->
     1.NORMAL REC EASY SET
     2.RECORD SET
    
    
                         
          RECORDING DURATION    :  1 DAYS
          TIMER RECORDING(DLY)  :  OFF
            START --:--       STOP  --:--
          PICTURE QUALITY       :  ENHANCED
          AUDIO RECORDING       :  OFF
          NUMBER OF CAMERAS     :  16
          REC RATE              :  ------FPS/CAM
    (S)
    RECORDING DURATION : 10 DAYS
    TIMER RECORDING(DLY): OFF(J)(S)
    START   --:--    STOP  --:--
    START   09:30    STOP  18:30
                         
              
         REC RATE SETTING IN THE MENU WILL BE
                AUTOMATICALLY ADJUSTED.
              
                    ARE YOU SURE ? 
                          NO
    EXIT/OSD 
    						
    							English
    Recording settings
    How to set 42
    Set the recording based on recording rate
    1Display the  screen as 
    explained in Displaying the recording settings 
    screen (P39).
    The  screen appears.
    2Turn the J-dial to select REC RATE BASE, and 
    then turn the S-dial twice clockwise.
    The  screen is displayed, and the 
    number at REC RATE is blinking.
    3Turn the J-dial to select the REC RATE (example: 
    3.125), and then turn the S-dial clockwise.
    The cursor moves to the TIMER RECORDING (DLY) 
    field.
    4Set the timer.
    Proceed to 5 if timer setting is not necessary.
    1Turn the S-dial clockwise.
    The OFF starts blinking.
    2Turn the J-dial to set TIMER RECORDING(DLY) to 
    ON, and then turn the S-dial clockwise.
    The cursor moves to the hour setting.
    3Turn the S-dial clockwise.
    The cursor moves to START.
    4Turn the J-dial, select the hour (example: 09), 
    and then turn the S-dial clockwise.
    The 00 indicator starts blinking.
    5Turn the J-dial, select the minutes (example: 30), 
    and then turn the S-dial clockwise.
    Repeat the same procedure to enter the STOP time. 
    The cursor moves to the PICTURE QUALITY 
    ENHANCED field.
    5Turn the S-dial clockwise. Turn the J-dial to select 
    the desired recording quality, and then turn the 
    S-dial clockwise.
    The cursor moves to the AUDIO RECORDING OFF 
    field.
    6Turn the S-dial clockwise. Turn the J-dial to select 
    AUDIO RECORDING ON, and then turn S-dial 
    clockwise.
    The cursor returns to REC RATE.
    7Turn the S-dial counterclockwise.
    The  screen is displayed, and NO is 
    blinking.
     Turn the J-dial, select YES, and turn the S-dial 
    clockwise.
    Operation returns to the NORMAL REC EASY SET 
    screen.
    8Press the EXIT/OSD button when the settings are 
    complete.
    The normal screen is displayed again.
    A-2Easy recording settings 2
    MENU
    (J)(S)                   
          RECORDING DURATION BASE          ->
          REC RATE BASE                    ->
     1.NORMAL REC EASY SET
     2.RECORD SET
    
    
                                   
          REC RATE             : ----- FPS/CAM
          TIMER RECORDING(DLY) : OFF
            START --:--      STOP  --:--
          PICTURE QUALITY      : ENHANCED
          AUDIO RECORDING      : OFF
          NUMBER OF CAMERAS    : 16
          RECORDING DURATION   : ---- DAYS
    (J)(S)
    REC RATE           3.125FPS/CAM
    TIMER RECORDING(DLY): OFF(J)(S)
    START --:--  STOP --:--
    START 09:30  STOP 18:30
                         
              
         REC RATE SETTING IN THE MENU WILL BE
                AUTOMATICALLY ADJUSTED.
              
                    ARE YOU SURE ? 
                          NO
    EXIT/OSD 
    						
    							English
    Recording settings
    43 How to set
    This screen is used to verify the total capacity of the hard disk, and the recording capacity of the individual recording 
    areas. The recording areas can be modified as needed. Modifying the recording areas will result in initializing the hard 
    disk, and all recordings to be erased. Save the recordings to some other media before modifying the recording areas.
    1Displays the total capacity of the internal hard disk of 
    the DVR.
    If the hard disk is replaced, the total capacity will change.
    2Sets the recording capacity of the normal recording 
    area. The default setting is 80%; it can be manually 
    modified up to 99%.
    If the normal recording area is set to 0%, video is only 
    recorded in the alarm recording area.
    3Resets all the recording areas.
    4Sets the recording capacity of the alarm recording 
    area. The default setting is 19%; it can be manually 
    modified up to 99%.
     A maximum of 16,000 alarm events can be recorded on 
    one hard disk. Hard disk expansion allows for a 
    maximum of 32,000 events. Note that the recording 
    conditions will depend on the recording settings.
    5Sets the capacity of the archive area.
    The default setting is 1%; the upper limit is 99%. This 
    area cannot be set manually.
    bVerifying the capacity of the recording areas
    1Display the  screen as 
    explained in Displaying the recording settings 
    screen (P39).2Press the EXIT/OSD button to end the setting 
    procedure.
    BRecording area menu description
                 
         TOTAL CAPACITY               :   82GB
         NORMAL RECORDING AREA        :   80 %
            AREA FULL RESET   ->
         ALARM RECORDING AREA         :   19 %
            AREA FULL RESET   ->
         ARCHIVE AREA                 :    1 %
            AREA FULL RESET   ->
    CAUTION : WHEN THE AREA SETTING IS CHANGED,
              THE WHOLE AREA WILL BE INITIALIZED !
    80%80%80% 19%19%19%1%
    1%1%1
    2
    3
    4
    5
    Alarm recording 
    areaArchive area
    Normal recording area
    Hard disk recording areas
    MENU
    (J)(S)             
         TOTAL CAPACITY               :   82GB
         NORMAL RECORDING AREA        :   80 %
            AREA FULL RESET   ->
         ALARM RECORDING AREA         :   19 %
            AREA FULL RESET   ->
         ARCHIVE AREA                 :    1 %
            AREA FULL RESET   ->
     2.RECORDING AREA SET
     2.RECORD SET
    
    
    EXIT/OSD 
    						
    							English
    Recording settings
    How to set 44
    This operation will initialize the hard disk.
    1Display the  screen as 
    explained in Displaying the recording settings 
    screen (P39).
    2Turn the S-dial clockwise.
    The NORMAL RECORDING AREA : 80 starts 
    blinking.
    3Turn the J-dial to set the NORMAL RECORDING 
    AREA to 50% (example) and turn the S-dial twice 
    clockwise. 
    The cursor moves to ALARM RECORDING AREA 
    and the value starts blinking.
    4Turn the J-dial to set the ALARM RECORDING 
    AREA (49% in the example), and turn the S-dial 
    clockwise.
    The cursor moves to AREA FULL RESET of the 
    archive area settings.
    5Turn the S-dial clockwise.
    The  screen is displayed, and NO is 
    blinking. 
    6Turn the J-dial, select YES, and turn the S-dial 
    clockwise. 
    The HDD INITIALIZING! message appears, and the 
    initialization starts. 
    When the initialization is complete, the  
    screen returns.
    7Press the EXIT/OSD button.
    B-1Changing the normal recording area and the alarm recording area
    Note: The default setting in  
    for the normal and alarm recording areas is 
    OVERWRITE: ON. Therefore, after setting the normal 
    and alarm recording areas, the cursor will not move to 
    AREA FULL RESET. In order to use AREA FULL 
    RESET for the normal and alarm areas, set the 
    OVERWRITE setting to OFF under . (P47)
    MENU
    (J)(S)             
         TOTAL CAPACITY               :   82GB
         NORMAL RECORDING AREA        :   80 %
            AREA FULL RESET   ->
         ALARM RECORDING AREA         :   19 %
            AREA FULL RESET   ->
         ARCHIVE AREA                 :    1 %
            AREA FULL RESET   ->
     2.RECORDING AREA SET
     2.RECORD SET
    
    
    ALARM RECORDING AREA      : 19%
               
           NORMAL RECORDING AREA
              OVERWRITE              : OFF
           ALARM RECORDING AREA
              OVERWRITE              : ON
                       
              
         THIS CHANGE WILL INITIALIZE THE DISK.
             ALL RECORDING WILL BE ERASED.    
                    ARE YOU SURE ?
                    
                          NO
                   HDD INITIALIZING !
                       
              
         THIS CHANGE WILL INITIALIZE THE DISK.
             ALL RECORDING WILL BE ERASED.          
                    ARE YOU SURE ?
                    
                          NO
               CHANGE:JOG    SET:SHUTTLE
    EXIT/OSD 
    						
    							English
    Recording settings
    45 How to set
    The archive area cannot be automatically overwritten.
    1Display the  screen as 
    explained in Displaying the recording settings 
    screen (P39).
    2Turn the J-dial to select AREA FULL RESET, and 
    then turn the S-dial clockwise.
    The  screen is displayed.
    3Turn the J-dial, select YES, and turn the S-dial 
    clockwise.
    4Press the EXIT/OSD button to end the setting 
    procedure.
    B-2Archive area full reset
    Performing AREA FULL RESET will erase all images 
    from the archive area.
    MENU
    (J)(S)             
         TOTAL CAPACITY               :   82GB
         NORMAL RECORDING AREA        :   80 %
            AREA FULL RESET   ->
         ALARM RECORDING AREA         :   19 %
            AREA FULL RESET   ->
         ARCHIVE AREA                 :    1 %
            AREA FULL RESET   ->
    CAUTION : WHEN THE AREA SETTING IS CHANGED,
              THE WHOLE AREA WILL BE INITIALIZED !
     2.RECORDING AREA SET
     2.RECORD SET
    
    
                         
              
                   AREA FULL RESET
                    ARCHIVE AREA
              
                    ARE YOU SURE ?
                    
                         YES
               CHANGE:JOG    SET:SHUTTLE
    EXIT/OSD 
    						
    							English
    Recording settings
    How to set 46
    This menu is used to set whether to continue recording and automatically overwrite data, or stop recording without 
    overwriting the data when the normal recording area and the alarm recording area of the hard disk become full.
    1Selects the OVERWRITE setting for the normal 
    recording area.
    ON: When the normal recording area becomes full, the 
    new recordings will automatically overwrite existing 
    video, starting with the oldest recordings.
    OFF: When the normal recording area becomes full, 
    automatically stop recording.
    2Selects the OVERWRITE setting for the alarm 
    recording area.
    ON: When the alarm recording area becomes full, the 
    new recordings will automatically overwrite existing 
    video, starting with the oldest recordings.
    OFF: When the alarm recording area becomes full, 
    automatically stop recording.
    3REMAINING DISK WARNING
    Sets the FULL indicator to blink when the remaining hard 
    disk capacity drops below the specified volume.
    When OVERWRITE is turned OFF for the recording 
    areas, the REMAINING DISK WARNING changes from 
    ** to 1%.
    Selections: 1%, 2%, ... 9%, 10%
    4SERIES RECORDING (P47)
    If multiple hard disk recorders are connected, once the first 
    hard disk becomes full the second disk can take over the 
    recording. In the same way from the third disk on the 
    recording is taken over in sequential order.
    5AUTO DELETE (recording storage period)
    Sets the storage period for video recorded in the normal 
    and alarm recording areas. When the storage period has 
    expired, the data will be automatically deleted.
    Before using this setting, save the necessary videos to the 
    archive area or to a CompactFlash card.
    Selections: OFF, 1, 2, 3 ... 98, 99 days
    bRemaining hard disk capacity warning
    (Monitor: Operation display)
    When OVERWRITE is OFF, the operation display will 
    switch to show the remaining hard disk capacity.
    (DVR)
    For example, if 5% is set, then when 5% of the hard disk 
    capacity remains, the warning indicator (FULL) will start 
    blinking. If there is no more capacity left, the indicator will 
    change from blinking to continuously lit, and recording will 
    stop.
    CRecording conditions menu description
               
           NORMAL RECORDING AREA
              OVERWRITE              : ON
           ALARM RECORDING AREA
              OVERWRITE              : ON
           REMAINING DISK WARNING    : **
           SERIES RECORDING          : OFF
           AUTO DELETE               : OFF
    1
    2
    3
    4
    5
    26-10-06 02:20:20 REC REPEAT 5%
    26-10-06 02:20:20  REC 5%     EN A ALARM  0000
    ALARM FULL indicator
    FULL indicator 
    						
    							English
    Recording settings
    47 How to set
    1Display the  
    screen as explained in Displaying the recording 
    settings screen (P39).
    2Turn the J-dial to select OVERWRITE for the 
    normal or the alarm recording area, and then turn 
    the S-dial clockwise.
    3Turn the J-dial, select OFF, and turn the S-dial 
    clockwise.
    The REMAINING DISK WARNING changes from 
    ** to 1%, and disk overwrite is prohibited.
    If the available capacity in the normal or alarm 
    recording area drops below 1%, the corresponding 
    FULL indicator on the front panel of the DVR will start 
    blinking.
    4Changing the REMAINING DISK WARNING level 
    1 Turn the J-dial to select REMAINING DISK 
    WARNING, and then turn the S-dial clockwise.
    2 Turn the J-dial to select remaining level 
    (example: 5%), and then turn the S-dial 
    clockwise.
    The cursor moves to SERIES RECORDING.
    Selections: 1%, 2%, ... 9%, 10%
    5Press the EXIT/OSD button to end the setting 
    procedure.If multiple DVR units are connected, recording can be 
    automatically continued on the next DVR when the 
    recording area of the first one becomes full.
    1Connect the SERIES OUT terminal of the CONTROL 
    terminal block on the rear panel of the first DVR to 
    the SERIES IN terminal of the next DVR.
    C-1Overwrite setting for the recording 
    areas
    MENU
    (J)(S)              
         NORMAL RECORDING AREA
            OVERWRITE                   :  ON
         ALARM RECORDING AREA
            OVERWRITE                   :  ON
         RECORDING DISK WARNING         :  **
         SERIES RECORDING               :  ON
         AUTO DELETE                    :  OFF
     3.RECORDING CONDITIONS SET
     2.RECORD SET
    
    
    (J)(S)
         NORMAL RECORDING AREA
            OVERWRITE                   :  OFF
         ALARM RECORDING AREA
            OVERWRITE                   :  OFF
         REMAINING DISK WARNING         :  1%
         SERIES RECORDING               :  ON
         AUTO DELETE                    :  OFF                        
    EXIT/OSD
    C-2Setting series recording 
     Use cables no longer than 3m between the DVR units 
    for serial connection.
     Connect the MIC terminal and the AUDIO terminal as 
    shown below.
    SERIES IN
    SERIES OUT
    (First DVR unit)
    (Second DVR unit)
    (Third DVR unit)
    (Fourth DVR 
    and more)
    Microphone (sold separately)
    Amplifier (sold separately) 
    						
    							English
    Recording settings
    How to set 48
    2Display the  
    screen as explained in Displaying the recording 
    settings screen (P39).
    3Turn the S-dial to select OVERWRITE under 
    NORMAL RECORDING AREA. Turn the J-dial to 
    select OFF, and then turn the S-dial clockwise.
    Repeat the same procedure to set the OVERWRITE for 
    the ALARM RECORDING AREA to OFF.
    4Turn the J-dial to select SERIES RECORDING, 
    and then turn the S-dial clockwise.
    The cursor moves to OFF.
    5Turn the J-dial, select ON, and turn the S-dial 
    clockwise.
    6Press the EXIT/OSD button to return to the menu.
    7The series recording sets the following series 
    recording. Press the EXIT/OSD button.
     Normal recording (P49)
     Timer-controlled recording (P51)
     Sets normal recording and combined alarm 
    recording (P55, 56)
     Sets timer-controlled recording and combined alarm 
    recording (P55, 56)
    8Copy the setting contents of the menu to media 
    such as CompactFlash card as explained in the 
    COPY MENU SETTINGS section (P82).
    9Copy the setting contents of the copied menu to 
    DVR performing series recording (P82, 83).
    The DVR connected for series recording will have the 
    same menu settings.
    1Start recording on the first DVR.
     Press the REC/STOP button if using normal 
    recording or normal recording combined with alarm 
    recording.
     Press the TIMER button if using timer-controlled 
    recording or timer-controlled recording combined 
    with alarm recording.
    2If the normal or alarm recording area of the first 
    DVR is insufficient, the recording will stop and it 
    will automatically start on the hard disk of the next 
    connected DVR.
    3Stop the recording.
     Press the REC/STOP button for approximately 3 
    seconds if using normal recording or normal 
    recording combined with alarm recording.
     Press the TIMER button if using timer-controlled 
    recording or timer-controlled recording combined 
    with alarm recording.
    The archive area is not subject to storage expiration; 
    archived videos will not be erased. When the storage 
    period expires, video stored in the normal and alarm 
    recording areas will be automatically erased.
    1Turn the J-dial to select AUTO DELETE, and then 
    turn the S-dial clockwise.
    The cursor moves to OFF.
    2Turn the J-dial to select the storage period 
    (example: 10), and then turn the S-dial clockwise.
    3Press the EXIT/OSD button to end the setting 
    procedure.
    C-2Setting series recording (continued)
     Alarm recording cannot be used alone. Alarm 
    recording must be used in combination with normal 
    or timer-controlled recording.
     Normal recording and timer-controlled recording 
    cannot be used simultaneously. If both are set at the 
    same time, the timer-controlled recording will be 
    disabled.
    MENU
    (J)(S)
         NORMAL RECORDING AREA
            OVERWRITE                   :  OFF
         ALARM RECORDING AREA
            OVERWRITE                   :  OFF
         REMAINING DISK WARNING         :  1%
         SERIES RECORDING               :  OFF
         AUTO DELETE                    :  OFF
     3.RECORDING CONDITIONS SET
     2.RECORD SET
    
    
                
     SERIES RECORDING           : ON
    C-3Series recording
    When series recording is used, the normal and the 
    alarm recording areas will be automatically 
    overwritten. Save important videos before recording.
    C-4Setting the storage period (AUTO 
    DELETE) for videos recorded in the 
    recording areas 
    (J)(S)
               
           NORMAL RECORDING AREA
              OVERWRITE              : ON
           ALARM RECORDING AREA
              OVERWRITE              : ON
           REMAINING DISK WARNING    : **
           SERIES RECORDING          : OFF
           AUTO DELETE               : 10 DAYS
          
    EXIT/OSD 
    						
    							English
    Recording settings
    49 How to set
    This menu is used to set the picture quality, audio 
    recording and recording rate for the normal recording 
    area. A program number can be selected at the 
    programmed recording settings to use the recording rate 
    set for that program. (P50)
    1PICTURE QUALITY
    Selects the picture quality used to record video in the normal 
    recording area. The recording duration will change according to 
    the selected picture quality.
    Selections:
    BASIC: Rough image quality (BA)/15kB
    NORMAL: Normal image quality (NO)/22kB
    ENHANCED: Enhanced image quality (EN)/30kB
    FINE: Fine image quality (FI)/42kB
    SUPER FINE: Super fine image quality (SF)/50kB
    2AUDIO RECORDING
     When the AUDIO RECORDING is set to ON, the letter A 
    will be displayed in front of the available recording rates (REC 
    RATE). Audio recording is possible when the total recording 
    rate of the cameras is within the range of A50~A1FPS.
     Audio will only be played when the playback speed is the same 
    as the rate of recording. Video and audio may slightly be out of 
    synch.
    3REC RATE
    The recording rate is limited by the pre-alarm and mirroring 
    settings. (P88)
    ☞Refer to the recording rate and duration table. (P86)
    4REC PROGRAM GROUP (P50)
    This menu is used to specify the cameras to be used in each 
    group (P-1~P-4) for programmed recording. After selecting the 
    group, set the program for the group.
    Selections: OFF, P-1, P-2, P-3, P-4
    1Display the  screen as 
    explained in Displaying the recording settings 
    screen, and then turn the S-dial clockwise. (P39)
    The PICTURE QUALITY ENHANCED starts blinking.
    2Turn the J-dial to select the desired PICTURE 
    QUALITY (example: FINE), and then turn the S-dial 
    twice clockwise.
    The AUDIO RECORDING OFF field starts blinking.
    3Turn the J-dial to select the desired AUDIO 
    RECORDING (example: ON), and then turn the 
    S-dial twice clockwise.
    The letter A is displayed indicating AUDIO 
    RECORDING, and then the REC RATE starts blinking.
    4Turn the J-dial to select the desired REC RATE 
    (example: 6.25), and then turn the S-dial twice 
    clockwise.
    The REC PROGRAM GROUP OFF starts blinking.
    5Turn the J-dial to select the desired REC PROGRAM 
    GROUP (example: P-1), and then turn the S-dial 
    clockwise.
    REC RATE will be displayed as ***.
    6Press the EXIT/OSD button to end the setting 
    procedure.
    The operation display area displays the settings as 
    shown below.
    DNormal recording area menu 
    description
                       
        PICTURE QUALITY      : ENHANCED
        AUDIO RECORDING      : OFF
        REC RATE   :  12.5FPS (  42H)
        REC PROGRAM GROUP    : OFF
    1
    2
    3
    4
    D-1Normal recording area settings
    MENU
    (J)(S)                   
        PICTURE QUALITY      : ENHANCED
        AUDIO RECORDING      : OFF
        REC RATE   :  12.5FPS (  42H)
        REC PROGRAM GROUP    : OFF
     4.NORMAL REC MODE SET
     2.RECORD SET
    
    
    EXIT/OSD 
    						
    All Sanyo manuals Comments (0)