Page 21
21 Before Installing the Product (Installation Guide)To prevent injury, this apparatus must be securely attached to the floor/wall in accordance with the installation instructions. •Ensure that an authorized installation company installs the wall mount. •Otherwise, it may fall and cause personal injury. •Make sure to install the specified wall mount. Switching between portrait and landscape ― Contact Samsung Customer Service Center for further details. • To use the product in portrait orientation,...
Page 22
22 A B C E Figure 1.3 Side view D D Figure 1.2 Side view Installation on an Indented Wall ― Contact Samsung Customer Service Center for further details. Plane view A Minimum 40 mm B Minimum 70 mm C Minimum 50 mm D Minimum 50 mm E Ambient temperature: Under 35 C ―When installing the product on an indented wall, allow at least the space specified above between the product and wall for ventilation and ensure that the ambient temperature is kept below 35 C. Dimensions 1 2 3 4 5 Unit: mm (inches) Model...
Page 23
23 Installing the Wall Mount 1 Preparing before installing Wall-Mount To install a wall-mount from another manufacturer, use the Holder-Ring(). Installing the Wall Mount The wall mount kit (sold separately) allows you to mount the product on the wall. For detailed information on installing the wall mount, see the instructions provided with the wall mount. We recommend you contact a technician for assistance when installing the wall mount bracket. Samsung Electronics is not responsible for any damage to...
Page 24
24 Wall Mount Kit Specifications (VESA) ―Install your wall mount on a solid wall perpendicular to the floor. Before attaching the wall mount to surfaces other than plaster board, please contact your nearest dealer for additional information. If you install the product on a slanted wall, it may fall and result in severe personal injury. • Samsung wall mount kits contain a detailed installation manual and all parts necessary for assembly are provided. •Do not use screws that are longer than the...
Page 25
25 Remote Control (RS232C) Cable Connection RS232C Cable InterfaceRS232C (9 pins) PinTxD (No.2), RxD (No.3), GND (No.5) Bit rate9600 bps Data bits8 bit ParityNone Stop bit1 bit Flow controlNone Maximum length15 m (only shielded type) •Pin assignment 12 3 4 5 6 7 8 9 Pin Signal 1Detect data carrier 2Received data 3Transmitted data 4Prepare data terminal 5Signal ground 6Prepare data set 7Send request 8Clear to send 9Ring indicator
Page 26
26 •RS232C cable Connector: 9-Pin D-Sub Cable : Cross Cable 1 59 6-P1-6 95 1-P2- -P1- -P1- -P2--P2- Female Rx Tx Gnd2 3 5 -------->
Page 27
27 •Connector : RJ45 Direct LAN cable (PC to HUB) RJ45 RJ45 MDC HUB P1 P1 P2 P2 SignalP1P2Signal TX+11TX+ TX-22TX- RX+33RX+ RX-66RX- Cross LAN cable (PC to PC) RJ45P1 P2 SignalP1P2Signal TX+13RX+ TX-26RX- RX+31TX+ RX-62TX-
Page 28
28 Connection •Connection 1 RS232CIN OUTRS232CINOUTRS232CINOUTRS232CINOUT • Connection 2 RJ45RJ45 • Connection 3 RJ45RS232CIN OUTRS232CINOUTRS232CINOUTRS232C OUT
Page 29
29 Control Codes Viewing control state (Get control command) HeaderCommand IDData length Checksum 0xAA Command type 0 Controlling (Set control command) HeaderCommand IDData length DataChecksum 0xAA Command type 1Value Command No.Command type CommandValue range 1Power control 0x110~1 2Volume control 0x120~100 3Input source control 0x14- 4Screen mode control 0x18- 5Screen size control 0x190~255 6PIP on/off control 0x3C0~1 7Auto adjustment control (PC and BNC only) 0x3D 0 8Video wall mode control 0x5C0~1...
Page 30
30 Power control •Function A product can be powered on and off using a PC. •Viewing power state (Get Power ON / OFF Status) Header Command IDData length Checksum 0xAA 0x11 0 • Setting power ON/Off (Set Power ON / OFF) Header Command IDData length DataChecksum 0xAA 0x11 1"Power" "Power": Power code to be set on a product. 1: Power ON 0: Power OFF • Ack Header Command IDData length Ack/Nakr-CMDVal1Checksum 0xAA 0xFF 3'A'0x11"Power" "Power": Power code to be set...