3 Alignments and Adjustments
3-3 1. Calibration
2. Option Byte
3. W/B
4. VCTi
5. YC Delay
6. FLI5961
7. Adjust
8. Test Pattern
9. Chip Debugger
10. Check Sum
11. Spread Spectrum
12. HDCP
13. Reset
T-TRNPEU-0000 month day year time 
P-TRNPEU-0000
Panel On Time(Hour) 0000
5. YC Delay
RF PAL-B/G : 5
RF PAL-D/K : 6
RF PAL-I : 5
RF PAL-L/L : 5
RF SECAM-B/G : 2
RF SECAM-D/K : 0
RF SECAM-I : 2
RF SECAM-L/L : 0
RF NTSC 3.58 : 5
RF NTSC 4.43 : 5
AV PAL : 5
AV SECAM : 2
AV NTSC 3.58 : 5
AV NTSC 4.43 : 5
AV PAL 60...

Page 32

3 Alignments and Adjustments
3-4
3-3 White Balance - Calibration
3-3-2 White Balance - Adjustment
3-3-1 White Balance -Calibration
3-3-3 Conditions for Measurement
1. CalibrationDTV Calibration
PC Calibration
(Calibration Condition refer to next page)
3. W/B
(low light) (hight light)
1. On the basis of toshiba ABL pattern : High Light level (57 IRE)
- INPUT SIGNAL GENERATOR : MSPG-925LTH
* Mode NO 1 : 744X484@60 Hz
NO 6 : 1280X720@60 Hz (Component 720P)
NO 21 : 1024X768@60 Hz
* 
PatternNO 15 : Color bar...

Page 33

3 Alignments and Adjustments
3-5 2. Adjust the white balance of AV, Component and DVI Modes.
a) Set the input to the mode in which the adjustment will be made (AV          Component          DVI).
* Input signal - VIDEO Mode : Model #1 (744*484 Mode), Pattern #16
- Component, DVI Mode : Model #6 (1280*720 Mode), Pattern #16
b) Enter factory W/B.
c) Adjust the low light.
- Adjust sub - Brightness to set the Y value.
- Adjust red offset (x) and blue offset (y) to the color coordinates. ( x : 263, y : 267,...

Page 34

3 Alignments and Adjustments
3-6
Picture 4-4 Toshiba ABL Pattern
High light
Measurement point
d) Adjust the high light. (Refer to table 1, 2 in adjustment position by mode)
- Adjust red gain (x) and blue gain (y) to the color coordinates. ( x : 263, y : 267 )
* Do not adjust the green gain and sub-contrast (Y) data.
 

Page 35

3 Alignments and Adjustments
3-7
3-4 TORINO Micom Update
3-4-1 Installing G-Probe
1. Uncompress GProbe5.1.0.18.zip.
2. Run GProbe5.1.0.18.exe.
3. The files are created in the C:
Program FilesGenesis MicrochipGProbe 5 folder.
4. Copy the ispoak_spi.hex file to the C:
Program FilesGenesis MicrochipGProbe 5 folder.
5. Uncompress FLI5961-AC_GProbe_S0006-CSC-33B.zip.
6. Three files are extracted (FLI5961.Chip.GProbe, FLI5961.chm, outputlog.txt).
7. Copy all 3 files to the C:
Program FilesGenesis...

Page 36

3 Alignments and Adjustments
3-8
3-4-2 Connecting to the MAIN PCB
Switch off

Connect to the PCConnect to the MAIN PCB.

 

Page 37

3 Alignments and Adjustments
3-9
3-4-3 Update Procedures
1. Open mgm.txt in the C:Program FilesGenesis MicrochipGProbe 5 folder.
2. The following result will appear.
//
// Batch file to program a sPI serial flash using ISP.
// Moving the stack to high memory area is now taken care of in IROM
// through the Reset 0 command. Assumes the ISP driver is in the same
// directory as this file. Change ISP driver path in fastFlashWrite
// command, if different from current directory.
//
debugon
SetBuffer 0x2000...

Page 38

The Micom program is to be copied to the folder marked in red and the name of the program is to be the
same as the file name marked in blue.
(If the Micom program is not in the folder marked in red, change the path to the folder which includes the
Micom program and then save the file.)
3. When completing all the procedures above, connect the Jig and the PCB, and run the G-Probe program.
After that
Enter test 10 as shown in the following figure and press Enter or click the Execute button.
If the result...

Page 39

3 Alignments and Adjustments
3-11
4. Enter batch mgm.txt as show in the following figure and press Enter or click the Execute button to 
update Micom.
If the MICOM update is successfully completed, the 
above message appears.
 

Page 40

11  Disassembly and Reassembly
11-1
11 Disassembly and Reassembly
This section of the service manual describes the disassembly and reassembly procedures for the
LE23T51B/LE27T51B/LE32T51B TFT-LCD monitors.
WARNING: This monitor contains electrostatically sensitive devices. Use caution when handling
these components.
(ONLY LE32T51B) Check the connector of POWER BOARD which are CNM 802, 803.
IF Panel MARK is A(AUO), The wire which is from PANEL INVERTER Must be 
connected into CNM 803.
IF Panel MARK is...