    							5. Set a Keyboard for your computer.
    6.
    The next screen is for setting your monitor.
    7. First of all, set a horizontal frequency for your monitor. (You can ent\
    er the frequency
    directly.)
    8. Set a vertical frequency for your monitor. (You can enter the frequency\
     directly.)
    9. Enter the model name of your monitor. This information will not affect t\
    he actual execution
    of X-Window.
    10. You have finished setting up your monitor. Execute X-Window after settin\
    g other re-
    quested hardware. Using the Software 
    						
    							MDC Program Installation/Uninstallation
    Installation
    1Insert the installation CD into the CD-ROM drive.
    2Click the MDC Unified  installation program.
     If a software installation window is not displayed  on the main screen, install with the "MDC Unified" 
    execution file in the MDC folder on the CD.
     
    3Click "Next" in the displayed  Installation Wizard screen.
    4In the "License Agreement" window displayed, select "I accept the terms in the license agreement" 
    and click "Next".
    5In the displayed "Customer Informa tion" window, fill out all the information fields and click "Next".
    6In the displayed "Destination Folder" window, select the directory path you want to install the 
    program in and click "Next".
     If the directory path is not specified, the program  will be installed in the default directory path. 
    7In the displayed "Ready to Install the Program" window, check the directory path to install the 
    program in and click "Install".
    8Installation progress  will be displayed.
    9Click "Finish" in the displayed "InstallShield Wizard Complete" window.
     Select "Launch MDC Unified" and click "Fin ish" to run the MDC program immediately. 
    10The MDC Unified shortcut icon will be created on the desktop after installation.
     The MDC execution icon may not be displayed  depending on the PC system or product 
    specifications.
    Press F5 if the execution icon is not displayed. 
    Uninstallation
    1Select  Settings  > Control Panel  on the Start menu and double-click  Add/Delete Program.
    2Select MDC Unified  from the list and click Change/Remove.
     MDC installation can be affected by the graphics card, mother board and network conditions.  
    						
    							Connecting to MDC
    Using MDC via RS-232C (serial data communications standards)
    An RS-232C serial cable must be connected to the serial ports on the PC and monitor.
    What is MDC?
    Multiple display control "MDC" is an application that allows you to easily control multiple display devices 
    simultaneously using a PC. 
    						
    							Using MDC via Ethernet
    Enter the IP for the primary display device and connect the device to the PC. One display device can 
    connect to another using an RS-232C serial cable. 
    						
    							Connection Management
    Connection management includes the Connection list and Connection list modification options.
    Connection list – Connection list shows the details of the connections such as connection setting (IP/
    COM, Port No, MAC, and Connection Type), connection status, Set ID Range, and detected devices. 
    Each connection can contain a maximum of 100 devices connected in serial daisy-chain fashion. All the 
    LFDs detected in a connection are displayed in the Device list, where the user can make groups and 
    send commands to detected devices.
    Connection list modification options – Connection modification options includes Add, Edit, Delete, 
    and Refresh. 
    						
    							Auto Set ID
    Auto Set ID feature assigns a Set ID for all the LFDs connected in daisy-chain of a selected connection. 
    There can be a maximum of 100 LFDs in a connection. The Set ID is assigned sequentially in the daisy-
    chain running from 1 to 99, and then finally to Set ID 0.
    Cloning
    Using the Cloning feature, you can copy the setting of one LFD and apply it to multiple selected LFDs. 
    You can select specific tab categories or all tab categories for cloning, using the copy setting option 
    window.  
    						
    							Command Retry
    This feature is used to specify the maximum number of times the MDC command will be retried in case of 
    there being no reply or a corrupted reply from an LFD. The retry count value can be set using the MDC 
    options window. The retry count value must be between 1-10. The default value is 1.  
    						
    							Getting Started with MDC
    1To start the program, click Start  Programs  Samsung  MDC Unified.
    2Click Add to add a display device.
    If the connection is established via RS232C, go to Serial and specify the COM Port.  
    						