Installation Runco VX-6000d Owner’s Operating Manual 29 PREL IMINARY Install Ceiling Mount Extension Brackets (CineWide with AutoScope) If you are installing an AutoScope-equipped VX-6000d, use the supplied hardware to attach the ceiling mount extension brackets to the bottom of the projector as shown in Figure 3-7. For ceiling installations, these brackets bring the mounting points for the projector mounting plate (included with the ceiling mount kit) from the bottom of the projector up and around the lens motor housing. For floor installations (where the projector is upright), the brackets allow the projector to lie flat on the mounting surface. Figure 3-7. VX-6000d With Ceiling Mount Extension Brackets Ceiling Mount Extension Brackets
Installation 30 Runco VX-6000d Owner’s Operating Manual PREL IMINARY 3.5 Mounting the VX-6000d There are several methods for mounting the projector. Depending on your chosen installation, one method may be more suitable than another. Floor Mounting (Upright)In typical front and rear screen installations, the projector can be mounted to a secure and level surface such as a table or cart. Carts are useful when moving a projector during a presentation or from site to site. If possible, lock the wheels when it’s in position to prevent it from being moved during a presentation. Ceiling Mounting (Inverted) For fixed installations, and for those that want the projector out of sight or have a limited space for projector and audience, you can invert the VX-6000d and suspend it from the ceiling using a specially-designed ceiling mount fixture. The projector can also be inverted and placed in an enclosure above and behind the viewing area. Install four feet on the inside bottom surface of the enclosure on which the projector can rest. A variety of materials can be used for this purpose (for example, rubber crutch tips or turntable feet). Adjusting the Projection Angle If the VX-6000d is ceiling-mounted and the screen is significantly lower than the projector, you can tilt the projector at a slight angle by adjusting the ceiling mount. If you do this, you may need to shift the image or apply keystone correction using the OSD controls, to compensate. For detailed instructions, refer to Using the On-Screen Menus on page 49. 3.6 Connections to the VX-6000d and DHD Controller Proceed as follows to connect the DHD Controller to the VX-6000d, your video sources, external controller(s) – if present – and AC power. When connecting your equipment: Turn off all equipment before making any connections. Use the correct signal cables for each source. Route all cables through the cable opening at the bottom rear of the projector (see Figure 2-1). Ensure that the cables are securely connected. Tighten the thumbscrews on connectors that have them. Connecting the DHD Controller to the VX-6000d The VX-6000d is designed to receive only video input signals directly from the companion DHD Controller/Processor. All signal sources should be connected to the appropriate inputs on the rear panel of the DHD. The signal from the DHD is then output to the VX-6000d projector through an RGB or DVI cable. ➤ ➤ Use only the Runco-approved ceiling mount kit designed for your projector. Install the mount kit according to the instructions provided with it. Note ➤ ➤ You CANNOT connect signal sources directly to the VX-6000d. They MUST be routed through the DHD Controller for proper operation.Note
Installation Runco VX-6000d Owner’s Operating Manual 31 PREL IMINARY Connect the HDMI and RS-232 outputs of the DHD Controller to the corresponding inputs of the VX-6000d; see Figure 3-8. Figure 3-8. Connecting the VX-6000d to the DHD Controller RS-232C WIRED IR +12V 100-240V AC INPUTHDMI IN Pb Pr Y Video3 IR RS-232 Control S-Video 1 S-Video 2 HD1 HD212 R/Pr G/Y B/Pb R/Pr G/Y B/Pb H V HDMI 1 HDMI 2 HDMI OutHVTRIGGERS RS-232 OutCAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER. NO USER- SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE CENTER. AVIS: RISQUE DE CHOC ELECTRIQUE-NE PAS OUVRIRCAUTIONRISK OF ELECTRIC SHOCK DO NOT OPEN! WA R N I N G : TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE. 100-230VAC 50-60 Hz, 165 Watts Max INPUTSSYSTEM CONTROL INTERFACE Component Video SDI Option Serial No Video Processor / ControllerModel Runco International Union City, CA Made In USA RS-232 OUT HDMI OUT
Installation 32 Runco VX-6000d Owner’s Operating Manual PREL IMINARY Connecting Source Components to the DHD Controller Connect your video sources to the DHD Controller as shown and described in the sections that follow. HDMI Connections: See Figure 3-9. Figure 3-9. HDMI Source Connections ➤ Use the HDMI inputs whenever possible. This ensures the highest video quality because the signal is carried in the digital domain throughout the entire signal path, from source component output into the projector. Tip HD1 HD2 G/YINPUTS HV R/Pr B/PbG/Y H V R/Pr B/Pb Component Video Pb Pr Y Video S-Video 2S-Video 1IR 12 3TRIGGERS HDMI 1 HDMI 2 HDMI Source (HD-DVD/BD/DVD Player or HD Tuner with HDMI or DVI out)
Installation Runco VX-6000d Owner’s Operating Manual 33 PREL IMINARY Digital (DTV) RGB or Component Video Connections: See Figure 3-10. Figure 3-10. Digital (DTV) RGB or Component Video Connections HD1 HD2 G/YINPUTS HV R/Pr B/PbG/Y H V R/Pr B/Pb Component Video Pb Pr YVideo S-Video 2 S-Video 1 12 3TRIGGERS HDMI 1 HDMI 2 DTV or Progressive Component (YPbPr) Source Red/Pr Green/Y Blue/Pb Horiz Vert
Installation 34 Runco VX-6000d Owner’s Operating Manual PREL IMINARY Analog (Computer) RGB Connections: See Figure 3-11. Figure 3-11. Analog RGB Connections HD1 HD2 G/YINPUTS HV R/Pr B/PbG/Y H V R/Pr B/Pb Component Video Pb PrY Video S-Video 2S-Video 1 12 3TRIGGERS HDMI 1 HDMI 2 Personal Computer Red Green Blue Horiz Vert
Installation Runco VX-6000d Owner’s Operating Manual 35 PREL IMINARY Composite/S-Video/Component Video Connections: See Figure 3-12. Figure 3-12. Composite, S-Video and Component Video Connections HD1 HD2 G/YINPUTS HV R/Pr B/PbG/Y H V R/Pr B/Pb Component Video Pb PrY Video S-Video 2S-Video 1 12 3TRIGGERS HDMI 1 HDMI 2 DVD Player, VCR, Satellite Receiver, Laser Disc etc. Pb Pr Y
Installation 36 Runco VX-6000d Owner’s Operating Manual PREL IMINARY RS-232 Controller Connection Use a standard, 9-pin RS-232 cable to connect a PC or home theater control/automation system (if present) to the RS-232 Control port on the DHD Controller; see Figure 3-13. For more information about using this connection, refer to Serial Communications on page 79. Figure 3-13. RS-232 Control System Connection ➤ Pb Pr Y Video3 IR RS-232 Control S-Video 1 S-Video 2 12 TRIGGERS RS-232 Out Component Video12345 7896 to Automation/ Control System or PC 2 Transmit Data 3 Receive Data 5 Ground (none of the other pins are used)
Installation Runco VX-6000d Owner’s Operating Manual 37 PREL IMINARY Connecting 12-Volt Trigger Outputs to External Theater Equipment DHD Controller: If your VX-6000d is equipped with a CineWide with AutoScope system, connect the AutoScope lens motor to a 12-volt trigger output on the DHD Controller; see Figure 3-14. Similarly connect other 12-volt trigger-activated equipment (such as retractable screens or screen masks) to the other trigger outputs. For more information on using the DHD Controller triggers, refer to Triggers on page 63. Figure 3-14. 12-volt Trigger Output Connections (from DHD Controller) Tip = +12V Sleeve = Ground Pb Pr Y Video3 IR RS-232 Control S-Video 1 S-Video 2 HD1 HD212 R/Pr G/Y B/Pb R/Pr G/Y B/Pb H V DVI 1 DVI 2 DVI Out H/V V H R/Pr G/Y B/PbHVTRIGGERS RS-232 OutCAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER. NO USER- SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE CENTER. AV I S : RISQUE DE CHOC ELECTRIQUE-NE PAS OUVRIR CAUTIONRISK OF ELECTRIC SHOCK DO NOT OPEN! WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE. 100-230VAC 50-60 Hz, 165 Watts Max OUTPUTSINPUTS SYSTEM CONTROL INTERFACE Component Video SDI Option Serial No Video Processor / ControllerModel Runco International Union City, CA Made In USA DHD Controller Rear Panel AutoScope Lens Motor (Rear) 3.5-mm mini plug AC Input Power Switch Retractable Screen or other 12-volt trigger-activated device
Installation 38 Runco VX-6000d Owner’s Operating Manual PREL IMINARY Projector: The projector is equipped with an additional 12-volt trigger output. This trigger activates when the projector is turned on. Connect it to your retractable screen or other, 12-volt trigger-activated equipment as shown in Figure 3-15. Figure 3-15. 12-volt Trigger Output Connection (from Projector) Connecting an External IR Receiver to the DHD Controller If infrared signals from the remote control cannot reach the DHD Controller due to excessive distance or obstructions such as walls or cabinet doors, you can connect an external IR receiver to the DHD Controller to extend the range of the remote control. See Figure 3-16. Figure 3-16. External IR Receiver Connection RS-232C WIRED IR +12V 100-240V AC INPUTHDMI IN to retractable screen or other, 12-volt trigger-activated equipmentTip = +12V Sleeve = Ground(cylindrical, DC power supply-type plug) ➤ When an external IR receiver is connected to the wired IR input, the built-in IR sensor on the DHD Controller is disabled. Pb Pr Y Video3 IR RS-232 Control S-Video 1 S-Video 2 12 TRIGGERS RS-232 Out Component Video Ring = +5V Tip = IR Input Sleeve = Ground (3.5-mm mini phono plug) IR Receiver Remote Control Note