Runco VX-6000d Owner’s Operating Manual 79 PREL IMINARY 6.1 RS-232 Connection and Port Configuration To interface the DHD Controller with a home theater automation/control system or a PC running terminal emulation software, connect it to your control system or PC as shown in Figure 3-13. Configure the RS-232 controller or PC serial port as follows: no parity, 8 data bits, 1 stop bit and no flow control. Set the baud rate to 19200, to match that of the DHD Controller RS-232 port. 6.2 Serial Command Syntax Serial commands to the DHD Controller take the following form: Commands are not case-sensitive. For a single command that takes no parameters, type the command followed by a carriage return; for example, to set the aspect ratio to Letterbox, type LETTERBOX . For a single command that takes a parameter, type the command, a space or a comma and the desired value followed by a carriage return; for example, to set the brightness to -10, type BRIGHTNESS -10 or BRIGHTNESS,-10 . You can also send a string of multiple commands on a single line, separated by commas. For example, COMPOSITE,BRIGHTNESS 100,ANAMORPHIC switches to the Composite video input, sets the brightness to 100 and sets the aspect ratio to Anamorphic. Command strings can be up to 255 characters long. Table 6-1 lists the RS-232 command set. The “Parameter (min/max)” column shows the valid parameter ranges, or “NA” for commands that take no parameters. When you enter a valid command, the DHD Controller executes it and acknowledges it with a plus sign on the command line (+ >). When you enter an invalid command -- one that is misspelled or followed by values outside the valid range for that command -- the DHD Controller ignores it and returns a minus sign (- >). 6. Serial Communications Avoid combining the ON or POWER 1 commands with other commands on a single line. After sending ON or POWER 1, allow at least 15 seconds for the DHD Controller to power up. Once it does, it will accept and properly execute multiple serial commands. Table 6-1. Serial Commands CommandParameter (min/max)Value Stored?Description Power On/Off Commands OFFNANATurns projector off ONNANATurns projector on POWER0/1NATurns projector on and off POWER?NANAReturns power status Note
Serial Communications 80 Runco VX-6000d Owner’s Operating Manual PREL IMINARY Input Selection Commands COMPONENTNAYESSelects the Component input COMPOSITENAYESSelects the Composite video input HDMI1NAYESSelects the HDMI 1 input HDMI2NAYESSelects the HDMI 2 input HD1NA YESSelects the RGB HD 1 input HD2NA YESSelects the RGB HD 2 input INPUT?NANAReturns active input SVIDEO1NAYESSelects the S-Video 1 input SVIDEO2NAYESSelects the S-Video 2 input Aspect Ratio Commands ANAMORPHICNAYESSelects the Anamorphic aspect ratio ASPECT?NANAReturns current aspect ratio ASPECTIN?NANAReturns the input source aspect ratio ASPECTOUT?NANAReturns output screen size CINEMANAYESSelects the Cinema aspect ratio LETTERBOXNAYESSelects the Letterbox aspect ratio STANDARDNAYESSelects the Standard (4:3) aspect ratio VIRTUALWIDENAYESSelects the VirtualWide aspect ratio VIRTUAL235NAYESSelects the Virtualwide 2.35 aspect ratio (available only on the VX-6000d/CineWide and only on the analog inputs) OUT169NAYESSets the output screen to 1.78:1 (16:9) OUT235NAYESSets the output screen to 2.35:1 Table 6-1. Serial Commands (continued) CommandParameter (min/max)Value Stored?Description
Serial Communications Runco VX-6000d Owner’s Operating Manual 81 PREL IMINARY Picture Adjust Commands (not available on HDMI 1 or HDMI 2 inputs) BRIGHTNESS-100/100YESSets a value for brightness BRIGHTNESS?NANAReturns brightness setting value CHROMADELAY-12/12YESSets a value for input color chroma delay CHROMADELAY?NANAReturns input color chroma delay setting COLOR-100/100YESSets a value for color COLOR?NANAReturns color setting value CONTRAST-100/100YESSets a value for contrast CONTRAST?NANAReturns contrast setting value FILMMODE0/1YESSets Film Mode off (0) or on (1) FILMMODE?NANAReturns Film Mode setting (0 = off; 1 = on) FILTER0/15YESSets a value for input color noise filter FILTER?NANAReturns input color noise filter setting PHASE0/3YESAdjusts phase PHASE?NANAReturns phase setting value SHARPNESS-6/6YESSets a value for sharpness SHARPNESS?NANAReturns sharpness setting value TINT-100/100YESSets a value for tint TINT?NANAReturns tint setting value Image Preset Commands (not available on HDMI 1 or HDMI 2 inputs) CUSTOM1NAYESLoads “Custom 1” image preset CUSTOM2NAYESLoads “Custom 2” image preset DAYNAYESLoads “ISF Day” image preset NIGHTNAYESLoads “ISF Night” image preset PRESET?NANAReturns currently-selected preset (ISF Day, ISF Night, Custom 1 or Custom 2) Table 6-1. Serial Commands (continued) CommandParameter (min/max)Value Stored?Description
Serial Communications 82 Runco VX-6000d Owner’s Operating Manual PREL IMINARY Input Position Commands (not available on HDMI 1 or HDMI 2 inputs) IHEIGHT-100/100YESSets the value for input height IHEIGHT?NANAReturns input height value IHPOS-100/100YESSets a value for horizontal input position IHPOS?NANAReturns input horizontal position value IVPOS-100/100YESSets a value for vertical input position IVPOS?NANAReturns input vertical position value IWIDTH-100/100YESSets the value for input width IWIDTH?NANAReturns input horizontal width value OVERSCAN 0/10YESSets the overscan percentage OVERSCAN?NANAReturns overscan percentage Output Shift Commands (not available on HDMI 1 or HDMI 2 inputs) OHEIGHT-100/100YESSets the value for output height OHEIGHT?NANAReturns output height value OHPOS-100/100YESSets the value for output horizontal position OHPOS?NANAReturns output horizontal position value OVPOS-100/100YESSets the value for output vertical position OVPOS?NANAReturns output vertical position value OWIDTH-100/100YESSets the value for output width OWIDTH?NANAReturns output horizontal width value Table 6-1. Serial Commands (continued) CommandParameter (min/max)Value Stored?Description
Serial Communications Runco VX-6000d Owner’s Operating Manual 83 PREL IMINARY Miscellaneous Commands BKGND-100/100YESSets the background color for 4:3 aspect ratio (-100 = black; 100 = white) BKGND?NANAReturns background setting value DATE?NANAReturns projector manufacture date HDINPUTRESNAYESSets YPbPr input resolution and refresh rate for HD1/HD2, as follows: 0 = 480i 1 = 480p 2 = 576i 3 = 576p 4 = 720p / 60 Hz 5 = 1080i / 60 Hz 6 = 720p / 50 Hz 7 = 1080i / 25 Hz Any other value = Auto HWVER?NANAReturns hardware version number INRES?NANAReturns input resolution LENS1?NANAReturns Lens 1 configuration LENS2?NANAReturns Lens 2 configuration OUTRES0/5YESSets output resolution, as follows: 0 = 480i 1 = 576i 2 = 480p 3 = 576p 4 = 720p 5 = 1080i OUTRES?NANAReturns output resolution RGBNNNANASets output color space to RGB with negative horizontal and vertical sync RGBPPNANASets output color space to RGB with positive horizontal and vertical sync RGBSNANASets output color space to RGB with composite sync STATUSNANAReturns current operating status (power, input source, input resolution and input aspect ratio) SWVER?NANAReturns software version number TRIGGER1/3YESAssigns trigger to currently-selected aspect ratio Table 6-1. Serial Commands (continued) CommandParameter (min/max)Value Stored?Description
Serial Communications 84 Runco VX-6000d Owner’s Operating Manual PREL IMINARY The following serial commands are meant to emulate buttons on the remote control or DHD Con- troller front panel. Each button has its own serial command, so effectively it is as if you were using the IR remote only you’ll be doing so via serial commands. These commands provide active OSD responses just like the IR remote. DOWNNANADown-Arrow () key ENTERNANAENTER key LEFTNANALeft-Arrow () key MENUNANAMENU RIGHTNANARight-Arrow () key UPNANAUp-Arrow () key Table 6-1. Serial Commands (continued) CommandParameter (min/max)Value Stored?Description
Runco VX-6000d Owner’s Operating Manual 85 PREL IMINARY 7.1 VX-6000d Specifications Table 7-1 lists the VX-6000d specifications. 7. Specifications Table 7-1. VX-6000d Specifications Projector Type:Digital Light Processing (DLP), single-chip, 16:9 SuperOnyx™ DMD Native Resolution:1920 x 1080 (16:9) Aspect Ratios:Refer to Table 7-2 Video Standards:Refer to Table 7-2 DTV Compatibility:480p, 720p, 1080i, 1080p Scan Frequency:Horizontal: 15 - 81 kHz Vertical: 43 - 100 Hz Picture Size (16:9 Screen):Recommended Width: 72 - 96 in. Maximum Width: 200 in. Throw Distance (Factor x Screen Width):Refer to Table 3-3 Horizontal and Vertical Offset:Refer to Table 3-4 Lamp:220 Watts Estimated Lamp Life: 2000 hours Inputs (from DHD Controller): (1) HDMI with HDCP, (1) RS-232
Specifications 86 Runco VX-6000d Owner’s Operating Manual PRELI MINARY Brightness and Contrast (variable, depending on RVR calibration):Cinema Standards Measurement System (CSMS) Specifications - Brightness: 17.2 to 29.7 foot-Lamberts (fL) - Contrast Ratio: 232:1 to 255:1 These measurements are taken from the projector in a controlled, home theater environment. All measurements are made to ANSI/NAPM IT7.228-1997 specifications using the Photo Research PR-650 SpectraColorimeter and Minolta LS-100 Luminance Meter, Video Essentials test DVD and a 1.3 gain, 72-inch wide screen. The projector is calibrated to a color temperature of 6,500K and has a minimum of 150 hours of usage. The foot-Lambert (fL) is the unit of measurement used in commercial movie theaters to express image brightness at the screen surface. The Society of Motion Picture and Television Engineers (SMPTE) specifies 16 fL as the target image brightness for film-based projectors using an open gate (without film in the projector). More importantly, today SMPTE specifies 12 fL as the target image brightness in Digital Cinema theaters. The foot-Lambert measurement is dependent on screen size, screen gain and projector light output. Home Theater Calibration Specifications - Light Output: 462 to 796 ANSI Lumens - Contrast Ratio: 232:1 to 255:1 These specifications are obtained by calibrating the projector as described above for CSMS measurements. Industry-Standard Specifications - Light Output: 1700 ANSI Lumens - Contrast Ratio: 4400:1 to 5000:1 These are typical projector brightness and contrast specifications found in most companies’ sales literature. Runco includes these measurements in its literature to allow for direct comparison with other manufacturers’ projectors. These measurements are typically taken at 9,000K to 13,000K to get expected performance data when the projector is used in professional, commercial and industrial displays. Power Requirements: 100 to 240 VAC (auto-sensing), 50/60 Hz, 380 Watts Operating Environment:40°F to 95°F (5°C to 35°C), 0% to 90% humidity (non-condensing) Dimensions:See Figure 7-1 Weight (without lens):73 lbs. (33.11 kg) Regulatory Approvals:Complies with FCC, CE C-Tick Limited Warranty: Projector: Two (2) years parts and labor from the date of delivery to the end user. Lamp: 1000 hours or six (6) months, whichever comes first. Specifications are subject to change without notice. Table 7-1. VX-6000d Specifications (continued)
Specifications Runco VX-6000d Owner’s Operating Manual 87 PREL IMINARY 7.2 DHD Controller Specifications Table 7-2 lists the DHD Controller specifications. Table 7-2. DHD Controller Specifications Aspect Ratios: 4:3, Letterbox, 16:9 Anamorphic, VirtualWide, Cinema, VirtualWide 2.35 Video Standards:NTSC, PAL Output Resolution:720p Inputs: (1) Composite; (2) S-Video; (1) Component; (2) HD-R (Pr), G (Y), B (Pb), H, V; (2) DVI with HDCP Outputs: (1) HD/RGBHV (1) DVI-I with HDCP Control Options:- Discrete infrared remote - Serial commands via RS-232 - Front-panel controls RS-232 Communication Parameters: 19200 bps, no parity, 8 data bits, 1 stop bit, no flow control Trigger Outputs: (3) +12 VDC, each rated at 750 mA and thermal fuse-protected Bandwidth:150 Mega Samples per Second (MSPS) Power Requirements: 100 to 240 VAC (auto-sensing), 50/60 Hz, 160 Watts Operating Environment:40°F to 95°F (5°C to 35°C), 0% to 90% humidity (non-condensing) Dimensions:Width = 17.50 inches (444.5 mm) Depth = 11.19 inches (284.1 mm) Height = 3.75 inches (95.3 mm) Weight: 13.0 lbs. (5.90 kg) Regulatory Approvals:Complies with FCC, CE C-Tick Limited Warranty: Two (2) years parts and labor from the date of delivery to the end user. Specifications are subject to change without notice.
Specifications 88 Runco VX-6000d Owner’s Operating Manual PRELI MINARY 7.3 VX-6000d Dimensions Figure 7-1 shows the VX-6000d dimensions (all dimensions are in inches). Figure 7-1. VX-6000d Dimensions 0 4.895 12.379 20.870 26.304 8.935 8.185 1.015 0 2.235 5.036 (3x) 15.012 (3x) 18.635 0 24.069 15.591 (2x) 11.341 (2x) 7.091 (2x) 2.23527.804 8.629 Front Jewelry opening dia. Ø 6.475 Front ViewTop View Side View Bottom View