Page 71
Installation Runco VX-44d/-55d Owner’s Operating Manual 59 PREL IMINARY Lamp Mode: Select the Lamp Mode you want to use in order to control the light output. You can choose to run the lamp as bright as possible, you can power the lamp with a specific wattage appropriate for the installed lamp or you can set a specific intensity (brightness) to maintain. Keep in mind that higher lamp power settings can shorten lamp life. Use the lamp mode that best suits your brightness needs: Max Brightness: The...
Page 72
Installation 60 Runco VX-44d/-55d Owner’s Operating Manual PREL IMINARY For example, a 1000-Watt lamp can be driven at no more than 1000 Watts. To produce desired brightness at the screen, a new lamp would likely need less than this maximum rating — perhaps 812 Watts (example only). Over time, however, the lamp requires more and more current in order to generate the desired light, until eventually the lamp wattage reaches its 1000-Watt maximum and the lamp power automatically levels off. At this...
Page 73
Runco VX-44d/-55d Owner’s Operating Manual 61 PREL IMINARY 4.1 Using the On-Screen Menus Press the MENU button on either the remote control or the DHD Controller front panel to display the Main Menu. To select a menu item, use the and buttons on either the remote control or the DHD Controller front panel to highlight it. Press ENTER to confirm your selection. The VX-44d/-55d OSD menus are arranged hierarchically, as shown in Figure 4-1. Depending on the selected input source and signal...
Page 74
Operation 62 Runco VX-44d/-55d Owner’s Operating Manual PREL IMINARY Figure 4-1. DHD Controller OSD Menu Structure for VX-44d/-55d Service Test VideoGrey Bars 1 Grey Bars 2 Color Bars 1 Color Bars 2 Input Names Rename, Restore or Save Remote ControlPrimary Secondary Analog Out Mode RGB--, RGB++ or RGBS Display Device: ConfigureInstallationPicture Orientation Keystone Lamp Hours (read-only) LensFocus Zoom Shift Auto Setup Digital Bypass HD FormatHD/RGB 1 Auto, RGB or YUV HD/RGB 2 ADC Bandwidth Auto, 75...
Page 75
Operation Runco VX-44d/-55d Owner’s Operating Manual 63 PREL IMINARY Main MenuThe Main Menu is the starting point for accessing all projector functions. (The Calibration and Service menus are hidden and not accessible until you enter a passcode.) Input SourceFrom the Main Menu, select Input Source to choose a video signal source. The active source is indicated by an arrow (>) to its left; in the example at left, Composite is the active source. Aspect Ratio To change the aspect ratio (size and...
Page 76
Operation 64 Runco VX-44d/-55d Owner’s Operating Manual PREL IMINARY Table 4-1. Aspect Ratio Settings Aspect Ratio Remote Control Key Description AnamorphicANASelect Anamorphic to view 16:9 DVDs and HDTV programs in their native aspect ratio. 4:3 images are stretched horizontally to fit a 16:9 screen. Standard 4:34X3Standard 4:3 scales the input signal to fit in the center of the 16:9 screen. 4:3 is the aspect ratio used by computer monitors, standard television programming and most VHS...
Page 77
Operation Runco VX-44d/-55d Owner’s Operating Manual 65 PREL IMINARY VirtualWideV-WIDEVirtualWide scales a 4:3 image NON-linearly (more on the sides than in the center) to fit a 16:9 screen. On a 2.35:1 screen, the image is centered between black bars on either side. CinemaCINEMASelect Cinema to view 2.35 source material in its native aspect ratio. With a 16:9 screen and a non-CineWide projector (no anamorphic lens), the upper and lower portions of the screen are masked,...
Page 78
Operation 66 Runco VX-44d/-55d Owner’s Operating Manual PREL IMINARY PictureUse the controls in the Picture Menu to calibrate your VX-44d/-55d for optimum picture quality. The VX-44d/-55d has been designed to incorporate setup and calibration standards established by the Imaging Science Foundation (ISF). The ISF has developed carefully crafted, industry-recognized standards for optimal video performance and has implemented a training program for technicians and installers to use these standards to...
Page 79
Operation Runco VX-44d/-55d Owner’s Operating Manual 67 PREL IMINARY Brightness: On your external test pattern source, select a PLUGE pattern. (PLUGE is an acronym for “Picture Line-Up Generation Equipment.”) Figure 4-2 shows a typical PLUGE pattern. Figure 4-2. Typical PLUGE Pattern for Adjusting Brightness PLUGE patterns vary but generally consist of some combination of black, white and gray areas against a black background. The example above includes two vertical bars and four shaded boxes....
Page 80
Operation 68 Runco VX-44d/-55d Owner’s Operating Manual PREL IMINARY Contrast: On your external test pattern source, select a stepped, gray-bar pattern like the one shown in Figure 4-3. Figure 4-3. Typical Gray Bar Pattern for Adjusting Contrast Select Contrast and press ENTER. Adjust the contrast to a point just below which the white rectangle starts to increase in size. Color Saturation: On your external test pattern source, select a color bar pattern like the one shown in Figure 4-4. Figure...