Serial Communications Runco VX-2000d Owner’s Operating Manual 69 PREL IMINARY Miscellaneous Commands BKGND-100/100YESSets the background color for 4:3 aspect ratio (-100 = black; 100 = white) BKGND?NANAReturns background setting value DATE?NANAReturns projector manufacture date DISPLAY1YESSets display device input source (Always 1) DISPLAY?NANAReturns display device input source value HDINPUTRESNAYESSets YPbPr input resolution and refresh rate for HD1/HD2, as follows: 0 = 480i 1 = 480p 2 = 576i 3 = 576p 4 = 720p / 60 Hz 5 = 1080i / 60 Hz 6 = 720p / 50 Hz 7 = 1080i / 25 Hz Any other value = Auto HWVER?NANAReturns hardware version number INRES?NANAReturns input resolution LENS1?NANAReturns Lens 1 configuration OUTRES0/5YESSets output resolution, as follows: 0 = 480i 1 = 576i 2 = 480p 3 = 576p 4 = 720p 5 = 1080i OUTRES?NANAReturns output resolution RGBNNNANASets output color space to RGB with negative horizontal and vertical sync RGBPPNANASets output color space to RGB with positive horizontal and vertical sync RGBSNANASets output color space to RGB with composite sync STATUSNANAReturns current operating status (power, input source, input resolution and input aspect ratio) SWVER?NANAReturns software version number Table 6-1. Serial Commands (continued) CommandParameter (min/max)Value Stored?Description
Serial Communications 70 Runco VX-2000d Owner’s Operating Manual PREL IMINARY TRIGGER1/3YESAssigns trigger to currently-selected aspect ratio The following serial commands are meant to emulate buttons on the remote control or DHD Con- troller front panel. Each button has its own serial command, so effectively it is as if you were using the IR remote only you’ll be doing so via serial commands. These commands provide active OSD responses just like the IR remote. DOWNNANADown-Arrow () key ENTERNANAENTER key LEFTNANALeft-Arrow () key MENUNANAMENU RIGHTNANARight-Arrow () key UPNANAUp-Arrow () key Table 6-1. Serial Commands (continued) CommandParameter (min/max)Value Stored?Description
Runco VX-2000d Owner’s Operating Manual 71 PREL IMINARY 7.1 VX-2000d Specifications Table 7-1 lists the VX-2000d specifications. 7. Specifications Table 7-1. VX-2000d Specifications Projector Type:Digital Light Processing (DLP), single-chip, 16:9 SuperOnyx™ DMD Native Resolution:1920 x 1080 (16:9) Aspect Ratios:Refer to Table 7-2 Video Standards:Refer to Table 7-2 DTV Compatibility:480p, 720p, 1080i, 1080p Scan Frequency:Horizontal: 15 - 81 kHz Vertical: 43 - 100 Hz Picture Size (16:9 Screen):Recommended Width: 72 - 96 in. Maximum Width: 200 in. Throw Distance (Factor x Screen Width):VX-2000d: 1.84 to 2.47 VX-2000d/CineWide: 1.90 to 2.47 Horizontal and Vertical Offset:Horizontal: None Vertical: 50% of screen height up or down Lamp:220 Watts Estimated Lamp Life: 2000 hours Inputs (from DHD Controller): (1) HDMI with HDCP, (1) RS-232
Specifications 72 Runco VX-2000d Owner’s Operating Manual PRELI MINARY Brightness and Contrast (variable, depending on RVR calibration):Cinema Standards Measurement System (CSMS) Specifications - Brightness: 15.6 to 22.4 foot-Lamberts (fL) - Contrast Ratio: 211:1 to 229:1 These measurements are taken from the projector in a controlled, home theater environment. All measurements are made to ANSI/NAPM IT7.228-1997 specifications using the Photo Research PR-650 SpectraColorimeter and Minolta LS-100 Luminance Meter, Video Essentials test DVD and a 1.3 gain, 72-inch wide screen. The projector is calibrated to a color temperature of 6,500K and has a minimum of 150 hours of usage. The foot-Lambert (fL) is the unit of measurement used in commercial movie theaters to express image brightness at the screen surface. The Society of Motion Picture and Television Engineers (SMPTE) specifies 16 fL as the target image brightness for film-based projectors using an open gate (without film in the projector). More importantly, today SMPTE specifies 12 fL as the target image brightness in Digital Cinema theaters. The foot-Lambert measurement is dependent on screen size, screen gain and projector light output. Home Theater Calibration Specifications - Light Output: 418 to 600 ANSI Lumens - Contrast Ratio: 211:1 to 229:1 These specifications are obtained by calibrating the projector as described above for CSMS measurements. Industry-Standard Specifications - Light Output: 1500 ANSI Lumens - Contrast Ratio: 2700:1 to 3300:1 These are typical projector brightness and contrast specifications found in most companies’ sales literature. Runco includes these measurements in its literature to allow for direct comparison with other manufacturers’ projectors. These measurements are typically taken at 9,000K to 13,000K to get expected performance data when the projector is used in professional, commercial and industrial displays. Power Requirements: 100 to 240 VAC (auto-sensing), 50/60 Hz, 375 Watts Operating Environment:40°F to 95°F (5°C to 35°C), 0% to 90% humidity (non-condensing) Dimensions:See Figure 7-1 Weight (without lens):50 lbs. (22.68 kg) Regulatory Approvals:Complies with FCC, CE C-Tick Limited Warranty: Projector: Two (2) years parts and labor from the date of delivery to the end user. Lamp: 1000 hours or six (6) months, whichever comes first. Specifications are subject to change without notice. Table 7-1. VX-2000d Specifications (continued)
Specifications Runco VX-2000d Owner’s Operating Manual 73 PREL IMINARY 7.2 DHD Controller Specifications Table 7-2 lists the DHD Controller specifications. Table 7-2. DHD Controller Specifications Aspect Ratios: 4:3, Letterbox, 16:9 Anamorphic, VirtualWide, Cinema, VirtualWide 2.35 Video Standards:NTSC, PAL Inputs: (1) Composite; (2) S-Video; (1) Component; (2) HD-R (Pr), G (Y), B (Pb), H, V; (2) HDMI with HDCP Outputs: HDMI with HDCP Control Options:- Discrete infrared remote - Serial commands via RS-232 - Front-panel controls RS-232 Communication Parameters: 19200 bps, no parity, 8 data bits, 1 stop bit, no flow control Trigger Outputs: (3) +12 VDC, each rated at 750 mA and thermal fuse-protected Bandwidth:150 Mega Samples per Second (MSPS) Power Requirements: 100 to 240 VAC (auto-sensing), 50/60 Hz, 160 Watts Operating Environment:40°F to 95°F (5°C to 35°C), 0% to 90% humidity (non-condensing) Dimensions:Width = 17.50 inches (444.5 mm) Depth = 11.19 inches (284.1 mm) Height = 3.75 inches (95.3 mm) Weight: 13.0 lbs. (5.90 kg) Regulatory Approvals:Complies with FCC, CE C-Tick Limited Warranty: Two (2) years parts and labor from the date of delivery to the end user. Specifications are subject to change without notice.
Specifications 74 Runco VX-2000d Owner’s Operating Manual PRELI MINARY 7.3 VX-2000d Dimensions Figure 7-1 shows the VX-2000d dimensions (all dimensions are in inches). Figure 7-1. VX-2000d Dimensions 6.435 7.185 7.450 R 10.68021.665 20.16520.870 0 2.235 5.858 (3x) 15.834 (3x) 18.635 0 2.235 7.340 (2x) 11.590 (2x) 15.840 (2x)17.930R 10.680 Ø 1.140