Page 61

Operation
Vistage™ Series Flat-Panel Display Installation/Operation Manual 47 
PREL
IMINARY
Splash Timer: When you turn on the V-50HD/V-63HD, it projects a welcome screen 
with the Runco and ISF logos, along with the personalized information you enter as 
described above. Select Splash Timer from the Splash Configure menu to set the 
amount of time for which this screen appears. The range is from 5 to 60 seconds, in 
one-second increments. Press   or   to set the timer, then press MENU.
Splash Enable:...

Page 62

Operation
48 Vistage™ Series Flat-Panel Display Installation/Operation Manual
PREL
IMINARY
Press MENU to exit test pattern mode. 
Input Names: You can give each input a descriptive name. For example, you may want 
to change the default input name to the type of source component connected to it: 
“VCR,” “DVD,” “Laptop” et cetera. Input names can be up to 12 characters long. 
To edit an input name, select Input Names from the Service menu. Press   or   to select 
an input and press ENTER. Use the   or...

Page 63

Operation
Vistage™ Series Flat-Panel Display Installation/Operation Manual 49 
PREL
IMINARY
DHCP: To enable the DHCP client in the DHD Controller, select DHCP from the IP 
Configuration menu and set it to On. With this setting, the DHD Controller’s IP 
address, subnet mask and default gateway are assigned by the local DHCP server. 
To manually configure these values, set DHCP to Off. 
IP Address: Select IP Address from the IP Configuration menu to manually 
configure the IP Address of the DHD Controller,...

Page 64

Operation
50 Vistage™ Series Flat-Panel Display Installation/Operation Manual
PREL
IMINARY
 E-Mail Notification: Select E-Mail Notification from the Network menu to specify 
when and to whom the DHD Controller sends error and service notification messages 
via e-mail.
The notification messages are in the following format:
To:  [E-Mail Address; see below]
From:  [email protected]
Subject:  [Type of notification] from Runco DHD-LS
Body:  
This is an automated message sent from the Runco DHD-LS:...

Page 65

Operation
Vistage™ Series Flat-Panel Display Installation/Operation Manual 51 
PREL
IMINARY
Periodic Service Notification: You can have the DHD Controller send periodic 
reminders via e-mail to perform regular maintenance tasks. To do this:
1. Select Periodic Service Notification from the E-Mail Notification menu. 
2. Highlight Enable and press ENTER. 
3. Highlight On and press ENTER. 
4. Press MENU.
5. Highlight Timer and press ENTER. 
6. Press   or   to set the notification interval in months. The...

Page 66

Operation
52 Vistage™ Series Flat-Panel Display Installation/Operation Manual
PREL
IMINARY
Color Space: Select Color Space from the Service menu to choose the color space of 
the source signal for HDMI, RGB, and component connections.
 The default setting, Auto, functions as follows:
HDMI: If the Auxiliary Video Information (AVI) infoframe contains color space and/or 
range data, the DHD Controller uses that information. Otherwise, for RGB sources, 
the DHD Controller uses the RGB-Video color space. For...

Page 67

Operation
Vistage™ Series Flat-Panel Display Installation/Operation Manual 53 
PREL
IMINARY
sampling Error) Correction: Some DVD players use MPEG 
decoders that do not correctly “upsample” the 4:2:0 format chroma information on the 
DVD to the 4:2:2 or 4:4:4 format required by the video encoder of the display device.
This so-called “chroma bug” sometimes causes streaky or spiky horizontal lines 
running through the chroma channel. It is most noticeable in static, interlaced scenes 
and on diagonal edges...

Page 68

Operation
54 Vistage™ Series Flat-Panel Display Installation/Operation Manual
PREL
IMINARY
Sync Threshold: Select Sync Threshold to adjust the threshold at which negative pulses 
on the component video green/luma channel are interpreted to be sync pulses.
Sync Threshold adjustment is occasionally necessary when a DVD player or HDTV source 
signal drops “below black” (for example, during scenes with explosions or when subtitles 
are present) and causes the display to temporarily lose sync. If the sync...

Page 69

Operation
Vistage™ Series Flat-Panel Display Installation/Operation Manual 55 
PREL
IMINARY
Front Panel Brightness: Select Front Panel Brightness from the Service menu to adjust 
the brightness of the front-panel LED status indicator.
 Logo LED: Select Logo LED from the Front Panel Brightness menu to adjust the 
brightness of the blue LED segment. The range is from 0 (off) to 31. 
Standby LED: Select Standby LED from the Front Panel Brightness menu to change 
the behavior of the yellow LED segment. When...

Page 70

Operation
56 Vistage™ Series Flat-Panel Display Installation/Operation Manual
PREL
IMINARY
Notes: 