Page 41
Operation Vistage™ Series Flat-Panel Display Installation/Operation Manual 27 PREL IMINARY 4.2 Using the On-Screen MenusTo display the Main Menu, press the MENU button on the remote control or DHD Controller front panel (Figure 2-4). To select a menu item, use the and buttons on the remote control or DHD Controller front panel to highlight it. Then, to confirm your selection, press ENTER on the remote control or DHD Controller front panel. The V-50HD/V-63HD OSD menus are arranged...
Page 42
Operation 28 Vistage™ Series Flat-Panel Display Installation/Operation Manual PREL IMINARY Figure 4-1. V-50HD/V-63HD OSD Menu Structure (continued) Service Test VideoColor Bars 1 Color Bars 2 Focus Grey Bars Input Names Rename/Restore Display Device - ConfigurePicture OrientationAuto, Floor Front, Ceiling Front, Floor Rear or Ceiling Rear DiagnosticsWhite, Red, Green, Blue, Yellow, Cyan, Magenta NetworkIP ConfigurationDHCP (On / Off), IP Address, Subnet Mask, Default Gateway, Communication Test Auto...
Page 43
Operation Vistage™ Series Flat-Panel Display Installation/Operation Manual 29 PREL IMINARY Main Menu The Main Menu is the starting point for accessing all DHD Controller functions. (You must enter a passcode to access the Calibration and Service menus.) Input Source From the Main Menu, select Input Source to choose a video signal source. The active source is indicated by an arrow (Î) to its left; in this example, Composite is the active source. Aspect Ratio To change the aspect ratio (size and...
Page 44
Operation 30 Vistage™ Series Flat-Panel Display Installation/Operation Manual PREL IMINARY Table 4-1. Aspect Ratio Settings Aspect RatioRemote Control KeyDescription 16:9 16:9 Select 16:9 to view 16:9 DVDs and HDTV programs in their native aspect ratio. 4:3 images are stretched horizontally to fit a 16:9 screen. 4:3 4:3 4:3 scales the input signal to fit in the center of the 16:9 screen. 4:3 is the aspect ratio used by older computer monitors, standard television programming and most VHS...
Page 45
Operation Vistage™ Series Flat-Panel Display Installation/Operation Manual 31 PREL IMINARY Cinema CINEMA Select Cinema to view 2.35:1 source material on a 16:9 screen. The upper and lower portions of the screen are masked, but the geometry of the active image area is not changed. Virtual Cinema V-CINE A 2.35:1 image is stretched anamorphically in both directions to fill a 16:9 display area. The 2.35:1 image is cropped on all sides. Native NATIVE Select Native to display the source signal in...
Page 46
Operation 32 Vistage™ Series Flat-Panel Display Installation/Operation Manual PREL IMINARY ScreenThe Screen Menu allows you to recall multiple sets of stored values for certain controls (Output Shift and Image Alignment, to name two) that are saved for each aspect ratio. Such settings are also saved “per screen.” To recall the Output Shift and Image Alignment settings associated with “Screen 1” or “Screen 2,” make that selection here. PictureUse the controls in the Picture Menu to calibrate each DHD...
Page 47
Operation Vistage™ Series Flat-Panel Display Installation/Operation Manual 33 PREL IMINARY PLUGE patterns vary but generally consist of some combination of black, white and gray areas against a black background. The example above includes two vertical bars and four shaded boxes. Select Brightness from the Picture menu and press ENTER. Adjust the brightness so that: The darkest black bars disappear into the background. The dark gray areas are barely visible. The lighter gray areas are clearly...
Page 48
Operation 34 Vistage™ Series Flat-Panel Display Installation/Operation Manual PREL IMINARY Color Saturation: On your external test pattern source, select a color bar pattern like the one shown in Figure 4-4. Figure 4-4. Typical Color Bar Pattern for Adjusting Color Saturation and Tint 1. Press the MENU button on the remote control or DHD Controller front panel. 2. Select Service from the Main Menu and press ENTER. 3. Enter the Service menu passcode. 4. Select Display Device from the Service menu and...
Page 49
Operation Vistage™ Series Flat-Panel Display Installation/Operation Manual 35 PREL IMINARY 11.Adjust the color saturation level until the outermost (gray and blue) color bars appear to be a single shade of blue: Tint: Tint or “hue” is essentially the ratio of red to green in the color portion of the image. When tint is decreased, the image appears redder; when it is increased the image appears greener. To adjust the tint, enable “blue only” display mode in the Diagnostics menu, as you would for...
Page 50
Operation 36 Vistage™ Series Flat-Panel Display Installation/Operation Manual PREL IMINARY Sharpness: “Sharpness” is the amount of high-frequency detail in the image. To adjust sharpness, select Sharpness from the Picture menu and press ENTER. On your external test pattern source, select a pattern like the one shown in Figure 4-5. Adjust as needed, looking for white edges around the transitions from black to gray and differently-sized lines in the “sweep” patterns at the top and bottom. Lower the...