Runco Rs 900 Projector User Manual
Have a look at the manual Runco Rs 900 Projector User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 123 Runco manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Maintenance and Troubleshooting Runco RS-900 Owner’s Operating Manual 67 PREL IMINARY TEMP LED lights solid red. RS-900 internal temperature is too high or one or more fans have failed. Power off the RS-900 and allow it to cool down. Ensure that the intake and exhaust vents are not blocked. Turn the projector back on. If the problem persists, please contact your Runco dealer for assistance. Table 5-1. Troubleshooting Chart (continued) Symptom Possible Cause(s)Solution
Maintenance and Troubleshooting 68 Runco RS-900 Owner’s Operating Manual PREL IMINARY Notes:
Runco RS-900 Owner’s Operating Manual 69 PREL IMINARY 6.1 RS-232 Connection and Port Configuration To interface the RS-900 with a home theater automation/control system or a PC running terminal emulation software: 1. Connect it to your control system or PC as shown in Figure 3-14. 2. Start a terminal session on your PC using a terminal-emulation program, such as HyperTerminal. 3. Configure the RS-232 controller or PC serial port as follows: no parity, 8 data bits, 1 stop bit and no flow control. Set the baud rate to 19200. 4. Type a command from among those listed in Table 6-1. For example, to select the Component 1 input, type X133X. 6.2 Serial Command Syntax Serial commands to the RS-900 take the following form: Commands are in ASCII format. Commands must be in UPPERCASE; for example, X001X, not x001x. When you enter a valid command, the RS-900 executes it and echoes the command back to the PC or control system. For example, when you send the command X001X, the RS-900 responds with X0_001X. When you enter an invalid command, the RS-900 simply ignores it. 6. Serial Communications The RS-900 will not accept serial commands for 20 seconds after it is turned on or off. Table 6-1. Serial Commands CodeFunction X001XPower On X002XPower Off X003XMenu X004XEnter X005XExit X006XUp (arrow key) X007XDown (arrow key) X008XLeft (arrow key) X009XRight (arrow key) X011XShow active source and aspect ratio information Note
Serial Communications 70 Runco RS-900 Owner’s Operating Manual PREL IMINARY X021XKeypad 1 X022XKeypad 2 X023XKeypad 3 X024XKeypad 4 X025XKeypad 5 X026XKeypad 6 X027XKeypad 7 X028XKeypad 8 X029XKeypad 9 X030XKeypad 0 X041XRestore image settings from Custom 1 X042XRestore image settings from Custom 2 X043XRestore image settings from ISF Day X044XRestore image settings from ISF Night X051XSet Gamma to 2.2 X047XRestore all Picture Adjust Menu options to their factory-default values X048XRestore all Setup Menu options to their factory-default values X049XRestore all ISF Menu options to their factory-default values X056XIncrease PIP sub-window size X057XDecrease PIP sub-window size X058XSet PIP active window X059XSet PIP on X060XSet PIP off X061X16:9 aspect ratio X062X4:3 aspect ratio X063XLetterbox aspect ratio X064XVirtualWide aspect ratio X065XCinema aspect ratio X066XVirtual Cinema aspect ratio X082XImage orientation = floor front X083XImage orientation = ceiling front Table 6-1. Serial Commands (continued) Code Function
Serial Communications Runco RS-900 Owner’s Operating Manual 71 PREL IMINARY X084XImage orientation = floor rear X085XImage orientation = ceiling rear X091XLamp Power = 170W X092XLamp Power = 200W X100XBlack Threshold = 0 IRE X101XBlack Threshold = 7.5 IRE X112XColor Temperature = 5400K X113XColor Temperature = 6500K X114XColor Temperature = 9300K X115XColor Temperature = Custom 1 X116XColor Temperature = Custom 2 X121XOSD Language = English X122XOSD Language = French X123XOSD Language = Spanish X124XOSD Language = German X125XOSD Language = Italian X131XSwitch to Composite input X132XSwitch to S-Video input X133XSwitch to Component 1 input X134XSwitch to Component 2 input X135XSwitch to HDMI 1 input X136XSwitch to HDMI 2 input X137XSwitch to RGBHV input X151XReset Lamp Timer X156XBackground Color = Blue X157XBackground Color = Gray X158XBackground Color = Black X180XBlue Image ON X181XBlue Image OFF Table 6-1. Serial Commands (continued) Code Function
Serial Communications 72 Runco RS-900 Owner’s Operating Manual PREL IMINARY Notes:
Runco RS-900 Owner’s Operating Manual 73 PREL IMINARY 7.1 RS-900 Specifications Table 7-1 lists the RS-900 specifications. 7. Specifications Table 7-1. RS-900 Specifications Projector Type:Digital Light Processing (DLP), Single-Chip SuperOnyx DMD Native Resolution:1920 x 1080 (16:9) Aspect Ratios:4:3, Letterbox, 16:9, VirtualWide, Cinema, Virtual Cinema Video Standards:NTSC, PAL, ATSC Video Compatibility:480i, 480p, 576i, 576p, 720p, 1080i, 1080p Scan Frequency:Horizontal: 15 - 80 kHz Vertical: 50 - 100 Hz Picture Size (16:9 Screen):Recommended Width: 72 in. (1.83 m) to 96 in. (2.44 m) Throw Distance (Factor x Screen Width):Refer to Table 3-3 Vertical Offset (when projector is inverted):Up = 40% of screen height above lens center (80% of one half of the screen height) Down = 60% of screen height below lens center (120% of one half of the screen height)
Specifications 74 Runco RS-900 Owner’s Operating Manual PRELI MINARY Brightness and Contrast: Cinema Standards Measurement System (CSMS) Specifications - Brightness*: 13.9 to 19.8 foot-Lamberts (fL) - Contrast Ratio*: 200:1 to 220:1 *Variable depending on RVR setting These measurements are taken from the projector in a controlled, home theater environment. All measurements are made to ANSI/NAPM IT7.228-1997 specifications using the Photo Research PR-650 SpectraColorimeter and Minolta LS-100 Luminance Meter, Video Essentials test DVD and a 1.3 gain, 72-inch wide screen. The projector is calibrated to a color temperature of 6,500K and has a minimum of 150 hours of usage. The foot-Lambert (fL) is the unit of measurement used in commercial movie theaters to express image brightness at the screen surface. The Society of Motion Picture and Television Engineers (SMPTE) specifies 16 fL as the target image brightness for film-based projectors using an open gate (without film in the projector). More importantly, today SMPTE specifies 12 fL as the target image brightness in Digital Cinema theaters. The foot-Lambert measurement is dependent on screen size, screen gain and projector light output. Home Theater Calibration Specifications - Light Output: 438 to 543 ANSI Lumens - Contrast Ratio*: 200:1 to 220:1 These specifications are obtained by calibrating the projector as described above for CSMS measurements. Industry-Standard Specifications - Light Output: 1200 ANSI Lumens - Contrast Ratio: 3000:1 These are typical projector brightness and contrast specifications found in most companies’ sales literature. Runco includes these measurements in its literature to allow for direct comparison with other manufacturers’ projectors. These measurements are typically taken at 9,000K to 13,000K to get expected performance data when the projector is used in professional, commercial and industrial displays. Lamp:200 Watts Estimated Lamp Life: 2000 hours Video Inputs: (1) Composite Video, (1) S-Video, (1) RGB/Component Video (5 x BNC), (1) RCA Component Video (3 x RCA), (2) HDMI Control Options:- Discrete IR remote - Serial commands via RS-232 RS-232 Communication Parameters: 115200 bps, no parity, 8 data bits, 1 stop bit, no flow control +12V Output:Max. 0.25 Amps, active when Cinema or Virtual Cinema Aspect Ratio is selected (CineWide versions only) or when projector is turned on; Tip = +12V; Sleeve = Ground Power Requirements:100 to 240 VAC (auto-sensing), 50/60 Hz, 340 Watts (1160.4 BTUs/hour) Table 7-1. RS-900 Specifications (continued)
Specifications Runco RS-900 Owner’s Operating Manual 75 PREL IMINARY Operating Environment:41°F to 95°F (5°C to 35°C), 20% to 80% humidity (non-condensing) Dimensions:RS-900: See Figure 7-1 RS-900/CineWide: See Figure 7-2 RS-900/CineWide with AutoScope: See Figure 7-3 Weight (without lens):34 lbs. (15.42 kg) Regulatory Approvals:Complies with FCC Class B, CE, C-Tick, GOST, TUV-GS, cTUV-US Limited Warranty: Projector: Two (2) years parts and labor from the date of delivery to the end user. Lamp: 1000 hours or six (6) months, whichever comes first. Specifications are subject to change without notice. Table 7-1. RS-900 Specifications (continued)
Specifications 76 Runco RS-900 Owner’s Operating Manual PRELI MINARY 7.2 RS-900 Dimensions Figure 7-1 shows the RS-900 dimensions (all dimensions are in inches). Figure 7-1. RS-900 Dimensions 4.47.3 8.1 8.8 9.8 19.7 18.2 17.7 8.9 11.29.3 13.0 17.3 2.2 .8