    							Maintenance and Troubleshooting
    Runco RS-900 Owner’s Operating Manual 67 
    PREL
    IMINARY
    TEMP LED lights solid red. RS-900 internal 
    temperature is too high or 
    one or more fans have 
    failed. Power off the RS-900 and 
    allow it to cool down. 
    Ensure that the intake and 
    exhaust vents are not 
    blocked. Turn the 
    projector back on. If the 
    problem persists, please 
    contact your Runco dealer 
    for assistance. 
    Table 5-1. Troubleshooting Chart (continued)
    Symptom Possible Cause(s)Solution 
    						
    							Maintenance and Troubleshooting
    68 Runco RS-900 Owner’s Operating Manual
    PREL
    IMINARY
    Notes: 
    						
    							Runco RS-900 Owner’s Operating Manual 69 
    PREL
    IMINARY
    6.1 
    RS-232 Connection 
    and Port Configuration
    To interface the RS-900 with a home theater automation/control system or a PC running 
    terminal emulation software:
    1. Connect it to your control system or PC as shown in Figure 3-14.
    2. Start a terminal session on your PC using a terminal-emulation program, such as 
    HyperTerminal. 
    3. Configure the RS-232 controller or PC serial port as follows: no parity, 8 data bits, 1 
    stop bit and no flow control. Set the baud rate to 19200. 
    4. Type a command from among those listed in Table 6-1. For example, to select the 
    Component 1 input, type X133X. 
    6.2 
    Serial Command 
    Syntax
    Serial commands to the RS-900 take the following form:
     Commands are in ASCII format.
     Commands must be in UPPERCASE; for example, X001X, not x001x.
     When you enter a valid command, the RS-900 executes it and echoes the command 
    back to the PC or control system. For example, when you send the command X001X, 
    the RS-900 responds with X0_001X. 
     When you enter an invalid command, the RS-900 simply ignores it.
    6. Serial Communications
    The RS-900 will not accept serial commands for 20 seconds after it 
    is turned on or off. 
    Table 6-1. Serial Commands 
    CodeFunction
    X001XPower On 
    X002XPower Off
    X003XMenu
    X004XEnter
    X005XExit
    X006XUp (arrow key)
    X007XDown (arrow key)
    X008XLeft (arrow key)
    X009XRight (arrow key)
    X011XShow active source and aspect ratio information
    Note 
    						
    							Serial Communications
    70 Runco RS-900 Owner’s Operating Manual
    PREL
    IMINARY
    X021XKeypad 1
    X022XKeypad 2
    X023XKeypad 3
    X024XKeypad 4
    X025XKeypad 5
    X026XKeypad 6
    X027XKeypad 7
    X028XKeypad 8
    X029XKeypad 9
    X030XKeypad 0
    X041XRestore image settings from Custom 1
    X042XRestore image settings from Custom 2
    X043XRestore image settings from ISF Day
    X044XRestore image settings from ISF Night
    X051XSet Gamma to 2.2
    X047XRestore all Picture Adjust Menu options to their factory-default values
    X048XRestore all Setup Menu options to their factory-default values
    X049XRestore all ISF Menu options to their factory-default values
    X056XIncrease PIP sub-window size
    X057XDecrease PIP sub-window size
    X058XSet PIP active window
    X059XSet PIP on 
    X060XSet PIP off
    X061X16:9 aspect ratio
    X062X4:3 aspect ratio
    X063XLetterbox aspect ratio
    X064XVirtualWide aspect ratio
    X065XCinema aspect ratio
    X066XVirtual Cinema aspect ratio
    X082XImage orientation = floor front
    X083XImage orientation = ceiling front
    Table 6-1. Serial Commands (continued)
    Code Function 
    						
    							Serial Communications
    Runco RS-900 Owner’s Operating Manual 71 
    PREL
    IMINARY
    X084XImage orientation = floor rear
    X085XImage orientation = ceiling rear
    X091XLamp Power = 170W
    X092XLamp Power = 200W
    X100XBlack Threshold = 0 IRE
    X101XBlack Threshold = 7.5 IRE
    X112XColor Temperature = 5400K
    X113XColor Temperature = 6500K
    X114XColor Temperature = 9300K
    X115XColor Temperature = Custom 1
    X116XColor Temperature = Custom 2
    X121XOSD Language = English
    X122XOSD Language = French
    X123XOSD Language = Spanish
    X124XOSD Language = German
    X125XOSD Language = Italian
    X131XSwitch to Composite input
    X132XSwitch to S-Video input
    X133XSwitch to Component 1 input
    X134XSwitch to Component 2 input
    X135XSwitch to HDMI 1 input 
    X136XSwitch to HDMI 2 input 
    X137XSwitch to RGBHV input 
    X151XReset Lamp Timer
    X156XBackground Color = Blue
    X157XBackground Color = Gray
    X158XBackground Color = Black
    X180XBlue Image ON
    X181XBlue Image OFF
    Table 6-1. Serial Commands (continued)
    Code Function 
    						
    							Serial Communications
    72 Runco RS-900 Owner’s Operating Manual
    PREL
    IMINARY
    Notes: 
    						
    							Runco RS-900 Owner’s Operating Manual 73 
    PREL
    IMINARY
    7.1 
    RS-900 Specifications
    Table 7-1 lists the RS-900 specifications.  
    7. Specifications
    Table 7-1. RS-900 Specifications 
    Projector Type:Digital Light Processing (DLP), Single-Chip SuperOnyx DMD
    Native Resolution:1920 x 1080 (16:9)
    Aspect Ratios:4:3, Letterbox, 16:9, VirtualWide, Cinema, Virtual Cinema
    Video Standards:NTSC, PAL, ATSC
    Video Compatibility:480i, 480p, 576i, 576p, 720p, 1080i, 1080p
    Scan Frequency:Horizontal: 15 - 80 kHz 
    Vertical: 50 - 100 Hz
    Picture Size (16:9 Screen):Recommended Width: 72 in. (1.83 m) to 96 in. (2.44 m)
    Throw Distance 
    (Factor x Screen Width):Refer to Table 3-3
    Vertical Offset (when 
    projector is inverted):Up = 40% of screen height above lens center (80% of one half 
    of the screen height)
    Down = 60% of screen height below lens center (120% of one 
    half of the screen height) 
    						
    							Specifications
    74 Runco RS-900 Owner’s Operating Manual
    PRELI
    MINARY
    Brightness and Contrast: Cinema Standards Measurement System (CSMS) 
    Specifications
    - Brightness*: 13.9 to 19.8 foot-Lamberts (fL)
    - Contrast Ratio*: 200:1 to 220:1
    *Variable depending on RVR setting
    These measurements are taken from the projector in a 
    controlled, home theater environment. All measurements are 
    made to ANSI/NAPM IT7.228-1997 specifications using the 
    Photo Research PR-650 SpectraColorimeter and Minolta 
    LS-100 Luminance Meter, Video Essentials test DVD and a 
    1.3 gain, 72-inch wide screen. The projector is calibrated to a 
    color temperature of 6,500K and has a minimum of 150 hours 
    of usage.
    The foot-Lambert (fL) is the unit of measurement used in 
    commercial movie theaters to express image brightness at the 
    screen surface. The Society of Motion Picture and Television 
    Engineers (SMPTE) specifies 16 fL as the target image 
    brightness for film-based projectors using an open gate 
    (without film in the projector). More importantly, today SMPTE 
    specifies 12 fL as the target image brightness in Digital 
    Cinema theaters. The foot-Lambert measurement is 
    dependent on screen size, screen gain and projector light 
    output.
    Home Theater Calibration Specifications
    - Light Output: 438 to 543 ANSI Lumens
    - Contrast Ratio*: 200:1 to 220:1
    These specifications are obtained by calibrating the projector 
    as described above for CSMS measurements. 
    Industry-Standard Specifications
    - Light Output: 1200 ANSI Lumens
    - Contrast Ratio: 3000:1
    These are typical projector brightness and contrast 
    specifications found in most companies’ sales literature. 
    Runco includes these measurements in its literature to allow 
    for direct comparison with other manufacturers’ projectors. 
    These measurements are typically taken at 9,000K to 13,000K 
    to get expected performance data when the projector is used 
    in professional, commercial and industrial displays.
    Lamp:200 Watts
    Estimated Lamp Life: 2000 hours
    Video Inputs: (1) Composite Video, (1) S-Video, (1) RGB/Component Video 
    (5
     x BNC), (1) RCA Component Video (3 x RCA), (2) HDMI
    Control Options:- Discrete IR remote
    - Serial commands via RS-232
    RS-232 Communication 
    Parameters: 115200 bps, no parity, 8 data bits, 1 stop bit, no flow control 
    +12V Output:Max. 0.25 Amps, active when Cinema or Virtual Cinema 
    Aspect Ratio is selected (CineWide versions only) or when 
    projector is turned on; Tip = +12V; Sleeve = Ground
    Power Requirements:100 to 240 VAC (auto-sensing), 50/60 Hz, 340 Watts 
    (1160.4 BTUs/hour)
    Table 7-1. RS-900 Specifications (continued) 
    						
    							Specifications
    Runco RS-900 Owner’s Operating Manual 75 
    PREL
    IMINARY
    Operating Environment:41°F to 95°F (5°C to 35°C), 20% to 80% humidity 
    (non-condensing) 
    Dimensions:RS-900: See Figure 7-1
    RS-900/CineWide: See Figure 7-2
    RS-900/CineWide with AutoScope: See Figure 7-3
    Weight (without lens):34 lbs. (15.42 kg)
    Regulatory Approvals:Complies with FCC Class B, CE, C-Tick, GOST, TUV-GS, 
    cTUV-US
    Limited Warranty: Projector: Two (2) years parts and labor from the date of 
    delivery to the end user.
    Lamp: 1000 hours or six (6) months, whichever comes first. 
    Specifications are subject to change without notice. 
    Table 7-1. RS-900 Specifications (continued) 
    						
    							Specifications
    76 Runco RS-900 Owner’s Operating Manual
    PRELI
    MINARY
    7.2 
    RS-900 Dimensions
    Figure 7-1 shows the RS-900 dimensions (all dimensions are in inches). 
    Figure 7-1. RS-900 Dimensions
    4.47.3 8.1 8.8 9.8
    19.7
    18.2 17.7
    8.9
    11.29.3
    13.0 17.3
    2.2
    .8 
    						