Page 13
- 13 - TR-936 TR-966 CHAPTER 4 ALIGNMENT 4.0 REQUIRED TEST EQUIPMENT c DC Power Supply (13.8VDC, 10A) d RF Wattmeter (25~60 MHz, 25W) e Multimeter (Digital) f Automatic Modulation Meter g Audio Signal Generator h Frequency Counter (100 MHz) i RF Signal Generator (100 MHz) j Automatic Distortion Meter k Oscilloscope (50 MHz) l Sinad Meter 4.1 ALIGNMENT PROCEDURES This transceiver has been aligned at the factory and does not require any adjustments at installation. The...
Page 14
- 14 - 4.1.2 TRANSMITTER ALIGNMENT ITEM U.U.T. SETTING ADJUST POINT MEASUREMENT BIAS Current (TR-966) Set radio to CH 19 USB TX mode. Modulation Off. Connect current meter to TP7(+) and TP9 (-). Connect current meter to TP7 (+) and TP8 (-). VR12 VR10 100 mA 50 mA SSB APC (TR-966) Set radio to CH 19 USB RX mode. Connect Multimeter to TP7. VR17 12.5 VDC SSB TX Power (TR-966) Connect “short PCB” to TP7, TP8 and TP9. Connect RF Power Meter to antenna jack. Set radio to CH 19...
Page 15
- 15 - ITEM U.U.T. SETTING ADJUST POINT MEASUREMENT AM Sensitivity Set radio to CH 19 AM RX mode. Set RF GAIN Fully Clockwise. Set SQ Fully Counter Clockwise. Set VOL Control at 2 o’clock. Set NB/ANL/OFF switch to OFF position. Set TONE Fully Clockwise. Set CLARIFIER Control to 12 o’clock. (TR-966) Connect RF SG to antenna jack Frequency 27.185 MHz, 1uV. Mod 30%. L2,L3,L5,L6, L7,L8,L9,L1 0 Audio Output > 2V S/N > 10 dB. Set radio to CH 40 AM RX mode. RF SG setting 27.405...
Page 18
- 18 - TR-936 TR-966 CHAPTER 5 MAINTENANCE 5.0 PRECAUTIONS The inherent quality of the solid-state components used in this transceiver will provide many years of continuous use. Taking the following precautions will prevent damage to the transceiver. (i) Never key the transmitter unless an antenna or suitable dummy load is connected to the antenna receptacle. (ii) Ensure that the input voltage does not exceed 16 VDC or fall below 11 VDC. (iii) During alignment, do not transmit...
Page 19
- 19 - TR-936 TR-966 DIAGRAMS & PARTS LIST 6.0 GENERAL Information on most electrical and mechanical parts is included in the parts list. The reference designators are in alphanumeric order. 6.1 ORDERING REPLACEMENT PARTS Parts orders should be referred to the parts department at: • Ranger Communications, Inc. 401 W. 35 TH ST, # B NATIONAL CITY, CA 91950-7909 Tel: (619) 426-6440 Fax: (619) 426-3788
Page 20
- 20 - PART LIST: TR-936 / TR-966 ROTARY SW P.C.B ITEM REFERENCE NUMBER RANGER PART NUMBER DESCRIPTION REMARK 1 EPT690021A ROTARY SW PCB 2 R201,R206-R213 RCY011021Z 1K Ω 0.1W TR-936 3 R201 RCY014714Z 470 Ω 0.1W TR-966 4 R202-R205,R214 RCY012224Z 2.2K Ω 0.1W TR-936 5 R214 RCY013324Z 3.3K Ω 0.1W TR-966 6 R215 RCY015624Z 5.6K Ω 0.1W 7 R202-R205,R206-R213 RCY011024Z 1K Ω 0.1W TR-966 8 D223 RCY010004Z 0 Ω 0.1W 9 D201-D205,D217- D219,D222,D225 EDSS00355Y...