    							111
    1240–1300 MHz ................................................................ 0.7µV
    AM:
    25–54 MHz ........................................................................... 1µV
    108–136.9875 MHz .............................................................. 1µV
    137–174 MHz .................................................................... 1.5µV
    216–225 MHz .................................................................... 1.5µV
    406–512 MHz ....................................................................... 2µV
    806–960 MHz ...................................................................... 2µV`
    1240–1300 MHz ................................................................... 3µV
    Selectivity:
    25 – 27.995 MHz in AM mode
    -6 dB ............................................................................... +/-5 kHz
    -50 dB ............................................................................. +/-6 kHz
    All frequencies at AM and FM mode except 25 – 27.995 MHz at AM
    -6 dB ............................................................................. +/-10 kHz
    -50 dB ........................................................................... +/-18 kHz
    IF Rejection
    380.8 MHz at 154.1 MHz ................................................... 60 dB
    21.4 MHz at 154.1 MHz .................................................... 100 dB
    Spurious Rejection
    (at 154.1 MHz FM) .............................................................. 40 dB
    Scanning Speed and Delay
    Scanning Rate ............................ Up to 60 Channels per Second
    Search Rate ...................................... Up to 75 Steps per Second
    Conventional Channel Delay Time .............................. 2 seconds
    Priority Sampling.......................................................... 2 seconds
    Trunking Talkgroup Delay Time ....................... User configurable
    Intermediate Frequencies (IF):
    1st ............................................................................... 380.8 MHz
    2nd ................................................................................ 21.4 MHz
    3rd................................................................................... 455 kHz
    Squelch Sensitivity:
    Threshold (FM and AM) ..................................................... 0.5µV
    Tight (FM) ........................................................................... 25 dB
    Tight (AM) ........................................................................... 20 dB
    Antenna Impedance....................................................... 50 Ohms 
    						
    							112
    Audio Output Power (10% THD) .....................................170 mW
    Built-in Speaker ........ 1
    3/8Inches (36 mm) 8-ohm Dynamic Type
    Power Requirements:
    Batteries .............................................. 4 AA Alkaline Batteries or
    ...................................................... 4 AA Rechargeable Batteries
    External Power .................................................... 9 V/300 mA DC
    Current Drain (Squelched) ................................................ 90 mA
    Battery Charge Current ................................................... 150 mA
    Physical
    Dimensions (HWD) ..........................6
    3/16×27/16×13/4inches
    ......................................................................(157×62×41 mm)
    Weight (without antenna and batteries)................. 8.8 oz. (250 g)
    Operating Temperature ......................14 to 140° F (-10 to 60° C)
    Specifications are typical: individual units might vary.
    Specifications are subject to change and improvement without
    notice. 
    						
    							113
    COMMAND QUICK REFERENCE GUIDE
    Scan Mode
    KeystrokesFunction
    SCAN Activates Scan Mode, resumes scan when
    stopped on a channel or talkgroup.
    MANIf scanning or monitoring a trunked call, stops
    scan operation, activates Manual Mode.
    If monitoring conventional call, stops scan
    operation, activates Manual Mode, holds on
    active channel.
    PGM If scanning or monitoring a trunked call, stops
    scan operation, activates Program Mode.
    If monitoring conventional call, stops scan
    operation, activates Program Mode, holds on
    active channel.
    WXActivates Weather Mode
    TRUNK If monitoring a trunking talkgroup, stores the
    ID into the next available ID list memory
    location.
    TRUNK (hold)If monitoring a trunking talkgroup, activates ID
    Hold Mode, scanner holds on the active
    talkgroup.
    PRI Toggles priority.
    TUNEEnters Tune Mode.
    ATT Toggles attenuation for active channel, or, if
    global attenuation is set, toggles global
    attenuationonoroff.
    TEXTIf monitoring a trunking talkgroup, toggles
    talkgroup alphanumeric text tag or trunking ID
    display.
    L/OUT If monitoring a trunking talkgroup, locks out
    the active talkgroup so it will not be monitored.
    If monitoring a conventional channel, locks out
    the active channel so it will not be monitored.
    MODEIf monitoring a conventional channel, cycles
    through the valid modes, clears any stored CT
    or DC code.
    SRCH Activates Search Mode.
    NUMBER
    KEYS 0-9Toggle scan banks on or off.
    DECIMAL
    POINTWhen monitoring a conventional channel,
    toggles delay for that channel on or off. 
    						
    							114
    Manual Mode
    ENTERWhen monitoring a conventional channel that
    is programmed for CT or DC Search Mode,
    stores a detected CT or DC code with the
    channel memory.
    SorTChanges scan direction, up or down.
    FUNC + MANToggles digital AGC
    FUNC +
    TRUNKWhen monitoring a talkgroup call, toggles
    display of control channel text tag or Trunked
    ID sub-bank status.
    FUNC + PRIIf monitoring a conventional channel, stores
    the frequency into the priority channel.
    FUNC +
    TUNEIf monitoring a conventional channel, stores
    the frequency into the tune memory.
    FUNC + ATTToggles attenuator mode, normal or global.
    FUNC + 5 Toggles open or closed mode for current bank.
    FUNC + 0-4When Trunked ID sub-bank display is active,
    and while monitoring a talkgroup call, toggles
    ID sub banks 0-4 on or off.
    KeystrokesFunction
    SCAN Activates Scan Mode.
    MANIncrements to the next channel memory.
    PGM Activates Program Mode.
    WXActivates Weather Mode .
    PRI Toggles priority.
    TUNEEnters Tune Mode.
    AT TToggles attenuation for selected channel,
    or, if global attenuation is set, toggles
    global attenuation on or off.
    L/OUTToggles lockout on the selected channel.
    MODECycles through valid modes for the
    selected channel, clears any stored CT or
    DC settings.
    SRCHActivates Search Mode.
    2, 3, MAN Jumps to channel 23 in the current bank.
    1, 2, 3, MANJumps to bank 1, channel 23.
    DECIMAL
    POINTToggles delay on selected channel on or
    off.
    KeystrokesFunction 
    						
    							115
    Program Mode
    ENTER
    When monitoring a conventional channel
    that is programmed for CT or DC Search
    Mode, stores a detected CT or DC code
    with the channel memory.
    SorTSsteps to the next channel,Tsteps to the
    previous channel. Hold down to scroll.
    FUNC + MANToggles digital AGC.
    FUNC + TRUNK Enters trunked ID list for current bank.
    FUNC + PRIStores the frequency of the selected
    channel into the priority channel.
    FUNC + TUNEStores the frequency of the selected
    channel frequency into the tune memory.
    FUNC + ATTToggles attenuator mode, normal or global.
    FUNC + 5Toggles open or closed mode for current
    bank.
    FUNC + 9Adjust display contrast, useSorTthen
    ENTER.
    FUNC + L/OUT Jumps to the next locked out channel.
    FUNC +SorTSjumps forward to the next bank,Tjumps
    to the previous bank. Hold down to scroll.
    KeystrokesFunction
    SCAN Activates Scan Mode.
    MANActivates Manual Mode.
    PGM Increments to the next channel memory.
    WXActivates Weather Mode.
    PRI Selects priority channel for programming.
    TEXTEdits text tag for selected channel.
    TRUNK Enters ID List Edit for the selected bank.
    TUNEEnters Tune Mode.
    AT TToggles attenuation for selected channel,
    or, if global attenuation is set, toggles
    global attenuation on or off.
    L/OUTToggles lockout on the selected channel.
    MODECycles through valid modes for the
    selected channel, clears any stored CT or
    DC settings.
    KeystrokesFunction 
    						
    							116
    SRCHSets search range for programmable
    search range (PSR).
    2, 3, PGM Jumps to channel 23 in the current bank.
    1, 2, 3, PGMJumps to bank 1, channel 23.
    DECIMAL POINTToggles delay on selected channel on or
    off.
    
    ENTEREnters a frequency into channel memory.
    SorTSsteps to the next channel,Tsteps to
    the previous channel, hold down to scroll.
    FUNC + MANToggles digital AGC.
    FUNC + MODEIf selected channel mode is set to CT or
    DC, edits CT or DC code.
    FUNC + PRIStores the frequency of the selected
    channel into the priority channel.
    FUNC + TUNEStores the frequency of the selected
    channel frequency into the tune memory.
    FUNC + ATTToggles attenuator mode, normal or global.
    FUNC CLRClears all programming data in selected
    channel.
    FUNC + 5Toggles open or closed mode for current
    bank.
    FUNC + 7 Edits bank text tag.
    FUNC + L/OUTJumps to the next locked out channel.
    FUNC + TEXTEdits welcome screen line 4 (stored with V-
    Scanner as folder name).
    FUNC + PGMEnters V-Scanner function menu.
    FUNC +SorTSjumps forward to the next bank,T
    jumps to the previous bank. Hold down to
    scroll.
    KeystrokesFunction 
    						
    							117
    Search Mode
    KeystrokesFunction
    SCAN Activates Scan Mode.
    MANActivates Manual Mode.
    PGM Activates Program Mode.
    WXActivates Weather Mode.
    PRI Toggles priority.
    TUNEEnters Tune Mode.
    AT TToggles attenuation for active search range,
    or, if global attenuation is set, toggles global
    attenuation on or off.
    L/OUTLocks out undesired search frequencies or
    search channels.
    PAUSE Pauses and resumes search operations.
    MODECycles through AM/FM/CT/DC modes for
    selected search range.
    SRCH Steps through the available search ranges.
    DECIMAL
    POINTToggles delay on or off in selected search
    range or search channel.
    SorTChanges search direction.
    FUNC + MANToggles digital AGC.
    FUNC + PRIWhen searching SR1 to SR6, stores active
    search frequency in priority memory.
    FUNC + TUNE
    When searching SR3, SR4, SR5 and SR6,
    stores active search frequency in tune
    memory.
    FUNC + ATT Toggles attenuator mode, normal or global.
    FUNC + L/OUT
    In SR0, SR1, SR2, steps to next locked out
    search channel, must be in “M” state. In
    SR3, SR4, SR5 and SR6, enters Search
    Lockout Review. Use arrow keys to review
    locked frequencies, useCLRto clear locked
    frequencies, useFUNC+6to clear all
    locked frequencies.
    FUNC + MODESets mode to default for active search
    range.
    FUNC + SRCHToggles Manual Channel Select or Search
    Channels for SR0, SR1 and SR2. 
    						
    							118
    Weather Mode
    FUNC + PGMWhen searching SR3, SR4, SR5 and SR6,
    stores active search frequency in desired
    bank and channel (e.g., “123 + ENTER”
    stores the active frequency in Bank 1,
    Channel 23).
    FUNC +
    ENTER
    When searching SR3, SR4, SR5 and SR6,
    stores active search frequency in next
    available channel in desired bank (e.g., “1 +
    ENTER” stores active frequency in next
    empty channel in Bank 1).
    FUNC+7 TogglesSeekonoroff.
    FUNC + 0Toggles Zeromatic on or off.
    KeystrokesFunction
    SCAN Activates Scan Mode.
    MANActivates Manual Mode.
    PGM Activates Program Mode.
    WXSteps to next weather channel.
    WX, and then
    hold WXWeather alert alarm demonstration. Press
    any key to exit.
    TUNEEnters Tune Mode.
    AT TToggles attenuation for selected weather
    frequency, or, if global attenuation is set,
    toggles global attenuation on or off.
    SRCHEnters Search Mode.
    NUMBER KEYS
    0-9Quick FIPS code review for FIPS
    memories 0-9. PressL/OUTto toggle
    lockout status.
    FUNC + PRI
    Stores active weather frequency in priority
    memory. PressPRIin Scan, Search,
    Manual, Program modes to activate WX
    Priority.
    FUNC + ATT Toggles attenuator mode, normal or global.
    FUNC + PGM
    FIPS code entry - UseSorTto scroll, key
    in FIPS code +ENTERto store. Press
    L/OUTto toggle lockout of FIPS code,
    pressTEXTand enter text label for FIPS
    memory. PressWXto exit.
    FUNC + WXActivates FIPS/SAME weather alert mode.
    PressFUNC+WXto exit.
    KeystrokesFunction 
    						
    							119
    Tune Mode
    ID List Edit
    KeystrokesFunction
    SCAN Activates Scan Mode.
    MANActivates Manual Mode.
    PGM Activates Program Mode.
    WXActivates Weather Mode.
    PRI Toggles priority.
    AT T
    Toggles attenuation for active search
    range, or, if global attenuation is set,
    toggles global attenuation on or off.
    PAUSE Pauses and resumes tune operations.
    MODECycles through AM/FM/CT/DC modes.
    SRCH Activates Search Mode
    DECIMAL POINTToggle tune delay on or off.
    SorTChanges tune direction, resumes tune
    operation after stopping on an active
    frequency.
    FUNC + MANToggles digital AGC.
    FUNC + PRIStores active tune frequency in priority
    memory.
    FUNC + ATTToggles attenuator mode, normal or global.
    FUNC + MODESets mode to default for active search
    range.
    FUNC + PGM
    Stores active tune frequency in desired
    bank and channel (e.g., “123 + ENTER”
    stores the active frequency in Bank 1,
    Channel 23).
    FUNC + ENTERStores active tune frequency in next
    available channel in desired bank
    (e.g., “1 + ENTER” stores active frequency
    in next empty channel in Bank 1).
    KeystrokesFunction
    SCAN Activates Scan Mode.
    MANActivates Manual Mode.
    PGM Activates Program Mode.
    WXActivates Weather Mode.
    TEXT Edits text tag for selected ID. 
    						
    							120
    TRUNKSteps to first ID in next ID sub bank.
    TUNE Enters Tune Mode.
    L/OUTToggles lockout on the selected ID.
    MODECycles trunking mode through MO, ED
    and “not trunked”.
    SRCHActivates Search Mode.
     ENTER Stores ID into selected location.
    SorTSsteps to the next ID,Tsteps to the
    previous ID, hold down to scroll.
    FUNC + MAN Toggles digital AGC.
    FUNC +
    DECIMAL POINTSelects ID delay duration for selected
    bank.
    FUNC CLRClears all programming data in selected
    ID.
    FUNC + 1Toggles active sub bank on or off.
    FUNC + 2Base/offset/step table entry for Motorola,
    toggles AFS or Decimal display for
    EDACS.
    FUNC + 3Motorola 3600 control channel mode
    select.
    FUNC + 4Motorola/P25 9600 control channel mode
    select.
    FUNC + 6Clears all ID entries in current ID list.
    FUNC + 8 Sets Motorola Type I fleetmap.
    FUNC + L/OUTJumps to the next locked out ID.
    FUNC + TRUNK Launches ID hold mode on selected ID.
    FUNC + PGMEnters V-Scanner function menu.
    FUNC +SorTSjumps forward to the next ID bank,T
    jumps to the previous ID bank. Hold down
    to scroll.
    KeystrokesFunction 
    						
    All RadioShack manuals Comments (0)

    Related Manuals for RadioShack Pro 96 Truking Scanner Owners Manual