Page 1
Please read these operating instructions thoroughly before using your air conditioner and keep for future reference. For assistance, please call: 1-800-211-PANA(7262) or Register your product at : http://www.panasonic.com/register INSTALLATION AND OPERATING INSTRUCTIONS Room Air Conditioner Model: HQ-2244UH CW382820391G
Page 2
2 Safety Precautions About the Controls on the Air Conditioner Features and Installation Before you call for service... FOR YOUR RECORDS Staple your receipt to this page in case you need it later. Write down the model and serial numbers here: Model # Serial # You can find them on a label on the side of each unit. Dealers Name Date Purchased Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventive care on your part can save you a great deal...
Page 3
WARNING 3 Safety PrecautionsSafety Precautions To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instruction will cause harm or damage. The seriousness is classified by the following indications. WARNING: This symbol indicates the possibility of death or serious injury. CAUTION:This symbol indicates the possibility of injury or damage to property only. Meanings of symbols used in this manual are as...
Page 4
4 Safety Precautions When the air filter is to be removed, do not touch the metal parts of the unit. • It may cause an injury. Do not clean the air conditioner with water. • Water may enter the unit and degrade the insulation. It may cause an electric shock. Ventilate well when used together with a stove, etc. • An oxygen shortage may occur. When the unit is to be cleaned, switch off, and turn off the breaker. • Since the fan rotates at high speed during operation, it may cause an injury. Do not put a...
Page 5
5 About the Controls on the Air Conditioner 62 1 8 347 OPERATION TEMP TIMERAIR SWING MODE ECONOMYFAN SPEED1 6 24 5 3 7 About the Controls on the Air Conditioner Controls OPERATION BUTTON• To turn the air conditioner ON, push the button. To turn the air conditioner OFF, push the button again. • This button takes priority over any other buttons. • When you first turn it on, the air conditioner is on the High cool mode and the temp. at 72°F(22°C) OPERATION MODE SELECTION BUTTON Every time you push this...
Page 6
Additional controls and important information. Ventilation The ventilation lever must be in the CLOSE position in order to maintain the best cooling conditions. When fresh air is necessary in the room, set the ventilation lever to the OPEN position. The damper is opened and room air is drawn out. Air Direction The vertical air direction is adjusted by rotating the horizontal louver forward or backward manually.The horizontal air direction is adjusted by rotating the vertical louver right or left by...
Page 7
7 About the Controls on the Air Conditioner Air Filter Cleaning The air filter behind the front grille should be checked and cleaned at least once every 2 weeks or more often if necessary. The grille is designed to clean the filter both upward and downward. TO REMOVE: 1. Open the inlet grille upward by pulling out the bottom of the inlet grille or downward by pulling out the top of the inlet grille. 2. Using the tab, pull up slightly on the filter to release it and pull it down or up. 3. Clean the...
Page 8
8 Features and Installation Learning parts name prior to installation will help you understand the installation procedure. Features Features CABINET FRONT GRILLE AIR FILTER AIR INTAKE (INLET GRILLE) AIR DISCHARGE HORIZONTAL AIR DEFLECTOR (VERTICAL LOUVER) VERTICAL AIR DEFLECTOR (HORIZONTAL LOUVER) EVAPORATOR CONTROL BOARD POWER CORD BASE PAN CONDENSER COMPRESSOR BRACE REMOTE CONTROLLER
Page 9
About 1/2 Over 20HEAT RADIATIONFENCE AWNING INSIDE OUTSIDE FOAM COOLED AIR 30-60Level 1/4 Bubble 26 to 41 18 min Offset Sill Exterior Interior wall Stool 9 Installation Features and Installation How to Install the Unit 1. To avoid vibration and noise, make sure the unit is installed securely and firmly. 2. Install the unit where the sunlight does not shine directly on the unit. If the unit receives direct sunlight, build an awning to shade the cabinet. 3. There should be no obstacle, like a fence, within...
Page 10
Foam-PE (Adhesive-Backed)Foam-PE (Adhesive-Backed) Type C (5) Type D (2)Type A (14)Carriage Bolt (2) Lock Nut (4) Type B (7) Foam strip (Plain-Back) Right frame curtain Drain pipe Window locking bracket Left frame curtain Sill bracket(2)Support bracket(2) 10 Features and Installation Installation Kits Contents Top retainer bar is in product package.