Home > Quasar > Air Conditioner > Quasar Room Air Conditioner Hq2081th Installation And Operating Instructions

Quasar Room Air Conditioner Hq2081th Installation And Operating Instructions

    Download as PDF Print this page Share this page

    Have a look at the manual Quasar Room Air Conditioner Hq2081th Installation And Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 140 Quasar manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							INSTALLATION AND OPERATING INSTRUCTIONS
    Room Air Conditioner
    Model : HQ-2081TH
    Please read these operating instructions thoroughly
    before using your air conditioner and keep for future reference.
    For assistance, please call : 1-800-211-PANA(7262) or 
    Register your product at : http://www.panasonic.com/register 
    						
    							2
    Safety Precautions
    About the Controls on the Air Conditioner
    Features and Installation
    Before you call for service...
    FOR YOUR RECORDS
    Staple your receipt to this page in case you need it later.
    Write down the model and serial numbers here:
    Model #
    Serial #
    You can find them on a label on the side of each unit.
    Dealers Name
    Date Purchased
    Inside you will find many helpful hints on how to use and
    maintain your air conditioner properly. Just a little preventive
    care on your part can save you a great deal of time and
    money over the life of your air conditioner.
    Youll find many answers to common problems in the chart
    of troubleshooting tips. If you review our chart of
    Troubleshooting Tipsfirst, you may not need to call for
    service at all.
    READ THIS MANUAL
    CAUTION
    • Contact the authorized Service technician for repair or
    maintenance of this unit.
    • The air conditioner is not intended for use by young
    children or infirm persons without supervision.
    • Young children should be supervised to ensure that they
    do not play with the air conditioner.
    Safety Precautions
    Safety Precautions .............3
    About the Controls on
    the Air Conditioner
    Controls ..............................5
    Ventilation ..........................6
    Air Direction........................6
    How to Secure Drain Pipe....6
    Care and Maintenance 
    Air Filter Cleaning...............7
    Features
    Features .............................8
    Installation
    How to Install the Unit ........9
    Window Requirements .......9
    Installation Kit Contents ...10
    Suggested Tool
    Requirements ...................10
    Cabinet Installation...........11
    Electrical Data ..................13
    Electrical Safety ...............14
    Before you call for
    service...
    Normal Operation .............15
    Abnormal Operation .........15 
    						
    							WARNING
    3
    Safety PrecautionsSafety Precautions 
    To prevent injury to the user or other people and property damage, the following instructions must be
    followed.
    Incorrect operation due to ignoring of instruction will cause harm or damage. The seriousness is classified
    by the following indications.
    WARNING: This symbol indicates the possibility of death or serious injury.
    CAUTION:This symbol indicates the possibility of injury or damage to
    property only.
    Meanings of symbols used in this manual are as shown below.
    Be sure not to do this.
    Be sure to follow the instructions.
    Plug in the power plug
    properly.
    • Otherwise, it will cause electric
    shock or fire due to heat
    generation.
    Do not operate or stop the
    unit by inserting or pulling
    out the power plug.
    • It will cause electric shock or fire
    due to heat generation.
    Do not damage or use an
    unspecified power cord.
    • It will cause electric shock or fire.
    • 
    If the power cord is damaged, it must
    be replaced by the manufacturer or
    an authorized service center or a
    similarly qualified person in order to
    avoid a hazard.
    Do not modify power cord
    length or share the outlet
    with other appliances.
    • It will cause electric shock or fire
    due to heat generation.
    Do not operate with wet
    hands or in a damp
    environment.
    • It will cause electric shock.
    Do not direct air flow at room
    occupants.
    • This could lead to health
    problems. 
    						
    							4
    Safety Precautions
    When the air filter is to be
    removed, do not touch the
    metal parts of the unit.
    • It may cause an injury.
    Do not clean the air
    conditioner with water.
    • Water may enter the unit and
    degrade the insulation. It may
    cause an electric shock.
    Ventilate well when used
    together with a stove, etc.
    • An oxygen shortage may occur.
    When the unit is to be
    cleaned, switch off, and turn
    off the breaker.
    • Since the fan rotates at high
    speed during operation, it may
    cause an injury.
    Do not put a pet or house
    plant where it will be exposed
    to direct air flow.
    • This could injure the pets or
    plants.
    Do not use for special
    purposes.
    • Do not use this air conditioner to
    preserve precision devices, food,
    pets, plants, and art objects. 
    It may cause deterioration of
    quality, etc.
    Do not operate switches 
    with wet hands
    .
    • It may cause an electric shock.
    Do not apply an insecticide 
    or flammable spray.
    • It may cause a fire or deformation
    of the cabinet.
    Do not put a heater, etc.
    where it is exposed to direct
    air flow.
    •It may cause imperfect
    combustion. 
    						
    							5
    About the Controls on the Air Conditioner
    About the Controls on the Air Conditioner
    The controls will look like one of the following.
    Controls
    When the air conditioner has performed its cooling operation and is turned off or set to the fan
    position, wait at least 3 minutes before resetting to the cooling operation again.
    Off- Turns air conditioner off.
    Med Fan- Med speed fan operation without cooling.
    Low Fan- Low speed fan operation without cooling.
    High Cool- Cooling with high speed fan operation.
    Med Cool- Cooling with med speed fan operation.
    Low Cool- Cooling with low speed fan operation.
    This automatically controls the temperature of the indoor air.
    Turn the knob so that arrow points to the higher number for greater cooling.
    Point the arrow to the lower number for more moderate cooling.
    (i.e. the higher the number, the greater the cooling)
    • FOR NORMAL COOLING
    1. Turn the operation switch to the High Cool or the Low Cool setting.
    2. Set the Thermostat control to the desired temperature mark 5(the mid-point is a good starting position). 
    If the room temperature is not satisfactory after a reasonable time, adjust the control to a cooler or warmer
    setting, as appropriate.
    • FOR MAXIMUM COOLING
    1. Turn the Operation Knob to the High Cool setting.
    2. Set the Thermostat control to the highest (9) temperature mark.
    • FOR QUIETER OPERATION
    1. Turn the Operation Knob to the Low Cool setting.
    2. Set the Thermostat control as needed.
    CAUTION Model : HQ2081TH 
    						
    							VENT CLOSE
    OPEN
    Par tA
    Par tB
    Drain pipe
    Drain cap
    6
    About the Controls on the Air Conditioner
    Additional controls and important information.
    Ventilation
    The ventilation lever must be in the CLOSE position in order to maintain the best cooling conditions.
    When fresh air is necessary in the room, set the ventilation lever to the OPEN position. 
    The damper is opened and room air is drawn out.
    NOTE:Before using the ventilation feature, and prior to installing the front grille, pull down part 
    until
    level with part 
    .
    Air Direction
    The direction of air can be controlled wherever you want to cool by adjusting the horizontal
    louver and the vertical louver.
    The vertical air direction is adjusted by rotating the
    horizontal louver forward or backward manually.
    The horizontal air direction is adjusted by rotating the
    vertical louver right or left manually. •VERTICAL AIR-DIRECTION CONTROL
    •
    HORIZONTAL AIR-DIRECTION CONTROL
    How to Secure the Drain Pipe
    In humid weather, excess water may cause the BASE
    PAN to overflow. To drain the water, remove the DRAIN
    CAP and secure the DRAIN PIPE to the rear hole of the
    BASE PAN. Press the drain pipe into the hole by pushing
    down and away from the fins to avoid injury. 
    						
    							7
    About the Controls on the Air Conditioner
    Air Filter Cleaning
    The air filter behind the front grille should be checked and cleaned at least once every 2
    weeks or more often if necessary.
    TO REMOVE: 
    1. Open the inlet grille upward by pulling out the bottom of the inlet grille or downward by
    pulling out the top of the inlet grille.
    2. Using the tab, pull up slightly on the filter to release it and pull it down or up.
    3. Clean the filter with warm, soapy water under 40°C (104°F).
    4. Rinse and gently shake the water from the filter and let it dry before replacing it.
    CAUTION:DO NOT operate the air conditioner without a filter because dirt and lint will
    clog it and reduce performance.
    Care and Maintenance
    TURN THE AIR CONDITIONER OFF AND REMOVE THE PLUG FROM THE POWER OUTLET. 
    						
    							8
    Features and Installation
    Learning parts name prior to installation will help you understand the installation procedure.
    Features
    Features
    CABINET
    FRONT GRILLE
    AIR FILTER
    AIR INTAKE
    (INLET GRILLE) AIR DISCHARGE HORIZONTAL AIR DEFLECTOR
    (VERTICAL LOUVER) VERTICAL AIR DEFLECTOR
    (HORIZONTAL LOUVER)
    EVAPORATOR
    CONTROL BOARD
    POWER CORD BASE PAN CONDENSER COMPRESSOR BRACE 
    						
    							About 12.7mm (1/2)
    76.2cm (30)~
    152.4cm (60)
    Awning
    Cooled airFence
    Over 50.8cm (20)
    Heat 
    radiation
    55.8cm (22) to
    91.44cm (36)
    Offset12.7mm (1/2) to
    31.8mm (11/4)
    Sill
    Exterior
    Interior wall
    47cm (181/2) min.(Without frame curtain)
    Stool38cm (15) min
    (With frame curtain)
    9
    INSTALLATION
    Features and Installation
    1. To prevent vibration and noise, make sure
    the unit is installed securely and firmly
    2. Install the unit where the sunlight does not
    shine directly on the unit.
    3. The outside of the cabinet must extend
    outward for at least 28cm (11) and there
    should be no obstacles, such as a fence or
    wall, within 50.8cm (20) from the back of
    the cabinet because it will prevent heat
    radiation of the condenser.
    Restriction of outside air will greatly reduce
    the cooling efficiency of the air conditioner.
    CAUTION: All side louvers of the cabinet must remain exposed to the outside of the
    structure.
    4. Install the unit a little slanted so the back is slightly lower than the front 
    (about 12.7cm (
    1/2)).
    This will force condensed water to flow to the outside.
    5. Install the unit with the bottom about 76.2cm (30)~152.4cm (60) above the floor level.
    Window Requirements
    NOTE: All supporting parts should be secured to firm wood, masonry, or metal.
    This unit is designed for installation in
    standard double hung windows with actual
    opening widths from 55.88cm (22) to
    91.44cm (36).
    The top and bottom window sash must open
    sufficiently to allow a clear vertical opening of
    38cm (15) from the bottom of the upper sash
    to the window stool.
    How to Install the Unit 
    						
    							9
    10
    9
    5
    5
    5
    11
    11
    (Type A)(Type A)
    13
    1234
    813
    14
    10
    765
    9
    12
    11
    Shipping 
    Screws
    PREPARATION OF CHASSIS
    1. Remove the screws which fasten the cabinetat both sides and at the back.
    2. Slide the unit from the cabinet by gripping the base pan handle and pulling while bracing the
    cabinet.
    3. Cut the window sash seal to the proper length. 
    Peel off the backing and attach the FOAM-PE
    to the underside of the window sash.
    4. Remove the backing from the top upper guide FOAM-PE 
    and attach it to the bottom of
    the upper guide 
    5. Attach the upper guide onto the top of the cabinet with 3 type A screws.
    6. Insert the frame guides 
    into the bottom of
    the cabinet.
    7. Insert the Frame Curtain 
    into the upper
    guide 
    and frame guides .
    8. Fasten the curtains to the unit with 4 Type  A screws.
    10
    Features and Installation
    Suggested Tool Requirements
    Installation Kit Contents
    SCREWDRIVER(+, -), RULER, KNIFE, HAMMER, PENCIL, LEVEL
    NO. NAME OF PARTS QTY
    1 FRAME CURTAIN 2
    2 SILL SUPPORT 2
    3 BOLT 2
    4 NUT 2
    5SCREW(TYPE A) (10mm(2/5))16
    6SCREW(TYPE B)3
    7SCREW(TYPE C)5
    8 FOAM-STRIP 1
    9 UPPER GUIDE 1
    10FOAM-PE (466mm x 10mm x 2mm)1
    11 FRAME GUIDE 2
    12WINDOW LOCKING BRACKET1
    13
     FOAM-PE (920mm x 3 0mm x  2mm)          1
    14 DRAIN PIPE 1
    D5.1mm(0.2)
    16mm(0.63)
    D4.1mm(0.17)
    16mm(0.63) 
    						
    All Quasar manuals Comments (0)