Philips Fm2 Service Manual
Here you can view all the pages of manual Philips Fm2 Service Manual. The Philips manuals for Medical Equipment are available online for free. You can easily download all the documents as PDF.
Page 81
Breakdown of Spare Parts Kits by Component Chapter 7 - Spare Parts 69 M3921-60406 - Knob (Navigation Wheel) Kit M2922-44301 - Keypad Kit M2922-64004 - Display Kit Table 14 M2922-60406 Knob (Navigation Wheel) Kit Component DescriptionQuantity Knob 1 Ring retaining 3/8” shaft 1 Table 15 M2922-44301 Keypad Kit Component DescriptionQuantity Small Parts Kit1 1. For contents of the hardware mounting kit, refer to Table 10 on page 66. 1 Keypad - switch, membrane 1 Table 16 M2922-64004 Display Kit Component...
Page 82
Breakdown of Spare Parts Kits by Component 70Chapter 7 - Spare Parts M2922-66505 - Side Connector PCB Kit M2922-66510 - Interface PCB Kit M2922-66511 - Rear Connector PCB Kit Table 17 M2922-66505 Side Connector PCB Kit Component DescriptionQuantity Small Parts Kit1 1. For contents of the Small Parts Kit, refer to Table 10 on page 66. 1 Side PCB, with twin ultrasound, and one Toco sockets 1 Table 18 M2922-66510 Interface PCB Kit Component DescriptionQuantity Small Parts Kit1 1. For contents of the Small...
Page 83
Assembly Drawings Chapter 7 - Spare Parts 71 Assembly Drawings Figure 7 Assembly Drawing (Sheet 1) - Top Level Assembly
Page 84
Assembly Drawings 72Chapter 7 - Spare Parts Figure 8 Assembly Drawing (Sheet 2) - Front Case Assembly
Page 85
Assembly Drawings Chapter 7 - Spare Parts 73 Figure 9 Assembly Drawing (Sheet 3) - Rear Case Assembly
Page 86
Assembly Drawings 74Chapter 7 - Spare Parts Figure 10 Assembly Drawing (Sheet 4) - Interface PCB/Rear Connector PCB
Page 87
Assembly Drawings Chapter 7 - Spare Parts 75 Figure 11 Assembly Drawing (Sheet 5) - Side Connector PCB/ Panel/Label
Page 89
Chapter 8 - Test and Inspection Matrix77 8 Test and Inspection Matrix Warnings Warning EXPLOSION HAZARD! Do not use the FM-2 in a flammable atmosphere where concentrations of flammable anesthetics or other materials may occur. Warning SHOCK HAZARD! The power-receptacle must be a three-wire grounded outlet. A hospital grade outlet is required. Never adapt the three-prong plug from the power supply or accessory to fit a two-slot outlet. If the outlet has only two slots, make sure that it is replaced...
Page 90
Cautions 78Chapter 8 - Test and Inspection Matrix Cautions Caution Use care when transporting or moving the monitor to assure that the attached patient cables are stored so that they will not be damaged in the move. Caution Keep the operating environment free of dust, vibrations, corrosive, or flammable materials, and extremes of temperature and humidity. The unit should be kept clean and free of transducer gel and other substances. Caution Do not operate the unit if it is damp or wet because of...