Page 21
19 Note A red or blue bright dot must be more than 50 percent brighter than neighboring dots while a green bright dot is 30 percent brighter than neighboring dots. Black Dot Defects Black dot defects appear as pixels or sub pixels that are always dark or 'off'. That is, a dark dot is a sub-pixel that stands out on the screen when the monitor displays a light pattern. These are the types of black dot defects: Proximity of Pixel Defects Because pixel and sub pixels defects of the same...
Page 22
20 4. Technical Specifications 273E3 Picture/Display LCD panel type TFT-LCD Backlight CCFL 273E3 Panel size 27" ( 68.6 cm) Aspect ratio 16:9 Pixel Pitch 0.31 x 0.31 mm Brightness 395 cd/m² Smar tContrast 500,000:1 Contrast ratio (typ.) 1000:1 Response time (typical) 5 ms Optimum Resolution 1920x1080 @ 60Hz Viewing angle 170° (H) / 160° (V)@C/R>10 Picture Enhancement Smar tImage Lite Display colors 16.7 M Ver tical...
Page 23
21 Power On mode 43.5W (typical) Energy Consumption (EnergyStar 5.0 test method) AC Input Voltage at 100VAC +/-5VAC, 50Hz +/- 3Hz AC Input Voltage at 115VAC +/-5VAC, 60Hz +/- 3Hz AC Input Voltage at 230VAC +/-5VAC, 50Hz +/ -3Hz Normal Operation (typcial) 25.15W 25.10W 25.10W Sleep 0.5W 0.5W 0.5W Off 0.5W 0.5W 0.5W Heat Dissipation* AC Input Voltage at 100VAC +/-5VAC, 50Hz +/ -3Hz AC Input Voltage at 115VAC +/-5VAC, 60Hz +/...
Page 24
22 Dimension Product with stand (WxHxD) 642x440x227mm Product without stand (WxHxD) 642x391x64mm Box dimension (WxHxD) 700x138x525mm Weight Product with stand 8.2kg Product without stand 6.5kg Product with packaging 8.82kg Operating Condition Temperature range (operation) 0°C to 40 °C Temperature range (Non-operation) -20°C to 60°C Relative humidity 20% to 80% Altitude operation: + 12,000 ft ( 3,658 m) Non-operation: + 40,000 ft (...
Page 25
23 4.1 Resolution & Preset Modes4.2 Automatic PowerSaving If you have VESA DPM compliance display card or software installed in your PC, the monitor can automatically reduce its power consumption when not in use. If an input from a keyboard, mouse or other input device is detected, the monitor will 'wake up' automatically. The following table shows the power consumption and signaling of this automatic power saving feature: Maximum Resolution For...
Page 26
24 5. Regulatory Information Lead-free Product Lead free display promotes environmentally sound recover y and disposal of waste from electrical and electronic equipment. Toxic substances like Lead has been eliminated and compliance with European community’s stringent RoHs directive mandating restrictions on hazardous substances in electrical and electronic equipment have been adhered to in order to make Philips monitors safe to use throughout its life cycle. TCO Displays 5.0 Information...
Page 27
25 • 2005/32/EC (EuP Directive, EC No. 1275/2008 mplementing Directive for Standby and Off mode power consumption) and is produced by a manufacturing organization on ISO9000 level. • The product also comply with the following standards • ISO9241-307:2008 (Ergonomic requirement, Analysis and compliance test methods for electronic visual displays) • GS EK1-2000:2009 (GS mark requirement) • prEN50279:1998 (Low Frequency Electric and Magnetic fields for Visual...
Page 28
26 Federal Communications Commission (FCC) Notice (U.S. Only) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Par t 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful...
Page 29
27 Commission Federale de la Communication (FCC Declaration) Cet équipement a été testé et déclaré conforme auxlimites des appareils numériques de class B,aux termes de l'ar ticle 15 Des règles de la FCC . Ces limites sont conçues de façon à fourir une protection raisonnable contre les interférences nuisibles dans le cadre d'une installation résidentielle. CET appareil produit, utilise et peut émettre des hyperfréquences qui, si l'appareil n'est pas...
Page 30
28 Polish Center for Testing and Certification Notice The equipment should draw power from a socket with an attached protection circuit (a three- prong socket). All equipment that works together (computer, monitor, printer, and so on) should have the same power supply source. The phasing conductor of the room's electrical installation should have a reser ve shor t-circuit protection device in the form of a fuse with a nominal value no larger than 16 amperes (A). To completely switch off the...