21 z Loosen two fixing screws on both ends of the base cover by using the bit for tamperproof screw (accessory), and remove the base cover (accessory). Install the mount bracket (accessory) on the wall/ceiling. (For use of the hole A) 51 mm {2"} ø27 mm {1-1/16"} 135 mm {5-5/16"} 135 mm {5-5/16"} For use of the hole 85 mm {3-11/32"} 85 mm {3-11/32"} For use of the hole Cable access hole Mount bracket (accessory) Center of mount bracket Female thread for conduit Mount bracket (accessory) Base cover (accessory)
22 Note: • Only the same type of holes, (A) or (B), shall be used for mounting. x Pass the cables through the hole for cable running from the wall or ceiling. c Fix the camera attachment on the mount bracket using the screws supplied with the bracket. Recommended tightening torque: 0.78 N·m {0.58 lbf·ft} Note: • For wall mounting: The camera attachment shall be mounted with "gTOP" facing upward. (Except the case of connecting the conduit upward ( ☞ page 20)) • For ceiling mounting: The camera attachment shall be mounted with aligning the front side (model number indication face) of the camera with the position of the arrow in "hFRONT". • Ensure that any of the arrows on the mount bracket is aligned with the "gTOP" arrow on the camera attachment. Mount bracket (accessory) Camera attachment FRONTTOP
23 Important: • Before inserting the SDHC/SD memory card, turn off the power of the camera first. • When inserting an SDHC/SD memory card, make sure the direction. • Before removing the SDHC/SD memory card, select "Not use" for "SD memory card" on the [SD memory card] tab of the setup menu first. Turn off the power after "Not use" selection, and then unload the SDHC/SD memory card. When the SDHC/SD memory card is inserted or removed with the power on, data in the SDHC/SD memory card may be damaged. ( ☞ Network Operating Instructions (PDF) z Detach the enclosure. (☞ Page 34) x Insert an SDHC/SD memory card fully into the SDHC/SD memory card slot until a click is heard. c Attach the enclosure to the camera. ( ☞ Page 40) v When removing the SDHC/SD memory card from the SDHC/SD memory card slot, detach the enclosure ( ☞ page 34), and push the card until a click is heard. After the SDHC/SD mem- ory card is removed, attach the enclosure to the camera again. ( ☞ Page 40) Insert/remove an SDHC/SD memory card Label side
24 Heater Unit WV-SW3H (option) • Installing this heater unit enables the camera to operate in a low-tempe\ rature environment below –30 °C {22 °F}. A small fan inside the unit will minimize\ condensation on the surface of the enclosure caused by changes in ambient temperature unless temperatures change too rap- idly. The fan will stop when there is no possibility of condensation. • The heater unit is automatically turned on or off according to the temperature inside the camera that is monitored. Important: • Turning the heater on and off may disturb the camera images. • The power supply of the camera shall be turned off when mounting or dismounting the heater. When servicing, pay attention to high temperature on the surface of the heater unit. Disconnect the harness and wait until the heater unit cools. • When this product is installed and operated in low temperatures below –10 °C {14 °F}, normal images may not be obtained immediately after startup. In such a case, wa\ it until the camera is warmed up (approx. 2 hours or more) and turn on the power again. How to install the heater unit q Detach the camera’s enclosure (☞ page 34) and mount it in the specified position with the screw (accessory). w Connect the harness cable to the heater unit connector of the camera. Important: • After mounting the heater unit, arrange the harness cable as shown in the illustration in step e so as not to be tangled round the enclosure, assist wire or equipment inside the camera. How to install the heater unit
25 e Attach the enclosure to the camera. (☞ Page 40) Heater unit (option) connectorScrew (accessory of the heater unit)* * Two screws are supplied with the heater unit. (Of them, 1 for spare)
26 Caution: • FOR UL LISTED MODEL(S), ONLY CONNECT 12 V DC CLASS 2 POWER SUPPLY. Turn off a circuit breaker before making a connection. Before starting the connection, prepare the required devices and cables. Note: • When using the mount bracket (accessory), it is possible to connect th\ e cables after mounting the camera onto the mount bracket. • Refer to page 20 when connecting the conduit. Connection Network cable * PAL model only * PAL model only RJ-45 (female) Alarm input/output cable 4P alarm cable (accessory) Power cable (12 V DC) 2P power cable (accessory) 12 V DC (red) GND (black) Microphone/line input cable (white) Audio output cable (black) Power cable 12 V DC Red Positive Black Negative z Connect the microphone/line input cable and the microphone (for use of the audio reception function). Input impedance: 2 kΩ±10 % Recommended cable length: Less than 1 m {3.28'} (for microphone input) Less than 10 m {32.8'} (for line input) Recommended microphone: Plug-in power type microphone (option) Connect a mini plug (ø3.5 mm). Supply voltage: 2.5 V ±0.5 V Recommended sensitivity of microphone: −48 dB ±3 dB (0 dB=1 V/Pa,1 kHz) Important: • Connect/disconnect the external speaker cables or audio/video cables after turning off the power of the camera and the amplifier. Otherwise, loud noise may come out from the speaker.
27 x Connect an external amplifier-embedded speaker to the audio output cable (for use of the audio transmission function). Connect a stereo mini plug (ø3.5 mm) (Audio output is monaural.). • Recommended cable length: Less than 10 m {32.8 ft} c Connect the alarm input/output cable. Terminal name Ratings ALARM OUT, AUX OUT Open collector output (maximum applied voltage: 20 V DC) Open: 4 V DC - 5 V DC by internal pull-up Close Output voltage 1 V DC or less (50 mA or less) ALARM IN, DAY/NIGHT IN Non-voltage make contact input (4 V DC - 5 V DC, internally pulled up) OFF Open or 4 V DC - 5 V DC ON Make contact with GND (required drive current: 1 mA or more) Note: • Check if rating of an external device such as a sensor is applicable to the rating of this product by referring to the provided operating instructions. Specification of 4P alarm cable (accessory) GND (black) AUX OUT (gray) (Terminal 3) ALARM OUT (red) (Terminal 2) ALARM IN, DAY/NIGHT IN (green) (Terminal 1)
28 v Connect a LAN cable (category 5e or better, straight, STP*) to the network connector. * PAL model only b Connect the power cable. • When using 12 V DC power supply* 1 Connect the output cable of the AC adaptor to the 2P power cable. • When using PoE (IEEE802.3af compliant) Connect a LAN cable (category 5 or better, straight, STP* 2) between a PoE device (such as a hub) and the network connector of the camera. *1 FOR UL LISTED MODEL(S), ONLY CONNECT 12 V DC CLASS 2 POWER SUPPLY. *2 PAL model only Connect the power cord. • Use all 4 pairs (8 pins) of the LAN cable. • The maximum cable length is 100 m {328'}. • Make sure that the PoE device in use is compliant with IEEE802.3af standard. • When connecting both the 12 V DC power supply and the PoE device for pow\ er supply, PoE will be used for power supply. • When the LAN cable is disconnected once, reconnect the cable after about 2 seconds. When the cable is quickly reconnected, the power may not be supplied from the PoE device.
29 Waterproof treatment for the cable joint sections Adequate waterproof treatment is required for the cables when installing the camera with cables exposed or installing it under the eaves. The camera body is waterproof, but the cable ends are not waterproof. Be sure to use the supplied butyl rubber tape at the points where the cables are connected to apply waterproof treatment in the following procedure. Failure to observe this or use of a tape other than the provided butyl rubber tape (such as a vinyl tape) may cause water leakag\ e resulting in mal- function. LAN cable Alarm input/output cable, power cable, microphone/line input cable, audio output cableImportant: • Waterproof treatment is also to be applied to the 2P power cable (accessory), the 4\ P alarm cable (accessory) and other connection cables if they are subject to rain. Note: • How to wind the supplied waterproof butyl tape Stretch the tape by approx. twice (see the illustration) and wind it around the cable. Insufficient tape stretch causes insufficient waterproofing. • To install this product outdoors, be sure to waterproof the cables. Waterproof grade (IEC IP66 or equivalent) is applied to this product only when it is installed correctly as described in these operating instructions and appropriate waterproof treatment is applied. The mount brackets are not waterproofed. Wind the tape in a half-overlapping manner. Wind the tape in a half-overlapping manner. Stretch the tape to about twice. 2x
30 Connection example when connecting to a network using a PoE hub LAN cable (category 5 or better, straight, STP*) * PAL model onlyImportant: • The video monitor is used for checking the adjustment of the angular fie\ ld of view when install- ing the camera or when servicing. It is not provided for recording/monitoring use. • Use a switching hub or a router which is compliant with 10BASE-T/100BASE-TX. • Power supply is required for each network camera. When using a PoE device (hub), 12 V DC power supply is unnecessary. Powered speaker (option) Powered speaker (option) Microphone (option) Microphone (option) Video monitor (for adjustment use only) Video monitor (for adjustment use only) PoE device (hub) LAN cable (category 5 or better, straight, STP*) LAN cable (category 5 or better, straight, STP*) LAN cable (category 5 or better, straight, STP*) PC