51 Configures the multi-screen settings [Multi-screen setup] The cameras to be used for the multi-screen display can be registered on this page. Refer to page 9 for descriptions of how to display images on a multi-screen. The following cameras are applicable for the multi-screen display. (as of May 2007) WV-NF284 series, WV-NS202 series, WV-NP240 series, WV-NP1000 series, WV-NW470S series, WV-NP472, WV- NS320 series, WV-NW484S series, WV-NS202A series [IP address] Enter the IP address or the host name of the camera to be used for the multi-screen. 4 cameras can be regis- tered as a group and up to 4 groups (16 cameras) can be registered. When the HTTP port number for the camera had been changed, enter as follows:IP address of the camera:port number, for example 192.168.0.10: 8080. Number of characters for the IP address:1 - 128 characters Note: When using the host name, it is necessary to config- ure the DNS settings of the PC to be used for the multi-screen display. (page 68) [Camera title] Enter the title of the camera. The entered camera title will be displayed on a multi-screen. Number of characters for the camera title:0 - 20 characters Note: When selecting a 16 split-screen, some characters of the camera title to be displayed may not be dis- played.
52 Configure the alarm settings [Alarm setup] The settings relating to alarm occurrences such as settings for the alarm action at an alarm occurrence, the alarm occurrence notification, and the VMD area settings can be configured on this page. The Alarm setup page has 3 tabs; the [Alarm] tab, the [VMD area] tab and the [Notification] tab. Configure the settings relating to the alarm [Alarm] Click the [Alarm] tab on the Alarm setup page. (pages 20 and 21: How to display/operate the setup menu) Alarm setup The settings relating to the alarm can be configured in this section. Refer to pages 53, 55 and 56 for further informa- tion about the settings relating to the camera action at an alarm occurrence, the alarm image and the alarm output terminal. [Terminal alarm 1] Select OFF or Alarm input to determine whether or not to receive a terminal alarm 1. OFF:Does not receive alarms. Alarm input:Receives alarms. Default:OFF [Terminal alarm 2] Determine whether or not to receive a terminal alarm 2 by selecting OFF, Alarm input or Alarm output. OFF:Does not receive alarms. Alarm input:Receives alarms. Alarm output:Alarm output will be carried out accord- ing to the settings for Alarm output terminal setup (page 56). Default:OFF[Terminal alarm 3] Determine whether or not to receive a terminal alarm 3 by selecting OFF, Alarm input or AUX output. OFF:Does not receive. Alarm input:Receives alarms. AUX output:The AUX buttons will be displayed on the Live page. Default:OFF [VMD alarm] Select ON or OFF to determine whether or not to perform the alarm action using the VMD function. Refer to page 57 for descriptions of how to set the VMD areas. Default:OFF [Command alarm] Select ON or OFF to determine whether or not to receive the command alarm. The command alarm is the function that provides notifi- cation of a Panasonic protocol alarm from the other cameras. When ON is selected, alarm actions will be performed between multiple cameras. Default:OFF [Originating port number] Select a port number to be used to receive the com- mand alarm. Available port number:1 - 65535 Default:8181
53 Configure the settings relating to the camera action at an alarm occurrence Click the [Alarm] tab on the Alarm setup page. (pages 20 and 21: How to display/operate the setup menu) Camera motion on alarm The settings relating to the camera action at an alarm occurrence can be configured in this section. Refer to pages 52, 55 and 56 for further information about the settings relating to the alarm, the alarm image and the alarm output terminal. [Terminal alarm 1] Select an action to be taken when a terminal alarm 1 is detected from the following. OFF:Does not take any action even when a terminal alarm 1 is detected. 1-64:When the registered preset position is selected, the camera will move to the selected preset position when a terminal alarm 1 is detected. Auto track:When a terminal alarm 1 is detected, the camera will start the auto tracking. When the home position is set, the camera will start auto tracking after moving to the home position once. Default:OFF [Terminal alarm 2] Select an action to be taken when a terminal alarm 2 is detected from the following. OFF:Does not take any action even when a terminal alarm 2 is detected. 1-64:When the registered preset position is selected, the camera will move to the selected preset position when a terminal alarm 2 is detected. Auto track:When a terminal alarm 2 is detected, the camera will start the auto tracking. When the home position is set, the camera will start auto tracking after moving to the home position once. Default:OFF[Terminal alarm 3] Select an action to be taken when a terminal alarm 3 is detected from the following. OFF:Does not take any action even when a terminal alarm 3 is detected. 1-64:When the registered preset position is selected, the camera will move to the selected preset position when a terminal alarm 3 is detected. Auto track:When a terminal alarm 3 is detected, the camera will start the auto tracking. When the home position is set, the camera will start auto tracking after moving to the home position once. Default:OFF AUX is the terminal that can be switched between OPEN and CLOSE from the Live page. It is useful when controlling the connected external device. For example, when it is necessary to control lighting at the camera location, connect a lighting control device to the terminal (AUX OUT) of the camera to remotely control lighting at the camera location. [VMD alarm] Select an action to be taken when a VMD alarm is detected from the following. OFF:Does not take any action even when a VMD alarm is detected. 1-64:When the registered preset position is selected, the camera will move to the selected preset position when a VMD alarm is detected. Auto track:When a VMD alarm is detected, the cam- era will start the auto tracking. When the home position is set, the camera will start auto tracking after moving to the home position once. Default:OFF
54 [Command alarm] Select an action to be taken when a command alarm is detected from the following. OFF:Does not take any action even when a command alarm is detected. 1-64:When the registered preset position is selected, the camera will move to the selected preset position when a command alarm is detected. Auto track:When a command alarm is detected, the camera will start the auto tracking. When the home position is set, the camera will start auto tracking after moving to the home position once. Default:OFF
55 Configure the settings relating to the alarm image Click the [Alarm] tab on the Alarm setup page. (pages 20 and 21: How to display/operate the setup menu) Alarm image setup The settings relating to the alarm image to be transmitted to an FTP server can be configured in this section. The alarm image will be transmitted to an FTP server. To transmit alarm images to an FTP server, it is necessary to con- figure the settings in advance. (page 66) Refer to pages 52, 53 and 56 for further information about the settings relating to the alarm, the camera action at an alarm occurrence and the alarm output terminal. Important: •Depending on the network line speed or the network traffic, images may not be transmitted at the exact designat- ed interval or period. •When Alarm input or Manual is selected for Save trigger on the [SD memory card] tab, images will not be transmitted to the FTP server even when an alarm is detected. (page 27) [To FTP setup] When To FTP setup is clicked, the [FTP] tab of the Server setup page will be displayed. (page 66) [Alarm image FTP transmission] Select ON or OFF to determine whether or not to transmit the alarm image to the FTP server. Default:OFF [Directory] Enter the directory name where the alarm images are to be saved. For example, enter /ALARM to designate the directory ALARM under the root directory of the FTP server. Number of characters for the directory name:1 - 256 characters [File name] Enter the file name used for the alarm image to be transmitted to an FTP server. The file name will be as follows.File name:[Entered file name + Time and date (year/month/day/hour/minute/second)] + Serial number Number of characters for the file name:1 - 32 char- acters [Post alarm] • Transmission interval Select the transmission interval for the alarm image transmission to the FTP server from the following. 0.1 fps/0.2 fps/0.33 fps/0.5 fps/1 fps Default:1 fps • Number of images Select the number of images to be transmitted from the following. 1 pic/2 pics/3 pics/4 pics/5 pics/6 pics/7 pics/8 pics/ 9 pics/10 pics/20 pics/ 30 pics/50 pics/100 pics/ 200 pics/300 pics/500 pics/1000 pics/2000 pics/ 3000 pics/5000 pics Default:100 pics • Recording duration Approximate time to be taken to save the set num- ber of images with the set transmission interval will be displayed. [Image capture size] Select QVGA or VGA for the image capture size of images to be transmitted to the FTP server or of an image to be attached to the alarm mail. Default:VGA
56 Configure the settings relating to the alarm out terminal Click the [Alarm] tab on the Alarm setup page. (pages 20 and 21: How to display/operate the setup menu) Alarm output terminal setup The settings relating to the alarm out terminal can be configured in this section. The settings for the alarm output ter- minal can be configured only when Alarm output is selected for Terminal alarm 2 of Alarm setup. Refer to pages 52, 53 and 55 for further information about the settings relating to the alarm, the camera action at an alarm occur- rence and the alarm image. [Alarm output setup] Select ON or OFF to determine whether or not to output the alarm signals to the alarm output terminal when an alarm is detected. Default:OFF [External terminal output setup] Select Latch or Pulse for the alarm output terminal at an alarm occurrence. Latch:When an alarm is detected, the alarm output ter- minal will be in the state selected for Alarm output until the alarm occurrence indication button is clicked. Pulse:When an alarm is detected, the alarm output ter- minal will be in the state to the Alarm output setting for the period set for Pulse width. Default:Latch [Alarm output] Select Open or Close to determine whether to open or close the alarm output terminal when outputting the alarm signals. OPEN:The alarm output terminal will open when out- putting the alarm signals. (Normally close) CLOSE:The alarm output terminal will close when out- putting the alarm signals. (Normally open) Default:OPEN Note: When OPEN is selected, the alarm signal will be output for around 20 seconds when the power of the camera is turned on. [Pulse width] When Pulse is selected for Alarm output, select an alarm output terminal duration from the following. Available pulse width:1 - 120 sec Default:1 sec AUX name The names of AUX, OPEN and CLOSE on the Live page can be changed. [AUX (Up to 10 characters)] Enter the name for AUX on the Live page. [OPEN (Up to 5 characters)] Enter the name for OPEN of AUX on the Live page. [CLOSE (Up to 5 characters)] Enter the name for CLOSE of AUX on the Live page.
57 Set the VMD areas [VMD area] Click the [VMD area] tab on the Alarm setup page. (pages 20 and 21: How to display/operate the setup menu) The video motion detection areas can be set on this page. The VMD areas can be set for each preset position (up to 64 areas). When motion is detected in the set area, the alarm action will be performed. The camera can be configured to take an alarm action even when the camera is not at the preset position. Important: •Areas used for the time and date display of OSD position (page 25) cannot be used for the VMD areas. •It is possible to display the alarm occurrence indication button on the [VMD area] tab when motion is detected by the VMD function. Select ON for VMD alarm on the [Alarm] tab when the alarm occurrence indication button is to be displayed. •The alarm occurrence indication button will be displayed when receiving an alarm input of a terminal alarm or a command alarm. •Depending on the network environment, notification may be delayed even when Real time is selected for Alarm status update mode on the [Basic] tab of the Basic setup page (page 25). Areas used for the time and date display of OSD position
58 Configure to detect motion in areas without the preset positions Configure whether or not to detect motion when the camera is not at the preset position by setting the detection sen- sitivity. The sensitivity can be set by configuring VMD area setting except Preset position. When determining whether to detect motion even when the camera is not at the preset position, all areas except areas used for the time and date display of OSD position will be subject to the detection. The VMD area setting is unavailable. [Status] Select ON or OFF to determine whether or not to carry out the VMD function. ON:Carries out the VMD function OFF:Does not carry out the VMD function Default:OFF [Detection sensitivity] Select a sensitivity level in the detection area from the following. 1 (Super high)/2/3/4 (High)/5 (Middle)/6 (Low) Default:Middle Important: Click the [SET] button after completing the settings. The setting will not be applied unless the [SET] but- ton is clicked.
59 Step 1 Select a preset position number to which the VMD area is to be set from Preset position select of VMD area setting for Preset position. Step 2 Click the [Setup] button. →The VMD area setup window for the selected preset position number will be displayed. Step 3 Set the video motion detection area by dragging the mouse on the screen. When the [All areas] button is clicked, the whole area will become the VMD area and set as area 1 (white). →The designated area will become the VMD area and the outline will be displayed. When 2 - 4 VMD areas are set, each area will be numbered in order. The areas will be identified by the respective outline col- ors. Important: The position selected for OSD position will not be applied to the VMD area. Step 4 Select ON or OFF for Status of each VMD area. When the [SET] button is clicked after selecting OFF, the outline will become a broken line and no alarm action will be performed even when motion is detected in the area. Set the VMD areas for each preset position Important: •The VMD function will be carried out only when the camera is at the preset position. •When the settings are being configured on the setup menu, sometimes the VMD function may not work correctly.
60 Step 5 Select the detection sensitivity from the following. The selected detection sensitivity will be applied to all the VMD areas. 1 (Super high)/2/3/4 (High)/5 (Middle)/6 (Low) Default:MiddleStep 6 Click the [SET] button after completing the settings. Important: The setting will not be applied unless the [SET] but- ton is clicked. Delete the VMD area set for the designated preset position Step 1 Display the VMD area setup window of the preset posi- tion number whose VMD area is to be deleted. (page 59) Step 2 Click the [Delete] button respective to the area to be deleted. →The outline of the area will disappear. Step 3 Click the [SET] button. →The deletion will be completed. Important: The deletion will not be completed unless the [SET] button is clicked.