Home > Panasonic > Ventilation > Panasonic Ventilation Fan Fv 08vkl1 Installation Instructions

Panasonic Ventilation Fan Fv 08vkl1 Installation Instructions

    Download as PDF Print this page Share this page

    Have a look at the manual Panasonic Ventilation Fan Fv 08vkl1 Installation Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							Ventilating Fan
    SpecificationsDimensions
    Description
    12 11-12
    13-14
    14 6-84
    4-54 32
    2
    Table of Contents
    Supplied Accessories
    Unpacking
    General Safety Information
    I
    Installation( Wooden Header )
    10III( -Joist Mounting )I
    10-11Installation
    ( Between Joist Mounting )
    Installation( In Existing Construction )VI
    Installation( Joist Mounting- )I
    Installation
    Maintenance
    Practical Guide to Installation
    14Product Service
    FV-08VKL1
    8-9II( Joist Mounting- )II Installation
    IV
    V
    READ AND SAVE THESE INSTRUCTIONS.R
    Please
    readthese
    instructionscarefullybeforeattempting
    toinstall,
    operate or service the Panasonic Ventilating Fan. Failure to comply
    with instructions could result in personal injury and/or property
    damage. Please retain this booklet for future reference. 
    						
    							FV-08VKL1
    Quantity Appearance
    Part name
    Screw
    (M4X8)I21
    Grille
    Suspension
    bracketI
    Suspension
    bracketII
    1
    1
    2Screw
    (M4X12)II
    Screw
    (M4X16)III
    2
    Machine screw
    (M4X8)1
    Quantity Appearance
    Part name
    2
    1
    1
    18W
    Fluorescent
    lamp
    4W
    Night lamp
    Lighting unit
    These Panasonic ceiling mount ventilating fan models use a sirocco fan with dolphin-shaped blades driven by
    brushless direct current motor. The motor is designed to have long operating life, high dynamic response, higher
    speed ranges with saving eneray. The grille can be quickly detached from the main unit. A damper for preventing
    air counterflow is provided. The blower uses a high-capacity sirocco fan developed to reduce the noise level.
    The light unit is an energy-saving, lighting device which uses two 18W fluorescent lamps and produces almost
    the same illumination as a standard 100W incandescent lamp.
    1Suspension
    bracketIII
    1 8Thumb screwLong screw
    (M4X30) 
    						
    							FV-08VKL1
    Junction box cover
    Junction box
    Lighting unit assy
    Fluorescent lamp
    Night lamp
    Part name No. Part nameNo.
    1
    2
    3
    4
    5
    67
    8
    9
    10
    11
    Damper Fan bodyAdaptor
    Grille
    Suspension bracket
    Bracket cover
    Unit: ( )inches mm
    7
    3 1/2 (90)1 (25)
    5 1/8 130()
    7 7/8 200() 13/4 45()
    126()
    6
    13 330()
    10 1/4 261()
    3 1/2 (90)27/873()
    8
    9
    1110
    37/8 98()10 1/4 (261)
    12 1/8 (307)
    3 1/4 (81)
    (For 16 inches on center joists,only use suspension bracket , for 19.2 inches on center joists, only use
    suspension bracket , If more than 19.2 inches on center,use suspension bracket & .)I
    III II III
    13 1/4~15 1/2 ( 336~394 )
    16 1/2~18 3/4 ( 419~480 )
    21 1/4~23 1/2 ( 540~597 ) 
    						
    							Specifications are based on HVI standard.
    Unpack and carefully remove unit from carton.
    Refer to the Supplied Accessories list to verify that all parts are present.
    1. Do not install this ventilating fan where air temperature may exceed 40 C (104 F).oo
    2. Make sure that the electric service supply voltage is 120V, 60 Hz.
    3. Follow all local electrical and safety codes, as well as the National Electrical Code
    (NEC) and the Occupation Safety and Health Act (OSHA).
    4. Always disconnect the power source before working on or near the fan, motor or light
    fixture.
    5. Protect the power cord from sharp edges, oil, grease, hot surfaces, chemicals or other
    objects.
    6. Do not kink the power cord.
    7. Do not install the unit where ducts are configured as shown in Fig. A.
    8. Provide suction parts with proper ventilation.
    9. This unit is approved for use over a bathtub or shower when installed in a GFCI
    protected branch circuit.
    FV-08VKL1
    Noise
    (sone) Duct
    diameter
    (inches)
    4
    						
    							CAUTION:
    1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
    2. Not for use in cooking area. (Fig .B)
    3. This product must be properly grounded.
    Floor
    Do not install above or(Cooking area)
    inside this area
    45o45o
    equipmentCooking
    Fig. B
    WARNING:
    To reduce the risk of fire, electric shock or injury to persons, observe the following;
    A. Use this unit only in the manner intended by the manufacturer. If you have any questions, contact
    the manufacturer.
    B. Installation work and electrical wiring must be done by qualified person(s) in accordance with all
    applicable codes and standards, including fire-rated construction.
    C. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney)
    of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturers
    guideline and safety standards such as those published by the National Fire Protection Association
    (NFPA), and the American Society for Heating Refrigeration and Air Conditioning Engineers
    (ASHRAE) and the local code authorities.
    D. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
    E. Ducted fans must always be vented to the outdoors.
    F. These models are UL listed for tub and shower enclosures.
    G. Solid state controls may cause harmonic distortion which can cause motor humming noise. Do not use
    this unit with any solid-state control device.
    H. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting
    means to prevent power from being switched on accidentally. When the service disconnecting means
    cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
    I. NEVER place a switch where it can be reached from a tub or shower.
    J. Not to be installed in a ceiling thermally insulated to a value greater than R40. 
    						
    							1. Before installation, secure the fan body to adaptor by
    using thumb screw. (Fig.1)
    Remove the tape
    IMPORTANT :
    Adaptor
    Remove the tape from damper and adaptor
    before installation. As show below:
    Damper
    2-Screw (M4X8)I
    Suspension bracketIIISuspension bracketII
    6
    Fig.1
    Suspension
    bracketI
    Suspension
    bracketIII
    Suspension
    bracketISuspension
    bracketIII
    Suspension
    bracketI
    Fig.2-1
    Fig.2-2
    Fig.2-3
    Fig.2-4Fan body
    Fan body
    Fan body
    Fan body
    Suspension
    bracketI
    Suspension
    bracketIII
    Suspension
    bracketII
    Fan body
    Thumb screw
    2. Insert the supension bracket into the fan body and
    adaptor. (select the suspension bracket as show below)
    Spacing A on center Joists
    Insert Suspension bracket
    12 inches
    16 inches
    19.2 inches vertical joists
    24 inchesRefer to Fig. 2-1
    Refer to Fig. 2-2
    Refer to Fig. 2-3
    Refer to Fig. 2-4
    If spacing A on center joists is 24 inches, connect
    suspension bracket and (C4 mark to C4 mark)
    as show below :II III
    Joists
    A 
    						
    							Main PCB
    Junction box
    Fan body
    Power supply
    AC120V 60Hz
    Black
    White
    Red
    Green Black
    WhiteLive
    Neutral
    Ground
    M
    Black
    White
    Black
    WhiteCurrent Fuse
    Electronic
    BallastLive
    Neutral
    Live
    Neutral
    Wiring diagram
    Lighting unit
    Black
    Red
    Blue
    Fluorescent
    Lamp
    Night
    Lamp
    3.15A
    Fig.3-2
    Fig.4
    4. Install the suspension bracket to joists by using long
    screws (M4X30) and secure it to the fan body by
    using screw (M4X12) (Fig.4)II
    Fan body
    Joist
    4-Long screws(M4X30)
    Joist Fan body
    2-Long screws
    (M4X30)
    2-Long screws
    (M4X30)
    screw (M4X12)II
    7
    Junction box cover
    Fig. 5
    ConduitDuct
    5. Remove junction box cover and secure conduit or
    stress relief to junction box knock-out hole. (Fig.5)
    6. Refer to wiring diagram below.
    Using wire nuts, connect house power wires to
    ventilating fan wires:
    black to black; white to white; green to green;
    Replace the junction box cover.
    CAUTION:
    Mount junction box cover carefully so that lead wires
    are not pinched.
    7. Install a circular duct and secure it with duct tape or
    clamps.
    Fig.3-1
    Wire nut
    Conduit
    Junction box
    Green wires Lead wires
    3. Install the suspension bracket and the flange of fan body
    to joists by using long screws (M4X30) ( If spacing A
    between joists is 12 inches, install the flange of fan body
    according to Fig.3-2, others according to Fig.3-1 to install
    the product)
    Duct tape
    3. Instale la abrazadera de suspension y la brida del cuerpo del
    ventilador a las vigas usando los tornillos largos (M4X30)
    (Si el espacio A entre las vigas es de mas de 12 pulgadas,
    instalar el costado del cuerpo del ventilador siguiendo la
    muestra en la Fig. 3-2, para otras dimensiones instale el
    producto de acuerdo a la Fig. 3-1) 
    						
    							3. Follow step 5 to 7 of the installation (page 7) to
    complete the duct work and wiring.I
    8
    9. Insert the plug connector and plug connector
    into the receptacle and receptacle respectively,
    and secure the light unit to the fan unit with 2 screw
    (M4X16) and 1 machine screw (M4X8). (Fig.6)II III
    II III
    III
    10. Insert the fluorescent lamps and screw the night
    lamp into the lighting unit.(Fig.6)
    11. Insert mouting springs into slots as shown
    and mount grille to fan body.(Fig.7)
    Fig.6
    Plug connectorII
    Plug connectorIII
    Lighting unit
    Screw (M4X16)III
    Machine screw
    (M4X8)
    Plug connectorIII
    ReceptacleIII
    4 W Night Lamp
    Fluorescent lamps
    inches (mm)
    Slot
    Grille Mounting spring
    Fig.7
    Light unit
    Fig.8inches mm()
    Joists Adaptor
    2-Long screws
    (M4X30)
    2-Long screws(M4X30)Adaptor
    1. Disconnect plug connector from receptacle and
    remove adaptor from fan body before starting
    installation.
    2. Insert the suspension bracket into the adaptor and
    secure it to joists by using long screws(M4X30) (Fig.8)
    Keep the distance B (7/8 inch, 21.6mm) for the
    thickness of ceiling board.
    ReceptacleII
    8. Finish ceiling work. Ceiling hole should be aligned
    with the edge of the flange. (Fig.6)
    Plug connectorII
    10 7/8(275)
    10 7/8(275)
    Ceiling
    Ceiling
    A
    Suspension bracket13 1/4~15 1/2 ( 336~394 )
    16 1/2~18 3/4 ( 419~480 )
    21 1/4~23 1/2 ( 540~597 )
    If spacing A between joists is 21 1/4 to 23 1/2
    inches (540 to 597mm), connect suspension
    bracket and (C4 mark to C4 mark) according
    to page 8. Select the suspension bracket
    according to spacing A as show below.II III
    suspension
    bracketsuspension
    bracketIsuspension
    bracketIIIsuspension
    bracket &II III Spacing A
    between Joists
    inches (mm)13 1/4~15 1/2
    (336~394)16 1/2~18 3/4
    (419~480)21 1/4~23 1/2
    (540~597) 
    						
    							Make sure that adaptor claws are properly inserted
    into body slots.
    IMPORTANT:
    5. Insert the fan body into joists. (Fig.9)
    6. Secure the fan body to adaptor by using thumb
    screw and plug connector to receptacle(Fig.10)
    Fig. 10Thumb
    screwPlug connectorIReceptacleI
    Fig. 9
    When mounting
    body and blower
    separately
    1. Loosen 3 screws (but
    do not remove them
    from blower). (Fig.12-1)
    2. Remove blower section.
    (Fig.12-2)
    4. Insert fan body (without
    blower section) into joists
    (Fig.9)
    5. Secure the adaptor to
    fan body by using thumb
    screw. (Fig.10)
    7. Insert the blower into the
    fan body. (Fig.12-3)
    8. Secure the blower.
    (Fig.12-4) and plug
    connector to receptacle
    (Fig.10) 3. Remove adaptor from
    fan body and secure it
    to joists as in Fig.8 of
    page 8.
    Fig.12-2
    Fan body
    Blower
    Fan body
    Joist
    Fig.12-3
    Fig.12-1
    Adaptor 3-Screws
    Fig.12-4
    3-ScrewsScrew driver
    SlotsAdaptor
    claws Fan body Joist
    9
    7. Secure to joists by using
    long screws(M4X30) and secure it to fan body by
    using screw (M4X12) in vertical direction (Fig.11)the suspension bracket
    II
    8. Follow step 8 to 11 of Installation (page 8) to
    complete the installation work.I
    2-Long screws
    (M4X30)screw (M4X12)II
    Fig. 11
    Conduit
    Junction box cover
    Duct4. Insert to fan body (refering
    to step 2 of installation , page 6)the suspension bracket in
    I
    6. Secure the fan body
    to joists by using long
    screw(M4X30) (Fig.11)
    Duct tape 
    						
    							1. Before installation, secure the to by
    using thumb screw (Fig.13) Secure the lighting unit to
    fan body (refering to Fig.6 of page 8).fan body adaptor
    .
    10
    Fig.13
    Suspension bracket
    The suspension can comply with
    different kind of joists.III
    III
    I-bracket
    C
    2. Connect the suspension to fan body. (Fig.14)
    (Select the hole by checking -joist size and fix the
    screw to the frame hole.)bracketIII
    I
    C1
    C2
    C3
    C44 kinds of joist
    inches (mm)I-
    9/16 ( )14.3
    11/16 (17.5)
    31/32 (24.6)
    1 17/32 38.9()
    Thumb screw
    Fan body
    3. Connect the ventilating fan to the joist. (Fig.15)I-
    4. Follow step 5 to 11 of installation (page 7~page 8) to
    complete the installation work.I 1. Before installation, secure the to by
    using thumb screw (Fig.13) Secure the lighting unit
    to fan body (refering to Fig.6 of page 8).fan body adaptor
    .
    C3
    C4
    C1
    C2
    Fig.14
    Screw M4X12II ( )
    Suspension
    bracketIII
    Fig.154-Long screws(M4X30)I-joist
    Fig.16inches mm()
    2. Insert the suspension bracket into bracket cover of
    adaptor side and the back of the fan body. (Fig.16)
    (select the suspension bracket according to spacing A
    as show below)
    Suspension bracket
    Suspension bracketI
    III16 inches and 19.2 inches
    horizental joist
    19.2 inches vertical joist
    Suspension bracket
    Suspension bracketIII
    II16 inches and 19.2 inches
    horizental joist
    19.2 inches vertical joistSuspension bracket
    Suspension bracketII
    I16 inches and 19.2 inches
    horizental joist
    19.2 inches vertical joist
    A
    16 inches and 19.2 inches
    horizental joist
    19.2 inches vertical joist 
    						
    All Panasonic manuals Comments (0)