Ventilating Fan SpecificationsDimensions Description 12 11-12 13-14 14 6-84 4-54 32 2 Table of Contents Supplied Accessories Unpacking General Safety Information I Installation( Wooden Header ) 10III( -Joist Mounting )I 10-11Installation ( Between Joist Mounting ) Installation( In Existing Construction )VI Installation( Joist Mounting- )I Installation Maintenance Practical Guide to Installation 14Product Service FV-08VKL1 8-9II( Joist Mounting- )II Installation IV V READ AND SAVE THESE INSTRUCTIONS.R Please readthese instructionscarefullybeforeattempting toinstall, operate or service the Panasonic Ventilating Fan. Failure to comply with instructions could result in personal injury and/or property damage. Please retain this booklet for future reference.
FV-08VKL1 Quantity Appearance Part name Screw (M4X8)I21 Grille Suspension bracketI Suspension bracketII 1 1 2Screw (M4X12)II Screw (M4X16)III 2 Machine screw (M4X8)1 Quantity Appearance Part name 2 1 1 18W Fluorescent lamp 4W Night lamp Lighting unit These Panasonic ceiling mount ventilating fan models use a sirocco fan with dolphin-shaped blades driven by brushless direct current motor. The motor is designed to have long operating life, high dynamic response, higher speed ranges with saving eneray. The grille can be quickly detached from the main unit. A damper for preventing air counterflow is provided. The blower uses a high-capacity sirocco fan developed to reduce the noise level. The light unit is an energy-saving, lighting device which uses two 18W fluorescent lamps and produces almost the same illumination as a standard 100W incandescent lamp. 1Suspension bracketIII 1 8Thumb screwLong screw (M4X30)
FV-08VKL1 Junction box cover Junction box Lighting unit assy Fluorescent lamp Night lamp Part name No. Part nameNo. 1 2 3 4 5 67 8 9 10 11 Damper Fan bodyAdaptor Grille Suspension bracket Bracket cover Unit: ( )inches mm 7 3 1/2 (90)1 (25) 5 1/8 130() 7 7/8 200() 13/4 45() 126() 6 13 330() 10 1/4 261() 3 1/2 (90)27/873() 8 9 1110 37/8 98()10 1/4 (261) 12 1/8 (307) 3 1/4 (81) (For 16 inches on center joists,only use suspension bracket , for 19.2 inches on center joists, only use suspension bracket , If more than 19.2 inches on center,use suspension bracket & .)I III II III 13 1/4~15 1/2 ( 336~394 ) 16 1/2~18 3/4 ( 419~480 ) 21 1/4~23 1/2 ( 540~597 )
Specifications are based on HVI standard. Unpack and carefully remove unit from carton. Refer to the Supplied Accessories list to verify that all parts are present. 1. Do not install this ventilating fan where air temperature may exceed 40 C (104 F).oo 2. Make sure that the electric service supply voltage is 120V, 60 Hz. 3. Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and the Occupation Safety and Health Act (OSHA). 4. Always disconnect the power source before working on or near the fan, motor or light fixture. 5. Protect the power cord from sharp edges, oil, grease, hot surfaces, chemicals or other objects. 6. Do not kink the power cord. 7. Do not install the unit where ducts are configured as shown in Fig. A. 8. Provide suction parts with proper ventilation. 9. This unit is approved for use over a bathtub or shower when installed in a GFCI protected branch circuit. FV-08VKL1 Noise (sone) Duct diameter (inches) 4
CAUTION: 1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. 2. Not for use in cooking area. (Fig .B) 3. This product must be properly grounded. Floor Do not install above or(Cooking area) inside this area 45o45o equipmentCooking Fig. B WARNING: To reduce the risk of fire, electric shock or injury to persons, observe the following; A. Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer. B. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction. C. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturers guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities. D. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. E. Ducted fans must always be vented to the outdoors. F. These models are UL listed for tub and shower enclosures. G. Solid state controls may cause harmonic distortion which can cause motor humming noise. Do not use this unit with any solid-state control device. H. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. I. NEVER place a switch where it can be reached from a tub or shower. J. Not to be installed in a ceiling thermally insulated to a value greater than R40.
1. Before installation, secure the fan body to adaptor by using thumb screw. (Fig.1) Remove the tape IMPORTANT : Adaptor Remove the tape from damper and adaptor before installation. As show below: Damper 2-Screw (M4X8)I Suspension bracketIIISuspension bracketII 6 Fig.1 Suspension bracketI Suspension bracketIII Suspension bracketISuspension bracketIII Suspension bracketI Fig.2-1 Fig.2-2 Fig.2-3 Fig.2-4Fan body Fan body Fan body Fan body Suspension bracketI Suspension bracketIII Suspension bracketII Fan body Thumb screw 2. Insert the supension bracket into the fan body and adaptor. (select the suspension bracket as show below) Spacing A on center Joists Insert Suspension bracket 12 inches 16 inches 19.2 inches vertical joists 24 inchesRefer to Fig. 2-1 Refer to Fig. 2-2 Refer to Fig. 2-3 Refer to Fig. 2-4 If spacing A on center joists is 24 inches, connect suspension bracket and (C4 mark to C4 mark) as show below :II III Joists A
Main PCB Junction box Fan body Power supply AC120V 60Hz Black White Red Green Black WhiteLive Neutral Ground M Black White Black WhiteCurrent Fuse Electronic BallastLive Neutral Live Neutral Wiring diagram Lighting unit Black Red Blue Fluorescent Lamp Night Lamp 3.15A Fig.3-2 Fig.4 4. Install the suspension bracket to joists by using long screws (M4X30) and secure it to the fan body by using screw (M4X12) (Fig.4)II Fan body Joist 4-Long screws(M4X30) Joist Fan body 2-Long screws (M4X30) 2-Long screws (M4X30) screw (M4X12)II 7 Junction box cover Fig. 5 ConduitDuct 5. Remove junction box cover and secure conduit or stress relief to junction box knock-out hole. (Fig.5) 6. Refer to wiring diagram below. Using wire nuts, connect house power wires to ventilating fan wires: black to black; white to white; green to green; Replace the junction box cover. CAUTION: Mount junction box cover carefully so that lead wires are not pinched. 7. Install a circular duct and secure it with duct tape or clamps. Fig.3-1 Wire nut Conduit Junction box Green wires Lead wires 3. Install the suspension bracket and the flange of fan body to joists by using long screws (M4X30) ( If spacing A between joists is 12 inches, install the flange of fan body according to Fig.3-2, others according to Fig.3-1 to install the product) Duct tape 3. Instale la abrazadera de suspension y la brida del cuerpo del ventilador a las vigas usando los tornillos largos (M4X30) (Si el espacio A entre las vigas es de mas de 12 pulgadas, instalar el costado del cuerpo del ventilador siguiendo la muestra en la Fig. 3-2, para otras dimensiones instale el producto de acuerdo a la Fig. 3-1)
3. Follow step 5 to 7 of the installation (page 7) to complete the duct work and wiring.I 8 9. Insert the plug connector and plug connector into the receptacle and receptacle respectively, and secure the light unit to the fan unit with 2 screw (M4X16) and 1 machine screw (M4X8). (Fig.6)II III II III III 10. Insert the fluorescent lamps and screw the night lamp into the lighting unit.(Fig.6) 11. Insert mouting springs into slots as shown and mount grille to fan body.(Fig.7) Fig.6 Plug connectorII Plug connectorIII Lighting unit Screw (M4X16)III Machine screw (M4X8) Plug connectorIII ReceptacleIII 4 W Night Lamp Fluorescent lamps inches (mm) Slot Grille Mounting spring Fig.7 Light unit Fig.8inches mm() Joists Adaptor 2-Long screws (M4X30) 2-Long screws(M4X30)Adaptor 1. Disconnect plug connector from receptacle and remove adaptor from fan body before starting installation. 2. Insert the suspension bracket into the adaptor and secure it to joists by using long screws(M4X30) (Fig.8) Keep the distance B (7/8 inch, 21.6mm) for the thickness of ceiling board. ReceptacleII 8. Finish ceiling work. Ceiling hole should be aligned with the edge of the flange. (Fig.6) Plug connectorII 10 7/8(275) 10 7/8(275) Ceiling Ceiling A Suspension bracket13 1/4~15 1/2 ( 336~394 ) 16 1/2~18 3/4 ( 419~480 ) 21 1/4~23 1/2 ( 540~597 ) If spacing A between joists is 21 1/4 to 23 1/2 inches (540 to 597mm), connect suspension bracket and (C4 mark to C4 mark) according to page 8. Select the suspension bracket according to spacing A as show below.II III suspension bracketsuspension bracketIsuspension bracketIIIsuspension bracket &II III Spacing A between Joists inches (mm)13 1/4~15 1/2 (336~394)16 1/2~18 3/4 (419~480)21 1/4~23 1/2 (540~597)
Make sure that adaptor claws are properly inserted into body slots. IMPORTANT: 5. Insert the fan body into joists. (Fig.9) 6. Secure the fan body to adaptor by using thumb screw and plug connector to receptacle(Fig.10) Fig. 10Thumb screwPlug connectorIReceptacleI Fig. 9 When mounting body and blower separately 1. Loosen 3 screws (but do not remove them from blower). (Fig.12-1) 2. Remove blower section. (Fig.12-2) 4. Insert fan body (without blower section) into joists (Fig.9) 5. Secure the adaptor to fan body by using thumb screw. (Fig.10) 7. Insert the blower into the fan body. (Fig.12-3) 8. Secure the blower. (Fig.12-4) and plug connector to receptacle (Fig.10) 3. Remove adaptor from fan body and secure it to joists as in Fig.8 of page 8. Fig.12-2 Fan body Blower Fan body Joist Fig.12-3 Fig.12-1 Adaptor 3-Screws Fig.12-4 3-ScrewsScrew driver SlotsAdaptor claws Fan body Joist 9 7. Secure to joists by using long screws(M4X30) and secure it to fan body by using screw (M4X12) in vertical direction (Fig.11)the suspension bracket II 8. Follow step 8 to 11 of Installation (page 8) to complete the installation work.I 2-Long screws (M4X30)screw (M4X12)II Fig. 11 Conduit Junction box cover Duct4. Insert to fan body (refering to step 2 of installation , page 6)the suspension bracket in I 6. Secure the fan body to joists by using long screw(M4X30) (Fig.11) Duct tape
1. Before installation, secure the to by using thumb screw (Fig.13) Secure the lighting unit to fan body (refering to Fig.6 of page 8).fan body adaptor . 10 Fig.13 Suspension bracket The suspension can comply with different kind of joists.III III I-bracket C 2. Connect the suspension to fan body. (Fig.14) (Select the hole by checking -joist size and fix the screw to the frame hole.)bracketIII I C1 C2 C3 C44 kinds of joist inches (mm)I- 9/16 ( )14.3 11/16 (17.5) 31/32 (24.6) 1 17/32 38.9() Thumb screw Fan body 3. Connect the ventilating fan to the joist. (Fig.15)I- 4. Follow step 5 to 11 of installation (page 7~page 8) to complete the installation work.I 1. Before installation, secure the to by using thumb screw (Fig.13) Secure the lighting unit to fan body (refering to Fig.6 of page 8).fan body adaptor . C3 C4 C1 C2 Fig.14 Screw M4X12II ( ) Suspension bracketIII Fig.154-Long screws(M4X30)I-joist Fig.16inches mm() 2. Insert the suspension bracket into bracket cover of adaptor side and the back of the fan body. (Fig.16) (select the suspension bracket according to spacing A as show below) Suspension bracket Suspension bracketI III16 inches and 19.2 inches horizental joist 19.2 inches vertical joist Suspension bracket Suspension bracketIII II16 inches and 19.2 inches horizental joist 19.2 inches vertical joistSuspension bracket Suspension bracketII I16 inches and 19.2 inches horizental joist 19.2 inches vertical joist A 16 inches and 19.2 inches horizental joist 19.2 inches vertical joist