Panasonic Ventilating Fan Fv08vkml1 Installation Instructions

    Download as PDF Print this page Share this page

    Have a look at the manual Panasonic Ventilating Fan Fv08vkml1 Installation Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							3. Follow steps 4 to 6 of the installation (page 9) to
    complete the duct work and wiring.I
    1. Remove the machine screw by using screw driver,
    disconnect plug connector from receptacle and
    remove adaptor from fan body before installation.
    (Fig.8)
    If spacing A between joists is 21 1/4 to 23 1/2
    inches (540 to 597mm), connect suspension
    bracket and (C4 mark to C4 mark) according
    to page. 8 Select the suspension bracket
    according to spacing A as shown below.II III
    suspension
    bracketsuspension
    bracketIsuspension
    bracketIIIsuspension
    bracket &II III Spacing A
    between Joists
    inches (mm)13 1/4~15 1/2
    (336~394)16 1/2~18 3/4
    (419~480)21 1/4~23 1/2
    (540~597)
    11
    INSTALLATION JOIST MOUNTING-II II()INSTALLATION JOIST MOUNTING-II II()
    Make sure that adaptor claws are properly inserted
    into body slots.
    IMPORTANT:
    5. Insert the fan body into joists. (Fig.10)
    4. Insert to fan body (refering
    to step 1 of installation , page 8)the suspension bracket in
    I
    Fig.9inches mm()
    Suspension bracket 2 Long screws
    (ST4.2X20)
    Adaptor Joists 2 Long screws
    (ST4.2X20)Adaptor13 1/4~15 1/2 ( 336~394 )
    16 1/2~18 3/4 ( 419~480 )
    21 1/4~23 1/2 ( 540~597 )
    A
    Gloves
    Gloves
    1/2 (12.7)
    2. Insert the suspension bracket into the adaptor and
    secure it to joists by using long screws (ST4.2X20) (Fig.9)
    Keep the distance B (1/2 inch, 12.7mm) for the thickness
    of ceiling board.Suspension
    bracketI
    Fan body
    Machine screw
    Fig.8
    Fig.10
    SlotsAdaptor
    claws Fan body Joist
    Conduit
    Junction box cover
    Circular duct
    Duct tape
    Gloves
    Screw driver 
    						
    							2. Connect the suspension to fan body. (Fig.13)
    (Select the hole by checking -joist size and fix the
    screw to the frame hole.)bracketIII
    I
    3. Connect the fan body to the joist. (Fig.14)I-
    4. Follow steps 4 to 12 of installation (page 9, page 10) to
    complete the installation work.I 1. Before installation, secure the lighting unit to fan body
    (refering to Fig.5 of page 10).
    C
    Suspension bracket
    The suspension can comply with
    different kind of joists.III
    III
    I-bracket
    C3
    C4
    C1
    C2
    C1
    C2
    C3
    C44 kinds of joist
    inches (mm)I-
    9/16 ( )14.3
    11/16 (17.5)
    31/32 (24.6)
    1 17/32 38.9()
    INSTALLATION JOIST MOUNTING- CONTINUEDII II()INSTALLATION JOIST MOUNTING- CONTINUEDII II()
    12
    INSTALLATION JOIST MOUNTINGIII I(- )INSTALLATION JOIST MOUNTINGIII I(- )
    7. Secure to joists by using
    long screws(ST4.2X20) and secure it to fan body by
    using screw (ST4.2X12) in vertical direction (Fig.12)the suspension bracket
    II
    8. Follow steps 7 to 12 of Installation (page 10) to
    complete the installation work.I
    Fig.14
    4 Long screws (ST4.2X20)I-joist
    Fig.13
    Screw ST4.2X12() II Suspension
    bracketIII
    6. Secure the fan body to adaptor by using machine
    screw and plug connector to receptacle (Fig.11)
    Fig.12
    2 Long screws
    (ST4.2X20)Screw (ST4.2X12)II
    2 Long screws
    (ST4.2X20)
    Screw driver
    Plug connectorIReceptacleI Machine screw
    Fig.11 
    						
    							Suspension bracketI
    Suspension bracketIIISuspension bracketII
    2. Insert the suspension bracket into bracket cover of
    adaptor side and the back of the fan body. (Fig.15)
    (select the suspension bracket according to spacing A
    as shown below)
    A16 inches and 19.2 inches
    horizental joist
    19.2 inches vertical joist
    13
    INSTALLATION JOIST MOUNTINGIV( BETWEEN )INSTALLATION JOIST MOUNTINGIV( BETWEEN )
    3. Insert the fan body between joists. Make sure the fan
    body is level and square (perpendicular) with the joists.
    (Fig.16)
    4. Secure the suspension bracket to joists by using long
    screws(ST4.2X20) (Fig.17, Fig.18)
    5. Secure the suspension bracket to fan body by using
    screw (ST4.2X12) (Fig.18)II
    6. Follow steps 4 to 12 of installation (page 9, page 10)
    to complete the installation work.I
    Fig.17
    2 Long screws (ST4.2X20)
    Joist
    4 Long screws (ST4.2X20)2 Screw
    (ST4.2X12)II
    Fig.18
    Joists
    Fig.16
    Junction box Fan bodyAdaptor
    inches mm()
    A13 1/4~15 3/4 ( 336~400 )
    16 1/2~18 3/4 ( 419~480 )
    3~5 ( 76~126 )
    5 4/5~7 4/5 ( 148~198 )
    B
    1/2 (12.7)
    Fig.15-1
    Fig.15-2
    Suspension bracketIII
    Suspension bracketIISuspension bracketI
    16 inches and 19.2 inches
    horizental joist
    19.2 inches vertical joist
    Keep the distance B (1/2 inch, 12.7mm) for the thickness
    of ceiling board.
    1. Before installation, secure the lighting unit to fan body
    (refering to Fig.5 of page 10). 
    						
    							Wire nut Green wires
    Lead wiresRed wires
    ConduitJunction boxJunction box
    Wire nut Lead wires
    Conduit
    Green wires
    14
    INSTALLATION WOODEN HEADEV(R)INSTALLATION WOODEN HEADEV(R)
    4. Follow steps 4 to 12 of installation (page 9, page 10)
    to complete the installation work.I
    3. Install the fan body and secure it by using long
    screws(ST4.2X20) (Fig.19, Fig.20)
    (275)(375)10 7/814 3/4
    Joist Header Joist2. Install header between joists by using nails or screws.
    inches (mm)Fig.19
    Adaptor
    Fan body
    INSTALLATION IN EXISTING CONST UCTIONVI(R)INSTALLATION IN EXISTING CONST UCTIONVI(R)
    (1) To install the fan body, follow the procedures described in lnstallation . Take the following
    precautions before installation.II
    1. Installation in existing construction.
    Installing the fan body in an existing building requires an accessible area (attic or crawl space) above
    the planning installation location or existing ducting and wiring.
    (2) Inspect duct work and wiring before proceeding with installation.
    (3) Plan suitable location for fan body. (next to ceiling joist)
    (5) First, remove ceiling section.
    (6) Install fan body.
    (1) Inspect duct work and wiring before proceeding with installation.
    (2) Remove ceiling section.
    (3) Install fan body.
    CAUTION:
    Check area above the planned installation location to be sure that:
    1. Duct work can be done and that area is sufficient for proper ventilation.
    2. Wiring can be run to the planned location.
    3. No wiring or other obstructions shall interfere with installation.
    (4) Before installation, provide inspection and maintenance access at a location that will not interfere
    with installation work shown in installation .II
    2. Installation from accessible area above fan location.
    Fig.20
    6 Long screws
    (ST4.2X20)Adaptor
    Circular duct
    1. Before installation, secure the lighting unit to fan body
    (refering to Fig.5 of page 10). 
    						
    							15
    MAINTENANCE CLEANINGI()MAINTENANCE CLEANINGI()
    Fig.22
    4. Remove dust and dirt from fan body using a vacuum
    cleaner. (Fig.24)
    5. Using a cloth dampened with kitchen detergent, remove
    any dirt from fan body. Wipe dry with new cloth. (Fig.25)
    6. Replace grille.
    Fig.24
    Fig.25
    Fig.23
    3. The grille should be dry after cleaning. (Fig.23)
    2. Wash and clean grille. (Use non-abrasive kitchen detergent,
    wipe dry with new cloth.) (Fig.22)
    MAINTENANCEII(REPLACEMENT OF LAMP)MAINTENANCEII(REPLACEMENT OF LAMP)
    1. Disconnect power source before working on unit.
    2. The lamps glass is fragile. Please handle with care. To remove lamp, grasp at base and move back
    and force to loosen.Do not pull hard on the lamp or you may break the glass.
    3. 4W night lamp has threaded base. Remove by turning counterclockwise.
    4. Be sure to remove the night lamp before remove fluorescent lamps.
    Disconnect power source before working on unit. Routine
    maintenance must be done every year.
    WARNING:
    CAUTION:
    1. Never use gasoline, benzene, thinner or any other
    such chemicals for cleaning the ventilating fan.
    2. Do not allow water to get into the motor.
    3. Do not soak resin parts in water over 60 C (140 F).
    oo
    Glove
    Gloves
    Vacuum cleaner
    GrilleGloves
    Sensor unit
    Grille
    Ceiling
    Gloves
    Mounting springCeiling
    Fig.21-1
    Fig.21-2
    1. Remove grille pull down one mounting spring. Remove
    sensor unit then pull down the other mounting spring.
    (Squeeze mounting spring and pull down carefully.) (Fig.21) 
    						
    							Warning Concerning Removal of Covers.
    The unit should be serviced by qualified technicians only. No service information is provided for customers.
    Your product is designed and manufactured to ensure a minimum of maintenance. However, should your
    unit ever require service, a nationwide system of factory service centers and AUTHORIZED INDEPENDENT
    SERVICE CENTERS is maintained to support your products warranty.
    (In the U.S.A.,call 1-866-292-7292 to Customer call Center.)
    P ODUCT SE VICERRP ODUCT SE VICERR
    3. Change the fluorescent lamps (Panasonic FDS
    18E27/4,18W or FDS18E35/4, 18W or FDS18E42/4,
    18W ) or the 4W night lamp, connect the plug
    connector and replace the grille.(Fig.27)II 1. Remove grille. (Squeeze mounting spring and pull
    down) (Fig.21 of page 15)
    Fig.28
    Loose fill or batt insulation can be placed
    directly over the fan housing in the attic.
    Panasonic fans and fan/light combination
    units do not create excessive heat that is
    a common problem with recessed light
    fixtures or some competitors fan/light
    combinations. Our efficient, cool-running
    motors and our fluorescent bulbs do not
    create enough ambient heat to be subjected
    to these limitations.
    Proper insulate the area around the fan to
    minimize building heat loss and gain. (Fig.28)Dryer-hood type vent with
    backdraft flap(s).
    Caulk termination to duct.
    2-3 ft straight run before elbow.
    In attic installation,
    caulk box to drywall.
    Short piece of flexible duct
    helps alignment and absorbs
    sound. Clamps plus tape at
    all flex joints.Foil tape tightly covers all metal
    duct joints (glue PVC joints).Insulation.
    P ACTICAL GUIDE TO INSTALLATIONRP ACTICAL GUIDE TO INSTALLATIONR
    MAINTENANCEII(REPLACEMENT OF LAMP) CONTINUEDMAINTENANCEII(REPLACEMENT OF LAMP) CONTINUED
    X0108-0 08VKML420
    PANASONIC CONSUMER ELECTRONICS COMPANY
    Division of Panasonic Corporation of North America,
    PANASONIC CANADA INC.
    5770 Ambler Drive, Mississauga, ON L4W 2T3 www.panasonic.com One Panasonic Way, Secaucus, NJ 07094
    2. Remove the 4 W night lamp. (Fig.26)
    Fig.26
    Fig.27
    Gloves
    www.panasonic.ca 
    						