Panasonic Ventilating Fan Fv08vkml1 Installation Instructions
Here you can view all the pages of manual Panasonic Ventilating Fan Fv08vkml1 Installation Instructions. The Panasonic manuals for Ventilation are available online for free. You can easily download all the documents as PDF.
Page 1
READ AND SAVE THESE INSTRUCTIONS.R Please readthese instructionscarefullybeforeattempting toinstall, operate or service the Panasonic Ventilating Fan. Failure to comply with instructions could result in personal injury and/or property damage. Please retain this booklet for future reference. 15-16 16 8-107 Table of Contents Unpacking General Safety Information 14VInstallation( Wooden Header ) 12 14 Installation( In Existing Construction )VI IInstallation( Joist Mounting- )I III( -Joist Mounting )I...
Page 2
than the minimum ENERGY STAR requirements. 5 efficient FV-08VKSL1 FV-08VKML1 only). ventilating
Page 3
These Panasonic ventilating fans use a sirocco fan with dolphin-shaped blades driven by brushless direct current motor powered by an integral transformer. The motor is designed to have long operating life, high dynamic response, higher speed ranges with saving energy. The grille can be quickly detached from the main unit. A damper for preventing air counterflow is provided. The blower uses a high-capacity sirocco fan developed to reduce the noise level. SUPPLIED ACCESSORIES UNPACKING DESCRIPTION The...
Page 4
DIMENSIONS Unit: ( )inches mm (For 16 inches on center joists, only use suspension bracket , for 19.2 inches on center joists, only use suspension bracket , If more than 19.2 inches on center, use suspension bracket & .)I III II III Junction box cover Junction box Lighting unit Fluorescent lamp Night lamp Part name No.Part name No. 1 2 3 4 5 67 8 9 10 11 Damper Fan bodyAdaptor Grille Suspension bracket Bracket cover 12Sensor unit FV-08VKSL1 FV-08VKML1 6 13 330() 10 1/4 261() 3 1/2 (90) 8 9 10 37/8 98()10...
Page 5
SWITCH INDICATION 30 40 50 60 70 80 Delay Time [min] WI ING DIAG AMRRWI ING DIAG AMRR Low speed air-volume preset switch positions Air Volume [cfm] High/Low delay time preset switch positions 0.5 1235 10 2030 60 Factory setting : 20 minutes Position 0 : Use for factory test only. 0 Factory setting : 50 cfm Switch indications on blower unit Low speed air vol- ume preset switch High / Low delay time preset switch FV-08VKML1 FV-08VKSL1 White White Position use for factory test only. CFM
Page 6
Duct diameter (inches) 416.5 7.5() (cfm)(rpm) FV-08VKML1 FV-08VKSL1 9.5 7.7 6.5 5.8 5.0 70 60 50 40 30 700 666 647 628 620
Page 7
CAUTION: 1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. 2. Not for use in cooking area. (Fig. B) 3. This product must be properly grounded. 45o45o Floor Do not install above or(Cooking area) inside this area equipmentCooking Fig. B 3. Follow all local electrical and safety codes, as well as the National Electrical Codethe Occupation Safety and Health Act (OSHA). (NEC) and 4. Always disconnect the power source before working on or near the fan,...
Page 8
8 2-Screw (ST4.2X8)I Suspension bracketIIISuspension bracketII INSTALLATION JOIST MOUNTING-II()INSTALLATION JOIST MOUNTING-II() 1. Insert the suspension bracket into the fan body and adaptor. (select the suspension bracket as shown below) Spacing A on center joists Insert Suspension bracket 12 inches 16 inches 19.2 inches vertical joists 24 inchesRefer to Fig. 1-1 Refer to Fig. 1-2 Refer to Fig. 1-3 Refer to Fig. 1-4 If spacing A on center joists is 24 inches, connect suspension bracket and (C4 mark to...
Page 9
Fan body 4 Long screws (ST4.2X20) Joist 9 Fig.2-2 INSTALLATION JOIST MOUNTING-II( ) CONTINUEDINSTALLATION JOIST MOUNTING-II( ) CONTINUED 3. Install the suspension bracket to joists by using long screws (ST4.2X20) and secure it to the fan body by using screw (ST4.2X12) (Fig.3)II Junction box cover Fig.4 ConduitCircular duct 4. Remove junction box cover and secure conduit or stress relief to junction box knock-out hole. (Fig.4) CAUTION:Mount junction box cover carefully so that lead wires are not pinched....
Page 10
10 7/8(275) 10 7/8(275) Ceiling Sensor unitGrille Ceiling Fig.6-2 Gloves INSTALLATION JOIST MOUNTING-II( ) CONTINUEDINSTALLATION JOIST MOUNTING-II( ) CONTINUED 8. Insert the plug connector into the receptacle , and secure the lighting unit to the fan body with 1 screw (ST4.2X16) and 2 machine screws (M4X8). (Fig.5)II II III 9. Insert the fluorescent lamps and s cure the night lamp into the lighting unit. (Fig.5)e 12. Insert mounting springs into the slots as shown and mount grille to fan body....