Home > Panasonic > Ventilation > Panasonic Ventilating Fan Fv-08vsl2, Fv-10vsl2 Installation Instructions

Panasonic Ventilating Fan Fv-08vsl2, Fv-10vsl2 Installation Instructions

    Download as PDF Print this page Share this page

    Have a look at the manual Panasonic Ventilating Fan Fv-08vsl2, Fv-10vsl2 Installation Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							FV-08VSL2  
    FV-10VSL2 INSTALLATION  INSTRUCTIONS
      
    Ventilating Fan
    Model No.
    READ AND SAVE THESE INSTRUCTIONS Contents
    Description
    Dimensions General Safety lnformation
    Unpacking
    Wiring Diagram
    lnstallation    (Joist Mounting-  )
    lnstallation    (Joist Mounting-   )
    lnstallation    (   -Joist Mounting)
    lnstallation     (Between Joist Mounting )
    lnstallation    (Wooden Header )
    lnstallation     (ln Existint Construction )
    Maintenance   (cleaning)
    Maintenance     (replacement of lamp)
    Practical Guide to lnstallation
    Product Service2-3
    4
    4
    4
    5
    5
    6-8 8-9
    10
    10-11
    11-12
    12
    13
    13-14
    14
    15 15
    Supplied Accessories
    Specifications
    Thank you very much for having purchased our product.
    Please read these instructions carefully before attempting to install, operate or service 
    the Panasonic product. Failure to comply with instructions could result in personal injury 
    or property damage. Please explain to users how to operate and maintain the product 
    after installation, and this booklet should be presented to users.
    Please retain this booklet for future reference. 
    						
    							GENERAL SAFETY INFORMATION
    2 To reduce the risk of fire, electric shock or injury to persons, observe\
     the following:
    9. Do not use this fan with any solid-state speed control device. 2. Before servicing or cleaning unit, switch power off at service panel \
    and lock the service 
        disconnecting means to prevent power from being switched on accident\
    ally. When the service 
        disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, 
        to the service panel. 
    7. If this unit is to be installed over a tub or shower, it must be mark\
    ed as appropriate for the 
        application and be connected to a GFCI (Ground Fault Circuit lnterr\
    upter) - protected branch circuit. 
    10. Canada only: Not to be installed in a ceiling thermally insulated to a value greater than R40.
    15. Do not install the product as the method which is not approved in th\
    e instruction.  11. Do not disassemble the unit for reconstruction. lt may cause fire or electric shock.
    12. A statement to the effect that when the product is to no longer be u\
    sed, it must not be left in 
          place but removed, to prevent it from possibly falling.  14 . The special-purpose or dedicated parts, such as mounting fixtures, must be used if such parts are 
          provided.  3. Installation work and electrical wiring must be done by qualified per\
    son (s) in accordance with all
        applicable codes and standards, including fire-rated construction. 
    5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
    6. Ducted fans must always be vented to the outdoors. 
    8. These models are UL listed for tub and shower enclosures. 4. Sufficient air is needed for proper combustion and exhausting of gase\
    s through the flue (chimney)
        of fuel burning equipment to prevent back drafting. Follow the heati\
    ng equipment manufacturer s
        guideline and safety standards such as those published by the Nation\
    al Fire Protection Association
        (NFPA), and the American Society for Heating, Refrigeration and Ai\
    r Conditioning Engineers
        (ASHRAE) and the local code authorities. 
    
    WARNING:
    1. Use this unit only in the manner intended by the manufacturer. lf you\
     have any questions, contact
        the manufacturer.
    13. Ceiling joist must be subjected to static load more than five times \
    the weight of the product. 
    16. This product must be properly grounded. 
    						
    							GENERAL SAFETY INFORMATION CONTINUED
    3
    11. USA only: This product has a fluorescent lamp that contains mercury. Disposal may be regulated in 
           your community  due to environmental considerations. For disposal\
     or recycling information, please 
           contact your local authorities or visit Panasonic website: http:/\
    /www.panasonic.com/enveronmental 
           or call 1-888-769-0149. 1. Do not install this ventilating fan where interior room temperature m\
    ay exceed 104  F (40  C).
    2. Make sure that the electric service supply voltage is AC 120V, 60 Hz.
    3. Follow all local electrical and safety codes, as well as the National\
     Electrical Code (NEC) and the
        Occupation Safety and Health Act (OSHA).
    4. Always disconnect the power source before working on or near the fan, motor, light fixture or 
        junction box.
    5. Protect the supply wiring from sharp edges, oil, grease, hot surfaces, chemicals or other objects.
    6. Do not kink the supply wiring.
    7. Provide make up air for proper ventilation.
    8. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
    10. Not for use in cooking area. (Fig. B) CAUTION: Prohibition
    Prohibition Prohibition ProhibitionAdaptor
    Fig. A      (Cooking area)
    Do not  install above or 
          inside this  area
          Cooking
        equipment       Floor
    4545
    Fig. B
    9. Do not install the unit where ducts are configured as shown in Fig. A. 
    						
    							FV-08VSL2
         FV-10VSL2 SUPPLIED ACCESSORIES
    Part name Part name
    Appearance Appearance
    Quantity Quantity
    Grille
     Suspension
       bracket    Suspension
       bracket  
     Suspension
      bracket  
      Screw
    (ST4.2X8) 
      Screw
    (ST4.2X12)  1
    1
    1
    1
    2
    2
      Screw
    (ST4.2X16)    Machine screw
            (M4X8) 
            Long screw
            (ST4.2X20) 
            32W
      Fluorescent
            lamp
            4W
     Night lamp
            Lighting unit 2
    2
    6
    1
    1
    1UNPACKING
    Unpack and carefully remove unit from carton.
    Refer to the Supplied Accessories list to verify that all parts are present.
    4 DESCRIPTION
    These products are listed by UL under UL file No. E78414.
    These products use a sirocco fan driven by a capacitor motor. The motor is designed to have an extended 
    service life with reduced energy consumption. lt also incorporates a the\
    rmal-cutoff for safety. 
    The grille covering the main body is a spring-loaded, quick-release type\
    . 
    A damper for preventing counterflow is provided.
    The lighting unit is an energy-saving lighting device which uses one 32W\
     fluorescent lamp and produces 
    almost the same illumination as a standard 100W incandescent lamp. This product contains electronic ballast with one fluorescent lamp and is in compliance with Part 18 of 
    the FCC rules as consumer RF lighting device. Operation is subject to th\
    e following two conditions: 
    (1) This device may not cause harmful interference. 
    (2) this device must accept any interference received, including inter\
    ference that may cause undesired 
          operation.
    This product may cause interference to radio equipment and should not be\
     installed near maritime safety 
    communications equipment or other critical navigation or communication e\
    quipment operating between 
    0.45-30 MHz. lf interference should occur, try to increase spacing betwe\
    en this product and the other 
    product.
        
    Doc Responsible Party:            Panasonic Corporation of North America\
                                                       One Panasonic Way, Se\
    caucus, NJ 07094
    Sales Company:                        Panasonic Corporation of North Ame\
    rica
                                                       One Panasonic Way, Se\
    caucus, NJ 07094
    Customer Call Support:           1-866-292-7292 
    						
    							FV-08VSL2
      
    FV-10VSL2
    FV-10VSL2
    WIRING DIAGRAM 6  5/16 (160)
    2
    3 45
    6
    713 (330)
    5  17/32 (140)
    12 (300)
    10  1/4 (261)
    4  7/10(118.5)
    2  7/8 (73)2  3/8 (60)
    3  1/4 (82.6)
    1   (25)
    1011
    12
    3  6/8 (95) 3  1/8 (78)
    3  1/8 (78)
    FV-08VSL2 DIMENSIONS
    Unit: inches(mm)9
    8 10  1/4 (261)
    3  3/4 (94)
    13 (330) No. Part name
    No.Part name
    Grille
    Fan
    Lighting unit
    Junction box cover
    Adaptor
    Fluorescent lamp Fan body
    Damper Suspension bracket Junction box Bracket cover Night lamp
    7
    8
    9
    10
    11
    12
    1
    2
    3
    4
    5
    6
    (For 16 inches on center joists, only use suspension bracket     For 19.2 inches on center joists, only 
    use suspension bracket       lf more than 19.2 inches on center joists, use suspension bracket             ) 5Wiring diagram
    White Black Electronic  ballast Fluorescent
    lamp 
    Lighting unit
    Black Black
    Black Black
    White
    White
    White Black
    White Night lamp 
    Live  (Light)
    Neural
    Earth ground
    Junction box
    White Capacitor
    Red
    Fan body
    Fuse in motor
    Thermally protected
    Power supply
    AC120V 60Hz
    Green Green
    Live  (N.Light)
    Neural
    LiveMotor
    13  1/4~15  1/2 (336~ 394)
    16  1/2~ 18  3/4 (419~ 480)
    21  1/4~ 23  1/2 (540~ 597)  
    						
    							lf spacing A on center joists is 24 inches, connect
    suspension bracket 
       and    (C4 mark to C4 mark)
    as shown below:
    2 Screw   (ST4.2X8) Suspension bracket
    Suspension bracketINSTALLATION   (JOIST MOUNTING-  )
    1. Before installation, secure the fan body to adaptor by
        using machine screw(M4X8). (Fig.1) 
    IMPORTANT:
    Remove the tape from damper and adaptor 
    before installation. As shown below:   Tape
    Adaptor Damper2. lnsert the suspension bracket into the fan body and
        adaptor. (Select the suspension bracket as shown below) Joists
    Spacing A on center joists
    24 inches  12 inches
    16 inches
    19.2 inches vertical joists lnsert Suspension bracket
    Refer to Fig. 2-1
    Refer to Fig. 2-2
    Refer to Fig. 2-3
    Refer to Fig. 2-4 Suspension 
    bracket
    Suspension 
    bracket
    Fan body Suspension 
    bracket
    Fig. 2-4Machine screw
         (M4X8)
    Fan bodyFig. 1 Fig. 2-1Fan body
    Suspension 
    bracket Fig. 2-2Suspension 
    bracket
    Fan body Suspension 
    bracket
    Fan bodySuspension 
    bracket
    Suspension 
    bracket
    Fig. 2-3
    6 
    						
    							3. Install the suspension bracket and the flange of fan 
        body to joists by using long screws (ST4.2X20). (If 
        spacing A between joists is 10 1/4~ 12 inches, install 
        the flange of fan body according to Fig.3-2, others 
        according to Fig.3-1 install the product.)
    4. Install the suspension bracket to joists by using long
        screws (ST4.2X20) and secure it to the fan body by
        using screw    (ST4.2X12). (Fig.4)
    5. Remove junction box cover and secure conduit or 
        stress relief to junction box knock-out hole. (Fig.5)
    6. Refer to wiring diagram (page 5).
        Using wire nuts, connect house power wires to
        ventilating fan wires and lighting unit wires:
        black to black; white to white; green to green;
        Replace the junction box cover. (Fig.5)
    CAUTION:
    Mount junction box cover carefully so that lead
    wires are not pinched.
    7. Squeeze the circular duct to fit the adaptor,
        then slipped onto the adaptor and secure
        it with duct tape. 
     nches4 iSqueeze Knock-out hole
    Fig. 5 Fig. 4
    Junction box
    cover Joist
    Duct tape
    Circular duct
    Conduit
    2 Long screws
    (ST4.2X20) Screw
    (ST4.2X12)
    Fig. 3-2
    Joist
    Fan body
    2 Long screws
    (ST4.2X20)Joist
    A=10 1/4
    ~12 inches Wire nut
    Green wires
    Lead wires
    Junction box
    Conduit 4 Long screws (ST4.2X20)
    Fig. 3-1Fan body
    Joist INSTALLATION   (JOIST MOUNTING-  ) CONTINUED
    7 
    						
    							INSTALLATION   (JOIST MOUNTING-  ) CONTINUED8. Finish ceiling work. Ceiling hole should be aligned
        with the edge of the flange. (Fig.6)
    9. Insert the plug connector    and plug connector
        into the receptacle    and receptacle     respectively,
        and secure the lighting unit to the fan unit with 2
        screw     (ST4.2X16) and 1 machine screw (M4X8).
        (Fig.6)
    10. Insert the fluorescent lamp and screw the night
          lamp into the lighting unit. (Fig.6)
    11. Insert mounting springs into slots as shown
          and mount grille to fan body. (Fig.7) INSTALLATION    (JOIST MOUNTING-   ) 
    2. Insert the suspension bracket into the adaptor and
        secure it to joists by using long screws (ST4.2X20).
        (Fig.8) 1. Disconnect plug connector from receptacle and
        remove adaptor from fan body before starting
        installation. 
    CAUTION:
    Backside of fl ange should mount directly to bottom of
    joist.
    If spacing B between joists is 21 1/4 to 23 1/  2
    inches, connect suspension bracket    and 
    (C4 mark to C4 mark) according to page 6.
    Select the suspension bracket according to
    spacing B as shown below.
    3. Follow step 5 to 7 o f the installation   (page 7) to
        complete the duct work and wiring. Spacing B
    between Joists
    inches (mm)
    suspension
    bracket suspension
    bracket
    suspension
    bracketsuspension
    bracket     &
    21 1/  4~ 23 1/  2
       (540 ~597)
    13 1/4~
    15 1/ 2
       (336 ~394) 16 1/
     2~ 18 3/  4
       (419 ~480) Ceiling
    Plug connector Plug connector
    4 W Night Lamp Lighting unit
    Screw
    (ST4.2X16) Plug connector Plug connector
    Machine screw
    (M4X8)
    Fluorescent lamp
    Unit: inches (mm) Receptacle
    Receptacle
    Fig. 6
    Fig. 7
    Mounting spring
    Lighting unit
    Slot
    Ceiling
    Grille
    Adaptor
    Joists
    2 Long screws
    (ST4.2X20)
    2 Long screws
    (ST4.2X20)
    Suspension bracket
    Unit: inches (mm) Adaptor
    13 1/4~
    15 1/ 2(336~ 394)
    16 1/  2~ 18 3/  4(419~ 480)
    21 1/  4~ 23 1/  2(540~ 597)
    B
    Fig. 8
    21  0)
    1 /8(3512 1/ 3058 ( )
    8 
    						
    							INSTALLATION    (JOIST MOUNTING-   ) CONTINUED4. Insert the suspension bracket into fan body (refering
        to step 2 of installation   , page 6).
    5. Insert the fan body into joists. (Fig.9)
    IMPORTANT:Make sure that adaptor claws are properly inserted
    into body slots.
    6. Secure the fan body to adaptor by using machine
        screw and plug connector to receptacle. (Fig.10)
    7. Secure the suspension bracket to joists by using
        long screws (ST4.2X20) and secure it to fan body
        by using screw    (ST4.2X12) in vertical direction.
        (Fig.11)
    8. Follow step 8 to 1 1 of installation   (page 8) to
        complete the installation work.
    When mounting 
    body and blower
    separately
    1. Loosen 4 screws (but
        do not remove them
        from blower). (Fig.12-1)
    2. Remove blower section.
        (Fig.12-2)
    3. Remove adaptor from 
        fan body and secure it 
        to joists as in Fig. 8 of 
        page 8.
    4. Insert fan body 
        (without blower section) 
        into joists. (Fig. 9)
    5. Secure the adaptor to
        fan body by using
        machine screw. (Fig. 10)
    6. Secure the fan body
        to joists by using long
        screws (ST4.2X20).
        (Fig. 11)
    7. Insert the blower into 
        the fan body. (Fig. 12-3)
    8. Secure the blower.
        (Fig. 12-4) and plug
        connector to receptacle.
        (Fig. 10)Adaptor
    4 Screws
    Fig. 12-1
    Fig. 12-2
    Fan body Blower
    Fan body Fig. 12-3
    Fig. 12-4
    4 Screws
    Screw driver Fan body
    Joist
    Conduit
    Junction box cover Circular duct
    Adaptor
    clawsFig. 9Ceiling
    Fig. 10
    Receptacle
    Plug connector
    Machine
    screw
    Screw
    driver Screw    (ST4.2X12)
    2 Long screws
    (ST4.2X20) Joist Fig. 11
    9 
    						
    							INSTALLATION     (  
     - JOIST MOUNTING )  4 kinds of   -joist
       inches (mm) hole
    mark
    C1
    C2
    C3
    C4
    9/16 (14.3)
    1 17/32 (38.9) 11/16 (17.5)
    31/32 (24.6)
    C
    C1
    C3
    C4 C2
    Suspension bracket
    The suspension bracket     can comply with
    different kinds of   -joist.
    1. Before installation, secure the fan body to adaptor by
        using machine screw (M4X8) (Fig.13). Secure the 
        lighting unit to fan body (refering to Fig.6 of page 8).
    2. Connect the suspension bracket     to fan body. (Fig.14)
        (Select the hole by checking   -joist size fix the screw
        to the frame hole.)
    3. Connect the ventilating fan to the   -joist. (Fig.15)
    4. Follow step 5 to 11 of installation   (page 7 ~page 8) to
        complete the installation work. INSTALLATION     ( BETWEEN JOIST MOUNTING )  
    1. Before installation, secure the fan body to adaptor by
        using machine screw (M4X8) (Fig.13). Secure the 
        lighting unit to fan body (refering to Fig.6 of page 8).
    2. Insert the suspension bracket into bracket cover of 
        adaptor side and the back of the fan body. (Fig.16)
        (select the suspension bracket according to spacing 
        A as shown below)
    A
    16 inches and 19.2 inches
    horizontal joist
    19.2 inches vertical joist Fan body
    Machine screw
    (M4X8) Screw
    driver Suspension 
    bracket
    Screw
    (ST4.2X12)
    Fig. 13
    Fig. 14
    Fig. 15
    4 Long screws
    (ST4.2X20)
    joist
    Suspension bracket
    [16 inches and 19.2 inches
    horizontal joist]
    Suspension bracket
    [19.2 inches vertical joist] Suspension bracket
    [16 inches and 19.2 inches
    horizontal joist]
    Suspension bracket
    [19.2 inches vertical joist]
    Suspension bracket
    [16 inches and 19.2 inches
    horizontal joist]
    Suspension bracket
    [19.2 inches vertical joist]
    Fig. 16
    10 
    						
    All Panasonic manuals Comments (0)

    Related Manuals for Panasonic Ventilating Fan Fv-08vsl2, Fv-10vsl2 Installation Instructions