Home > Panasonic > Ventilation > Panasonic Ventilating Fan Fv 05vk1 Installation Instructions

Panasonic Ventilating Fan Fv 05vk1 Installation Instructions

    Download as PDF Print this page Share this page

    Have a look at the manual Panasonic Ventilating Fan Fv 05vk1 Installation Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							Ventilating Fan
    READ AND SAVE THESE INSTRUCTIONS.R
    Please
    readthese
    instructionscarefullybeforeattempting
    toinstall,
    operate or service the Panasonic Ventilating Fan. Failure to comply
    with instructions could result in personal injury and/or property
    damage. Please retain this booklet for future reference.
    FV-05VK1
    FV-08VK1
    Table of Contents
    Description
    Dimensions32
    2
    Supplied Accessories
    Wiring Diagram4
    Specifications
    13
    14 6-84
    54
    Unpacking
    General Safety Information
    12VInstallation( Wooden Header )
    10
    12
    Installation( In Existing Construction )VI
    IInstallation( Joist Mounting- )I
    III( -Joist Mounting )I Installation
    Maintenance
    Practical Guide to Installation
    14Product Service
    11Installation
    ( Between Joist Mounting )IV
    8-10II( Joist Mounting- )II Installation 
    						
    							FV-05VK1
    FV-08VK1
    1 81Thumb screwLong screw
    (M4X30)Quantity Appearance
    Part name
    Suspension
    bracketII1
    1
    Suspension
    bracketIII
    Grille
    Screw
    (M4X10)II2
    2Screw
    (M4X8)I
    These Panasonic ceiling mount ventilating fan models use a sirocco fan with dolphin-shaped blades driven by
    brushless direct current motor. The motor is designed to have long operating life,high dynamic response,higher
    speed ranges with saving energy. Double orifice technology is used to reduce noise. The grille covering the
    main body is a spring-loaded,quickremove type. A damper for preventing counterflow is provided. The double
    orifice technology and the sirocco fan are patented.
    Suspension
    bracketI1
    2 
    						
    							Damper Fan bodyAdaptor
    Grille
    Part name Part name
    No.
    No.
    1
    2
    3
    46
    7
    8
    Suspension bracketOrifice
    Orifice cover Bracket cover
    59
    10Junction box cover
    Junction box
    Unit: ( )inches mmFV-05VK1
    FV-08VK1
    (For 16 inches on center joists, only use suspension bracket , for 19.2 inches on center joists, only use
    suspension bracket , If more than 19.2 inches on center, use suspension bracket & .)I
    III II III
    9 1
    102
    37/8 98()
    7
    3
    13 330()
    10 1/4 261( ) 3 1/2 (90)
    10 1/4 261()
    12 1/8 (307)
    12
    37/8 98()
    7
    3
    6
    13 330()
    10 1/4 261( ) 3 1/2 (90)
    10 1/4 261()
    12 1/8 (307)
    3 1/2 (90)
    5 1/8 130()
    7 7/8 200()
    4
    3 1/4 (81)
    8
    1 (25)
    5
    13/4 45()
    126()
    5 1/8 130()
    7 7/8 200()4
    3 1/4 (81)
    1 (25)
    5
    13/4 45()
    126()
    86
    3 1/2 (90)
    13 1/4~15 1/2 ( 336~394 )
    16 1/2~18 3/4 ( 419~480 )
    21 1/4~23 1/2 ( 540~597 ) 13 1/4~15 1/2 ( 336~394 )
    16 1/2~18 3/4 ( 419~480 )
    21 1/4~23 1/2 ( 540~597 )
    3 
    						
    							Unpack and carefully remove unit from carton.
    Refer to the Supplied Accessories list to verify that all parts are present.
    HzV Air direction Model No.(W)
    Power consumptionSpeed
    (rpm)Air deliver at
    0.1 WG (cfm)Weight
    kg(Ib.)
    Duct
    diameter
    (inches)Noise
    (sone)
    FV-05VK1
    FV-08VK16.0 666 506.0 (13.2)
    						
    							CAUTION:
    1. For general ventilating use only. Do not use to exhaust
    hazardous or explosive materials and vapors.
    2. Not for use in cooking area. (Fig .B)
    3. This product must be properly grounded.
    45o45o
    Floor
    Do not install above or(Cooking area)
    inside this area
    equipmentCooking
    Fig. B
    WARNING:
    To reduce the risk of fire, electric shock or injury to persons, observe the following;
    A. Use this unit only in the manner intended by the manufacturer. If you have any questions, contact
    the manufacturer.
    B. Installation work and electrical wiring must be done by qualified person(s) in accordance with all
    applicable codes and standards, including fire-rated construction.
    C. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney)
    of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturers
    guideline and safety standards such as those published by the National Fire Protection Association
    (NFPA), and the American Society for Heating Refrigeration and Air Conditioning Engineers
    (ASHRAE) and the local code authorities.
    D. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
    E. Ducted fans must always be vented to the outdoors.
    F. These models are UL listed for tub and shower enclosures.
    G. Do not use this unit with any solid-state control device. Solid state controls may cause harmonic distortion
    which can cause motor humming noise.
    H. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting
    means to prevent power from being switched on accidentally. When the service disconnecting means
    cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
    I. NEVER place a switch where it can be reached from a tub or shower.
    J. Not to be installed in a ceiling thermally insulated to a value greater than R40.
    3. Follow all local electrical and safety codes, as well as the National Electrical Code
    (NEC) and the Occupation Safety and Health Act (OSHA).
    4. Always disconnect the power source before working on or near the fan, motor or
    junction box.
    5. Protect the power cord from sharp edges, oil, grease, hot surfaces, chemicals or
    other objects.
    6. Do not kink the power cord.
    7. Do not install the unit where ducts are configured as shown in Fig. A.
    8. Provide suction parts with proper ventilation.
    9. This unit is UL listed for use over a bathtub or shower when installed in a GFCI
    protected branch circuit.Adaptor
    Fig. A
    1. Do not install this ventilating fan where air temperature may exceed 40 C (104 F).oo
    2. Make sure that the electric service supply voltage is 120V, 60 Hz.
    5 
    						
    							1. Before installation, open the orifice cover. Secure the fan
    body to adaptor by using thumb screw. (Fig.1)
    Fig.1
    Fan body
    Thumb screw
    Orifice cover
    Suspension
    bracketI
    Suspension
    bracketIII
    Suspension
    bracketISuspension
    bracketIII
    Suspension
    bracketI
    Fig.2-1
    Fig.2-2
    Fig.2-3
    Fig.2-4Fan body
    Fan body
    Fan body
    Fan body
    Suspension
    bracketI
    Suspension
    bracketIII
    Suspension
    bracketII
    6
    Remove the tape
    IMPORTANT:
    Adaptor
    Remove the tape from damper and adaptor
    before installation.As show below:
    Damper
    2-Screw (M4X8)I
    Suspension bracketIIISuspension bracketII
    If spacing A on center joists is 24 inches, connect
    suspension bracket and (C4 mark to C4 mark)
    as show below :II III
    Press and hold the claw of orifice cover to open
    the orifice cover.
    Orifice cover
    Claw
    2
    1
    2. Insert the supension bracket into the fan body and
    adaptor. (select the suspension bracket as show below)
    Spacing A on center Joists
    Insert Suspension bracket
    Refer to Fig. 2-1
    Refer to Fig. 2-2
    Refer to Fig. 2-3
    Refer to Fig. 2-4 12 inches
    16 inches
    19.2 inches vertical joists
    24 inches
    Joists
    A 
    						
    							Fig.3-2
    Fig.4
    Fan body
    Joist
    4-Long screws(M4X30)
    Joist Fan body
    2-Long screws
    (M4X30)
    2-Long screws
    (M4X30)
    Screw (M4X10)II
    7
    Junction box cover
    Fig. 5
    Conduit or wiring
    Junction box
    Lead wires
    Green wiresWire nut
    ConduitDuct
    5. Remove junction box cover and secure conduit or
    stress relief to junction box knock-out hole. (Fig.5)
    6. Refer to wiring diagram of page 4.
    Using wire nuts, connect house power wires to
    ventilating fan wires:
    black to black; white to white; green to green;
    Replace the junction box cover.
    CAUTION:
    Mount junction box cover carefully so that lead
    wires are not pinched.
    7. Install a circular duct and secure it with duct tape
    or clamps.
    Fig.3-1
    3. Install the suspension bracket and the flange of fan body
    to joists by using long screws (M4X30) ( If spacing A
    between joists is 12 inches, install the flange of fan body
    according to Fig.3-2, others according to Fig.3-1 to install
    the product)
    4. Install the suspension bracket to joists by using long
    screws (M4X30) and secure it to the fan body by
    using screw (M4X10) (Fig.4)II
    Duct tape 
    						
    							2. Insert the suspension bracket into the adaptor and
    secure it to joists by using long screws(M4X30) (Fig.8)
    Keep the distance B (7/8 inch, 21.6mm) for the
    thickness of ceiling board.
    Fig. 6
    8.
    (Fig.6) Finish ceiling work. Ceiling hole should be aligned
    with the edge of the flange.
    9. Insert mounting springs into slots as shown and
    mount grille to fan body. (Fig.7)
    8
    Fig. 8
    1. Open the orifice cover, disconnect plug connector
    from receptacle and remove adaptor from fan body
    before starting installation.
    inches mm()
    Ceiling
    10 7/8(275)
    10 7/8(275)
    If spacing A between joists is 21 1/4 to 23 1/2
    inches (540 to 597mm), connect suspension
    bracket and (C4 mark to C4 mark) according
    to page 8. Select the suspension bracket
    according to spacing A as show below.II III
    suspension
    bracketsuspension
    bracketIsuspension
    bracketIIIsuspension
    bracket &II III Spacing A
    between Joists
    inches (mm)13 1/4~15 1/2
    (336~394)16 1/2~18 3/4
    (419~480)21 1/4~23 1/2
    (540~597)
    2-Long screws(M4X30)Adaptor Joists Adaptor
    2-Long screws
    (M4X30)
    A
    Suspension bracket13 1/4~15 1/2 ( 336~394 )
    16 1/2~18 3/4 ( 419~480 )
    21 1/4~23 1/2 ( 540~597 )
    inches mm()
    Fig. 7
    CeilingSlotMounting spring
    Grille 
    						
    							Make sure that adaptor claws are properly inserted
    into body slots.
    IMPORTANT:
    5. Insert the fan body into joists. (Fig.9)
    6. Open the orifice cover, secure the fan body to
    adaptor by using thumb screw. (Fig.10)
    7. Plug connector to receptacle. (Fig.11)
    When mounting
    body and blower
    separately
    1. Loosen 3 screws (but
    do not remove them
    from blower). (Fig.12-1)
    2. Remove blower section.
    (Fig.12-2)
    4. Insert fan body (without
    blower section) into
    joists. (Fig.9)
    5. Secure the adaptor and
    fan body by using thumb
    screw. (Fig.10) 3. Remove adaptor from
    fan body and secure it
    to joists as in Fig.8 of
    page 8.
    Fig. 11Thumb
    screwPlug connectorReceptacle
    Fig. 10
    Thumb
    screw Orifice cover
    Slots Duct
    Adaptor
    claws
    Fig. 9
    Fan body
    Fig.12-2
    Fan body
    Blower
    Fig.12-3
    Fan body
    Joist
    Fig.12-1
    Adaptor
    3-Screws
    3-Screws
    Fig.12-4
    Screw driver
    Joist
    9
    3. Follow step 5 to 7 of the installation (page 7) to
    complete the duct work and wiring.I
    4. Insert to fan body
    (refering to step 2 of installation , page 6)the suspension bracket in
    I
    7. Insert the blower into the
    fan body. (Fig.12-3) 6. Secure the fan body
    to joists by using long
    screw(M4X30) (Fig.13
    of page 10)
    8. Secure the blower.
    (Fig.12-4) and plug
    connector to receptacle
    (Fig.11)
    Duct tape 
    						
    							CSuspension bracket
    The suspension can comply with
    different kind of -joists.III
    III bracket
    I
    C3
    C4
    C1
    C2
    Fig. 13
    2-Long screws
    (M4X30)Screw (M4X10)II
    10
    Fig.14
    Screw (M4X10)II Suspension
    bracketIII
    Fig.154-Long screws(M4X30)
    I-joist
    9. Follow step 8 to 9 of Installation (page 8) to
    complete the installation work.I
    3. Connect the ventilating fan to the joist. (Fig.15)I-
    2. Connect the suspension to fan body. (Fig.14)
    (Select the hole by checking -joist size and fix the screw
    to the frame hole.)bracketIII
    I 1. Before installation, open the orifice cover. Secure the fan
    body to adaptor by using thumb screw. (Fig.1 of page 6)
    4. Follow step 5 to 9 of installation (page 7~page 8) to
    complete the installation work.I
    8. Secure to joists by using
    long screws(M4X30) and secure it to fan body by
    using screw (M4X10) in vertical direction (Fig.13)the suspension bracket
    II
    C1
    C2
    C3
    C44 kinds of joist
    inches (mm)I-
    9/16 ( )14.3
    11/16 (17.5)
    31/32 (24.6)
    1 17/32 38.9() 
    						
    All Panasonic manuals Comments (0)