Panasonic Ventilating Fan Fv 05vk1 Installation Instructions
Have a look at the manual Panasonic Ventilating Fan Fv 05vk1 Installation Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Ventilating Fan READ AND SAVE THESE INSTRUCTIONS.R Please readthese instructionscarefullybeforeattempting toinstall, operate or service the Panasonic Ventilating Fan. Failure to comply with instructions could result in personal injury and/or property damage. Please retain this booklet for future reference. FV-05VK1 FV-08VK1 Table of Contents Description Dimensions32 2 Supplied Accessories Wiring Diagram4 Specifications 13 14 6-84 54 Unpacking General Safety Information 12VInstallation( Wooden Header ) 10 12 Installation( In Existing Construction )VI IInstallation( Joist Mounting- )I III( -Joist Mounting )I Installation Maintenance Practical Guide to Installation 14Product Service 11Installation ( Between Joist Mounting )IV 8-10II( Joist Mounting- )II Installation
FV-05VK1 FV-08VK1 1 81Thumb screwLong screw (M4X30)Quantity Appearance Part name Suspension bracketII1 1 Suspension bracketIII Grille Screw (M4X10)II2 2Screw (M4X8)I These Panasonic ceiling mount ventilating fan models use a sirocco fan with dolphin-shaped blades driven by brushless direct current motor. The motor is designed to have long operating life,high dynamic response,higher speed ranges with saving energy. Double orifice technology is used to reduce noise. The grille covering the main body is a spring-loaded,quickremove type. A damper for preventing counterflow is provided. The double orifice technology and the sirocco fan are patented. Suspension bracketI1 2
Damper Fan bodyAdaptor Grille Part name Part name No. No. 1 2 3 46 7 8 Suspension bracketOrifice Orifice cover Bracket cover 59 10Junction box cover Junction box Unit: ( )inches mmFV-05VK1 FV-08VK1 (For 16 inches on center joists, only use suspension bracket , for 19.2 inches on center joists, only use suspension bracket , If more than 19.2 inches on center, use suspension bracket & .)I III II III 9 1 102 37/8 98() 7 3 13 330() 10 1/4 261( ) 3 1/2 (90) 10 1/4 261() 12 1/8 (307) 12 37/8 98() 7 3 6 13 330() 10 1/4 261( ) 3 1/2 (90) 10 1/4 261() 12 1/8 (307) 3 1/2 (90) 5 1/8 130() 7 7/8 200() 4 3 1/4 (81) 8 1 (25) 5 13/4 45() 126() 5 1/8 130() 7 7/8 200()4 3 1/4 (81) 1 (25) 5 13/4 45() 126() 86 3 1/2 (90) 13 1/4~15 1/2 ( 336~394 ) 16 1/2~18 3/4 ( 419~480 ) 21 1/4~23 1/2 ( 540~597 ) 13 1/4~15 1/2 ( 336~394 ) 16 1/2~18 3/4 ( 419~480 ) 21 1/4~23 1/2 ( 540~597 ) 3
Unpack and carefully remove unit from carton. Refer to the Supplied Accessories list to verify that all parts are present. HzV Air direction Model No.(W) Power consumptionSpeed (rpm)Air deliver at 0.1 WG (cfm)Weight kg(Ib.) Duct diameter (inches)Noise (sone) FV-05VK1 FV-08VK16.0 666 506.0 (13.2)
CAUTION: 1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. 2. Not for use in cooking area. (Fig .B) 3. This product must be properly grounded. 45o45o Floor Do not install above or(Cooking area) inside this area equipmentCooking Fig. B WARNING: To reduce the risk of fire, electric shock or injury to persons, observe the following; A. Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer. B. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction. C. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturers guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities. D. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. E. Ducted fans must always be vented to the outdoors. F. These models are UL listed for tub and shower enclosures. G. Do not use this unit with any solid-state control device. Solid state controls may cause harmonic distortion which can cause motor humming noise. H. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. I. NEVER place a switch where it can be reached from a tub or shower. J. Not to be installed in a ceiling thermally insulated to a value greater than R40. 3. Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and the Occupation Safety and Health Act (OSHA). 4. Always disconnect the power source before working on or near the fan, motor or junction box. 5. Protect the power cord from sharp edges, oil, grease, hot surfaces, chemicals or other objects. 6. Do not kink the power cord. 7. Do not install the unit where ducts are configured as shown in Fig. A. 8. Provide suction parts with proper ventilation. 9. This unit is UL listed for use over a bathtub or shower when installed in a GFCI protected branch circuit.Adaptor Fig. A 1. Do not install this ventilating fan where air temperature may exceed 40 C (104 F).oo 2. Make sure that the electric service supply voltage is 120V, 60 Hz. 5
1. Before installation, open the orifice cover. Secure the fan body to adaptor by using thumb screw. (Fig.1) Fig.1 Fan body Thumb screw Orifice cover Suspension bracketI Suspension bracketIII Suspension bracketISuspension bracketIII Suspension bracketI Fig.2-1 Fig.2-2 Fig.2-3 Fig.2-4Fan body Fan body Fan body Fan body Suspension bracketI Suspension bracketIII Suspension bracketII 6 Remove the tape IMPORTANT: Adaptor Remove the tape from damper and adaptor before installation.As show below: Damper 2-Screw (M4X8)I Suspension bracketIIISuspension bracketII If spacing A on center joists is 24 inches, connect suspension bracket and (C4 mark to C4 mark) as show below :II III Press and hold the claw of orifice cover to open the orifice cover. Orifice cover Claw 2 1 2. Insert the supension bracket into the fan body and adaptor. (select the suspension bracket as show below) Spacing A on center Joists Insert Suspension bracket Refer to Fig. 2-1 Refer to Fig. 2-2 Refer to Fig. 2-3 Refer to Fig. 2-4 12 inches 16 inches 19.2 inches vertical joists 24 inches Joists A
Fig.3-2 Fig.4 Fan body Joist 4-Long screws(M4X30) Joist Fan body 2-Long screws (M4X30) 2-Long screws (M4X30) Screw (M4X10)II 7 Junction box cover Fig. 5 Conduit or wiring Junction box Lead wires Green wiresWire nut ConduitDuct 5. Remove junction box cover and secure conduit or stress relief to junction box knock-out hole. (Fig.5) 6. Refer to wiring diagram of page 4. Using wire nuts, connect house power wires to ventilating fan wires: black to black; white to white; green to green; Replace the junction box cover. CAUTION: Mount junction box cover carefully so that lead wires are not pinched. 7. Install a circular duct and secure it with duct tape or clamps. Fig.3-1 3. Install the suspension bracket and the flange of fan body to joists by using long screws (M4X30) ( If spacing A between joists is 12 inches, install the flange of fan body according to Fig.3-2, others according to Fig.3-1 to install the product) 4. Install the suspension bracket to joists by using long screws (M4X30) and secure it to the fan body by using screw (M4X10) (Fig.4)II Duct tape
2. Insert the suspension bracket into the adaptor and secure it to joists by using long screws(M4X30) (Fig.8) Keep the distance B (7/8 inch, 21.6mm) for the thickness of ceiling board. Fig. 6 8. (Fig.6) Finish ceiling work. Ceiling hole should be aligned with the edge of the flange. 9. Insert mounting springs into slots as shown and mount grille to fan body. (Fig.7) 8 Fig. 8 1. Open the orifice cover, disconnect plug connector from receptacle and remove adaptor from fan body before starting installation. inches mm() Ceiling 10 7/8(275) 10 7/8(275) If spacing A between joists is 21 1/4 to 23 1/2 inches (540 to 597mm), connect suspension bracket and (C4 mark to C4 mark) according to page 8. Select the suspension bracket according to spacing A as show below.II III suspension bracketsuspension bracketIsuspension bracketIIIsuspension bracket &II III Spacing A between Joists inches (mm)13 1/4~15 1/2 (336~394)16 1/2~18 3/4 (419~480)21 1/4~23 1/2 (540~597) 2-Long screws(M4X30)Adaptor Joists Adaptor 2-Long screws (M4X30) A Suspension bracket13 1/4~15 1/2 ( 336~394 ) 16 1/2~18 3/4 ( 419~480 ) 21 1/4~23 1/2 ( 540~597 ) inches mm() Fig. 7 CeilingSlotMounting spring Grille
Make sure that adaptor claws are properly inserted into body slots. IMPORTANT: 5. Insert the fan body into joists. (Fig.9) 6. Open the orifice cover, secure the fan body to adaptor by using thumb screw. (Fig.10) 7. Plug connector to receptacle. (Fig.11) When mounting body and blower separately 1. Loosen 3 screws (but do not remove them from blower). (Fig.12-1) 2. Remove blower section. (Fig.12-2) 4. Insert fan body (without blower section) into joists. (Fig.9) 5. Secure the adaptor and fan body by using thumb screw. (Fig.10) 3. Remove adaptor from fan body and secure it to joists as in Fig.8 of page 8. Fig. 11Thumb screwPlug connectorReceptacle Fig. 10 Thumb screw Orifice cover Slots Duct Adaptor claws Fig. 9 Fan body Fig.12-2 Fan body Blower Fig.12-3 Fan body Joist Fig.12-1 Adaptor 3-Screws 3-Screws Fig.12-4 Screw driver Joist 9 3. Follow step 5 to 7 of the installation (page 7) to complete the duct work and wiring.I 4. Insert to fan body (refering to step 2 of installation , page 6)the suspension bracket in I 7. Insert the blower into the fan body. (Fig.12-3) 6. Secure the fan body to joists by using long screw(M4X30) (Fig.13 of page 10) 8. Secure the blower. (Fig.12-4) and plug connector to receptacle (Fig.11) Duct tape
CSuspension bracket The suspension can comply with different kind of -joists.III III bracket I C3 C4 C1 C2 Fig. 13 2-Long screws (M4X30)Screw (M4X10)II 10 Fig.14 Screw (M4X10)II Suspension bracketIII Fig.154-Long screws(M4X30) I-joist 9. Follow step 8 to 9 of Installation (page 8) to complete the installation work.I 3. Connect the ventilating fan to the joist. (Fig.15)I- 2. Connect the suspension to fan body. (Fig.14) (Select the hole by checking -joist size and fix the screw to the frame hole.)bracketIII I 1. Before installation, open the orifice cover. Secure the fan body to adaptor by using thumb screw. (Fig.1 of page 6) 4. Follow step 5 to 9 of installation (page 7~page 8) to complete the installation work.I 8. Secure to joists by using long screws(M4X30) and secure it to fan body by using screw (M4X10) in vertical direction (Fig.13)the suspension bracket II C1 C2 C3 C44 kinds of joist inches (mm)I- 9/16 ( )14.3 11/16 (17.5) 31/32 (24.6) 1 17/32 38.9()