    Have a look at the manual Panasonic Upgrade Software Wj Asc960 Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							11
    System Examples
    The following sub-sections provide three sample system architectures to help system engineers setup a WJ-ASC960
    system.
    Single System Domain with Both GX and SX850 Switch Node
    The following system contains one GX switch node and one SX850 switch node. The GX switch node consists of
    two WJ-GXE900 encoders and one WJ-GXD900 decoder. The SX850 switch node contains a WJ-SX850 matrix
    frame box with WJ-PB85X08 (MXCONT), WJ-PB85C16, WJ-PB85M16(MXSW), and WJ-PB85T08(MXOSD) boards.
    There are four video links from WJ-GXD900 decoder to WJ-PB85C16 video inputs. The system also has WV-CU950
    controllers for system or local operators, and a PC station with WJ-ASC960 Admin Console. The system’s WJ-
    MPU955A CPU must have the WJ-ASC960 upgrade software installed in order to perform all of the system func-
    tions. The sample Local database – 01=hybrid850.adm-and sys.ini file – 01A=sys.ini-for Administration Console are
    provided on the CD-ROM. The sample Global database - #=hybrid850.gdm - for Admin is provided on the CD-ROM.
    Also refer to Appendix 1.
    PC with WJ-ASC960
    Admin ConsoleSystem Controller
     (Ethernet)
    POWER
    ON OFF
    SIGNAL
    AUDIO IN VIDEO OUT VIDEO IN 100BASE-TX RS-485TERM1GND2 3ON  OFF4ALARM INTRIGGER OUTRESET4321G4321GGV+
    –G
    Switching HUB
    Switching HUBL3SW L2SW WJ-GXE900
      192.168.1.10
    WJ-HD300A Series
     172.18.0.60
    Digital Disk Recorder 1
    POWER
    ON OFF
    SIGNAL
    AUDIO IN VIDEO OUT VIDEO IN 100BASE-TX RS-485TERM1GND2 3ON  OFF4ALARM INTRIGGER OUTRESET4321G4321GGV+
    –G
    WJ-GXE900
      192.168.1.11
    WJ-GXD900
      192.168.3.11
    WJ-SX850
    WJ-MPU955A (Equipped with WJ-ASC960)
    DO NOT OPEN
    RISK OF ELECTRIC SHOCK. 
    SIGNAL
    GND
    SIGNAL
    GND
    RS-232C
    CAUTION
    ATTENTIONNE PAS OUVRIR
    RISQUE DE CHOCS 
    ELECTROUES
    VS / VD
    IN
    OUT
      VD    OUT
      ETHERNET
    AC IN
    1234567
    8CAMERA IN
    VIDEO OUT
    CAMERA1234567
    8
    IN/OUT
    IN/OUT
    THRU1234567
    8MONITOR OUT
    VIDEO IN
    OSD
    1
    2VIDEO IN
    1
    2VIDEO OUT
    OUTPUT
    1
    2VIDEO IN
    1
    2VIDEO OUT
    INPUT
    SIGNAL GND
    POWERONOFF3 3 1
    4 21
    42
    VIDEO OUT AUDIO OUT MIX
    RESET1000BASE-T
    100BASE-TXV+–GQUAD
    192.168.1.1
    192.168.3.1192.168.200.1
    192.168.3.11
    172.18.0.1
    192.168.200.200
    10BASE-T/100BASE-TX
    SERIAL
    21 OTHER SYSTEM
    DEVICE SYSTEM
    CONTROLLERPOWER
    ON
    AC IN OFFSIGNAL GND
    Cam9
    Cam1
    Cam2
    Cam5
    Cam6
    Cam7
    Cam8
    CPUCam3
    Cam4 Cam 13Cam10
    Cam11
    Cam14
    Cam15
    Cam16
    Mon1
    Mon2
    Mon3
    Mon4Cam12Encoder 1
    Encoder 2
    Decoder 1
    1 182IN
    OUTCASCADE
    OUT
    16 16
    3
    15
    15
    1414132
    1
    13
    1212
    1111
    1010
    99
    88
    77
    66
    55
    44
    33
    22
    11
    VIDEOAUDIO IN AUDIO OUTMONITOR OUT CASCADE INMONITOR (VGA) ALARM/CONTROLSERIALALARM
    POWER COPY 1 MODEEXT STORAGE 10/100BASE-T RS485(CAMERA)DATAAC  IN
    SIGNAL GND142 
    						
    							12
    Encoder WJ-GXE900 Setup
    •Refer to WJ-GXE900 Operational Manual to set following configuration through the Web browser.
    Encoder # Operation Mode IP Address Subnet Mask Default Gateway DNS Rotary Switch
    1 Main CPU mode 192.168.1.10 255.255.255.0 192.168.1.1 0.0.0.0 0-0-1
    2 Main CPU mode 192.168.1.11 255.255.255.0 192.168.1.1 0.0.0.0 0-0-2
    Decoder WJ-GXD900 Setup
    •Refer to WJ-GXD900 Operational Manual to set following configuration through the Web browser.
    Decoder # Operation Mode IP Address Subnet Mask Default Gateway DNS Rotary Switch
    1 Main CPU mode 192.168.3.11 255.255.255.0 192.168.3.1 0.0.0.0 0-1-0
    Note:The rotary dip-switch valued should not be same as Encoder’s one.
    L3SW Setup
    •Set the following IP Address to each port.
    Port # IP Address Connection
    1 192.168.1.1 Encoder #1,2
    2 192.168.3.1 Decoder #1
    3 192.168.200.1 MPU955A
    •Valid the IGMP V2 due to support Multicast messages.
    Card Cage WJ-SX850 Setup
    •Refer to WJ-SX850 Operational Manual to set following configuration.
    Slot # Board name/model # Rotary Switch Qty
    –LCPU 0-2-0 Included
    1 WJ-PB85X08 0-0 1
    2 WJ-PB85Y08–1
    15 WJ-PB85C16 0-0 1
    16 WJ-PB85T08 0-0 1
    17 WJ-PB85M16 0-0 1
    –WJ-CA85L05(Multiple Video cable)–3
    Digital Disk Recorder HD300A Series Setup
    Digital Disk Recorder# Line Speed HTTP Port Number DHCP IP Address
    1 AUTO 00080 OFF 172.018.000.060
    Subnet Mask Gateway Unit Address (System) Unit Address (Controller)
    255.255.000.000 000.000.000.000 001 001 
    						
    							13
    Single System Domain with Both GX and SX650 Switch Node
    The following system contains one GX switch node and one SX650 switch node. GX switch node consists of two
    WJ-GXE900 encoders and one WJ-GXD900 decoder. SX650 switch node contains a WJ-SX650 matrix switcher
    input, output and a WJ-PB65E01 network board. There are four video links from WJ-GXD900 decoder to WJ-SX650
    input board. The system also has WV-CU950 controllers for system or local operators, and a PC station with WJ-
    ASC960 Admin Console. The system’s WJ-MPU955A CPU must have the WJ-ASC960 upgrade software installed in
    order to perform all of the system functions. The sample Local database – 01=hybrid650.adm-and sys.ini file –
    01A=sys.ini-for Administration Console are provided on the CD-ROM. The sample Global database -
    #=hybrid650.gdm - for Admin is provided on the CD-ROM. Also refer to Appendix 3.
    PC with WJ-ASC960
    Admin ConsoleSystem Controller
     (Ethernet)
    POWER
    ON OFF
    SIGNAL
    AUDIO IN VIDEO OUT VIDEO IN 100BASE-TX RS-485TERM1GND2 3ON  OFF4ALARM INTRIGGER OUTRESET4321G4321GGV+
    –G
    Switching HUB
    Switching HUB WJ-SX650L3SW
    L2SW WJ-GXE900
      192.168.1.10
    WJ-HD300A Series
     172.18.0.60
    Digital Disk Recorder 1
    POWER
    ON OFF
    SIGNAL
    AUDIO IN VIDEO OUT VIDEO IN 100BASE-TX RS-485TERM1GND2 3ON  OFF4ALARM INTRIGGER OUTRESET4321G4321GGV+
    –G
    WJ-GXE900
      192.168.1.11
    WJ-GXD900
      192.168.3.11
    WJ-SX850
    SIGNAL GND
    POWERONOFF3 3 1
    4 21
    42
    VIDEO OUT AUDIO OUT MIX
    RESET1000BASE-T
    100BASE-TXV+–GQUAD
    192.168.1.1
    192.168.3.1192.168.200.1
    192.168.3.11
    172.18.0.1192.168.200.200
    10BASE-T/100BASE-TX
    SERIAL
    21 OTHER SYSTEM
    DEVICE SYSTEM
    CONTROLLERPOWER
    ON
    AC IN OFFSIGNAL GND
    3C
    1 2B
    1 2 3AC IN3
    2
    1A
    SIGNAL GND
    SIGNAL GND
    ON4-LineRS485(CAMERA) SET UPMODE
    ON4-LineMODE
    VIDEO OUT 3
    VIDEO OUT 4
    VIDEO OUT 2IN X-2VIDEO OUT 1ALARM INEXTENSION  3  INEXTENSION  2  IN4MODERS485 (CAMERA) RS485 (CAMERA)3MODE MODE MODE21IN C-3
    MODE MODE MODE MODEDATADATAEXTENSION 1TERM.OFF
    ON
    OUTINOUT X-31 2 3 4TERM.ON
    ON
    MODETERM.OFFMODEDATA 4
    HDR4/TMNL8
    HDR2/TMNL4DATA 3
    HDR3/TMNL7
    HDR1/TMNL3DATA 2
    TMNL6
    TMNL2DATA 1
    TMNL5TMNL1/PS DATAVideo Output Board 2Video Output Board 1OUT X-21 2 3 4 5 6 7 8MONITOR OUT9 10 11 12 13 14 1516
    IN X-116 15 14 13 12 11 10 9CAMERA IN87654321
    32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17
    NETWORK OUT X-1ALARM OUT 2
    ALARM OUT 1SERIALVS OUTVS INVS OUT
    (THRU)Video Output Board 1 Only10/100 BASE-T
    1 182IN
    OUTCASCADE
    OUT
    16 16
    3
    15
    15
    1414132
    1
    13
    1212
    1111
    1010
    99
    88
    77
    66
    55
    44
    33
    22
    11
    VIDEOAUDIO IN AUDIO OUTMONITOR OUT CASCADE INMONITOR (VGA) ALARM/CONTROLSERIALALARM
    POWER COPY 1 MODEEXT STORAGE 10/100BASE-T RS485(CAMERA)DATAAC  IN
    SIGNAL GND142
    WJ-MPU955A (Equipped with WJ-ASC960)
    Cam9
    Cam4
    Cam3
    Cam5
    Cam6
    Cam7
    Cam8Cam2
    Cam1 Cam 13Cam10
    Cam11
    Cam14
    Cam15
    Cam16
    Mon1
    Mon2
    Mon3
    Mon4Cam12Encoder 1
    Encoder 2
    Decoder 1 
    						
    							14
    Encoder WJ-GXE900 Setup
    Same as System850 description
    Decoder WJ-GXD900 Setup
    Same as System850 description
    L3SW Setup
    Same as System850 description
    WJ-SX650 Setup
    Slot # Board name Rotary Switch/Mode Qty
    C Video Input Board 0 1
    B
    A Video Output Board with Network Board Output Board (1) 1
    Digital Disk Recorder HD300A Series Setup
    Same as System850 description 
    						
    							PC with WJ-ASC960
    Admin ConsoleSystem Controller
     (Ethernet)System Controller
     (Ethernet)
    POWER
    ON OFF
    SIGNALAUDIO IN VIDEO OUT VIDEO IN 100BASE-TX RS-485TERM1GND2 3ON  OFF4ALARM INTRIGGER OUTRESET4321G4321GGV+
    –G
    Encoder 1-1
    Encoder 1-2
    Decoder 1-1 Decoder 2-1
    Switching HUBSwitching HUB L3SW-1L2SW
    WJ-GXE900
    192.168.1.10
    POWER
    ON OFF
    SIGNALAUDIO IN VIDEO OUT VIDEO IN 100BASE-TX RS-485TERM1GND2 3ON  OFF4ALARM INTRIGGER OUTRESET4321G4321GGV+
    –G
    WJ-GXE900
      192.168.1.11
    WJ-GXD900
      192.168.2.10
    WJ-MPU955A
    Equipped with WJ-ASC960
    SIGNAL GND
    POWERONOFF3 3 1
    4 21
    42
    VIDEO OUT AUDIO OUT MIX
    RESET1000BASE-T
    100BASE-TXV+–GQUAD
    PC with WJ-ASC960
    Admin Console
    Switching 
    HUB
    192.168.1.1
    Switching HUBL3SW-2
    WJ-GXD900
      192.168.4.10WJ-MPU955A
    Equipped with WJ-ASC960
    SIGNAL GND
    POWERONOFF3 3 1
    4 21
    42
    VIDEO OUT AUDIO OUT MIX
    RESET1000BASE-T
    100BASE-TXV+–GQUAD
    192.168.4.1
    192.168.201.1
    192.168.201.200 192.168.200.1
    192.168.200.200
    172.16.192.1
    172.18.0.1172.16.192.2
    172.18.0.1192.168.2.1192.168.5.1
    CPU-1
    CPU-2
    POWER
    ON OFF
    SIGNALAUDIO IN VIDEO OUT VIDEO IN 100BASE-TX RS-485TERM1GND2 3ON  OFF4ALARM INTRIGGER OUTRESET4321G4321GGV+
    –G
    Encoder 2-1
    Encoder 2-2L2SWWJ-GXE900
      192.168.3.10
    POWER
    ON OFF
    SIGNALAUDIO IN VIDEO OUT VIDEO IN 100BASE-TX RS-485TERM1GND2 3ON  OFF4ALARM INTRIGGER OUTRESET4321G4321GGV+
    –G
    WJ-GXE900
      192.168.3.11
    Switching 
    HUB
    192.168.3.1
    192.168.5.2
    Cam1-1Cam1-2
    Cam1-4
    Cam1-3
    Cam1-5
    Cam1-6
    Cam1-7
    Mon1-1 Mon1-2 Mon1-3 Mon1-4 Mon2-1 Mon2-2 Mon2-3 Mon2-4
    Domain 1
    1 182IN
    OUTCASCADE
    OUT
    16 16
    3
    15
    15
    1414132
    1
    13
    1212
    1111
    1010
    99
    88
    77
    66
    55
    44
    33
    22
    11
    VIDEOAUDIO IN AUDIO OUTMONITOR OUT CASCADE INMONITOR (VGA) ALARM/CONTROLSERIALALARM
    POWER COPY 1 MODEEXT STORAGE 10/100BASE-T RS485(CAMERA)DATAAC  IN
    SIGNAL GND142WJ-HD300A 
    Series
     172.18.0.60 Digital Disk 
    Recorder 1-1
    Digital Disk Recorder 2-1
    Cam2-1Cam2-2
    Cam2-4
    Cam2-3
    Cam2-5
    Cam2-6Cam2-7
    Domain 2
    1 182IN
    OUTCASCADE
    OUT
    16 16
    3
    15
    15
    1414132
    1
    13
    1212
    1111
    1010
    99
    88
    77
    66
    55
    44
    33
    22
    11
    VIDEOAUDIO IN AUDIO OUTMONITOR OUT CASCADE INMONITOR (VGA) ALARM/CONTROLSERIALALARM
    POWER COPY 1 MODEEXT STORAGE 10/100BASE-T RS485(CAMERA)DATAAC  IN
    SIGNAL GND142WJ-HD300A Series
     172.18.0.60
    10BASE-T/100BASE-TX
    SERIAL
    21 OTHER SYSTEM
    DEVICE SYSTEM
    CONTROLLERPOWER
    ON
    AC IN OFFSIGNAL GND10BASE-T/100BASE-TX
    SERIAL
    21 OTHER SYSTEM
    DEVICE SYSTEM
    CONTROLLERPOWER
    ON
    AC IN OFFSIGNAL GND
    15
    Multiple System Domains with Single GX Switch Node
    The following system includes two system domains. Each system domain has its own GX switch node. The system
    domain has two WJ-GXE900 encoders and one WJ-GXD900 decoder. It contains a domain WJ-MPU955A CPU with
    the WJ-ASC960 upgrade software installed. Within the domain, a PC with WJ-ASC960 Admin Console software
    installed is required to configure resources and operations within the domain. The two system domains can work
    independently as standalone systems. The sample Local database – 01=multi_1.adm, 02=multi_2.adm -and sys.ini
    file – 01A=sys.ini, 02A=sys.ini -for Administration Console are provided on the CD-ROM. The sample Global data-
    base - #=multi.gdm - for Admin is provided on the CD-ROM. Also refer to Appendix 2. 
    						
    							16
    Encoder WJ-GXE900 Setup
    •Refer to WJ-GXE900 Operational Manual to set following configuration through the Web browser.
    Encoder # Operation Mode IP Address Subnet Mask Default Gateway DNS Rotary Switch
    1-1 Main CPU mode 192.168.1.10 255.255.255.0 192.168.1.1 0.0.0.0 0-0-1
    1-2 Main CPU mode 192.168.1.11 255.255.255.0 192.168.1.1 0.0.0.0 0-0-2
    2-1 Main CPU mode 192.168.3.10 255.255.255.0 192.168.3.1 0.0.0.0 0-0-3
    2-2 Main CPU mode 192.168.3.11 255.255.255.0 192.168.3.1 0.0.0.0 0-0-4
    Encoder # MULTICAST IP ADDRESS FOR SETUP
    in System Setup page
    1-1 239.192.255.2(default)
    1-2 239.192.255.2(default)
    2-1 239.192.255.3
    2-2 239.192.255.3
    Decoder WJ-GXD900 Setup
    •Refer to WJ-GXD900 Operational Manual to set following configuration through the Web browser.
    Decoder # Operation Mode IP Address Subnet Mask Default Gateway DNS Rotary Switch
    1-1 Main CPU mode 192.168.2.10 255.255.255.0 192.168.2.1 0.0.0.0 0-1-0
    2-1 Main CPU mode 192.168.4.10 255.255.255.0 192.168.4.1 0.0.0.0 0-1-1
    Decoder # MULTICAST IP ADDRESS FOR SETUP
    in System Setup page
    1-1 239.192.255.2(default)
    2-1 239.192.255.3
    Note:The rotary dip-switch valued should not be same as Encoder’s one.
    L3SW-1 Setup
    •Set the following IP Address to each port.
    Port # IP Address Connection
    1 192.168.1.1 Encoder #1-1,1-2
    2 192.168.2.1 Decoder #1-1
    3 192.168.5.1 Link to L3SW-2
    4 192.168.200.1 CPU-1
    •Valid the IGMP V2 due to support Multicast messages. 
    						
    							17
    L3SW-2 Setup
    •Set the following IP Address to each port.
    Port # IP Address Connection
    1 192.168.3.1 Encoder #2-1, 2-2
    2 192.168.4.1 Decoder #2-1
    3 192.168.5.2 Link to L3SW-1
    4 192.168.201.1 CPU-2
    •Valid the IGMP V2 due to support Multicast messages.
    Digital Disk Recorder HD300A Series Setup
    Digital Disk Recorder# Line Speed HTTP Port Number DHCP IP Address
    1-1 AUTO 00080 OFF 172.018.000.060
    2-1 AUTO 00080 OFF 172.018.000.060
    Subnet Mask Gateway Unit Address (System) Unit Address (Controller)
    255.255.000.000 000.000.000.000 001 001
    255.255.000.000 000.000.000.000 001 001 
    						
    							18
    Multiple System Domains with Single SX650 Switch Node
    The following system includes two system domains. Each system domain has its own SX650 switch node. The sys-
    tem domain has two WJ-SX650 matrix switchers. It contains a domain WJ-MPU955A CPU with the WJ-ASC960
    upgrade software installed. Within the domain, a PC with WJ-ASC960 Admin Console software installed is required
    to configure resources and operations within the domain. The two system domains can work independently as
    standalone systems. The sample Local database – 01=multi650_1.adm, 02=multi650_2.adm -and sys.ini file –
    01A=sys.ini, 02A=sys.ini -for Administration Console are provided on the CD-ROM. The sample Global database -
    #=multi650.gdm - for Admin is provided on the CD-ROM. Also refer to Appendix 4.
    Cam1-1
    Cam1-4Cam1-2
    Cam1-7 Cam1-3
    Cam1-5
    Cam1-6
    Cam1-8Cam2-1
    Cam2-4Cam2-2
    Cam2-7 Cam2-3
    Cam2-5
    Cam2-6
    Cam2-8
    3C
    1 2B
    1 2 3AC IN3
    2
    1A
    SIGNAL GND
    SIGNAL GND
    ON4-LineRS485(CAMERA) SET UPMODEON4-LineMODE
    VIDEO OUT 3
    VIDEO OUT 4
    VIDEO OUT 2IN X-2VIDEO OUT 1ALARM INEXTENSION  3  INEXTENSION  2  IN4MODERS485 (CAMERA) RS485 (CAMERA)3MODE MODE MODE21IN C-3
    MODE MODE MODE MODEDATADATAEXTENSION 1TERM.OFF
    ON
    OUTINOUT X-31 2 3 4TERM.ON
    ON
    MODETERM.OFF
    MODEDATA 4
    HDR4/TMNL8
    HDR2/TMNL4DATA 3
    HDR3/TMNL7
    HDR1/TMNL3DATA 2
    TMNL6
    TMNL2DATA 1
    TMNL5TMNL1/PS DATAVideo Output Board 2
    Video Output Board 1OUT X-21 2 3 4 5 6 7 8MONITOR OUT9 10 11 12 13 14 1516
    IN X-116 15 14 13 12 11 10 9CAMERA IN8765432132 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17
    NETWORK OUT X-1ALARM OUT 2
    ALARM OUT 1SERIALVS OUTVS INVS OUT
    (THRU)Video Output Board 1 Only10/100 BASE-T
    Mon1
    Mon2
    Mon3
    Mon4 WJ-HD300A Series
    WJ-SX650 WJ-SX650
    1 18
    2IN
    OUTCASCADE
    OUT
    16 16 315 1514
    1413
    2 11312 1211
    1110
    109
    98
    87
    76
    65
    54
    43
    32
    21
    1VIDEO
    AUDIO IN AUDIO OUTMONITOR OUT CASCADE INMONITOR (VGA) ALARM/CONTROLSERIAL ALARMPOWER COPY 1 MODEEXT STORAGE 10/100BASE-T RS485(CAMERA)D ATAAC  IN
    SIGNAL GND142
    3C
    1 2B
    1 2 3AC IN3
    2
    1A
    SIGNAL GND
    SIGNAL GND
    ON4-LineRS485(CAMERA) SET UPMODEON4-LineMODE
    VIDEO OUT 3
    VIDEO OUT 4
    VIDEO OUT 2IN X-2VIDEO OUT 1ALARM INEXTENSION  3  INEXTENSION  2  IN4MODERS485 (CAMERA) RS485 (CAMERA)3MODE MODE MODE21IN C-3
    MODE MODE MODE MODEDATADATAEXTENSION 1TERM.OFF
    ON
    OUTINOUT X-31 2 3 4TERM.ON
    ON
    MODETERM.OFF
    MODEDATA 4
    HDR4/TMNL8
    HDR2/TMNL4DATA 3
    HDR3/TMNL7
    HDR1/TMNL3DATA 2
    TMNL6
    TMNL2DATA 1
    TMNL5TMNL1/PS DATAVideo Output Board 2
    Video Output Board 1OUT X-21 2 3 4 5 6 7 8MONITOR OUT9 10 11 12 13 14 1516
    IN X-116 15 14 13 12 11 10 9CAMERA IN8765432132 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17
    NETWORK OUT X-1ALARM OUT 2
    ALARM OUT 1SERIALVS OUTVS INVS OUT
    (THRU)Video Output Board 1 Only10/100 BASE-T
    Mon1
    Mon2
    Mon3
    Mon4 WJ-HD300A Series
    1 18
    2IN
    OUTCASCADE
    OUT
    16 16 315 1514
    1413
    2 11312 1211
    1110
    109
    98
    87
    76
    65
    54
    43
    32
    21
    1VIDEO
    AUDIO IN AUDIO OUTMONITOR OUT CASCADE INMONITOR (VGA) ALARM/CONTROLSERIAL ALARMPOWER COPY 1 MODEEXT STORAGE 10/100BASE-T RS485(CAMERA)D ATAAC  IN
    SIGNAL GND142
    PC with WJ-ASC960
    Admin ConsoleSystem Controller
     (Ethernet)
    Switching HUBSwitching HUB
    Switching
    HUBSwitching HUBSwitching HUB
    10BASE-T/100BASE-TX
    SERIAL
    21 OTHER SYSTEM
    DEVICE SYSTEM
    CONTROLLERPOWER
    ON
    AC IN OFFSIGNAL GND
    WJ-MPU955A
    (Equipped with WJ-ASC960)WJ-MPU955A
    (Equipped with WJ-ASC960)
    PC with WJ-ASC960
    Admin ConsoleSystem Controller
     (Ethernet)
    10BASE-T/100BASE-TX
    SERIAL
    21 OTHER SYSTEM
    DEVICE SYSTEM
    CONTROLLERPOWER
    ON
    AC IN OFFSIGNAL GND172.18.0.1 172.16.192.2
    172.18.0.1192.168.200.200192.168.200.200
    172.16.192.1
    Domain 1Domain 2 
    						
    							19
    WJ-SX650 Setup
    Slot # Board name Rotary Switch/Mode Qty
    C Video Input Board 0 1
    B
    A Video Output Board with Network Board Output Board (1) 1
    Digital Disk Recorder HD300A Series Setup
    Same as Single System Domain with Both GX and SX850 Switch Node on page 12 
    						
    							20
    System Setup
    Define a System Domain
    Number of System Domains
    By definition, each system domain must have a WJ-MPU955A CPU. If it is a redundant system, it must have two
    WJ-MPU955A CPUs. The system can consist of up to 64 system domains.
    Domain and Unit ID Assignments
    For each CPU, you must assign a Unit ID. Once a Unit ID is assigned, the system will refer to its Domain ID equal to
    this Unit ID.
    Enter Unit ID in the WJ-ASC960 Admin Console
    In the WJ-ASC960 Admin Console main screen, select CPU Unitson the Domainmenu. TheCPU System
    Configuration screen will be activated.
    Then, enter the Unit(s)information into the fields provided. In the following
    table, we used the example on page 15 to show what information you would need to enter.
    Unit ID Main IPA [A] Backup IPA [B] Unit Name Size
    1 172.16.192.1–Domain 1 Enhanced
    2 172.16.192.2–Domain 2 Enhanced
    Enter Unit ID in the System Configuration File
    In each WJ-MPU955A CPU, there is a system configuration file named SYS.INI. You can view and edit the file
    through WJ-ASC960 Admin Console. For each new system domain that is set up, you need to enter the correct ID in
    the [UNIT] section of the SYS.INI file. The following is the text from the SYS.INI files [UNIT] section.
    [UNIT]
    ***{ The unit ID should be the same as the one defined in }
    ***{   the Global Admin database for this unit. }
    ***{ For single-unit systems, use ID=1.  (ID=0 is invalid) }
    ID=1 
    						