11 System Examples The following sub-sections provide three sample system architectures to help system engineers setup a WJ-ASC960 system. Single System Domain with Both GX and SX850 Switch Node The following system contains one GX switch node and one SX850 switch node. The GX switch node consists of two WJ-GXE900 encoders and one WJ-GXD900 decoder. The SX850 switch node contains a WJ-SX850 matrix frame box with WJ-PB85X08 (MXCONT), WJ-PB85C16, WJ-PB85M16(MXSW), and WJ-PB85T08(MXOSD) boards. There are four video links from WJ-GXD900 decoder to WJ-PB85C16 video inputs. The system also has WV-CU950 controllers for system or local operators, and a PC station with WJ-ASC960 Admin Console. The system’s WJ- MPU955A CPU must have the WJ-ASC960 upgrade software installed in order to perform all of the system func- tions. The sample Local database – 01=hybrid850.adm-and sys.ini file – 01A=sys.ini-for Administration Console are provided on the CD-ROM. The sample Global database - #=hybrid850.gdm - for Admin is provided on the CD-ROM. Also refer to Appendix 1. PC with WJ-ASC960 Admin ConsoleSystem Controller (Ethernet) POWER ON OFF SIGNAL AUDIO IN VIDEO OUT VIDEO IN 100BASE-TX RS-485TERM1GND2 3ON OFF4ALARM INTRIGGER OUTRESET4321G4321GGV+ –G Switching HUB Switching HUBL3SW L2SW WJ-GXE900 192.168.1.10 WJ-HD300A Series 172.18.0.60 Digital Disk Recorder 1 POWER ON OFF SIGNAL AUDIO IN VIDEO OUT VIDEO IN 100BASE-TX RS-485TERM1GND2 3ON OFF4ALARM INTRIGGER OUTRESET4321G4321GGV+ –G WJ-GXE900 192.168.1.11 WJ-GXD900 192.168.3.11 WJ-SX850 WJ-MPU955A (Equipped with WJ-ASC960) DO NOT OPEN RISK OF ELECTRIC SHOCK. SIGNAL GND SIGNAL GND RS-232C CAUTION ATTENTIONNE PAS OUVRIR RISQUE DE CHOCS ELECTROUES VS / VD IN OUT VD OUT ETHERNET AC IN 1234567 8CAMERA IN VIDEO OUT CAMERA1234567 8 IN/OUT IN/OUT THRU1234567 8MONITOR OUT VIDEO IN OSD 1 2VIDEO IN 1 2VIDEO OUT OUTPUT 1 2VIDEO IN 1 2VIDEO OUT INPUT SIGNAL GND POWERONOFF3 3 1 4 21 42 VIDEO OUT AUDIO OUT MIX RESET1000BASE-T 100BASE-TXV+–GQUAD 192.168.1.1 192.168.3.1192.168.200.1 192.168.3.11 172.18.0.1 192.168.200.200 10BASE-T/100BASE-TX SERIAL 21 OTHER SYSTEM DEVICE SYSTEM CONTROLLERPOWER ON AC IN OFFSIGNAL GND Cam9 Cam1 Cam2 Cam5 Cam6 Cam7 Cam8 CPUCam3 Cam4 Cam 13Cam10 Cam11 Cam14 Cam15 Cam16 Mon1 Mon2 Mon3 Mon4Cam12Encoder 1 Encoder 2 Decoder 1 1 182IN OUTCASCADE OUT 16 16 3 15 15 1414132 1 13 1212 1111 1010 99 88 77 66 55 44 33 22 11 VIDEOAUDIO IN AUDIO OUTMONITOR OUT CASCADE INMONITOR (VGA) ALARM/CONTROLSERIALALARM POWER COPY 1 MODEEXT STORAGE 10/100BASE-T RS485(CAMERA)DATAAC IN SIGNAL GND142
12 Encoder WJ-GXE900 Setup •Refer to WJ-GXE900 Operational Manual to set following configuration through the Web browser. Encoder # Operation Mode IP Address Subnet Mask Default Gateway DNS Rotary Switch 1 Main CPU mode 192.168.1.10 255.255.255.0 192.168.1.1 0.0.0.0 0-0-1 2 Main CPU mode 192.168.1.11 255.255.255.0 192.168.1.1 0.0.0.0 0-0-2 Decoder WJ-GXD900 Setup •Refer to WJ-GXD900 Operational Manual to set following configuration through the Web browser. Decoder # Operation Mode IP Address Subnet Mask Default Gateway DNS Rotary Switch 1 Main CPU mode 192.168.3.11 255.255.255.0 192.168.3.1 0.0.0.0 0-1-0 Note:The rotary dip-switch valued should not be same as Encoder’s one. L3SW Setup •Set the following IP Address to each port. Port # IP Address Connection 1 192.168.1.1 Encoder #1,2 2 192.168.3.1 Decoder #1 3 192.168.200.1 MPU955A •Valid the IGMP V2 due to support Multicast messages. Card Cage WJ-SX850 Setup •Refer to WJ-SX850 Operational Manual to set following configuration. Slot # Board name/model # Rotary Switch Qty –LCPU 0-2-0 Included 1 WJ-PB85X08 0-0 1 2 WJ-PB85Y08–1 15 WJ-PB85C16 0-0 1 16 WJ-PB85T08 0-0 1 17 WJ-PB85M16 0-0 1 –WJ-CA85L05(Multiple Video cable)–3 Digital Disk Recorder HD300A Series Setup Digital Disk Recorder# Line Speed HTTP Port Number DHCP IP Address 1 AUTO 00080 OFF 172.018.000.060 Subnet Mask Gateway Unit Address (System) Unit Address (Controller) 255.255.000.000 000.000.000.000 001 001
13 Single System Domain with Both GX and SX650 Switch Node The following system contains one GX switch node and one SX650 switch node. GX switch node consists of two WJ-GXE900 encoders and one WJ-GXD900 decoder. SX650 switch node contains a WJ-SX650 matrix switcher input, output and a WJ-PB65E01 network board. There are four video links from WJ-GXD900 decoder to WJ-SX650 input board. The system also has WV-CU950 controllers for system or local operators, and a PC station with WJ- ASC960 Admin Console. The system’s WJ-MPU955A CPU must have the WJ-ASC960 upgrade software installed in order to perform all of the system functions. The sample Local database – 01=hybrid650.adm-and sys.ini file – 01A=sys.ini-for Administration Console are provided on the CD-ROM. The sample Global database - #=hybrid650.gdm - for Admin is provided on the CD-ROM. Also refer to Appendix 3. PC with WJ-ASC960 Admin ConsoleSystem Controller (Ethernet) POWER ON OFF SIGNAL AUDIO IN VIDEO OUT VIDEO IN 100BASE-TX RS-485TERM1GND2 3ON OFF4ALARM INTRIGGER OUTRESET4321G4321GGV+ –G Switching HUB Switching HUB WJ-SX650L3SW L2SW WJ-GXE900 192.168.1.10 WJ-HD300A Series 172.18.0.60 Digital Disk Recorder 1 POWER ON OFF SIGNAL AUDIO IN VIDEO OUT VIDEO IN 100BASE-TX RS-485TERM1GND2 3ON OFF4ALARM INTRIGGER OUTRESET4321G4321GGV+ –G WJ-GXE900 192.168.1.11 WJ-GXD900 192.168.3.11 WJ-SX850 SIGNAL GND POWERONOFF3 3 1 4 21 42 VIDEO OUT AUDIO OUT MIX RESET1000BASE-T 100BASE-TXV+–GQUAD 192.168.1.1 192.168.3.1192.168.200.1 192.168.3.11 172.18.0.1192.168.200.200 10BASE-T/100BASE-TX SERIAL 21 OTHER SYSTEM DEVICE SYSTEM CONTROLLERPOWER ON AC IN OFFSIGNAL GND 3C 1 2B 1 2 3AC IN3 2 1A SIGNAL GND SIGNAL GND ON4-LineRS485(CAMERA) SET UPMODE ON4-LineMODE VIDEO OUT 3 VIDEO OUT 4 VIDEO OUT 2IN X-2VIDEO OUT 1ALARM INEXTENSION 3 INEXTENSION 2 IN4MODERS485 (CAMERA) RS485 (CAMERA)3MODE MODE MODE21IN C-3 MODE MODE MODE MODEDATADATAEXTENSION 1TERM.OFF ON OUTINOUT X-31 2 3 4TERM.ON ON MODETERM.OFFMODEDATA 4 HDR4/TMNL8 HDR2/TMNL4DATA 3 HDR3/TMNL7 HDR1/TMNL3DATA 2 TMNL6 TMNL2DATA 1 TMNL5TMNL1/PS DATAVideo Output Board 2Video Output Board 1OUT X-21 2 3 4 5 6 7 8MONITOR OUT9 10 11 12 13 14 1516 IN X-116 15 14 13 12 11 10 9CAMERA IN87654321 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 NETWORK OUT X-1ALARM OUT 2 ALARM OUT 1SERIALVS OUTVS INVS OUT (THRU)Video Output Board 1 Only10/100 BASE-T 1 182IN OUTCASCADE OUT 16 16 3 15 15 1414132 1 13 1212 1111 1010 99 88 77 66 55 44 33 22 11 VIDEOAUDIO IN AUDIO OUTMONITOR OUT CASCADE INMONITOR (VGA) ALARM/CONTROLSERIALALARM POWER COPY 1 MODEEXT STORAGE 10/100BASE-T RS485(CAMERA)DATAAC IN SIGNAL GND142 WJ-MPU955A (Equipped with WJ-ASC960) Cam9 Cam4 Cam3 Cam5 Cam6 Cam7 Cam8Cam2 Cam1 Cam 13Cam10 Cam11 Cam14 Cam15 Cam16 Mon1 Mon2 Mon3 Mon4Cam12Encoder 1 Encoder 2 Decoder 1
14 Encoder WJ-GXE900 Setup Same as System850 description Decoder WJ-GXD900 Setup Same as System850 description L3SW Setup Same as System850 description WJ-SX650 Setup Slot # Board name Rotary Switch/Mode Qty C Video Input Board 0 1 B A Video Output Board with Network Board Output Board (1) 1 Digital Disk Recorder HD300A Series Setup Same as System850 description
PC with WJ-ASC960 Admin ConsoleSystem Controller (Ethernet)System Controller (Ethernet) POWER ON OFF SIGNALAUDIO IN VIDEO OUT VIDEO IN 100BASE-TX RS-485TERM1GND2 3ON OFF4ALARM INTRIGGER OUTRESET4321G4321GGV+ –G Encoder 1-1 Encoder 1-2 Decoder 1-1 Decoder 2-1 Switching HUBSwitching HUB L3SW-1L2SW WJ-GXE900 192.168.1.10 POWER ON OFF SIGNALAUDIO IN VIDEO OUT VIDEO IN 100BASE-TX RS-485TERM1GND2 3ON OFF4ALARM INTRIGGER OUTRESET4321G4321GGV+ –G WJ-GXE900 192.168.1.11 WJ-GXD900 192.168.2.10 WJ-MPU955A Equipped with WJ-ASC960 SIGNAL GND POWERONOFF3 3 1 4 21 42 VIDEO OUT AUDIO OUT MIX RESET1000BASE-T 100BASE-TXV+–GQUAD PC with WJ-ASC960 Admin Console Switching HUB 192.168.1.1 Switching HUBL3SW-2 WJ-GXD900 192.168.4.10WJ-MPU955A Equipped with WJ-ASC960 SIGNAL GND POWERONOFF3 3 1 4 21 42 VIDEO OUT AUDIO OUT MIX RESET1000BASE-T 100BASE-TXV+–GQUAD 192.168.4.1 192.168.201.1 192.168.201.200 192.168.200.1 192.168.200.200 172.16.192.1 172.18.0.1172.16.192.2 172.18.0.1192.168.2.1192.168.5.1 CPU-1 CPU-2 POWER ON OFF SIGNALAUDIO IN VIDEO OUT VIDEO IN 100BASE-TX RS-485TERM1GND2 3ON OFF4ALARM INTRIGGER OUTRESET4321G4321GGV+ –G Encoder 2-1 Encoder 2-2L2SWWJ-GXE900 192.168.3.10 POWER ON OFF SIGNALAUDIO IN VIDEO OUT VIDEO IN 100BASE-TX RS-485TERM1GND2 3ON OFF4ALARM INTRIGGER OUTRESET4321G4321GGV+ –G WJ-GXE900 192.168.3.11 Switching HUB 192.168.3.1 192.168.5.2 Cam1-1Cam1-2 Cam1-4 Cam1-3 Cam1-5 Cam1-6 Cam1-7 Mon1-1 Mon1-2 Mon1-3 Mon1-4 Mon2-1 Mon2-2 Mon2-3 Mon2-4 Domain 1 1 182IN OUTCASCADE OUT 16 16 3 15 15 1414132 1 13 1212 1111 1010 99 88 77 66 55 44 33 22 11 VIDEOAUDIO IN AUDIO OUTMONITOR OUT CASCADE INMONITOR (VGA) ALARM/CONTROLSERIALALARM POWER COPY 1 MODEEXT STORAGE 10/100BASE-T RS485(CAMERA)DATAAC IN SIGNAL GND142WJ-HD300A Series 172.18.0.60 Digital Disk Recorder 1-1 Digital Disk Recorder 2-1 Cam2-1Cam2-2 Cam2-4 Cam2-3 Cam2-5 Cam2-6Cam2-7 Domain 2 1 182IN OUTCASCADE OUT 16 16 3 15 15 1414132 1 13 1212 1111 1010 99 88 77 66 55 44 33 22 11 VIDEOAUDIO IN AUDIO OUTMONITOR OUT CASCADE INMONITOR (VGA) ALARM/CONTROLSERIALALARM POWER COPY 1 MODEEXT STORAGE 10/100BASE-T RS485(CAMERA)DATAAC IN SIGNAL GND142WJ-HD300A Series 172.18.0.60 10BASE-T/100BASE-TX SERIAL 21 OTHER SYSTEM DEVICE SYSTEM CONTROLLERPOWER ON AC IN OFFSIGNAL GND10BASE-T/100BASE-TX SERIAL 21 OTHER SYSTEM DEVICE SYSTEM CONTROLLERPOWER ON AC IN OFFSIGNAL GND 15 Multiple System Domains with Single GX Switch Node The following system includes two system domains. Each system domain has its own GX switch node. The system domain has two WJ-GXE900 encoders and one WJ-GXD900 decoder. It contains a domain WJ-MPU955A CPU with the WJ-ASC960 upgrade software installed. Within the domain, a PC with WJ-ASC960 Admin Console software installed is required to configure resources and operations within the domain. The two system domains can work independently as standalone systems. The sample Local database – 01=multi_1.adm, 02=multi_2.adm -and sys.ini file – 01A=sys.ini, 02A=sys.ini -for Administration Console are provided on the CD-ROM. The sample Global data- base - #=multi.gdm - for Admin is provided on the CD-ROM. Also refer to Appendix 2.
16 Encoder WJ-GXE900 Setup •Refer to WJ-GXE900 Operational Manual to set following configuration through the Web browser. Encoder # Operation Mode IP Address Subnet Mask Default Gateway DNS Rotary Switch 1-1 Main CPU mode 192.168.1.10 255.255.255.0 192.168.1.1 0.0.0.0 0-0-1 1-2 Main CPU mode 192.168.1.11 255.255.255.0 192.168.1.1 0.0.0.0 0-0-2 2-1 Main CPU mode 192.168.3.10 255.255.255.0 192.168.3.1 0.0.0.0 0-0-3 2-2 Main CPU mode 192.168.3.11 255.255.255.0 192.168.3.1 0.0.0.0 0-0-4 Encoder # MULTICAST IP ADDRESS FOR SETUP in System Setup page 1-1 239.192.255.2(default) 1-2 239.192.255.2(default) 2-1 239.192.255.3 2-2 239.192.255.3 Decoder WJ-GXD900 Setup •Refer to WJ-GXD900 Operational Manual to set following configuration through the Web browser. Decoder # Operation Mode IP Address Subnet Mask Default Gateway DNS Rotary Switch 1-1 Main CPU mode 192.168.2.10 255.255.255.0 192.168.2.1 0.0.0.0 0-1-0 2-1 Main CPU mode 192.168.4.10 255.255.255.0 192.168.4.1 0.0.0.0 0-1-1 Decoder # MULTICAST IP ADDRESS FOR SETUP in System Setup page 1-1 239.192.255.2(default) 2-1 239.192.255.3 Note:The rotary dip-switch valued should not be same as Encoder’s one. L3SW-1 Setup •Set the following IP Address to each port. Port # IP Address Connection 1 192.168.1.1 Encoder #1-1,1-2 2 192.168.2.1 Decoder #1-1 3 192.168.5.1 Link to L3SW-2 4 192.168.200.1 CPU-1 •Valid the IGMP V2 due to support Multicast messages.
17 L3SW-2 Setup •Set the following IP Address to each port. Port # IP Address Connection 1 192.168.3.1 Encoder #2-1, 2-2 2 192.168.4.1 Decoder #2-1 3 192.168.5.2 Link to L3SW-1 4 192.168.201.1 CPU-2 •Valid the IGMP V2 due to support Multicast messages. Digital Disk Recorder HD300A Series Setup Digital Disk Recorder# Line Speed HTTP Port Number DHCP IP Address 1-1 AUTO 00080 OFF 172.018.000.060 2-1 AUTO 00080 OFF 172.018.000.060 Subnet Mask Gateway Unit Address (System) Unit Address (Controller) 255.255.000.000 000.000.000.000 001 001 255.255.000.000 000.000.000.000 001 001
18 Multiple System Domains with Single SX650 Switch Node The following system includes two system domains. Each system domain has its own SX650 switch node. The sys- tem domain has two WJ-SX650 matrix switchers. It contains a domain WJ-MPU955A CPU with the WJ-ASC960 upgrade software installed. Within the domain, a PC with WJ-ASC960 Admin Console software installed is required to configure resources and operations within the domain. The two system domains can work independently as standalone systems. The sample Local database – 01=multi650_1.adm, 02=multi650_2.adm -and sys.ini file – 01A=sys.ini, 02A=sys.ini -for Administration Console are provided on the CD-ROM. The sample Global database - #=multi650.gdm - for Admin is provided on the CD-ROM. Also refer to Appendix 4. Cam1-1 Cam1-4Cam1-2 Cam1-7 Cam1-3 Cam1-5 Cam1-6 Cam1-8Cam2-1 Cam2-4Cam2-2 Cam2-7 Cam2-3 Cam2-5 Cam2-6 Cam2-8 3C 1 2B 1 2 3AC IN3 2 1A SIGNAL GND SIGNAL GND ON4-LineRS485(CAMERA) SET UPMODEON4-LineMODE VIDEO OUT 3 VIDEO OUT 4 VIDEO OUT 2IN X-2VIDEO OUT 1ALARM INEXTENSION 3 INEXTENSION 2 IN4MODERS485 (CAMERA) RS485 (CAMERA)3MODE MODE MODE21IN C-3 MODE MODE MODE MODEDATADATAEXTENSION 1TERM.OFF ON OUTINOUT X-31 2 3 4TERM.ON ON MODETERM.OFF MODEDATA 4 HDR4/TMNL8 HDR2/TMNL4DATA 3 HDR3/TMNL7 HDR1/TMNL3DATA 2 TMNL6 TMNL2DATA 1 TMNL5TMNL1/PS DATAVideo Output Board 2 Video Output Board 1OUT X-21 2 3 4 5 6 7 8MONITOR OUT9 10 11 12 13 14 1516 IN X-116 15 14 13 12 11 10 9CAMERA IN8765432132 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 NETWORK OUT X-1ALARM OUT 2 ALARM OUT 1SERIALVS OUTVS INVS OUT (THRU)Video Output Board 1 Only10/100 BASE-T Mon1 Mon2 Mon3 Mon4 WJ-HD300A Series WJ-SX650 WJ-SX650 1 18 2IN OUTCASCADE OUT 16 16 315 1514 1413 2 11312 1211 1110 109 98 87 76 65 54 43 32 21 1VIDEO AUDIO IN AUDIO OUTMONITOR OUT CASCADE INMONITOR (VGA) ALARM/CONTROLSERIAL ALARMPOWER COPY 1 MODEEXT STORAGE 10/100BASE-T RS485(CAMERA)D ATAAC IN SIGNAL GND142 3C 1 2B 1 2 3AC IN3 2 1A SIGNAL GND SIGNAL GND ON4-LineRS485(CAMERA) SET UPMODEON4-LineMODE VIDEO OUT 3 VIDEO OUT 4 VIDEO OUT 2IN X-2VIDEO OUT 1ALARM INEXTENSION 3 INEXTENSION 2 IN4MODERS485 (CAMERA) RS485 (CAMERA)3MODE MODE MODE21IN C-3 MODE MODE MODE MODEDATADATAEXTENSION 1TERM.OFF ON OUTINOUT X-31 2 3 4TERM.ON ON MODETERM.OFF MODEDATA 4 HDR4/TMNL8 HDR2/TMNL4DATA 3 HDR3/TMNL7 HDR1/TMNL3DATA 2 TMNL6 TMNL2DATA 1 TMNL5TMNL1/PS DATAVideo Output Board 2 Video Output Board 1OUT X-21 2 3 4 5 6 7 8MONITOR OUT9 10 11 12 13 14 1516 IN X-116 15 14 13 12 11 10 9CAMERA IN8765432132 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 NETWORK OUT X-1ALARM OUT 2 ALARM OUT 1SERIALVS OUTVS INVS OUT (THRU)Video Output Board 1 Only10/100 BASE-T Mon1 Mon2 Mon3 Mon4 WJ-HD300A Series 1 18 2IN OUTCASCADE OUT 16 16 315 1514 1413 2 11312 1211 1110 109 98 87 76 65 54 43 32 21 1VIDEO AUDIO IN AUDIO OUTMONITOR OUT CASCADE INMONITOR (VGA) ALARM/CONTROLSERIAL ALARMPOWER COPY 1 MODEEXT STORAGE 10/100BASE-T RS485(CAMERA)D ATAAC IN SIGNAL GND142 PC with WJ-ASC960 Admin ConsoleSystem Controller (Ethernet) Switching HUBSwitching HUB Switching HUBSwitching HUBSwitching HUB 10BASE-T/100BASE-TX SERIAL 21 OTHER SYSTEM DEVICE SYSTEM CONTROLLERPOWER ON AC IN OFFSIGNAL GND WJ-MPU955A (Equipped with WJ-ASC960)WJ-MPU955A (Equipped with WJ-ASC960) PC with WJ-ASC960 Admin ConsoleSystem Controller (Ethernet) 10BASE-T/100BASE-TX SERIAL 21 OTHER SYSTEM DEVICE SYSTEM CONTROLLERPOWER ON AC IN OFFSIGNAL GND172.18.0.1 172.16.192.2 172.18.0.1192.168.200.200192.168.200.200 172.16.192.1 Domain 1Domain 2
19 WJ-SX650 Setup Slot # Board name Rotary Switch/Mode Qty C Video Input Board 0 1 B A Video Output Board with Network Board Output Board (1) 1 Digital Disk Recorder HD300A Series Setup Same as Single System Domain with Both GX and SX850 Switch Node on page 12
20 System Setup Define a System Domain Number of System Domains By definition, each system domain must have a WJ-MPU955A CPU. If it is a redundant system, it must have two WJ-MPU955A CPUs. The system can consist of up to 64 system domains. Domain and Unit ID Assignments For each CPU, you must assign a Unit ID. Once a Unit ID is assigned, the system will refer to its Domain ID equal to this Unit ID. Enter Unit ID in the WJ-ASC960 Admin Console In the WJ-ASC960 Admin Console main screen, select CPU Unitson the Domainmenu. TheCPU System Configuration screen will be activated. Then, enter the Unit(s)information into the fields provided. In the following table, we used the example on page 15 to show what information you would need to enter. Unit ID Main IPA [A] Backup IPA [B] Unit Name Size 1 172.16.192.1–Domain 1 Enhanced 2 172.16.192.2–Domain 2 Enhanced Enter Unit ID in the System Configuration File In each WJ-MPU955A CPU, there is a system configuration file named SYS.INI. You can view and edit the file through WJ-ASC960 Admin Console. For each new system domain that is set up, you need to enter the correct ID in the [UNIT] section of the SYS.INI file. The following is the text from the SYS.INI files [UNIT] section. [UNIT] ***{ The unit ID should be the same as the one defined in } ***{ the Global Admin database for this unit. } ***{ For single-unit systems, use ID=1. (ID=0 is invalid) } ID=1