Page 61
61 Admin sample Global database (#=multi650.gdm) work sheet [CPU System Configuration] Unit ID Main IPA [A] Backup IPA [B] Unit Name Size 1 172.16.192.1–Unit 1 Enhanced 2 172.16.192.2–Unit 2 Enhanced [LINK] [OPERATORS] User ID Password Priority Timeout Name Class 500 500 2 00:00:00 Global Operator 20: Global Level 0 501 501 2 00:00:00 Global Operator 20: Global Level 0 Link ID 11 SX650 13 2 SX650 13 1 21 SX650 14 2 SX650 14 1 31 SX650 15 2 SX650 15 1 4 5 1 2SX650 SX65016 132 1SX650 SX65016 131 1 62...
Page 62
62 sys.ini configuration for Unit1 (01 A=sys.ini) [INTERFACES] ***{ Number of interfaces in the system } Numinterfaces=3 ***{ Interface Definitions } ***{ Interface=,, } ***{ !! Note: The InterfaceX IPAs must match the MainX CPU } ***{ hardware settings in order for the System to } ***{ operate correctly!! ***{ MainA CPU } Interface0=192.168.200.200,255.255.255.0,192.168.200.200 Interface1=172.18.0.1,255.255.0.0,172.18.0.1 Interface2=172.16.192.1,255.255.0.0,172.16.192.1 ***{ MainB CPU...
Page 63
63 TimeDatePosition=1,1 CamTitlePosition=1,16 MonStatusPosition=1,15 GenStatusPosition=1,14 ***{ Time-Date, Camera Title and Camera ID Controls } ***{ Code 2 takes effect only if source is MXOSD } ***{ Format: = } ***{ control code 0 - OFF } ***{ control code 1 - ON } ***{ control code 2 - By Operator } TimeDateControl=2 CamTitleControl=2 CamIDControl=2 ***{ Time and Date display format } ***{ Format: TimeDateFormat= } ***{ format 0 - DD/MM/YYYY } ***{...
Page 64
64 [RS232ALARM] ***{ This section is optional. It is not required unless } ***{ System defaults are not acceptable. Delete the } ***{ single asterisks below to make this section active. } ***{ Enable/Disable Serial Alarms by port } ***{ Note: Port 2 is dedicated to redundant communication } ***{ if REDUNDANT:YES is selected by front panel } ***{ switch. } ***{ Format: AlarmPort=, } ***{ port # = use 1 to indicate desired port (only one) } ***{ port # = use 0 to...
Page 65
65 ***{ single asterisks below to make this section active. } ***{ This section lists user-defined client SNTP values, } ***{ sync rates and an external server address. } ***{ } ***{ Format: (VALUES INTERNAL TO THIS UNIT) } ***{ ClientMode= (act as an SNTP client) } ***{ modes: 0 - Internal (default) } ***{ 1 - Unicast } ***{ 2 - Anycast } ***{ 3 - Broadcast } ***{...
Page 66
66 ***{ MainB CPU } *Interface0=192.168.200.201,255,255,255,0,192.168.200.201 *Interface1=172.18.0.2,255.255.0.0,172.18.0.2 *Interface2=172.16.192.2,255.255.0.0,172.16.192.2 [FRAMES] ***{ MX Frame definition from Admin file } ***{ MXSW has format ,, } ***{ All others use , } ***{ All 0s used for digital-only systems. } MXSWFunction=0,0,0 MXCONTFunction=0,0 MXOSDFunction=0,0 MXDIOFunction=0,0 MXRMSFunction=0,0 [PROCS] ***{ Process Interface Assignments } ***{ Format: = }...
Page 67
67 ***{ Format: TimeDateFormat= } ***{ format 0 - DD/MM/YYYY } ***{ format 1 - MM/DD/YYYY } ***{ format 2 - DD/Mmm/YYYY } ***{ format 3 - YYYY/MM/DD } ***{ format 4 - Mmm/DD/YYYY } ***{ format 5 - DD/MM/YY } ***{ format 6 - MM/DD/YY } ***{ format 7 - DD/Mmm/YY } ***{ format 8 - YY/MM/DD } ***{ format 9 - Mmm/DD/YY } TimeDateFormat=1 ***{ Time-Hour Display format } ***{ Format: TimeHourFormat= } ***{ format 0 - 12 Hou } ***{ format 1 - 24 Hour }...
Page 68
68 [ALARMTEXTDISPLAY] ***{ This section is optional. It is not required unless } ***{ System defaults are not acceptable. Delete the } ***{ single asterisks below to make this section active. } ***{ Alarm Text Display format } ***{ Format: AlarmTextDisplay= } ***{ option 0 - Display Alarm Text only } ***{ option 1 - Display both Alarm Text (20 chars) } ***{ and Action Text (20 chars) } *AlarmTextDisplay=0 [SYSTEM] ***{ This section is optional. It is not required unless } ***{...
Page 69
69 ***{ 1 - On (default) } ***{ InternalFrequency= } ***{ -default is 600 sec (10 min) } ***{ } ***{ (VALUES FOR EXTERNAL CONNECTION) } ***{ NTPServerIPA= of SNTP server } ***{ -for Unicast mode only; optional for } ***{ modes 0,2,3. } ***{ ExternalFrequency= } ***{ -default is 18000 sec (5 hrs)...
Page 70
Information on Disposal for Users of Waste Electrical & Electronic Equipment (private households) This symbol on the products and/or accompanying documents means that used electrical and electronic products should not be mixed with general household waste. For proper treatment, recovery and recycling, please take these products to designated collection points, where they will be accepted on a free of charge basis. Alternatively, in some countries you may be able to return your products to your local...