Panasonic Th 42pr10r Operating Instructions
Have a look at the manual Panasonic Th 42pr10r Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
31 1/2 PC Off Standby saveOff Power management Off Auto power off Off OSD Language English ( UK) Component/RGB-in select RGB Input labelSignal Power save Setup 1/2 PC Off Standby saveOn Power management Off Auto power off Off OSD Language English ( UK) Component/RGB-in select RGB Input labelSignal Power save Setup Reduces power consumption Press to select “Power save” “Standby save” “Power management” “Auto power off”. Press to select “On” or “Off”. On Off Press to exit from Setup. • Power save: When this function is turned On, luminous level of the Plasma Display is suppressed, so power consumption is reduced. • Standby save: When this function is turned On, power consumption of the microcomputer is reduced during power supply standby (see page 11, 12-13), so standby power of the set is reduced. • Power management: The unit power supply is turned On or Off depending on whether or not there is a signal during PC input mode. This function is enabled when it is turned On. (Only during input from PC (Mini D-sub) terminal) • Auto power off: Equipment power supply is turned Off when there is no signal. When this is set to On, the power supply of the unit goes Off 10 minutes after the input signals stop. This function is effective for input signals except input from PC (Mini D-sub) terminal. Press to select Input label. Press to change the Input label. Customizing the Input labels This function can change the label of the Input signal to be displayed. Select the input signal which you would like to change its label before customizing the Input labels. (see page 13, 16) Note: While selecting an Input signal through Optional Terminal Board connected to Slot1, Slot2 and Slot3, the Input label will depend on each Optional Terminal Board. Input labels for Slot1, Slot2, Slot3 and Mini D-sub: [Slot1 Input] INPUT1 / VIDEO1 / COMPONENT1 / RGB1 / DIGITAL1 / PC1 / DVD1 / CATV1 / VCR1 / STB1 [Slot2 Input] INPUT2 / VIDEO2 / COMPONENT2 / RGB2 / DIGITAL2 / PC2 / DVD2 / CATV2 / VCR2 / STB2 [Slot3 Input] INPUT3 / VIDEO3 / COMPONENT3 / RGB3 / PC3 / DVD3 / CATV3 / VCR3 / STB3 [PC (Mini D-sub) input] PC / COMPONENT / RGB / DVD / STBNote: “Power management” and “Auto power off” are effective during normal viewing (one picture screen) only. 1 2 3 Addition sign“A” “B” Selected InputComposite S VIDEO When BNC Dual Video Terminal Board (TY-FB9BD) is used, an “A” or “B” is added at the end of each input label, depending on the input selected (see below). Ofrecido por www.electromanuales.com
32 1/2 PC Off Standby save Off Power management Off Auto power off Off OSD Language English ( UK) Component/RGB-in select RGB Input label Signal Power save Setup 1/2 PC Off Standby save Off Power management Off Auto power off Off OSD LanguageEnglish ( UK) Component/RGB-in select RGB Input labelSignal Power save Setup 3D Y/C Filter (NTSC) Colour system Signal On Auto Cinema reality Panasonic Auto (4 : 3)Off 4 : 3 P-NROff [ AV ] Setup for Input Signals Component / RGB-in select Select to match the signals from the source connected to the Component / RGB input terminals. Y, P B, PR signals “Component” R, G, B, HD, VD signals “RGB” 1 2Press to display the Setup menu. Press to select the “Component / RGB-in select”. Press to select the desired input signal. Component RGB Press to exit from adjust mode. 3D Y/C Filter – For NTSC AV images Select “Signal” from the “Setup” menu during AV(S Video) input signal. (“Signal [AV]” menu is displayed.) Press to select the “3D Y/C Filter (NTSC)” Press to set On / Off. Press to exit from adjust mode. Note: When On, this setting only affects NTSC input signals. Note: Selection may not be possible, depending on which optional board is installed. 3 1 2 Press ACTION ( ) button Ofrecido por www.electromanuales.com
33 1/2 PC Off Standby save Off Power management Off Auto power off Off OSD LanguageEnglish ( UK) Component/RGB-in select RGB Input labelSignal Power save Setup 3D Y/C Filter (NTSC) Colour system Signal On Auto Cinema reality Panasonic Auto (4 : 3)Off 4 : 3 [ AV ] P-NROff 1/2 PC Off Standby save Off Power management Off Auto power off Off OSD LanguageEnglish ( UK) Component/RGB-in select RGB Input labelSignal Power save Setup 1 23D Y/C Filter (NTSC) Colour system Signal On Auto Cinema reality Panasonic Auto (4 : 3)Off 4 : 3 [ AV ] P-NROff Cinema reality P-NR Signal Off Off [ Component ] Cinema reality P-NR Signal Off Off H-Freq. V-Freq.kHz Hz33.8 60.0 [ Digital ] Sync P-NR Signal Auto H-Freq. V-Freq.kHz Hz33.8 60.0 [ RGB ] Cinema realityOff Off Setup for Input Signals Colour system / Panasonic Auto Select Signal from the “Setup” menu during AV(S Video) input signal. (“Signal [AV]” menu is displayed.) Press to select the “Colour system” or “Panasonic Auto”. Press to select each functions. If the picture image becomes unstable: With the system set on Auto, under conditions of low level or noisy input signals the image may in rare cases become unstable. Should this occur, set the system to match the format of the input signal. Cinema reality / P-NR Press to select Cinema reality or P-NR. Press to set On / Off. Press to exit from adjust mode. Cinema reality: When on, the display attempts to reproduce a more natural interpretation of sources such as movie pictures, which are recorded at 24 frames per second. If the picture is not stable, turn the setting to off. Note: When On, this setting only affects the following signal input: • NTSC / PAL signal input during “AV(S Video)” input signal. • 525i(480i), 625i(575i), 1125(1080) / 60i signal input during “Component” input signal. P-NR: Automatically reduces unwanted picture noise. Note: P-NR cannot be adjusted while a PC signal is being applied.Press ACTION ( ) button Press ACTION ( ) button Mode Function Colour systemSet the colour system to match the input signal. When selecting “Auto”, the color system is automatically selected from NTSC/PAL/SECAM, however, M.NTSC signal is not displayed properly depending on the attached terminal board. To display M.NTSC signal, select “M.NTSC” in Colour system. Auto SECAM M.NTSC NTSCPA L Panasonic Auto (4 : 3)Set to “4 : 3” to view 4:3 images in an unchanged format when Panasonic Auto is selected. If you would like to view 4:3 images in Just format, set to “Just”. Note: Panasonic Auto does not function when BNC Dual Video Terminal Board (TY-FB9BD) is used. Ofrecido por www.electromanuales.com
34 Sync Auto Sync on G Sync VBS 1/2 PC Off Standby save Off Power management Off Auto power off Off OSD LanguageEnglish ( UK) Component/RGB-in select RGB Input labelSignal Power save Setup Sync P-NR Signal Auto H-Freq. V-Freq.kHz Hz33.8 60.0 [ RGB ] Cinema realityOff Off H-Freq. V-Freq.kHz Hz33.8 60.0 3D Y/C Filter (NTSC) Colour system Signal Auto Cinema reality Panasonic Auto (4 : 3) Off 4 : 3 [ AV ] P-NR Off Refresh Rate100 Hz Cinema reality P-NR Signal Off Off [ Component ] Refresh Rate100 Hz Cinema reality P-NR Signal Off Off H-Freq. V-Freq.kHz Hz33.8 60.0 [ Digital ] Refresh Rate100 Hz Sync P-NR Signal Auto H-Freq. V-Freq.kHz Hz33.8 60.0 [ RGB ] Cinema reality Off Off Refresh Rate100 Hz Select Signal from the “Setup” menu during RGB input signal. Press to adjust. Setting RGB sync signal: Confi rm that the input is set to RGB input (this setting is valid only for RGB input signal). Auto: The H and V sync or synchronized signal are automatically selected. If both input, it is selected the H and V sync. on G: Uses a synchronized signal on the Video G signal, which is input from the G connector. VBS: Uses a synchronized signal of Composite Sync input, which is input from the HD connector. Displays the H (Horizontal) / V (Vertical) frequencies. This display is valid only for RGB / PC and Digital input signal. Display range: Horizontal 15 - 110 kHz Vertical 48 - 120 Hz H-Freq. (kHz) / V-Freq. (Hz) Sync 1 2 Press ACTION ( ) button Press to exit from adjust mode. Refresh Rate (for TH-37PR10R, TH-42PR10R) Press to select Refresh Rate. Press to adjust. This function sets the refresh rate of the display. This menu is displayed when the input signal is 50 Hz system (50i, 50p, 25p, 24p, 24sF) of vertical scan rate. 100 Hz: Reduce screen fl icker. 50 Hz: Enhance the resolution of moving images. Note: It is recommended to set to 100 Hz normally.1 2 Press to exit from adjust mode. Setup for Input Signals Ofrecido por www.electromanuales.com
35 1/3Options Off-timer function INPUT lock Studio W/B Advanced PIP Display size Initial VOL level Maximum VOL level Initial INPUT Onscreen display Off Off Off Off Enable On Off 0 Off Off 0 Options Adjustments 1 2 3 5Press to display the Setup menu. Press to select “OSD Language”. Press and hold until the Options menu is displayed. Press to select your preferred menu. Press to adjust the menu. Press to exit from Options menu. 4 6 Item Effect Adjustments Off-timer function EnableDisable Enable: Enables the “Off-timer function”. Disable: Disables the “Off-timer function”. Note: When “Disable” is set, the Off-timer is cancelled. Onscreen display On Off On: Displays all the following on screen. • Power on display • Input signal switch display • No signal display • Mute and the remaining time of off-timer after was pressed. Off: Hides all the items above from view. Initial INPUTOff PC INPUT1 INPUT2 INPUT3 Adjusts the input signal when the unit is turned on. Notes: • Only the adjusted signal is displayed. (see page 16). • Signal can be displayed when the Terminal board is installed. • This menu is available only when “INPUT lock” is “Off”. • When a dual input terminal board is attached, A or B is displayed depending on the selected input signal. (Ex. INPUT1A, INPUT1B) (For TH-42PG10R) Ofrecido por www.electromanuales.com
36 1/3Options Off-timer function INPUT lock Studio W/B Advanced PIP Display size Initial VOL level Maximum VOL level Initial INPUT Onscreen display Off Off Off Off Enable On Off 0 Off Off 0 Options Adjustments Item Effect Adjustments Initial VOL level Off On Press button to adjust the volume when the unit is turned on. Off On Off: Sets normal volume. On: Sets your preferred volume. Notes: • When “Maximum VOL level” is “On”, the volume can only be adjusted between 0 and your maximum range.• You can hear the changed volume regardless of your volume setting before opening the options menu if you adjust the volume when “Initial VOL level” is “On” and cursor is on the menu. Maximum VOL level Off On Press button to adjust the maximum volume. Off On Off: Sets auto maximum volume. On: Sets your preferred maximum volume. Notes: • If the “Maximum VOL level” is set lower than the “Initial VOL level”, the “Initial VOL level” automatically becomes the same as the “Maximum VOL level”. • The volume display can go up to 63 regardless of the settings. • You can hear the changed volume regardless of your volume setting before opening the options menu if you adjust the volume when “Maximum VOL level” is “On” and cursor is on the menu. INPUT lockOff PC INPUT1 INPUT2 INPUT3 Locks the input switch operation. Notes: • Only the adjusted signal is displayed (see page 16). • Signal can be displayed when the Terminal board is installed. • Input switch can be used when this is set to “Off”. • In two screen display mode, if anything other than “Off” is set, the value will be fi xed as the value input in the single screen display mode. • When a dual input terminal board is attached, A or B is displayed depending on the selected input signal. (Ex. INPUT1A, INPUT1B) Studio W/B Off On Off: Nullify all the settings adjusted. On: Sets the colour temperature for TV studio. Note: Valid only when the low is set as colour temperature on screen adjustment. Advanced PIP Off On Off: Sets normal two screen display mode (see page 19). On: Sets Advanced PIP mode (see page 20). Notes: • When “INPUT lock” is “On”, you cannot use all the two screen display functions. • , buttons are unavailable during Advanced PIP mode operation. Display size Off On Adjusts the image display size on screen. Off: Sets the normal image display size on screen. On: Sets the image display size approximately 95 % of the normal image display. Off On Notes: • This setting is valid only when the input signals are as follows; 525i, 525p, 625i, 625p, 750/60p, 750/50p, 1125/60i, 1125/50i, 1125/24sF, 1125/25p, 1125/24p, 1125/30p, 1250/50i (Component Video, RGB, DVI, SDI, HDMI) • This setting is invalid when two screen display, digital zoom or Multi screen is selected. • When Display size is set to “On”, Pos. /Size adjustment cannot be used. • Refer to each board’s operating instruction for DVI, SDI, HDMI’s corresponding signals. Ofrecido por www.electromanuales.com
37 2/3Options OffOffOff Off 0 Remote ID Serial ID ID select Button lock Remocon User level 3/3Options Off Off Off V. lnstallation Rotate Slot1 Serial Slot Select Slot power Normalization When both main unit buttons and remote control are disabled due to the “Button lock”, “Remocon User level” or “Remote ID” adjustments, set all the values “Off” so that all the buttons are enabled again. Press the VOLbutton on main unit together with button on the remote control and hold for more than 5 seconds. The “SHIPPING” menu is displayed and the lock is released when it disappears.Item Effect Adjustments Button lockOff MENU&ENTER On Off: All the buttons at the bottom of the main unit can be used. MENU & ENTER: Locks MENU and ENTER/ buttons on bottom face of main unit. On: Locks all the button on bottom face of main unit. Remocon User levelOff User1 User2 User3 Off: You can use all of the buttons on the remote control. User1: You can only use , , , , , , , buttons on the remote control. User2: You can only use , , buttons on the remote control. User3: Locks all the buttons on remote control. ID selectSets panel ID number when panel is used in “Remote ID” or “Serial ID”. Set value range: 0 - 100 (Standard value: 0) Remote ID Off On Off: Disables ID remote control functions. You can use normal remote control operations. On: Enable ID remote control functions. Serial ID Off On Sets the panel ID Control. Off: Disables external control by the ID. On: Enables the external control by the ID. Item Effect Adjustments Slot PowerOff Auto On Off: Power is not transmitted to the slot power. Auto: Power is transmitted to the slot power only when main power is on. On: Power is transmitted to the slot power when main power is on or in the standby state. Note: In some cases, power is transmitted to the slot power when main power is on or in the standby state regardless of the slot power setting. V.Installation Off OnThis mode is unavailable. Rotate Off On Off: Does not rotate the image. On: Rotates the image 180 degrees. Serial Slot SelectSlot1 Slot2 Slot3 Selects the slot which communicates serial. Note: The setting of an external command can be set only from the fi xed serial terminal (see page 10). Options Adjustments Ofrecido por www.electromanuales.com
38 Options Weekly Command Timer Initial VOL level 1/3 Off Off 0 0 Maximum VOL level Off INPUT lock Off Button lock Off Remocon User level Off Advanced PIP Initial INPUT Onscreen display On O f f Item Effect Adjustments Weekly Command TimerSets Weekly Command Timer. (see page 42) Onscreen display On Off On: Displays all the following on screen. • Power on display • Input signal switch display • No signal display • Mute and the remaining time of off-timer after was pressed. Off: Hides all the items above from view. Initial INPUTOff PC INPUT1 INPUT2 INPUT3 Adjusts the input signal when the unit is turned on. Notes: • Only the adjusted signal is displayed. (see page 16). • Signal can be displayed when the Terminal board is installed. • This menu is available only when “INPUT lock” is “Off”. • When a dual input terminal board is attached, A or B is displayed depending on the selected input signal. (Ex. INPUT1A, INPUT1B) 1 2 3 5Press to display the Setup menu. Press to select “OSD Language”. Press and hold until the Options menu is displayed. Press to select your preferred menu. Press to adjust the menu. Press to exit from Options menu. 4 6 Options Adjustments (For TH-37PR10R, TH-42PR10R) Ofrecido por www.electromanuales.com
39 Options On Weekly Command Timer Onscreen display Off Initial INPUT 1/3 Maximum VOL level Initial VOL level Button lock INPUT lock Advanced PIP Remocon User level Off Off 0 0 Off Off Off Off Item Effect Adjustments Initial VOL level Off On Press button to adjust the volume when the unit is turned on. Off On Off: Sets normal volume. On: Sets your preferred volume. Notes: • When “Maximum VOL level” is “On”, the volume can only be adjusted between 0 and your maximum range. • You can hear the changed volume regardless of your volume setting before opening the options menu if you adjust the volume when “Initial VOL level” is “On” and cursor is on the menu. Maximum VOL level Off On Press button to adjust the maximum volume. Off On Off: Sets auto maximum volume. On: Sets your preferred maximum volume. Notes: • If the “Maximum VOL level” is set lower than the “Initial VOL level”, the “Initial VOL level” automatically becomes the same as the “Maximum VOL level”. • The volume display can go up to 63 regardless of the settings. • You can hear the changed volume regardless of your volume setting before opening the options menu if you adjust the volume when “Maximum VOL level” is “On” and cursor is on the menu. INPUT lockOff PC INPUT1 INPUT2 INPUT3 Locks the input switch operation. Notes: • Only the adjusted signal is displayed (see page 16). • Signal can be displayed when the Terminal board is installed. • Input switch can be used when this is set to “Off”. • In two screen display mode, if anything other than “Off” is set, the value will be fi xed as the value input in the single screen display mode. • When a dual input terminal board is attached, A or B is displayed depending on the selected input signal. (Ex. INPUT1A, INPUT1B) Button lockOff MENU&ENTER On Off: All the buttons at the bottom of the main unit can be used. MENU & ENTER: Locks MENU and ENTER/ buttons on bottom face of main unit. On: Locks all the button on bottom face of main unit. Sets Button lock with the unit buttons in the following procedure. Off: Press four times→Press INPUT four times→Press four times→Press ENTER/MENU & ENTER: Press ENTER/ four times→Press four times→Press INPUT four times→Press ENTER/On: Press four times→Press ENTER/ four times→Press four times→Press ENTER/ Remocon User levelOff User1 User2 User3 Off: You can use all of the buttons on the remote control. User1: You can only use , , , , , , , buttons on the remote control. User2: You can only use , , buttons on the remote control. User3: Locks all the buttons on remote control. Advanced PIP Off On Off: Sets normal two screen display mode (see page 19). On: Sets Advanced PIP mode (see page 20). Notes: • When “INPUT lock” is “On”, you cannot use all the two screen display functions. • , buttons are unavailable during Advanced PIP mode operation. Options Adjustments Ofrecido por www.electromanuales.com
40 Options EnableOff-timer function NormalInitial Power Mode0ID selectOffRemote IDOffSerial IDOffDisplay sizeOffStudio W/BOffStudio Gain 2/3 Item Effect Adjustments Off-timer function EnableDisable Enable: Enables the “Off-timer function”. Disable: Disables the “Off-timer function”. Note: When “Disable” is set, the Off-timer is cancelled. Initial Power ModeNormal Standby On Sets the power mode of the unit for when the power recovers from failure or after plugging off and in again. Normal: Power returns in as the same state as before the power interruption. Standby: Power returns in standby mode. (Power Indicator : red/orange) On: Power returns in power On. (Power Indicator : green) Note: When using multiple displays, “Standby” is preferred to be set in order to reduce a power load. ID selectSets panel ID number when panel is used in “Remote ID” or “Serial ID”. Set value range: 0 - 100 (Standard value: 0) Remote ID Off On Off: Disables ID remote control functions. You can use normal remote control operations. On: Enable ID remote control functions. Serial ID Off On Sets the panel ID Control. Off: Disables external control by the ID. On: Enables the external control by the ID. Display size Off On Adjusts the image display size on screen. Off: Sets the normal image display size on screen. On: Sets the image display size approximately 95 % of the normal image display. Off On Notes: • This setting is valid only when the input signals are as follows; NTSC, PAL, SECAM, M.NTSC, PAL60, PAL-M, PAL-N (BNC Dual Video Terminal Board (TY-FB9BD)) 525i, 525p, 625i, 625p, 750/60p, 750/50p, 1125/60i, 1125/50i, 1125/24sF, 1125/25p, 1125/24p, 1125/30p, 1250/50i (Component Video, RGB, DVI, SDI, HDMI) • This setting is invalid when two screen display, digital zoom or Multi screen is selected. • When Display size is set to “On”, Pos. /Size adjustment cannot be used. • Refer to each board’s operating instruction for DVI, SDI, HDMI’s corresponding signals. Studio W/B Off On Off: Nullify all the settings adjusted. On: Sets the colour temperature for TV studio. Note: Valid only when the low is set as colour temperature on screen adjustment. Studio Gain Off On Sharpens the contrast for a better view when a part of the image is too light to see. Off: Disables “Studio Gain”. On: Enables “Studio Gain”. Note: This setting is valid only when the input signals are as follows: Component Video, RGB (analog), SDI, HDMI Options Adjustments Ofrecido por www.electromanuales.com