11 SYSTEM CONNECTION The WV-CU161 can be connected with a camera, a video monitor and a Time Lapse VCR. A typical connection example is shown below. Basic System Connection WV-CS854 WV-CU161 Time Lapse VCR System Controller WV-CU123467890 5SHIFT OPERATE ALARM RESET RESET SUSPEND CAMERA SETUPPATROL PLAY PROGRAM PRESET CAMERA FUNCTIONSETUP ESC HOME SET PRESET WIDE TELE NEAR AUX1B/W AUTO WIPER AUX2DEFUP DOWNR L FA R FOCUS IRIS CLOSS OPENPROGRAMALARMIRIS RESETAUTO FOCUS Video Monitor Camera Site Control...
Page 12
12 Connection with a Video Switcher Connected with a video switcher, the WV-CU161 allows you to control multiple combination cameras. WV-CS854 Video SwitcherCamera HousingCamera Receiver R System Controller WV-CU161 System Controller WV-CU123467890 5SHIFT OPERATE ALARM RESET RESET SUSPEND CAMERA SETUPPATROL PLAY PROGRAM PRESET CAMERA FUNCTIONSETUP ESC HOME SET PRESET WIDE TELE NEAR AUX1B/W AUTO WIPER AUX2DEFUP DOWN L FA R FOCUS IRIS CLOSS OPENPROGRAMALARMIRIS RESETAUTO FOCUS Video Monitor Time Lapse...
Page 13
13 RS-485 Site Communication Connection via Codec for Camera Distance of 1 200 m (4 000 ft) or More WV-CS854AV Codec AV Codec R System Controller WV-CU161 System Controller WV-CU123467890 5SHIFT OPERATE ALARM RESET RESET SUSPEND CAMERA SETUPPATROL PAY PROGRAM PRESET CAMERA FUNCTIONSERUP ESC HOME SET PRESET WIDE TELE NEAR AUX1B/W AUTO WIPER AUX2DEFUP DOWN L FA R FOCUS IRIS CLOSS OPENPROGRAMALARMIRIS RESETAUTO FOCUS Video Monitor DATA PORT DATA PORT VIDEO OUT CAMERA IN VIDEO OUT RS-485 Cable Coaxial...
Page 14
14 Connection with a Time Lapse VCR Connect the time lapse VCR as shown in the example below. Make sure the polarity of the buzzer matches the terminal. Connect the positive (+) terminal of the buzzer to the Alarm Output Terminal. The Alarm Output Terminal is an Open Collector terminal with a capacity of 16 V DC, 100 mA or less. (1) Connect the buzzer as shown below if its rating lies within the capacity of the Alarm Output Terminal. (2) Use an external relay unit as shown below if the buzzer rating...
Page 15
15 Internal Diagram RS-485 Terminal Control data is transmitted and received to and from other peripherals. Use a data grade, double-shielded, twisted pair cable, suitable for the RS-485. Cable length may be extended up to 1 200 m (4 000 ft). TR RS485 A B A B G GND 5 TB TA RB RA4321 RA TB 4 3 2 1 TA RB
Page 16
16 SETUP MENU The Setup menu has four main submenus: Alarm Setup, System Setup, Preset Data Load, and Communication. All of these main menus are further divided into submenus. ALARM SETUP*1 ALARM TERMINAL SYSTEM SETUP*2 PRESET DATA LOAD*3 PRESET DATA LOAD CAM 1 PRESET DATA LOAD CAM 2 PRESET DATA LOAD CAM 3 PRESET DATA LOAD CAM 4 PRESET DATA LOAD CAM 5 PRESET DATA LOAD CAM 6 PRESET DATA LOAD CAM 7 PRESET DATA LOAD CAM 8 COMMUNICATION*4 SETUP...
Page 17
17 WV-CU161 SETUP MENU *.** ALARM SETUP SYSTEM SETUP PRESET DATA LOAD COMMUNICATION Note:The COMMUNICATION parameter appears when the data switch is set to RS-485 (See page 9). Key Functions on the Setup Menu SHIFT button + CAMERA SETUP/SETUP/PROGRAM button: To display the program menu. Press CAMERA SETUP /SETUP button for 2 seconds or more after pressing the SHIFT button. SHIFT CAMERA SETUP SETUP PROGRAM PRESET/SET/PROGRAM PRESET button: To execute modes and parameters. To enter a submenu...
Page 18
18 (1) Alarm Display Setting This item lets you select whether or not the message ALARM on the monitor when the alarm is activated. 1. Display the ALARM SETUP menu. 2. Select ALARM DISPLAY by moving the joystick up or down. 3. To have ALARM displayed, select ON for the ALARM DISPLAY parameter. Otherwise select OFF by moving the joystick to the right or left. The initial factory setting is ON. Note:The display time differs depending on (4) Alarm Output Setting. (2) Site Alarm Setting This item lets you...
Page 19
19 ALARM SETUP ALARM DISPLAY ON SITE ALARM ON TERM.ALARM ON ALARM OUTPUT 10S ALARM BUZZER ON ALARM TERMINAL System Setup 1. Display the Setup menu. 2. Select SYSTEM SETUP by moving the joystick up or down. 3. Press the PRESET/SET/PROGRAM PRESET button. The SYSTEM SETUP menu appears on the monitor as shown below. SYSTEM SETUP CABLE COMP S SWITCH BUZZER ON • For using alarm input terminals 1-4 1. Display the ALARM SETUP menu. 2. Select ALARM TERMINAL by...
Page 20
ERROR 2 20 Message Cause Note Lack of memory Memory capacity was exceeded while down- loading. ERROR 3 Causes except aboveDownloading not possi- ble for some reason other than the above. PRESET DATA LOAD CAM1: CAM2: CAM3: CAM4: CAM5: CAM6: CAM7: CAM8: P: Data saved. : No Data saved. (CAM1 - CAM8 of the initial factory setting are marked all .) (1) Download Setting 1. Display the PRESET DATA LOAD menu. 2. Select a camera number between CAM1 and CAM8 by moving the joystick up...