Have a look at the manual Panasonic Sub Monitor Station Video Intercom System Vl Gm001a Installation And Operation Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
11 3Install the bottom case to a wall using the wood screws (4 mm x 35 mm, 3/16″ x 13/8″). •Before drilling, see page 8 for installation location. Introduction and Installation
12 5Attach the wires that connect to the monitor station and sub monitor station to the terminal. See page 16 for details on how to attach the wires. •See page 9 for the wire type and distance. •See the wiring schematic diagram on page 9. 4Attach the power cable to the terminal. See page 16 for details on how to attach the power cable. •If you want to use your own power cable, see page 9 for the type and distance. Button Power switch •When the front case is attached, the power switch will be pressed and power will be supplied. Terminal (Non polar) Wire (Not included) Introduction and Installation
13 •Check that there are no scraps from the board or other debris in the connector before installing it. Remove the front case from the bottom case Bottom case Front case While pushing the tabs at the top of the front case, pull the top of the front case forward to disengage the front tabs one by one, and then pull the top of front case forward to remove it. Remove the connector screw, and then remove the connector. Do not pull the wire when removing the connector. Introduction and Installation 6Remove the sheet covering the connector. Next, after installing the terminal cover in the bottom case, attach the connector by tightening the connector screw. Next, align the lower portion of the bottom case with the lower portion of the front case and press on the panel area just above the screen until the tabs lock in place.Connector screw Screwdriver +
14 Introduction and Installation Arrow mark DC terminal AC adaptor 8Connect the power cable to the DC terminal, the power cord to the AC adaptor, then connect the power cord to the AC outlet (100 V – 240 V, 50 Hz / 60 Hz). •Be sure to connect the power cable to the 2 holes on the left side of the DC terminal. •For details on how to attach the power cable, see page 16. DC terminal AC adaptor Power cord To AC outlet Power cable 9Attach the DC cord to the clamp on the rear of the DC terminal. • This will help to avoid the DC cord to disconnect from the DC terminal. DC terminal DC cord Clamp 7Take out the AC adaptor and the DC terminal from the case. •Push the arrow mark on the front case, then release from the rear case. •Take out the cardboard and wood screws. The wood screws are necessary when attaching the AC adaptor and the DC terminal to a wall (page 15).
15 Introduction and Installation To attach the AC adaptor and the DC terminal to a wall By placing the AC adaptor and the DC terminal in the case and mounting the case to the wall, you can protect the AC adaptor and the DC terminal from tampering and exposure. 1Attach the rear part of the case to a wall using the wood screws (4 mm x 16 mm,3/16″ x 5/8″). Note: • Disconnect the DC cord from the clamp on the rear of the DC terminal beforehand. See step 9 on page 14 for details. • Take out the cardboard and wood screws from the AC case beforehand. Wood screwsCase 83.5 mm ( 3 5/16″) Wall 2Pack the AC adaptor and DC terminal as shown. Pack the AC adaptor in the rear case. •Be sure to run the power cord through the power cord hole. Pack the DC cord in the rear case. • Be sure to bundle the DC cord so that it will not touch the bottom of the case. Pack the DC terminal in the rear case. •Be sure to run the wires through the wire hole, then under the wire rib. Wire rib Wire hole DC terminal Power cord holePower cord AC adaptor DC cord 3Attach the front of the case.
16 To attach the wires •Strip off of the wire cover so that about 9 mm ( 3/8″) of the wire is exposed. •While pressing on the button with a pointed object such as a screwdriver, insert the wire into the terminal connector. •To disconnect a wire, press on the button while pulling out. Introduction and Installation Note: • To open the case again, push the bottom of the front case, then release from the rear case. To attach the power cable •While pressing on the button hard with a pointed object such as a screwdriver, insert the power cable into the terminal connector. •To disconnect the power cable, press on the button hard while pulling out. •To attach an optional power cable, cut off about 12 mm ( 1/2″) of the cable cover ( ), then push in firmly until the end of the cable is securely inserted into the power connection terminal ( ). Sub Monitor station Button Terminal connector Button Terminal connector Power cable cross section Correct Incorrect DC terminal
17 Important information: •Do not use anything containing alcohol, polish powder, powder soap, benzine, thinner, wax, petroleum, or boiling water. Also do not spray with insecticide, glass cleaner, or hair spray. This could cause a change in color or quality. Clean the unit with a soft, dry cloth when cleaning. For excessive dirt, wipe the unit with a slightly damp cloth. Cleaning Help
18 Technical data about this product General Information Sub Monitor station Power supply: Current consumption: Dimensions: Mass (Weight): Operating environment: Installation method: External material:24 V DC Standby: Approximately 38 mA At operation: Approximately 210 mA Approximately height 145 mm x width 165 mm x depth 44 mm (5 3/4″ x 6 1/2″ x 1 3/4″) Approximately 600 g (1.32 lb.) 0 °C to 40 °C (32 °F to 104 °F), Up to 90 % RH (Relative Humidity) non condensing Exposure mount Flush mount (Optional Flush mount unit is required.) Flame retardant ABS resin (panel: acrylic resin) Note: •Design and specifications are subject to change without notice. •The pictures and illustrations in these instructions may vary slightly from the actual product. AC adaptor (Part number: PFAP1014) Power supply: Output voltage: Output current: Dimensions: Mass (Weight): Operating environment:100 V – 240 V AC , 50 Hz / 60 Hz 24 V DC 2 A Approximately height 120 mm x width 60 mm x depth 35 mm (4 3/4″ x 2 3/8″ x 1 3/8″) Approximately 310 g (0.68 lb.) 0 °C to 40 °C (32 °F to 104 °F), Up to 90 % RH (Relative Humidity) non condensing Note: •To connect to a chime, make sure the chime is: – Normal open (Low active) – Less than 30 V AC (1 A), 24 V DC (1 A)
For your future reference Date of purchase Serial number (found on the rear of the unit) Dealer’s name and address Dealer’s telephone number Attach your sales receipt here. LHQT0198 S0405-0 Printed in INDONESIA Panasonic Consumer Electronics Company, Division of Panasonic Corporation of North America One Panasonic Way, Secaucus, New Jersey 07094, U.S.A. Panasonic Puerto Rico, Inc. San Gabriel Industrial Park, Ave. 65 de Infantería, Km. 9.5, Carolina, Puerto Rico 00985, U.S.A. Copyright: •This material is copyrighted by Panasonic Communications Co., Ltd., and may be reproduced for internal use only. All other reproduction, in whole or in part, is prohibited without the written consent of Panasonic Communications Co., Ltd. © 2005 Panasonic Communications Co., Ltd. All Rights Reserved.