Home > Panasonic > Integrated Telephone System > Panasonic Sub Monitor Station Video Intercom System Vl Gm001a Installation And Operation Guide

Panasonic Sub Monitor Station Video Intercom System Vl Gm001a Installation And Operation Guide

    Download as PDF Print this page Share this page

    Have a look at the manual Panasonic Sub Monitor Station Video Intercom System Vl Gm001a Installation And Operation Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							Sub Monitor Station
     Installation and Operation Guide
    Model No. VL-GM001A
    Thank you for purchasing a Panasonic Sub Monitor Station.
    Please read this Installation and Operation Guide before using the unit and
    save for future reference.
    Video Intercom System 
    						
    							2
    Important Information
    Important Information
    FCC and Other Information ....................................................................................... 2
    Important safety instructions ..................................................................................... 3
    Additional safety information ..................................................................................... 4
    For best performance ................................................................................................ 5
    Introduction and Installation
    Included items ............................................................................................................ 6
    Location of controls ................................................................................................... 7
    Before installation ...................................................................................................... 8
    Installing the sub monitor station ............................................................................. 10
    Help
    Cleaning ................................................................................................................... 17
    General Information
    Technical data about this product ............................................................................ 18
    NOTE:
    This equipment has been tested and found to comply with the limits for a Class B digital device,
    pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
    protection against harmful interference in a residential installation. This equipment generates,
    uses, and can radiate radio frequency energy and, if not installed and used in accordance with
    the instructions, may cause harmful interference to radio communications.
    However, there is no guarantee that interference will not occur in a particular installation.
    If this equipment does cause harmful interference to radio or television reception, which can be
    determined by turning the equipment off and on, the user is encouraged to try to correct the
    interference by one or more of the following measures:
    •Reorient or relocate the receiving antenna.
    •Increase the separation between the equipment and receiver.
    •Connect the equipment into an outlet on a circuit different from that to which the receiver is
    connected.
    •Consult the dealer or an experienced radio/TV technician for help. This device complies with Part 15 of the FCC Rules. Operation is subject to the following
    two conditions:
    (1) This device may not cause harmful interference.
    (2) This device must accept any interference received, including interference that may cause
    undesired operation.
    FCC and Other Information
    CAUTION:
    Any changes or modifications not expressly approved by the party responsible for compliance
    could void the user’s authority to operate this equipment. 
    						
    							3
    CAUTION
    RISK OF ELECTRIC SHOCK
    DO NOT OPEN
    The lightning flash with arrow
    head within a triangle is
    intended to tell the user that
    parts inside the product are a
    risk of electric shock to persons.The exclamation point within a
    triangle is intended to tell the
    user that important operating and
    servicing instructions are in the
    papers with the appliance.
    Important safety instructions
    1) Read these instructions.
    All the safety and operating instructions
    should be read before the appliance is
    operated.
    2) Keep these instructions.
    The safety and operating instructions
    should be retained for future reference.
    3) Heed all warnings.
    All warnings on the appliance and in the
    operating instructions should be adhered to.
    4) Follow all instructions.
    All operating and use instructions should
    be followed.
    5) Do not use this apparatus near water.
    For example, near a bathtub, wash bowl,
    kitchen sink, or laundry tub, in a wet
    basement, or near a swimming pool, and
    the like.
    6) Clean only with dry cloth.
    Do not use liquid cleaners or aerosol
    cleaners. Use a dry cloth for cleaning.
    7) Do not block any ventilation openings.
    Install in accordance with the
    manufacturer’s instructions.
    Slots and Openings in the cabinet are
    provided for ventilation and to ensure
    reliable operation of the product and to
    protect it from overheating. The openings
    should never be blocked by placing
     the
    product on a bed, sofa, rug, or other
    similar surface.
    8) Do not install near any heat sources such
    as radiators, heat registers, stoves, or
    other apparatus (including amplifiers) that
    produce heat.
    This product should not be placed in a
    built-in installation such as a bookcase or
    rack unless proper ventilation is provided
    or the manufacturer’s instructions have
    been
     adhered to.9) Do not defeat the safety purpose of the
    polarized or grounding-type plug.
    A polarized plug has two blades with one
    wider than the other. A grounding type
    plug has two blades and a third grounding
    prong. The wide blade or the third prong
    are provided for your safety. If the
    provided plug does not fit into your outlet,
    consult an electrician for replacement of
    the obsolete outlet.
    10) Protect the power cord from being walked
    on or pinched particularly at plugs,
    convenience receptacles, and the point
    where they exit from the apparatus.
    11) Only use attachments / accessories
    specified by the manufacturer.
    12) Unplug this apparatus during lightning
    storms or when unused for long periods of
           time.       This will prevent damage to the product
    due to lightning and power-line surges.
    13) Refer all servicing to qualified service
    personnel. Servicing is required when the
    apparatus has been damaged in any way,
    such as power- supply cord or plug is
    damaged, liquid has been spilled or
    objects have fallen into the apparatus, the
    apparatus has been exposed to rain or
    moisture, does not operate normally, or
    has been dropped.
    Important Information
    SAVE THESE INSTRUCTIONS 
    						
    							4
    Important Information
    Additional safety information
    1. Use only the power source marked on the unit. If you are not sure of the type of
    power supplied to your home, consult your dealer or local power company.
    2. Use only the specified AC adaptor.
    3. Do not tamper with the plug.
    4. Make sure the plug is securely inserted.
    5. Do not touch the plug with wet hands.
    6. Do not place objects on the power cord. Install the unit where no one can step or trip
    on  the cord.
    7. To reduce the risk of electric shock, do not disassemble this unit. Take the unit to an
    authorized service center when service is required. Opening or removing covers
    may expose you to dangerous voltages or other risks. Incorrect reassembly can
    cause electric shock when the unit is subsequently used.
    8. Unplug this unit from power outlets and refer servicing to an authorized service
    center when the following conditions occur:
    A. If smoke rises, or an unaccustomed noise or smell is discharged from the unit.
    B. If metal objects have been dropped inside the sub monitor station.
    9. Do not put your ear(s) near the speaker, as loud sounds emitted from the speaker
    may cause hearing impairment.
    10. Only a qualified technician is allowed to connect a power cable to the unit.
    Contact an authorized service center.
    11. Do not make any wiring connections when the power supply is turned on.
    12. Never install wiring during a lightning storm.
    13. Do not connect a power cable other than the specified voltage.
    14. Do not connect the power cable to any terminal other than the one specified.
    15. When existing chime wires are used, it is possible that they contain AC voltage.
    Electric shock or unit damage could result. Contact an authorized service center.
    16. Never touch the inside of the sub monitor station. High voltage is present.
    17. Make certain when mounting the unit to any wall surface that the method used will
    hold the weight of the unit properly.
    18. If the wiring is outdoors, use a protection tube or a surge protector.
    19. If the wiring is underground, do not make any connections underground.
    20. WARNING – To Reduce The Risk Of Fire Or Electric Shock, Do Not Expose This
    Apparatus To Rain Or Moisture.
    21. WARNING – Unplug this unit from power outlets if it emits smoke, an abnormal
    smell or makes unusual noise. These conditions can cause fire or electric shock.
    Confirm that smoke has stopped and contact an authorized service center.
    Note:
    •
    This product has a fluorescent lamp that contains a small amount of mercury. It also contains
    lead in some components. Disposal of these materials may be regulated in your community
    due to environmental considerations. For disposal or recycling information please contact
    your local authorities, or the Electronics Industries Alliance:  
    						
    							5
    Important Information
    For best performance
    •If a power failure occurs, the unit will not function.
    •Do not place any object within 20 cm (8 inches) of the sub monitor station. This may
    cause communication errors or malfunction. 
    						
    							6
    Included items
    No. Item Notes
    Wood screws
    AC adaptor4
    1For the sub monitor station.
    4 mm x 35 mm (
    3/16″ x 13/8″) Sub Monitor station
    1 ------
    Power cord 1 ------
    Power cable
    1Enclosed in the AC adaptor case.
    Wood screws 2
    ------
    For the AC adaptor case.
    4 mm x 16 mm (3/16″ x 5/8″)
    Introduction and Installation
    Sub Monitor Station:
    A Sub Monitor Station is an optional unit which, when used through the Monitor
    Station, operates just like the Monitor Station. Up to two of these units can be
    connected to the system.Quantity 
    						
    							7
    Location of controls
    Front view
     Display (3.5-inch color LCD screen)
     Microphone
    • Speak into the microphone when talking to a visitor.
    SELECT () button / BRIGHT button
     SELECT () button / RECEIVE VOLUME button
     MENU button / PRESS TALK button
     MONITOR button
    • Allows you to monitor the sound and camera image from the door station.
     DOOR button
    • Allows you to open the door.
     TALK button
    • To answer a door call and/or speak to the visitor.
     CALL button
    • To call another monitor unit.
     Speaker
    * Ventilation holes are located at the bottom. (Do not cover these.)
    Introduction and Installation 
    						
    							8
    Before installation
    Introduction and Installation
    To avoid malfunction or communication disturbance, do not install the sub monitor
    station in the following locations:
    – Places where vibration or any other kind of impact occurs.
    – Places where echoing is frequent.
    – Places where a high concentration of dust, hydrogen sulfide, phosphorus,
    ammonia, sulfur, carbon, acid, or noxious fumes occur.
    – Within 2 m (6′7″) of a TV, microwave, personal computer, air conditioner or any
    other electrical device.
    The sub monitor station and AC adaptor are for indoor use only.
    Do not use it outdoors, otherwise it may malfunction.
    •Use the flush mount unit (sold separately) when installing the sub monitor station
    into a wall.
    – Refer to the Installation and Operation Guide that is included with the flush
    mount unit for details on installing the flush mount unit.
    Standard installation position of the sub monitor station
    Place the sub monitor station in a location so that your eyes are the same height as
    the center of the display.
    Note:
    •In areas surrounded by high electrical field, disturbance may occur in the sub
    monitor station’s image or sound.
    •Be sure to install the sub monitor station more than 5 m (16′5″) away from the
    door station.
    •Please check that there is a partition of a wall etc. between a monitor station and
    sub monitor station and attach them.
    •Do not place any objects within 20 cm (8 inches) of the sub monitor station. This
    may cause communication errors or malfunction.
    •Do not install the sub monitor station inside a wall, without using the flush mount
    unit. 
    						
    							9
    Power cable/wire type and distance
    •Power cable (between the sub monitor station and the AC adaptor):
    Type: ø1.2 Fire alarm cable 16 AWG
    Distance: Maximum 30 m (about 98 feet)
    •Wire (between the monitor station and the last sub monitor station):
    Type: General cable CAT-3 24 AWG
    Distance: Maximum 100 m (about 328 feet)
    Chime
    Sub Monitor station
    VL-GM001A
    H11
    H12
    H21
    H22
    K1
    K2
    120 V ACAC adaptor
    Connect to terminals
    H21 and H22 of the
    sub monitor station.
    NOTE:
    •This chime wiring schematic diagram is only an example.
    Refer to the wiring instruction provided with your chime for detail.
    •Refer to the technical data on page 18 when connecting to a chime.
    •All connections are non polar. Connect to terminals
    H11 and H12 of the
    monitor station.
    Introduction and Installation
    Wiring schematic diagram
    All monitor stations and sub monitor stations should be connected by daisy chain
    wiring method.
    The connection of 2nd sub monitor station (the last end terminal) and monitor station
    is NOT required. 
    						
    							10
    Installing the sub monitor station
    1Remove the sub monitor station from the box, and then remove the padding
    material from between the front case and the bottom case.
    •The front case and the bottom case are not joined together, so be careful not
    to drop them when taking them out of the box.
    Bottom case
    Front casePadding material
    Connector
    2Remove the terminal cover.
    Bottom case
    Terminal cover
    Introduction and Installation 
    						
    All Panasonic manuals Comments (0)

    Related Manuals for Panasonic Sub Monitor Station Video Intercom System Vl Gm001a Installation And Operation Guide