Have a look at the manual Panasonic Sub Monitor Station Video Intercom System Vl Gm001a Installation And Operation Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Sub Monitor Station Installation and Operation Guide Model No. VL-GM001A Thank you for purchasing a Panasonic Sub Monitor Station. Please read this Installation and Operation Guide before using the unit and save for future reference. Video Intercom System
2 Important Information Important Information FCC and Other Information ....................................................................................... 2 Important safety instructions ..................................................................................... 3 Additional safety information ..................................................................................... 4 For best performance ................................................................................................ 5 Introduction and Installation Included items ............................................................................................................ 6 Location of controls ................................................................................................... 7 Before installation ...................................................................................................... 8 Installing the sub monitor station ............................................................................. 10 Help Cleaning ................................................................................................................... 17 General Information Technical data about this product ............................................................................ 18 NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: •Reorient or relocate the receiving antenna. •Increase the separation between the equipment and receiver. •Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. •Consult the dealer or an experienced radio/TV technician for help. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation. FCC and Other Information CAUTION: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.
3 CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN The lightning flash with arrow head within a triangle is intended to tell the user that parts inside the product are a risk of electric shock to persons.The exclamation point within a triangle is intended to tell the user that important operating and servicing instructions are in the papers with the appliance. Important safety instructions 1) Read these instructions. All the safety and operating instructions should be read before the appliance is operated. 2) Keep these instructions. The safety and operating instructions should be retained for future reference. 3) Heed all warnings. All warnings on the appliance and in the operating instructions should be adhered to. 4) Follow all instructions. All operating and use instructions should be followed. 5) Do not use this apparatus near water. For example, near a bathtub, wash bowl, kitchen sink, or laundry tub, in a wet basement, or near a swimming pool, and the like. 6) Clean only with dry cloth. Do not use liquid cleaners or aerosol cleaners. Use a dry cloth for cleaning. 7) Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. Slots and Openings in the cabinet are provided for ventilation and to ensure reliable operation of the product and to protect it from overheating. The openings should never be blocked by placing the product on a bed, sofa, rug, or other similar surface. 8) Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. This product should not be placed in a built-in installation such as a bookcase or rack unless proper ventilation is provided or the manufacturer’s instructions have been adhered to.9) Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. 10) Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus. 11) Only use attachments / accessories specified by the manufacturer. 12) Unplug this apparatus during lightning storms or when unused for long periods of time. This will prevent damage to the product due to lightning and power-line surges. 13) Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power- supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped. Important Information SAVE THESE INSTRUCTIONS
4 Important Information Additional safety information 1. Use only the power source marked on the unit. If you are not sure of the type of power supplied to your home, consult your dealer or local power company. 2. Use only the specified AC adaptor. 3. Do not tamper with the plug. 4. Make sure the plug is securely inserted. 5. Do not touch the plug with wet hands. 6. Do not place objects on the power cord. Install the unit where no one can step or trip on the cord. 7. To reduce the risk of electric shock, do not disassemble this unit. Take the unit to an authorized service center when service is required. Opening or removing covers may expose you to dangerous voltages or other risks. Incorrect reassembly can cause electric shock when the unit is subsequently used. 8. Unplug this unit from power outlets and refer servicing to an authorized service center when the following conditions occur: A. If smoke rises, or an unaccustomed noise or smell is discharged from the unit. B. If metal objects have been dropped inside the sub monitor station. 9. Do not put your ear(s) near the speaker, as loud sounds emitted from the speaker may cause hearing impairment. 10. Only a qualified technician is allowed to connect a power cable to the unit. Contact an authorized service center. 11. Do not make any wiring connections when the power supply is turned on. 12. Never install wiring during a lightning storm. 13. Do not connect a power cable other than the specified voltage. 14. Do not connect the power cable to any terminal other than the one specified. 15. When existing chime wires are used, it is possible that they contain AC voltage. Electric shock or unit damage could result. Contact an authorized service center. 16. Never touch the inside of the sub monitor station. High voltage is present. 17. Make certain when mounting the unit to any wall surface that the method used will hold the weight of the unit properly. 18. If the wiring is outdoors, use a protection tube or a surge protector. 19. If the wiring is underground, do not make any connections underground. 20. WARNING – To Reduce The Risk Of Fire Or Electric Shock, Do Not Expose This Apparatus To Rain Or Moisture. 21. WARNING – Unplug this unit from power outlets if it emits smoke, an abnormal smell or makes unusual noise. These conditions can cause fire or electric shock. Confirm that smoke has stopped and contact an authorized service center. Note: • This product has a fluorescent lamp that contains a small amount of mercury. It also contains lead in some components. Disposal of these materials may be regulated in your community due to environmental considerations. For disposal or recycling information please contact your local authorities, or the Electronics Industries Alliance:
5 Important Information For best performance •If a power failure occurs, the unit will not function. •Do not place any object within 20 cm (8 inches) of the sub monitor station. This may cause communication errors or malfunction.
6 Included items No. Item Notes Wood screws AC adaptor4 1For the sub monitor station. 4 mm x 35 mm ( 3/16″ x 13/8″) Sub Monitor station 1 ------ Power cord 1 ------ Power cable 1Enclosed in the AC adaptor case. Wood screws 2 ------ For the AC adaptor case. 4 mm x 16 mm (3/16″ x 5/8″) Introduction and Installation Sub Monitor Station: A Sub Monitor Station is an optional unit which, when used through the Monitor Station, operates just like the Monitor Station. Up to two of these units can be connected to the system.Quantity
7 Location of controls Front view Display (3.5-inch color LCD screen) Microphone • Speak into the microphone when talking to a visitor. SELECT () button / BRIGHT button SELECT () button / RECEIVE VOLUME button MENU button / PRESS TALK button MONITOR button • Allows you to monitor the sound and camera image from the door station. DOOR button • Allows you to open the door. TALK button • To answer a door call and/or speak to the visitor. CALL button • To call another monitor unit. Speaker * Ventilation holes are located at the bottom. (Do not cover these.) Introduction and Installation
8 Before installation Introduction and Installation To avoid malfunction or communication disturbance, do not install the sub monitor station in the following locations: – Places where vibration or any other kind of impact occurs. – Places where echoing is frequent. – Places where a high concentration of dust, hydrogen sulfide, phosphorus, ammonia, sulfur, carbon, acid, or noxious fumes occur. – Within 2 m (6′7″) of a TV, microwave, personal computer, air conditioner or any other electrical device. The sub monitor station and AC adaptor are for indoor use only. Do not use it outdoors, otherwise it may malfunction. •Use the flush mount unit (sold separately) when installing the sub monitor station into a wall. – Refer to the Installation and Operation Guide that is included with the flush mount unit for details on installing the flush mount unit. Standard installation position of the sub monitor station Place the sub monitor station in a location so that your eyes are the same height as the center of the display. Note: •In areas surrounded by high electrical field, disturbance may occur in the sub monitor station’s image or sound. •Be sure to install the sub monitor station more than 5 m (16′5″) away from the door station. •Please check that there is a partition of a wall etc. between a monitor station and sub monitor station and attach them. •Do not place any objects within 20 cm (8 inches) of the sub monitor station. This may cause communication errors or malfunction. •Do not install the sub monitor station inside a wall, without using the flush mount unit.
9 Power cable/wire type and distance •Power cable (between the sub monitor station and the AC adaptor): Type: ø1.2 Fire alarm cable 16 AWG Distance: Maximum 30 m (about 98 feet) •Wire (between the monitor station and the last sub monitor station): Type: General cable CAT-3 24 AWG Distance: Maximum 100 m (about 328 feet) Chime Sub Monitor station VL-GM001A H11 H12 H21 H22 K1 K2 120 V ACAC adaptor Connect to terminals H21 and H22 of the sub monitor station. NOTE: •This chime wiring schematic diagram is only an example. Refer to the wiring instruction provided with your chime for detail. •Refer to the technical data on page 18 when connecting to a chime. •All connections are non polar. Connect to terminals H11 and H12 of the monitor station. Introduction and Installation Wiring schematic diagram All monitor stations and sub monitor stations should be connected by daisy chain wiring method. The connection of 2nd sub monitor station (the last end terminal) and monitor station is NOT required.
10 Installing the sub monitor station 1Remove the sub monitor station from the box, and then remove the padding material from between the front case and the bottom case. •The front case and the bottom case are not joined together, so be careful not to drop them when taking them out of the box. Bottom case Front casePadding material Connector 2Remove the terminal cover. Bottom case Terminal cover Introduction and Installation