- 10 (E) - ENGLISH Connections Convertible camera:AW-E50, AW-E650, AW-E655, AW-E750, AW-E860, etc. Viewfinder: WV-VF65B, AW-VF80, AW-VF64, etc. Remote operation panel: AW-CB400, etc. Video monitor SDI monitor Use the control cable (AW-CA50T8G) to connect the remote operation panel to the convertible camera. Use the AW-PS505A AC adapter, which is an optional accessory, for the power supply. Inter-communication between the remote operation panel and studio SDI card is not possible. When configuring a system with the remote operation panel Viewfinder:WV-VF65B, AW-VF80, AW-VF64, etc. Convertible camera: AW-E50, AW-E650, AW-E655, AW-E750, AW-E860, etc.SDI monitor Video monitor SDI output Remote operation panel:AW-CB400, etc. Control cable:AW-CA50T8G TALLY cable AC adapter:AW-PS505A AC adapter:AW-PS505A Cable provided with AC adapter 10BASE-T straight cable Cable provided with AC adapter Coaxial cable: BBC No. PSF1/M, BELDEN 881 or equivalent coaxial cable max. 00 m
- 11 (E) - Performing the settings 1 Display the main menu. When performing the settings with the convertible camera: Press the MENU switch continuously for at least 5 seconds. When performing the settings with the remote control unit (AW-RC600): Set the MENU switch to “ON”. Main menu for halogen light mode, fluorescent light mode and outdoor mode Main menu for user mode Convertible camera Remote control unit (AW-RC600) Setting and changing of menu items The mode selected is displayed here. To return to filming mode ( This is displayed when the convertible camera is used to perform the settings.) * “Option Card 2” is displayed on the menu when the optional card has been plugged into the optional card slot of the additional card box. MENU switch ITEM/AWC switchYES/ABC switch NO/BAR switch MENU switch DATA YES/UP switch ITEM UP switchITEM DOWN switch DATA NO/DOWN switch Camera settings to match the system configuration and filming conditions can be made using the menu screens. See the convertible camera operating instructions for more information on the settings. For details on the setting procedures when the remote control unit and re\ mote operation panel are used, refer to the operating instructions of the unit and panel.
- 1 (E) - ENGLISH 2 Select “Option Card 1” to display the submenu. When performing the settings with the convertible camera: Press the MENU or ITEM/AWC switch to move the flashing to the setting item, then press the YES/ABC switch to display the submenu. When performing the settings with the remote control unit (AW-RC600): Press the ITEM UP or ITEM DOWN switch to move the flashing to the setting item, then press the DATA YES/UP switch to display the submenu. 3 Select the setting item and change the setting. When performing the settings with the convertible camera: Press the MENU or ITEM/AWC switch to move the flashing to the desired setting item, then press the YES/ABC or NO/BAR switch to change the setting. When performing the settings with the remote control unit (AW-RC600): Press the ITEM UP or ITEM DOWN switch to move the flashing to the desired setting item, then press the DATA YES/UP or DATA NO/DOWN switch to change the setting. 4 Return to filming mode. When performing the settings with the convertible camera: Press the MENU or ITEM/AWC switch and select “End” on the main menu, then press the YES/ABC switch. When performing the settings with the remote control unit (AW-RC600): Set the MENU switch to “OFF”. After being returned to filming mode, the convertible camera will operate as per the changed settings. Setting and changing of menu items
- 1 (E) - Setting and changing of menu items Zebra indicator (ON, OFF) This sets the zebra pattern display which appears in the viewfinder. ON: Zebra patterns are displayed in the viewfinder. OFF: Zebra patterns are not displayed in the viewfinder. Even if “ON” is selected for this setting, the zebra patterns will not be displayed in the viewfinder if “CVBS” has been selected as the EVF output setting. Level (70% to 110%) The zebra patterns are displayed to use as a yardstick for the brightness level. These settings are available when “ON” has been selected for the Zebra indicator setting. Safety zone (1 to 4, OFF) This selects the type of safety zone that is displayed in the viewfinder. If “OFF” is selected, a safety zone will not be displayed. The safety zone and the center marker reflect the electrical positions which may differ from the optical positions. The inner frame and the outer frame are approximately 90% and 95%, respectively, of the safety zone. EVF output (Y, CVBS) This sets the signals to be output to the viewfinder. Y: Brightness signals are output to the viewfinder. CVBS: Color signals are output to the viewfinder. The zebra pattern is not displayed in the viewfinder when “CVBS” has been selected. Optional card settings submenu
- 14 (E) - ENGLISH 92 21.5 70 Appearance Unit: mmSDI card 111
- 15 (E) - 183 190 Appearance Unit: mmInterface bracket 14130 50
- 16 (E) - ENGLISH Specifications Ambient operating temperature: –10°C to +45°C Ambient operating humidity: 0% to 90% (without condensation) Dimensions (WHD): SDI card 1.5709 mm (excluding protrusions) Interface bracket 19018171 mm (excluding protrusions) Weight: SDI card 0.10 kg Interface bracket 1.06 kg Input/output connectors: SDI card SDI OUT 1, connector BNC, compliant with EBU Tech.67-E standard EVF I/F connector 10-pin, round Interface bracket EVF connector 1 10-pin, round, composite signals/brightness, 1.0 V [P-P] EVF connector 6-pin, round, composite signals/brightness, 1.0 V [P-P] Inter-communications jack M TALLY input connector BNC Switch/control functions: SDI card • EDH ENABLE/DISABLE • Model selection E50/E860 • DATA CLIP NORMAL/CLIP • NTSC/PAL switching NTSC/PAL Interface bracket EVF standby / VIDEO ON/OFF switch WV-VF65B, AW-VF80 ST.BY/ON AW-VF64 VIDEO ON/VIDEO OFF Inter-communications level control Menu screens Zebra indicator (ON/OFF) Level (70% to 110%) Safety zone (1///4/5/OFF) EVF output (Y/CVBS) Weight and dimensions indicated above are approximate. Specifications are subject to change without notice. Power requirements: DC 1 V (supplied from convertible camera) Power consumption: 15 W (When WV-VF65B, AW-VF80 is connected) indicates safety information.