Home > Panasonic > Camera Accessories > Panasonic Studio Sdi Card Aw Pb506al Operating Instructions

Panasonic Studio Sdi Card Aw Pb506al Operating Instructions

    Download as PDF Print this page Share this page

    Have a look at the manual Panasonic Studio Sdi Card Aw Pb506al Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							
    Printed in JapanGedruckt in JapanImprimé au JaponStampato in GiapponeImpreso en JapónНапечатано в Японии在日本印制
    VQTB0137 F0806Y1116 
    D
    Matsushita Electric Industrial Co., Ltd.
    Web Site: h t t p : / / p a n a s o n i c . n e t
    E
    FRANÇAIS
    DEUTSCH
    ENGLISH
    ITALIANO
    ESPAÑOL
    中  文
    РУССКИЙ
    Before attempting to connect, operate or adjust this product,  please read these instructions completely.
    Studio SDI Card
    AW-PB506AL
    This product consists of an SDI card and an 
    interface bracket.
    松下电器产业株式会社
    Web Site: h t t p : / / p a n a s o n i c . n e t 
    						
    							
    Safety precautions
     indicates safety information.
    WARNING:
    •  TO  REDUCE  THE  RISK  OF  FIRE  OR  SHOCK  HAZARD,  DO  NOT  EXPOSE 
    THIS EQUIPMENT TO RAIN OR MOISTURE.
    •   TO  REDUCE  THE  RISK  OF  FIRE  OR  SHOCK  HAZARD,  KEEP  THIS 
    EQUIPMENT  AWAY  FROM  ALL  LIQUIDS.  USE  AND  STORE  ONLY  IN 
    LOCATIONS  WHICH  ARE  NOT  EXPOSED  TO  THE  RISK  OF  DRIPPING  OR 
    SPLASHING  LIQUIDS,  AND  DO  NOT  PLACE  ANY  LIQUID  CONTAINERS  ON 
    TOP OF THE EQUIPMENT.
    CAUTION:
    TO  REDUCE  THE  RISK  OF  FIRE  OR  SHOCK  HAZARD  AND  ANNOYING 
    INTERFERENCE, USE THE RECOMMENDED ACCESSORIES ONLY.
    CAUTION:
    TO  REDUCE THE  RISK  OF  FIRE  OR  SHOCK  HAZARD,  REFER  CHANGES  OF 
    SWITCH SETTINGS INSIDE THE UNIT TO QUALIFIED SERVICE PERSONNEL.
       DO NOT REMOVE PANEL COVERS BY UNSCREWING.
        To reduce the risk of electric shock, do not remove the covers. No user serviceable 
    parts inside.
      Refer servicing to qualified service personnel.
    ENGLISH VERSION
    - 1 (E) -
        ........................................................................\
    .............................................................
        ........................................................................\
    .............................................................
        ........................................................................\
    .............................................................
        ........................................................................\
    .............................................................
        ........................................................................\
    .............................................................
        ........................................................................\
    .............................................................
        ........................................................................\
    .............................................................
        ........................................................................\
    .............................................................
        ........................................................................\
    .............................................................
        ........................................................................\
    .............................................................
        ........................................................................\
    .............................................................
        ........................................................................\
    .............................................................
        ........................................................................\
    .............................................................
        ........................................................................\
    .............................................................
        ........................................................................\
    .............................................................
        ........................................................................\
    .............................................................
        ........................................................................\
    .............................................................
        ........................................................................\
    .............................................................
        ........................................................................\
    .............................................................
    备忘录
    - 18 (C) -
    中  文 
    						
    							
    -  (E) -
    ENGLISHInformation on Disposal for Users of Waste Electrical & Electronic 
    Equipment (private households)
    This symbol on the products and/or accompanying documents means that used electrical and electronic products should not be mixed with general household waste.For proper treatment, recovery and recycling, please take these products to designated collection points, where they will be accepted on a free of charge basis. Alternatively, in some countries you may be able to return your products to your local retailer upon the purchase of an equivalent new product.Disposing of this product correctly will help to save valuable resources and prevent any potential negative effects on human health and the environment which could otherwise arise from inappropriate waste handling.Please contact your local authority for further details of your nearest designated collection point.Penalties may be applicable for incorrect disposal of this waste, in accordance with national legislation.
    For business users in the European Union
    If you wish to discard electrical and electronic equipment, please contact your dealer or supplier for further information.
    Information on Disposal in other Countries outside the European 
    Union
    This symbol is only valid in the European Union.If you wish to discard this product, please contact your local authorities or dealer and ask for the correct method of disposal. 
    						
    							
    -  (E) -
    
    Contents
    Configuration  ........................................ 3
    Accessories   .......................................... 3
    Introduction   ........................................... 4
    Characteristics   ...................................... 4
    Precautions for use   .............................. 4
    Major operating controls and  
    their functions   ................................. 5
     SDI card   ........................................... 5
     Interface bracket   .............................. 6
    Installing the SDI card   .......................... 7
    Interface bracket mountings   ............... 8
     Mounting the bracket on a tripod   ..... 8
     Mounting the camera   ....................... 8
     Mounting the viewfinder  
    on a bracket  .................................. 8
    Connections   .......................................... 9 
     When configuring a system  
    with the remote control unit   ......... 9
     When configuring a system  
    with the remote operation panel   ... 10
    Setting and changing of menu items   ... 11
     Performing the settings   .................. 11
     Optional card settings submenu   ....  1
    Appearance   ......................................... 14
     SDI card   ......................................... 14
     Interface bracket   ............................ 15
    Specifications   ..................................... 16
    Accessories
    Adjuster plug (M6  M3)   ........................ 1
    Screws (6 mm)   ....................................... 2
    Screws (8 mm)   ....................................... 4
    Configuration
    SDI card (AW-PB506A U01)   ................... 1
    Interface bracket (AW-PB506A U02)   .... 1 
    						
    							
    - 4 (E) -
    ENGLISH
    
    Characteristics
       Two signal outputs for SDI signals 
    compliant with the EBU Tech.67-E 
    standard (BBC No. PSF1/M, BELDEN 
    881 or equivalent coaxial cable; max. 
    00 m)
       EDH (Error Detection and Handling) 
    flags complying with the SMPTE RP165 
    standard can be added.  
    (  A switch can be used to enable or 
    disable the addition of these flags.)
        An inter-communications headset can be 
    used and its volume adjusted.
       The STANDBY/ON switch function of 
    the viewfinder (WV-VF65B, AW-VF80) is 
    incorporated.
        Output signals (brightness and 
    composite video signals) to the 
    viewfinder can be switched using the 
    menu settings.
        Zebra pattern and safety zone displays 
    appearing in the viewfinder can be 
    switched using the menu settings.
       The VIDEO ON/OFF switch function of 
    the viewfinder (AW-VF64) is incorporated. 
    (  In order to prevent CRT burn-in, the 
    AW-VF64 does not come with a standby 
    function.)
    Introduction
    Installing the SDI card in a convertible 
    camera (such as the AW-E50, AW-E650, 
     
    AW-E655, AW-E750 and AW-E860) and 
    mounting the camera on the interface 
    bracket makes it possible for a viewfinder 
    and/or inter-communications headset to 
    be used and thus enable the camera to 
    be used as a studio camera. In addition, 
    there are two signal outputs for SDI signals  
    compliant with EBU Tech.67-E standard.
    Notes
        The AW-PB506A cannot be installed 
    to the following models;  
    AW-E00, AW-E00A, AW-E00S, 
    AW-E600, AW-E800, AW-E800A, 
    AW-RP605, AW-PB605
        When the SDI card unit is to be 
    discarded at the end of its service 
    life, ask a specialized contractor 
    to dispose of it properly in order to 
    protect the environment.
        When connecting or disconnecting a 
    cable from any unit, ensure that the 
    power to that unit is turned off.
        Do not drop this product or subject it to 
    strong shock or vibration, as this may 
    cause it to malfunction.
        Avoid using the unit in very humid or 
    dusty locations, as this may cause it to 
    malfunction.
       Avoid using the product at a cold place 
    below –10°C or at a hot place above 
    +45°C because extremely low or high 
    temperature will adversely affect the 
    parts inside.
    Precautions for use 
    						
    							
    - 5 (E) -
    
    Major operating controls and their functions
    SDI card
     EVF I/F connector [EVF I/F]
    The EVF I/F cable 9 from the interface 
    bracket is connected here.
       SDI output 1, 2 connector  
    [SDI OUT 1, 2]
    SDI signals are output from here.
      Setting switches
    SW NOOFFON
    1EDHENABLEDISABLE
    SETTING E50E860
    DATA CLIPNORMALCLIP
    4NTSC/PALNTSCPAL
    1:   EDH 
     
    (Factory setting: ENABLE) 
    An EDH flag is added to SDI output at 
    the ENABLE setting. 2:  
    Model selection 
     
    (Factory setting: E50)
     
    When the AW-E50, AW-E650, 
     
    AW-E655 or AW-E750 is used, set 
    this switch at the E50. 
     
    When the AW-E860 is used, set this 
    switch at the E860. 
    3:   DATA CLIP 
     
    (Factory setting: NORMAL) 
    At the NORMAL setting, signal input 
    is output at the same level at which it 
    was input. 
    At the CLIP setting, signal input at 
    less than 0% is output at 0%, and 
    signal input at more than 100% is 
    clipped at 100%.
    4:   NTSC/PAL switching 
     
    (Factory setting: NTSC) 
    Leave this switch at the factory setting. 
    						
    							
    - 6 (E) -
    ENGLISH
    
    Major operating controls and their functions
    Interface bracket
     EVF connector 1 [EVF1]
    The viewfinder (WV-VF65B, AW-VF80) 
    is connected here.
    5  EVF connector 2 [EVF2]
    The viewfinder AW-VF64 is connected 
    here.
    Note
        Do not connect EVFs to EVF 
    connectors 1 and  (
     and 5) at 
    the same time.
    6   EVF standby / VIDEO ON/OFF 
    switch 
    [ST.BY / VIDEO ON/OFF]
    
    ST.BY:   Places the viewfinder in standby 
    mode.
    ON:   Outputs images to the viewfinder.
    
    VIDEO ON:    Outputs images to the 
    viewfinder.
    VIDEO OFF:  
     No images appear on the 
    viewfinder.
     
    The AW-VF64 does not come with a 
    standby function.
    7  Inter-communications level control 
    [LEVEL]
    This adjusts the sound level output to 
    the inter-communications headset.
    8   Inter-communications jack (M3) 
    [INCOM]
    The inter-communications headset is 
    connected here.
    If the plug diameter does not match, use 
    the adjuster plug (M6  M) supplied 
    with this product.
    MIC:     Dynamic (With Preamp)  
    50 /–0 dB
    Receiver:  150   (max. 00 mW)
    9  EVF I/F cable
    This is connected to the EVF I/F 
    connector  on the SDI card.
      TALLY input connector [TALLY IN]
    This is the tally control external input 
    connector.
    OPEN:  TALLY OFF
    SHORT:  
    TALLY ON
    When using the AW-CB400 remote 
    operation panel and AW-CA50T8G 
    control cable for connecting to the 
    convertible camera, connect the TALLY 
    cable of the AW-CA50T8G to this 
    connector. 
    						
    							
    - 7 (E) -
    
    Installing the SDI card
    Always ask your local dealer to install the SDI card.
    Rear panel
    Optional card slot cover
    4 screws (8 mm)2 screws (6 mm)
    SDI card
    1 Turn the power to the camera off 
    and remove any cables which are 
    connected to the power connector or 
    other connectors.
    2 Loosen the 4 screws (8 mm) on the 
    rear panel of the camera, then remove 
    the panel itself.
    3  Loosen the  screws (6 mm) on the optional card slot cover, then remove 
    the cover.
    4 Align the SDI card with the guides and 
    insert it. 
    Ensure the card is fully inserted.
    5 Firmly tighten the  screws (6 mm) to 
    the optional card slot.
    6 Firmly secure the rear panel with the  
    4 screws (8 mm).
    Note
       If the screws are misplaced, use 
    the extra screws supplied with this 
    product.
    Before installing the SDI card:
        Release the static carried in the body of the person to perform the installation. 
    Installation can be performed more safely if an anti-static wrist strap is worn. 
    Touching the card without first releasing this static may cause malfunctioning.
        Do not allow the metal part of the card come in contact with any other metal parts. 
    						
    							
    - 8 (E) -
    ENGLISH
    
     
    Mounting the bracket  
    on a tripod
    1 Mount the interface bracket on the 
    tripod. (Screw: 1/4 – 0UNC)
      Mounting the camera
    2 Mount the camera (in which the 
    SDI card has been installed) on the 
    interface bracket. 
    Fasten the fixing knob to firmly secure 
    the camera.
     
    Mounting the viewfinder  
    on a bracket
    3  Mount the mounting base that is 
    supplied to the viewfinder onto the top 
    of the interface bracket using the  
    screws provided.  
    (  Mount the base securely so that it is 
    not unsteady.)
    4  Slide the viewfinder onto the mounting 
    base and tighten the fixing knob to 
    secure it firmly.
    5 Connect the viewfinder cable to the 
    EVF connector 1 or  on the interface 
    bracket.
    6  Connect the EVF I/F cable from 
    the interface bracket to the EVF I/F 
    connector on the SDI card.
    Interface bracket mountings
    Fixing knob
    Fixing knob < 
    WV-VF65B, 
    AW-VF80, etc.>
    Fixing knob
    
    Mounting base
    2 screws 
    						
    							
    - 9 (E) -
    
    Connections
    Convertible camera:AW-E50, AW-E650, AW-E655, 
     
    AW-E750, AW-E860, etc.
    Viewfinder:
    WV-VF65B, AW-VF80, AW-VF64, etc.
    Remote control unit (RCU):
    WV-RC700A, WV-RC550, AW-RC600, 
    etc.
    Inter-communications headset
    Video monitor
    SDI monitor
        Use the RCU cable (AW-CA50A6) to 
    connect the remote control unit to the 
    convertible camera. 
    Power to the camera is supplied from the 
    remote control unit.
    Viewfinder:WV-VF65B, AW-VF80, AW-VF64, etc.
    Inter-communications headset
    Convertible camera:
    AW-E50, AW-E650, AW-E655, 
    AW-E750, AW-E860, etc.SDI monitor
    Video monitor
    SDI output
    Coaxial cable:BBC No. PSF1/M, BELDEN 
    881 or equivalent coaxial 
    cable max. 00 m
    Remote control unit (RCU): WV-RC700A, WV-RC550,  AW-RC600, etc.Composite signals
    Coaxial cable
    RCU cable:AW-CA50A6Inter-communications headset
    When configuring a system with the remote control unit 
    						
    All Panasonic manuals Comments (0)

    Related Manuals for Panasonic Studio Sdi Card Aw Pb506al Operating Instructions