- 11 - Connections Convertible camera: AW-E350, AW-E650, AW-E655, AW-E750, AW-E860, etc. Viewfinder: WV-VF65B, AW-VF80, AW-VF64, etc. Remote control unit (RCU): WV-RC700A, WV-RC550, AW-RC600, etc. Inter-communications headset Video monitor Use the RCU cable (AW-CA50A6) to connect the remote control unit to the convertible camera. Power to the camera is supplied from the remote control unit. Viewfinder:WV-VF65B, AW-VF80, AW-VF64, etc. Inter-communications headset Convertible camera:AW-E350, AW-E650, AW-E655, AW-E750, AW-E860, etc. Video monitor Remote control unit (RCU): WV-RC700A, WV-RC550, AW-RC600, etc.Composite signals Coaxial cable RCU cable: AW-CA50A6Inter-communications headset When configuring a system with the remote control unit
- 1 - Connections Convertible camera: AW-E350, AW-E650, AW-E655, AW-E750, AW-E860, etc. Viewfinder: WV-VF65B, AW-VF80, AW-VF64, etc. Remote operation panel: AW-CB400, etc. Video monitor Use the control cable (AW-CA50T8G) to connect the remote operation panel to the convertible camera. Use the AW-PS505A AC adapter, which is an optional accessory, for the power supply. Inter-communication between the remote operation panel and studio card is not possible. Viewfinder:WV-VF65B, AW-VF80, AW-VF64, etc. Convertible camera:AW-E350, AW-E650, AW-E655, AW-E750, AW-E860, etc. Video monitor Remote operation panel:AW-CB400, etc. Control cable:AW-CA50T8G TALLY cable AC adapter:AW-PS505A AC adapter:AW-PS505A Cable provided with AC adapter 10BASE-T straight cable Cable provided with AC adapter When configuring a system with the remote operation panel
- 13 - Performing the settings 1 Display the main menu. When performing the settings with the convertible camera: Press the MENU switch continuously for at least 5 seconds. When performing the settings with the remote control unit (AW-RC600): Set the MENU switch to “ON”. Main menu for halogen light mode, fluorescent light mode and outdoor mode Main menu for user mode Convertible camera Remote control unit (AW-RC600) Setting and changing of menu items * “Option Card 2” is displayed on the menu when the optional card has been plugged into the optional card slot of the additional card box. The mode selected is displayed here. To return to filming mode ( This is displayed when the convertible camera is used to perform the settings.) MENU switch ITEM/AWC switchYES/ABC switch NO/BAR switch MENU switch DATA YES/UP switch ITEM UP switchITEM DOWN switch DATA NO/DOWN switch Camera settings to match the system configuration and filming conditions can be made using the menu screens. See the convertible camera operating instructions for more information on the settings. For details on the setting procedures when the remote control unit and re\ mote operation panel are used, refer to the operating instructions of the unit and panel.
- 14 - 2 Select “Option Card 1” to display the submenu. When performing the settings with the convertible camera: Press the MENU or ITEM/AWC switch to move the flashing to the setting item, then press the YES/ABC switch to display the submenu. When performing the settings with the remote control unit (AW-RC600): Press the ITME UP or ITEM DOWN switch to move the flashing to the setting item, then press the DATA YES/UP switch to display the submenu. 3 Select the setting item and change the setting. When performing the settings with the convertible camera: Press the MENU or ITEM/AWC switch to move the flashing to the desired setting item, then press the YES/ABC or NO/BAR switch to change the setting. When performing the settings with the remote control unit (AW-RC600): Press the ITME UP or ITEM DOWN switch to move the flashing to the desired setting item, then press the DATA YES/UP or DATA NO/DOWN switch to change the setting. 4 Return to filming mode. When performing the settings with the convertible camera: Press the MENU or ITEM/AWC switch and select “End” on the main menu, then press the YES/ABC switch. When performing the settings with the remote control unit (AW-RC600): Set the MENU switch to “OFF”. After being returned to filming mode, the convertible camera will operate as per the changed settings. Setting and changing of menu items
- 15 - Setting and changing of menu items Zebra indicator (ON, OFF) This sets the zebra pattern display which appears in the viewfinder. ON : Zebra patterns are displayed in the viewfinder. OFF : Zebra patterns are not displayed in the viewfinder. Even if “ON” is selected for this setting, the zebra patterns will not be displayed in the viewfinder if “CVBS” has been selected as the EVF output 4 setting. 2 Level (70% to 110%) The zebra patterns are displayed to use as a yardstick for the brightness level. These settings are available when “ON” has been selected for the Zebra indicator setting. 3 Safety zone (1 to 4, OFF) This selects the type of safety zone that is displayed in the viewfinder. If “OFF” is selected, a safety zone will not be displayed. The safety zone and the center marker reflect the electrical positions which may differ from the optical positions. The inner frame and the outer frame are approximately 90% and 95%, respectively, of the safety zone. 4 EVF output (Y, CVBS) This sets the signals to be output to the viewfinder. Y : Brightness signals are output to the viewfinder. CVBS : Color signals are output to the viewfinder. The zebra pattern is not displayed in the viewfinder when “CVBS” has been selected. 234 Optional card settings submenu
- 16 - Appearance 3-9/16 (91) 7/8(21.5) 2-3/4 (70) Unit: inch (mm)Studio card 3-3/4 (96)
- 17 - 7-3/16 (183) 7-1/2 (190) Appearance Unit: inch (mm)Interface bracket 5-9/16 (141)1-3/16 (30) 2-1/16 (50)
- 18 - Specifications Ambient operating temperature: +14°F to +113°F (–10°C to +45°C) Ambient operating humidity: 30% to 90% (without condensation) Dimensions (WHD): Studio card 7/8”-3/4”3-9/16” (1.57091 mm) (excluding protrusions) Interface bracket 7-1/”7-3/16”6-3/4” (190183171 mm) (excluding protrusions) Weight: Studio card 0. lbs. (0.08 kg) Interface bracket .1 lbs. (0.94 kg) Input/output connector: Studio card EVF connector 6-pin, square Inter-communications jack M3 Interface bracket EVF connector 1 10-pin, round, composite signals/brightness, 1.0 V [P-P] EVF connector 6-pin, round, composite signals/brightness, 1.0 V [P-P] TALLY input connector BNC Switch/control functions: Studio card EVF standby / VIDEO ON/OFF switch WV-VF65B, AW-VF80 ST.BY/ON AW-VF64 VIDEO ON/VIDEO OFF Inter-communications level control Menu screens Zebra indicator (ON/OFF) Level (70% to 110%) Safety zone (1//3/4/5/OFF) EVF output (Y/CVBS) Weight and dimensions shown are approximate. Specifications are subject to change without notice. Source voltage: 1 V DC (supplied from convertible camera) Power consumption: 15 W (When WV-VF65B, AW-VF80 is connected) indicates safety information.
PANASONIC BROADCAST & TELEVISION SYSTEMS COMPANYUNIT COMPANY OF PANASONIC CORPORATION OF NORTH AMERICA Executive Office: One Panasonic Way 4E-7, Secaucus, NJ 07094 (01) 348-7000 EASTERN ZONE: One Panasonic Way 4E-7, Secaucus, NJ 07094 (01) 348-761 Southeast Region: 15 Northbrook Parkway, Ste 1-160, Suwanee, GA 3004 (770) 338-6835 Central Region: 1707 N Randall Road E1-C-1, Elgin, IL 6013 (847) 468-500 WESTERN ZONE: 3330 Cahuenga Blvd W., Los Angeles, CA 90068 (33) 436-3500 Government Marketing Department: 5 West Gude Drive, Rockville, MD 0850 (301) 738-3840 Broadcast PARTS INFORMATION & ORDERING: 9:00 a.m. – 5:00 p.m. (PST) (800) 334-4881/4 Hr. Fax (800) 334-4880 Emergency after hour parts orders (800) 334-4881 TECHNICAL SUPPORT: Emergency 4 Hour Service (800) -0741 Panasonic Canada Inc. 5770 Ambler Drive, Mississauga, Ontario L4W T3 (905) 64-5010 Panasonic de Mexico S.A. de C.V. Av angel Urraza Num. 109 Col. de Valle 03100 Mexico, D.F. (5) 1 951 17 Panasonic Puerto Rico Inc.San Gabriel Industrial Park, 65th Infantry Ave., Km. 9.5, Carolina, Puerto Rico 00630 (787) 750-4300 © 006 Matsushita Electric Industrial Co., Ltd. All rights reserved.