SDI Card AW-PB504N Before attempting to connect, operate or adjust this product, please read these instructions completely. Printed in Japan F1103S0 VQT0H53D
-2- CAUTION RISK OF ELECTRIC SHOCKDO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER SERVICEABLE PARTS INSIDE. REFER TO SERVICING TO QUALIFIED SERVICE PERSONNEL. The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (service) instructions in the literature accompanying the appliance. WARNING: TO REDUCE THE RISK OF FIRE OR SHOCK HAZARD, DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE. CAUTION: TO REDUCE THE RISK OF FIRE OR SHOCK HAZARD AND ANNOYING INTERFERENCE, USE THE RECOMMENDED ACCESSORIES ONLY. indicates safety information. FCC Note: This device complies with Part 15 of the FCC Rules. To assure continued compliance follow the attached installation instructions and do not make any unauthorized modifications. This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la class A est conforme à la norme NMB-003 du Canada. For CANADA CAUTION: TO REDUCE THE RISK OF FIRE OR SHOCK HAZARD, REFER MOUNTING OF THE OPTIONAL INTERFACE BOARD TO QUALIFIED SERVICE PERSONNEL.
-3- CONTENTS WARNING/CAUTION FOR SAFETY ........................................................................\ .............. 4 PREFACE ................................................................\ .............................................................. 5 PRECAUTIONS ............................................................\ ....................................................... .. 5 MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS ............................................... 6 MOUNTING ...............................................................\ ....................................................... ..... 7 CONNECTION .............................................................\ ....................................................... ... 9 APPEARANCE .............................................................\ ....................................................... ... 10 SPECIFICATIONS .........................................................\ ....................................................... .. 11 STANDARD ACCESORIES ........................................................................\ ............................ 11
-4- WARNING/CAUTION FOR SAFETY WARNING • Refer all servicing to qualified personnelTo reduce the risk of electric shock, dont remove cover or back, unless you are a qualified personnel. Refer all mountings, connections, servicing to qualified service personnel. • No water or moisture inside Do not let water or moisture into the product, or expose it to moisture, to prevent a fire and electric shock. • If you see smoke or smell an odor from the product, if water or other foreign matter gets inside, if it is damaged by dropping, or if you find anything wrong with it, immediately stop using it. • Do not disassemble or modify the product to prevent a fire and electric shock. CAUTION • Do not drop the product, do not expose it to strong shock, or do not step on it, to prevent a fire and injuries. • Do not install the product at a place full of moisture and dust, which may cause a fire and electric shock.
-5- • Installing this SDI card in a convertible camera suchas the AW-E350, AW-E650, AW-E655, AW-E750 makes it possible to output images from the camera as 270 Mbps (compliant with SMPTE259M standard) serial digital component signals. (BELDEN 8281 or equivalent coaxial cable; max. 200 m) • EDH (Error Detection and Handling) flags complying with the SMPTE RP165 standard can be added. (A switch can be used to enable or disable the addition of these flags.)• Zoom focus control of lenses equipped with aremote control function possible from a WV-CB550 (or similar) control box. PREFACE PRECAUTIONS • Power Off Before Connecting or DisconnectingCables Before plugging or unplugging the cables, be sure to switch power off. • Handle Carefully. Do not drop the product, or subject it to strong shock or vibration. This is important to prevent trouble.• Avoid Humidity and Dust.Avoid using the product at a humid, dusty place because much humidity and dust will cause damage to the parts inside. • Operating Temperature Range Avoid using the product at a cold place below –10°C or at a hot place above +45°C because extremely low or high temperature will adversely affect the parts inside.The AW-PB504 cannot be installed to the following models; AW-E300, AW-300A, AW-E300S, AW-E600, AW-E800, AW-E800A, AW-RP605, AW-PB605 CAUTION
-6- MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS ZOOM/FOCUS SDI OUT 1 SDI OU T 2 1 ZOOM/FOCUS connector This is the standard input connector for the lenses equipped with a remote control function for zoom focus. When using a Panasonic pan/tilt head (such as the AW-PH300A, AW-PH350), use the LENS I/F connector on the pan/tilt head instead of this connector. 2 SDI output connector [SDI OUT1, 2] Serial digital component signal can be output. 3 Setting switches 1: EDH (Factory setting: ENABLE) An EDH flag is added to SDI output at the ENABLE setting. 2: Model selection (Factory setting: CAMERA) Select the type of device to be used. 3: DATA CLIP (Factory setting: NORMAL) At the NORMAL setting, signal input is output at the same level at which it was input. At the CLIP setting, signal input at smaller then 0% is output at 0%, and signal input at more than 100% is clipped at 100%. 4: NTSC/PAL switching (Factory setting: NTSC) Leave this switch at the factory setting. 1 2 3 4O NSW NO OFF ON1 EDH ENABLE DISABLE2 SETTING CAMERA EX5003 DATA CLIP NORMAL CLIP 4 NTSC/PAL NTSC PAL
-7- MOUNTING • Be sure to ask your store, where you purchasedthe product, for mounting. • Disconnect the camera power connector before mounting. • Before handling the card, touch a metal part of the camera to discharge the static from the human body. An anti-static wrist strap is recommended for added safety. If you touch the card while you are still charged with static, it may cause trouble. • Keep the metal parts of the card free of contact with other metal parts. (1) Switch the camera off, and disconnect the power connector and other cables from the camera. (2) Loosen the four screws on the rear of the camera and remove the rear panel. (3) Loosen the two screws for the option card slot and remove the cover. (4) Insert the SDI card along the guide rail at the bottom of the camera and the tab above. Insert it securely all the way. (5) Tighten the two card setscrews securely. If you have lost the screws, use the screws (6 mm long) supplied as accessories. (6) Fasten the rear panel with the four screws. If you have lost the screws, use the screws (8 mm long) supplied as accessories. (7) Plug the cables back as necessary, connect the power connector, then switch power on.CAUTION
-8- Rear panelCard setscrews (6 mm)Rear panel setscrews (8 mm) SDI card Option card slot cover
-9- DC12V IN G/L IN VIDEO OUT CONTROL IN/OUT VIDEO IN G/L OUT CAMERAMONITOR VIDEO OUT G/L IN I/F REMOTE OPTION CARD IRIS DC12V IN MENUITEM/AWCYES/ABCNO/BAR ONPOWEROFFPOWERO I FUSE(POWER)FUSEFUSEAC Adaptor AW-PS505 SDI OUT 1 ZOOM/FOCUS SDI OUT 2 Convertible Camera AW –E600 • Before cable connection, switch power off. • Use the AC adaptor AW-PS505 for power supply. Use the power cable AW-CA4T1. • For details on connecting individual devices, refer to the respective op\ erating instructions. • For details on operating individual devices, refer to the respective ope\ rating instructions. In case of using a remote control box (RCB) WV-CB550 • Connect RCB to the camera with three coaxial cables (video signal, G/L \ signal, control signal) (BELDEN 8281 or equivalent, 300 m in maximum extension length). CONNECTION Zoom Lens Camera Remote Cable (for Zoom/Focus Control) Camera Cable VTR etc. Unit with SDI input Max. 200 mRear View of Camera VIDEO INVideo Monitor, VTR etc. Remote Control Box WV-CB550 AC120V 60Hz VIDEO OUT DC12V G/L IN Sync Generator G/L OUT AW-CA50T BNC AC Adaptor AW-PS505 CONTROL IN/OUT DC Power Cable AW-CA4T1 Coaxial cable (BELDEN 8281 or equivalent)
-10- APPEARANCE Unit: mm (inch) 92 (3-5/8) 111 (4-3/8) 21.5 (27/32) 70 (2-3/4) SDI OUT 1 ZOOM/FOCUS SDI OUT 2