Parts and their functions (continued)
6. Auto Setup button Use this button to start auto setup.
The setup status is output to the picture monitor.
Choose [FUNCTION]  [ASU SETUP] in the ROP menu to select 
[OUT FULL] or [OUT EASY] mode.  (For details, refer to Operations 
and Settings on the supplied CD-ROM)
OUT FULL: Standard setup based on an outdoor shooting chart

AWB→ABB→BSHD→ABB→AWB→FLARE→AWB
OUT EASY: Easy setup based on an outdoor shooting chart

AWB→ABB→AWB→FLARE→AWB
Align the position of...

Page 12

12
Parts and their functions (continued)
13
SCENE 4STORE
SCENE 3
SCENE 2SCENE/USER FILESCENE 1
USER 3
USER 2
USER 1
SHIFT
13
14 15
13. Scene/User File selector button Use this button to determine whether the SCENE/USER FILE 
select button will be used for selecting scene files or user files. 
Simultaneously pressing this button and a SCENE/USER FILE select 
button 1 to 3  to  allows you to 
select user files 1 to 3.
Scene file Scene files are mainly used by video 
engineers (VE) to create the required...

Page 13

1213
Parts and their functions (continued)
GAIN
FLARE/PED
DTLVR LOCK
161718
21 19 20
16. Control lock button  Use this button to lock (disable) the paint control operation. It controls 
GAIN (R, B), PED/FLARE (R,B) and DTL paint.
Each press of the button turns the function on or off.
On: ON (locks the paint control value)
Off: OFF (the paint control value changes)
 
z Using the  control lock button 
1. Use the controls (17 to 21) to make adjustments.
2. Press . The button lights.
The unit will register...

Page 14

14
Parts and their functions (continued)
15
CAMERANo.
DATA
SET
DISPLAY SELECTUP
DOWN SET UP
ND/CC M.GAIN/M.PEDSHUTTER
ND
M.GAIN
IRISM.PED
10-19
CC
SHTSYNCSELECT
EXECUTE
EXITSAVE/LOADSHIFT+UP+DOWN
2730
22 35
37 25
26 29 32
24
23283334
31
36
22. DATA SET button Use this button to increase set values when ND filter/CC filter, 
M.GAIN or SHUTTER/SYNCRO is displayed. Each press of the 
button increases the set value.
On: Enabled
Off: Disabled
The CC filter cannot be used on the AK-HC3800 studio handy...

Page 15

1415
Parts and their functions (continued)
29. M.GAIN/M.PED DISPLAY SELECT button   
EXIT button  (In setup mode)
Press this button to display and change M.GAIN or M.PED settings.
M.PED settings are only displayed, the DATA SET buttons  
 cannot be used to make settings. Use the Master pedestal 
control  to adjust the iris lever.
 
z Setting and Displaying  M.GAIN/M.PED
1.   Press  when IRIS or other (ND/CC, 
SHUTTER) DISPLAY SELECT status is displayed.
The button lights and the M.GAIN display  lights...

Page 16

16
Parts and their functions (continued)
17
IRIS/M.PED LOCKIRISM.PEDCHARA
MENU
SELECT
TALLY/CALLALM OPT
SENSE PUSH
PREVIEW
EXT
D.EXT COARSE
AUTO
FULLOPEN
CLOSE
CLOSE
403843
41
42
5039
44
51
47
49
48
55 52
53
54
46
45
38.
 Character/Menu button Use this function to switch on and off the characters (status screen) 
displayed on the picture monitor (PM).
Press and hold (for 2 seconds) to display the ROP menu on the 
picture monitor.
For details on the ROP menu, refer to Operations and Settings on the...

Page 17

1617
Parts and their functions (continued)
44. Iris lever Use this to control the iris level.
This function is enabled when the iris/master pedestal lock is 
released.
If the auto iris is not on, the iris can be controlled manually.
When the auto iris is on, the iris level (standard value for automatic 
aperture adjustment) is automatically adjusted.
Press the button at the front end of the lever to connect the preview 
signal from the preview connector.
During manual iris adjustments (when the , 
,...

Page 18

18
Parts and their functions (continued)
19
Connector Panel
12VINLAN RS-422PREVIEWCCU
SIGNAL GND
43
5
1
2
1. CCU connector 
(Hirose Electric: HR10A-10R-10P (71))
Connect this connector to the CCU of a camera.
Pin 
number Function
PolaritySignal flow
1 CAM DATA(H) +CAM→ROP
2 CAM DATA(L) -CAM→ROP
3 CAM CONT(H) +ROP→CAM
4 CAM CONT(L) -ROP→CAM
5 CAM No.A
6 CAM No.B
7 CAM No.C
8 CAM No.D
9 12V
10 GND
2. Preview connector 
(Hirose Electric: HR10A-7R-4PC(73))
This connector outputs the preview signal. It...

Page 19

1819
Specifications
„
„ GeneralPower input
Power supply:   12 V DC, 0.35 A (DC input range; 10 V DC - 16 V DC)
Power consumption: 4.2 W
indicates safety information.
CCU control       - Control signals (camera, CCU control)
              - Power supply (12 V DC)
*1
             *1 Can be provided from CCU or AC adapter PREVIEW control   
: Contact output
Maximum cable length  : 50 m (164 ft)
Operating temperature  : 0 °C to 40 °C (32 °F to 104 °F)
Storage temperature   : −20 °C to 60 °C (−4 °F...

Page 20

Information on Disposal for Users of Waste Electrical & Electronic Equipment (private households)
This symbol on the products and/or accompanying documents means that used electrical and electronic products should not be 
mixed with general household waste.
For proper treatment, recovery and recycling, please take these products to designated collection points, where they will be 
accepted on a free of charge basis. Alternatively, in some countries you may be able to return your products to your local...
Start reading Panasonic Remote Operation Panel Ak Hrp200 Operating Instructions

Related Manuals for Panasonic Remote Operation Panel Ak Hrp200 Operating Instructions

All Panasonic manuals