Page 1
Model No. AK-HRP200G Operating Instructions Remote Operation Panel VQT4S52 ● ● How●the●operating●instructions●are●organized ・● Basics●(this●manual): This manual describes how to connect the unit to the required equipment and set it up. Before installing the unit, be sure to read the manual to ensure that you know how to install it correctly. The manual is provided as a PDF file on the CD-ROM supplied with the unit. ・● Operations●and●Settings: Operations and Settings describe how to operate and...
Page 2
23 Read this first! indicates safety information. DO NOT REMOVE PANEL COVERS BY UNSCREWING THEM. No user serviceable parts inside. Refer servicing to qualified service personnel. WARNING:• To reduce the risk of fire, do not expose this equipment to rain or moisture. • To reduce the risk of fire, keep this equipment away from all liquids. Use and store only in locations which are not exposed to the risk of dripping or splashing liquids, and do not place any liquid containers on top of...
Page 3
23 Read this first! (continued) EMC NOTICE FOR THE PURCHASER/USER OF THE APPARATUS 1. Applicable standards and operating environment (AK-HRP200)The apparatus is compliant with:• standards EN55103-1 and EN55103-2 2009, and • electromagnetic environments E1, E2, E3, E4 and E5. 2. Pre-requisite conditions to achieving compliance with the above standards Peripheral equipment to be connected to the apparatus and special connecting cables • The purchaser/user is urged to use only equipment which has been...
Page 4
4 Read this first! (continued) 5 ENGLISH How to open the operating instruction manual PDF filesDiscontinue installation if the installation screen of the software opens as a result of inserting the CD-ROM. When [INDEX.pdf] on the CD-ROM is opened, a list of the operating instruction manuals will be displayed. Click on the document name of the manual to be opened. Adobe® Reader® is required to read PDF files. It can be downloaded from the home page of Adobe Systems. DEUTSCH...
Page 5
45 About this instruction manual About trademarks and registered trademarks• Adobe® and Reader® are either registered trademarks or trademarks of Adobe Systems Incorporated in the United States and other countries. • SDHC logo is a trademark of SD-3C and LLC. • Other names of companies or products in this manual are either registered trademarks or trademarks of their respective owners. About copyrightDistributing, copying, disassembling, reverse compiling, reverse...
Page 6
67 Introduction OverviewThis unit is a remote operation panel for controlling a studio handy camera (AK-HC3800) and a camera controller unit (AK-HCU200). Use a dedicated optical fiber cable to connect a studio handy camera to a camera controller unit and use an ROP cable to connect this unit to the camera controller unit. Memory CardsUse only memory cards that comply with the SD and SDHC specifications in this unit. Be sure to format memory cards in this unit. This unit...
Page 7
67 Features z This unit is a remote operation panel for controlling a studio handy camera (AK-HC3800) and a camera controller unit like the AK-HCU200. z A simple button layout and an IRIS control lever ensure intuitive and stable operation. z Scene files, user files and lens files can be stored on memory cards. Accessories Make sure that the following accessories are supplied. • Be sure to appropriately dispose of the packing material when you have unpacked the product. CD-ROM...
Page 8
89 Precautions for installation Observe the following in addition to the information included in “Read this first!”. Have your supplier install the unit and handle connections. Cable connections• Be sure to use dedicated remote operation panel (ROP) cables. • If the unit will not be used for an extended period of time, disconnect the ROP cables to save electricity. Handle carefully• Make sure you do not drop or expose the unit to strong impacts or vibrations that could...
Page 9
89 Setting up the unit (continued) System component connections 12VINLAN RS-422PREVIEWCCU SIGNAL GND ROP cable AK-HRP200 Connection example: AK-HCU200 1. Connect the CCU connector on this unit to the ROP connector on the CCU rear panel using a dedicated ROP cable (sold separately). 2. After having connected all the components, turn the CCU main power on, and then turn the camera on. • If no camera is connected, the number of CCU functions that this unit can control is limited. • Turn off the CCU...
Page 10
1011 Parts and their functions Operation panel A beep (buzzer) sounds when a button is pressed. However, buttons do not beep when the buzzer is set to Off in setup mode. AUTOBLACKSET UP WHITE BARS TEST VF POWER HEAD POWER DTL OFF SHUTTER ON STEP/SYNC KNEE OFF SKINDTL MATRIX 5600K 1 23 45 6 7 8910 11 12 1. Camera power button Use this button to control camera power remotely. However, it will not function unless the CCU and the camera are turned on. Each press of the button turns the power on and off. On...