Home > Panasonic > Projector > Panasonic Projector Pt D12000u Operating Instructions

Panasonic Projector Pt D12000u Operating Instructions

    Download as PDF Print this page Share this page

    Have a look at the manual Panasonic Projector Pt D12000u Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							ENGLISH – 101
    Special Features
    Authentication set up page  „
    The POP server is set on this page when POP authentication is required for mail transmissions.
    Click [Detailed set up], then [Authentication set up] to display the POP server setup page.
    Select the authentication method specified by 
    your Internet service provider.
    Set this if SMTP authentication has been 
    selected.
    POP server name field
    Available input characters: 
    Alphanumeric characters (A–Z, a–z, 0–9), 
    hyphen (-), period (.)
    POP server user name field
    POP server password field
    Enter the port number for the SMTP server 
    (normally “25”).
    Enter the port number for the POP server 
    (normally “110”).
    Button to update settings
    Ping test page  „
    This page makes it possible to check whether the network is connected to the E-mail server, POP server, 
    DNS server, etc.
    Click [Detailed set up], then [Ping test] to display the Ping test page.
    Enter the IP address of the server to be 
    tested.
    Button for conducting the test.
    Display which appears when the 
    connection was successful.
    Display which appears when the 
    connection failed. 
    						
    							102 – ENGLISH
    How to use network functions (continued)
    Contents of mail sent  „
    Mail with the contents shown below is sent when the E-mail settings have been established.  z
    === Panasonic projector report(CONFIGURE) ===
    Projector Type          : DZ12000
    -----  E-mail setup data -----
    TEMPERATURE WARNING SETUP 
    MINIMUM TIME            at [ 60] minutes interval 
    INPUT AIR TEMPERATURE   Over [ 35degC / 95degF ] 
    OUTPUT AIR TEMPERATURE  Over [ 60degC / 140degF ] 
    ERROR                   [ ON  ] 
    LAMP1 RUNTIME           [ OFF ]   at REMAIN [ 200] H 
    LAMP1 RUNTIME           [ OFF ]   at REMAIN [ 100] H 
    LAMP2 RUNTIME           [ OFF ]   at REMAIN [ 200] H 
    LAMP2 RUNTIME           [ OFF ]   at REMAIN [ 100] H 
    LAMP3 RUNTIME           [ OFF ]   at REMAIN [ 200] H 
    LAMP3 RUNTIME           [ OFF ]   at REMAIN [ 100] H 
    LAMP4 RUNTIME           [ OFF ]   at REMAIN [ 200] H 
    LAMP4 RUNTIME           [ OFF ]   at REMAIN [ 100] H 
    INPUT AIR TEMPERATURE   [ OFF ] 
    OUTPUT AIR TEMPERATURE  [ OFF ] 
    PERIODIC REPORT 
    Sunday    [ ON  ]  Monday    [ ON  ]  Tuesday   [ ON  ]  Wednesday [ ON  ] 
    Thursday  [ ON  ]  Friday    [ ON  ]  Saturday  [ ON  ] 
    00:00  [ ON  ]    01:00  [ ON  ]    02:00  [ ON  ]    03:00  [ ON  ] 
    04:00  [ ON  ]    05:00  [ ON  ]    06:00  [ ON  ]    07:00  [ ON  ] 
    08:00  [ ON  ]    09:00  [ ON  ]    10:00  [ ON  ]    11:00  [ ON  ] 
    12:00  [ ON  ]    13:00  [ ON  ]    14:00  [ ON  ]    15:00  [ ON  ] 
    16:00  [ ON  ]    17:00  [ ON  ]    18:00  [ ON  ]    19:00  [ ON  ] 
    20:00  [ ON  ]    21:00  [ ON  ]    22:00  [ ON  ]    23:00  [ ON  ] 
    -----  check system -----
    MAIN CPU BUS               [   OK   ]
    FAN                        [   OK   ]
    OPTICS MODULE TEMPERATURE  [   OK   ]
    INPUT AIR TEMPERATURE      [   OK   ]
    OUTPUT AIR TEMPERATURE     [   OK   ]
    LAMP1 REMAIN TIME          [   OK   ]
    LAMP2 REMAIN TIME          [   OK   ]
    LAMP3 REMAIN TIME          [   OK   ]
    LAMP4 REMAIN TIME          [   OK   ]
    Mail with the contents shown below is sent when an error has occurred.  z
    === Panasonic projector report(ERROR) ===
    Projector Type          : DZ12000
    -----  check system -----
    MAIN CPU BUS               [   OK   ]
    FAN                        [   OK   ]
    OPTICS MODULE TEMPERATURE  [   OK   ]
    INPUT AIR TEMPERATURE      [   OK   ]
    OUTPUT AIR TEMPERATURE     [   OK   ]
    LAMP1 REMAIN TIME          [   OK   ]
    LAMP2 REMAIN TIME          [   OK   ]
    LAMP3 REMAIN TIME          [   OK   ]
    LAMP4 REMAIN TIME          [   OK   ]
    LAMP1 STATUS               [   OK   ]
    LAMP2 STATUS               [   OK   ]
    LAMP3 STATUS               [   OK   ]
    LAMP4 STATUS               [   OK   ]
    APERTURE(CONTRAST-SHUTTER) [   OK   ]
    SHUTTER(MUTE-SHUTTER)      [   OK   ]
    DIRTY AIR FILTER           [ FAILED ]
    AIR FILTER CLEANER UNIT    [   OK   ]
    OPTICS MODULE TEMP.SENSOR  [   OK   ]
    INPUT AIR TEMP.SENSOR      [   OK   ]
    OUTPUT AIR TEMP.SENSOR     [   OK   ]
    BATTERY                    [   OK   ]
    CLOGGED FILTER SENSOR      [   OK   ]
    LENS SHIFT                 [   OK   ]
    COVER OPEN                 [   OK   ]
    AC POWER                   [   OK   ]
    (Error code 00 00 00 00 00 00 00 00 00 00 00 10 00 00 00 00)
    Input air temperature      : 27 degC /  80 degF
    Optics module temperature  : 34 degC /  93 degF
    Output air temperature     : 33 degC /  91 degF
    SET RUNTIME        12 H
    POWER ON           12 times
    LAMP1 ON          419 times
    LAMP1 HIGH        314 H
    LAMP2 ON          363 times
    LAMP2 HIGH        252 H 
    						
    							ENGLISH – 103
    Special Features
    Adjust clock page  „
    Click [Detailed set up], then [Adjust clock] to display the Adjust clock page.
    Time zone selection
    Button to update time zone setting
    Button to update time and date settings 
    New date field
    New time field
    Note
    If the time becomes incorrect immediately after setting the correct time, then the battery needs to be changed.  • 
    Contact the dealer where you bought the projector to have the battery changed.
    Network config page  „
    Click [Detailed set up], then [Network config] to display the Network config page.
    DNS server address (secondary) field
    Available input characters: 
    Numeric characters (0–9), period (.)
    (Example: 192.168.0.254)
    Set this to ON to enable the DHCP client 
    function.
    Enter the IP address if DHCP server is not 
    used.
    Enter the net mask if DHCP server is not 
    used.
    Enter the gateway address if DHCP server is 
    not used.
    DNS server address (primary) field
    Available input characters: 
    Numeric characters (0–9), period (.)
    (Example: 192.168.0.253)
    Enter the port number here. Number 80 is 
    normally used.
    Enter the name of the projector here. Enter 
    the host name here if it is required when 
    the DHCP server is going to be used, for 
    instance.
    Button to update settings 
    						
    							104 – ENGLISH
    How to use network functions (continued)
    Firmware update page  „
    (The firmware should be updated only by an individual with the specialized knowledge required to do this.)
    Enter here the filename of the firmware to be 
    updated.
    After entering the filename, press the [Upload] 
    button. Data transfer is now commenced.
    It will require several minutes for the data to 
    be transferred.
    The time taken will differ depending on the 
    network conditions.
    Displays the current version.
    Displays the updated version.
    Check the updated version against the current 
    version, and if everything is in order, press 
    the [OK] button. Version data rewriting is now 
    commenced.
    Do not turn off the power while the version 
    data is being rewritten.
    Messages such as the ones shown below appear during data rewriting.
    The following message appears upon completion of the version data rewriting. 
    						
    							ENGLISH – 105
    Special Features
     
    Using the PJLink™ protocol
    The network function of the projector supports PJLink™ class 1, and the PJLink™ protocol can be used to 
    perform projector setting and projector status query operations from a PC.
    Supported commands
    The following table lists the PJLink™ protocol commands that can be used to control the projector.
    Command Control details Notes
    POWR Power supply controlParameters
    0 = Standby
    1 = Power ON
    POWR ? Power supply status queryParameters
    0 = Standby  1 = Power ON
    2 = Cool-down in progress  3 = Warm-up in progress
    INPT Input selectionParameters
    11 = RGB1  12 =RGB2 
    21 = VIDEO  22 = S-VIDEO 
    31 = DVI-D
    32 = AUX (only enabled if ET-MD77DV, ET-MD77SD1, ET-MD77SD3 or 
    ET-MD100SD4 is installed) INPT ? Input selection query
    AVMT Shutter controlParameters
    30 = Shutter mode off (picture mute canceled)
    31 = Shutter mode on (picture mute) AVMT ? Shutter mode query
    ERST? Error status queryParameters
    1st byte:   Indicates fan errors, range 0--2
    2nd byte:   Indicates lamp errors, range 0--2
    3rd byte:   Indicates temperature errors, range 0--2
    4th byte:   Indicates cover open errors, range 0--2
    5th byte:   Indicates filter errors, range 0--2
    6th byte:   Indicates other errors, range 0--2
    Definitions for each value from 0 to 2 are as follows. 
    0 = No error known  1 = Warning  2 = Error
    LAMP ? Lamp status queryParameters
    1st digits (1--5 digits): Lamp 1 cumulative operating time
    2nd digit: 0 = Lamp 1 off, 1 = Lamp 1 on
    3rd digits (1--5 digits): Lamp 2 cumulative operating time
    4th digit: 0 = Lamp 2 off, 1 = Lamp 2 on
    5th digits (1--5 digits): Lamp 3 cumulative operating time
    6th digit: 0 = Lamp 3 off, 1 = Lamp 1 on
    7th digits (1--5 digits): Lamp 4 cumulative operating time
    8th digit: 0 = Lamp 4 off, 1 = Lamp 2 on
    INST ? Input selection list queryThe following are returned as parameters. 
    “11 12 21 22 31” (If any of the ET-MD77DV, ET-MD77SD1, ET-MD77SD3 or 
    ET-MD100SD4 are installed, “11 12 21 22 31 32” is returned.)
    NAME ? Projector name query The name set for “HOST NAME” in “NETWORK” is returned. 
    INF1 ? Manufacturer name query “Panasonic” is returned. 
    INF2 ? Model name query “D12000” or “DZ12000” is returned.
    INFO ? Other information query Information such as version number is returned. 
    CLSS ? Class information query “1” is returned. 
    PJLink™ security authorization  „
    When using PJLink™ with security authorization, either of the password set for administrator privileges and 
    the password set for user privileges with Web browser control can be used as the password for PJLink™. 
    When using PJLink™ without security authorization, set use without the password for administrator privileges 
    and the password for user privileges of Web browser control.
    PJLink™ is a pending trademark in Japan, the United States, and other countries and regions. • 
    For specifications regarding PJLink™, refer to the Japan Business Machine and Information System 
    Industries Association website.
    URL: http://pjlink.jbmia.or.jp/ 
    						
    							106 – ENGLISH
    Using the  serial terminals
    The main unit is equipped with SERIAL terminals located in its connection terminals, and this terminal is compliant 
    with RS-232C/RS-422. Also a serial output terminal is provided to enable plural projector control.
    Examples of connection
    For RS-232C  „
    Single projector  z
    RS-232C IN RS-422 IN
    RS-422 OUTSERIAL
    PC
    D-Sub 9-pin (male)
    Communication cable (straight) Connection terminals on projector D-Sub 9-pin (female)
    Multiple projectors  z
    RS-232C IN RS-422 IN
    RS-422 OUTSERIALRS-232C IN RS-422 IN
    RS-422 OUTSERIALPC
    Connection terminals 
    on projector 1Connection terminals 
    on projector 2
    Communication cable (straight) Communication cable (straight)D-Sub 9-pin (male) D-Sub 9-pin (female)D-Sub 9-pin (male) D-Sub 9-pin 
    (male)D-Sub 9-pin 
    (male) D-Sub 9-pin (female) D-Sub 9-pin (female)
    Pin assignments and signal names  „
    Pin 
    No.Signal 
    nameDescription
    1
    NC
    2
    TXD Send data
    3
    RXD Receive data
    4
    Connected internally
    5
    GND Ground
    6
    NC
    7
    CTS
    Connected internally
    8
    RTS
    9
    NC
    D-Sub 9-pin 
    (female), external 
    appearance
    Serial input 
    terminal
    Communication conditions (Factory setting)  „
    Signal level RS-232C-compliant
    Synchronization method Start-stop synchronization
    Baud rate 9 600bps
    Parity None
    Character length 8 bits
    Stop bit 1 bit
    X parameter None
    S parameter None 
    						
    							ENGLISH – 107
    Special Features
    For RS-422  „
    Single projector  z
    RS-232C IN RS-422 IN
    RS-422 OUTSERIAL
    PC
    D-Sub 9-pin (male)
    Communication cable (straight) Connection 
    terminals on 
    projectorD-Sub 9-pin (female)
    Multiple projectors  z
    RS-232C IN RS-422 IN
    RS-422 OUTSERIALRS-232C IN RS-422 IN
    RS-422 OUTSERIALPC
    Connection 
    terminals on 
    projector 1Connection 
    terminals on 
    projector 2
    Communication cable (straight) Communication cable (straight)D-Sub 9-pin (male) D-Sub 9-pin (female) D-Sub 9-pin (male)D-Sub 9-pin 
    (male)D-Sub 9-pin 
    (male)
    D-Sub 9-pin (female) D-Sub 9-pin (female)
    Pin assignments and signal names  „
    Pin 
    No.Signal 
    nameDescription
    1
    NC
    2
    TXD(-) Data transmit terminal (-)
    3
    RXD(+) Data receive terminal (+)
    4
    Connected internally
    5
    NC
    6
    Connected internally
    7
    TXD(+)
    Data transmit terminal (+)
    8
    RXD(-) Data receive terminal (-)
    9
    FG GND
    D-Sub 9-pin 
    (female), external 
    appearance
    Serial input 
    terminalPin 
    No.Signal 
    nameDescription
    1
    NC
    2
    RXD(-) Data receive terminal (-)
    3
    TXD(+)
    Data transmit terminal (+)
    4
    Connected internally
    5
    NC
    6
    Connected internally
    7
    RXD(+) Data receive terminal (+)
    8
    TXD(-) Data transmit terminal (-)
    9
    FG GND
    D-Sub 9-pin 
    (male), external 
    appearance
    Serial input 
    terminal
    Communication conditions (Factory setting)  „
    Signal level RS-422-compliant
    Synchronization method Start-stop synchronization
    Baud rate 9 600bps
    Parity None
    Character length 8 bits
    Stop bit 1 bit
    X parameter None
    S parameter None 
    						
    							108 – ENGLISH
    Using the serial terminals (continued)
    Basic format
    Transmission from the computer begins with STX, then the ID, command, parameter, and ETX are sent in this 
    order. Add parameters according to the details of control.
    STX C1 C2 C3 : P1 P2Pn ETXA D I 1 I 2 ;
    Start 
    (1 byte)(2 bytes) Two ID 
    characters 
    (2 bytes)
    ZZ, 1 to 64 and 0A to 0Z
    Semicolon 
    (1 byte)
    ID designate3 command 
    characters 
    (3 bytes)Colon 
    (1 byte)
    Parameter
    (undefined length)End
    (1 byte)
    Attention
    No command can be sent or received for 10 to 60 seconds after the lamp starts lighting. Try sending any  • 
    command after that period has elapsed.
    When transmitting multiple commands, be sure to wait until 0.5 seconds has elapsed after receiving the  • 
    response from the projector before sending the next command. When sending commands without parameters, 
    a colon (:) is not necessary.
    Note
    When the wrong command is sent, the “ER401” or “ER402” status is sent from the projector to the personal  • 
    computer.
    Projector ID supported on the RS-232C interface is ZZ (ALL) and a group of 1 to 64 and 0A to 0Z. • 
    The “STX” character code is 02 and the “ETX” character code is 03. • 
    If a command is sent with a projector ID specified, the projector will return answer back only in the following  • 
    cases:
    If it coincides with the projector ID
    If the ID specification is ALL and responding (ID ALL) is on
    If the ID specification is Group and responding (ID Group) is on
    Control commands
    When controlling the projector from a computer, the following commands are available:
    Command Function of command Remarks
    PON Power “ON”In standby mode, commands other than “PON” are invalid.
    While the lamp is ON and being controlled, a “PON” command will not be  • 
    accepted. POF Power “OFF”
    IIS Switch input modesParameter
    VID = VIDEO  SVD = S-VIDEO  DVI = DVI-D
    RG1 = RGB1  RG2 = RGB2  AUX = AUX
    QSLQuery for active lamp 
    mode Parameter
    0 = QUAD, 1 = L1/L4, 2 = L2/L3, 3 = DUAL, 4 = L1/L2/L3, 5 = L1/L2/L4, 
    6 = L1/L3/L4, 7 = L2/L3/L4, 8 = TRIPLE, 9 = L1, 10 = L2, 11 = L3, 12 = L4, 
    13 = SINGLE
    LPM Active lamp modeParameter
    0 = QUAD, 1 = L1/L4, 2 = L2/L3, 3 = DUAL, 4 = L1/L2/L3, 5 = L1/L2/L4, 
    6 = L1/L3/L4, 7 = L2/L3/L4, 8 = TRIPLE, 9 = L1, 10 = L2, 11 = L3, 12 = L4, 
    13 = SINGLE
    Note
    If you need a detailed command list, please contact your dealer. •  
    						
    							ENGLISH – 109
    Special Features
    Cable specifications
    Connecting to a PC  „
    For RS-232C  z
    1
    2
    3
    4
    5
    6
    7
    8
    91
    2
    3
    4
    5
    6
    7
    8
    9NC NC
    NC NC
    NC NC
    NC NC ProjectorComputer (DTE 
    specifications)
    When multiple projectors are connected  „
    1
    2
    3
    4
    5
    6
    7
    8
    91
    2
    3
    4
    5
    6
    7
    8
    9
    1st 
    (RS-422 OUT)2nd 
    (RS-422 IN)
    Attention
    To connect the computer to the SERIAL terminal, prepare an adequate communication cable that fits to your  • 
    personal computer. 
    						
    							110 – ENGLISH
    Using the  Remote 2 terminal
    Using the REMOTE 2 terminal provided on the connection terminals of the main unit, it is possible to operate the 
    projector from a control panel etc. furnished in a distant location where infrared remote control signal cannot be 
    received.
    Example of a control panel layout
    Remote terminal External control
    Remote terminal/External control
    STANDBY ON
    LAMP
    RGB1
    RGB2VIDEO
    S-VIDEO
    Projector set up in a meeting room Control panel located in a different room
    DVI-D
    Pin assignments and control
    Be sure to short-circuit Pins 1
     and 9
     when controlling.
    Names of terminals Open (H) Short (L)
    1
    GND GND
    2
    POWER OFF ON
    3
    RGB1 Other RGB1
    4
    RGB2 Other RGB2
    5
    VIDEO Other VIDEO
    6
    S-VIDEO Other S-VIDEO
    7
    DVI-D Other DVI-D
    8
    SHUTTER OFF ON
    9
    RST / SETControlled by 
    remote controlControlled by 
    external contact
    D-Sub 9-pin (female) 
    external appearance
    Note
    The above figure shows the pin assignment and control details when “REMOTE2 MODE” (p. 80) is “DEFAULT”.  • 
    When using “REMOTE2 MODE” with “USER”, the pin assignment and control details are those set for “USER”.
    When pin  • 1
     and pin 9
     are short-circuited, the following buttons on the projector's control panel and on the 
    remote control cannot be used. 
    POWER button, SHUTTER button 
    In addition, the RS-232C commands and network functions that correspond to these functions cannot be used 
    either. 
    When pin  • 1
     and pin 9
     are short-circuited and then any one of pins 3
     to 7
     is short-circuited to pin 1
    , the 
    following buttons on the projector's control panel and on the remote control cannot be used.
    POWER button, input selection buttons (RGB1, RGB2, DVI-D, AUX, VIDEO, S-VIDEO), SHUTTER button 
    In addition, the RS-232C commands and network functions that correspond to these functions cannot be used 
    either. 
    						
    All Panasonic manuals Comments (0)

    Related Manuals for Panasonic Projector Pt D12000u Operating Instructions