Panasonic Plc Adaptor Add-on Unit Bl-pa300a Operating Instructions
Here you can view all the pages of manual Panasonic Plc Adaptor Add-on Unit Bl-pa300a Operating Instructions. The Panasonic manuals for Adapter are available online for free. You can easily download all the documents as PDF.
Page 11
11[For assistance, please call: 1-800-272-7033] Installation InstallationRegistration Follow the procedure below when you want to: Add an additional terminal to your HD-PLC network. Re-register the master and terminal after resetting the master. 1.Confirm that the mode selector of the master adaptor is set to MASTER and the MASTER indicator is lit green. 2.Confirm that the mode selector of the terminal adaptor that you want to register is set to TERMINAL. 3.Plug the power strip into the same...
Page 12
12 Installation 7.When the PLC indicator of each adaptor lights in green, registration was successful. If the PLC indicators do not light in green, see page 19. 8.Wait about 30 seconds, then unplug the adaptors and place them where you plan to use them (see page 13). Note While registering an additional terminal, communication between all other adaptors may be disrupted for about 10 seconds. BL-PA300A_OI.book Page 12 Wednesday, August 6, 2008 9:59 AM
Page 13
13[For assistance, please call: 1-800-272-7033] Installation Placing the adaptors Refer to the information on page 5 when selecting a location to place your adaptors. Note If you have purchased additional adaptors, make sure you have registered them to the master (see page 11) before placing them where you plan to use them. 1.Connect the adaptor to a wall outlet in the room where you plan to use it. 2.Confirm that the PLC indicator of each adaptor lights in green when you plug the adaptors into...
Page 14
14 Installation Connecting adaptors to network devices Once you have placed the adaptors where you plan to use them and are satisfied with the network speed test results for your terminals (see page 15), follow the procedure below to connect your adaptors to your network devices (broadband router, hub, computer, network printer, network camera, etc.). This will integrate your HD-PLC network with your home network. 1.Confirm that each adaptor is plugged in correctly to the wall outlet. Do not plug...
Page 15
15[For assistance, please call: 1-800-272-7033] Useful Information Useful InformationTesting a terminal’s network speed Once you have connected the adaptors where you plan to use them, follow the procedure below to test the speed of each terminal’s network connection to the master. Make sure that the terminal has already been registered to a master (see page 11). 1.Press and hold the terminal’s SETUP button for about 1 second. The indicators light one at a time. 2.After a few seconds, the network...
Page 16
16 Useful Information 4.If you are not satisfied with the speed test result, connect the terminal to a different wall outle t and repeat the test. Note The fastest and slowest speeds are displayed by the indicators alternatively for about 6 seconds. If there is little difference between the fastest and slowest speeds, they will be displayed as the same speed. At least one indicator (“Good” network speed) must be lit in order to use the terminal. If you are not satisfied with the speed test...
Page 17
17[For assistance, please call: 1-800-272-7033] Useful Information Understanding the indicators PLCGreen, lit The adaptor is succe ssfully connected to the HD-PLC network. Green, flashing The terminal is bei ng registered to the master. Green, flashes once every 5 seconds The adaptor is registered to the master, but it is not connected to the HD-PLC network. Red, lit for 5 seconds There was an error during registration. Try again. Red, lit The adaptor is not functioning properly and cannot...
Page 18
18 Useful Information Resetting an adaptor Normally an adaptor does not need to be reset, however, you may need to reset an adaptor if: You are concerned that another ad aptor may have been accidentally registered to your master. (For ex ample, the adaptor of someone who lives in the same apartment building as you.) An error occurs while registering a terminal to the master. You are registering an adaptor. Note Resetting a terminal erases its registration to the master. It must be registered...
Page 19
19[For assistance, please call: 1-800-272-7033] Useful Information Troubleshooting Performance issues The troubleshooting notes in this section are provided to resolve the following types of performance issues. Inability to transmit data over the HD-PLC network Slow data transmission speeds (interrupted video or audio, slow download speeds, etc.) Intermittent or varied performance (faster at certain times, slower at others) Interference caused by an adaptor The PLC indicator is not lit in...
Page 20
20 Useful Information 4.If you are not able to plug an adaptor directly into a wall outlet and must use a power strip, make sure the power strip is plugged directly into a wall outlet and not to another power strip. 5.Make sure the power strip does not have a noise filter or a surge protector, as these features may in terfere with the performance of your adaptors. 6.Use a power strip with an AC cord that is as short as possible. 7.Re-register the terminal following the procedure on page 11. If the...