Have a look at the manual Panasonic Multi Format Live Switcher Av Hs400n Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
81 5. System settings 5-8. Initialization Initialization returns the set data to the factory shipment status. (The date and time data is not initialized.)1 Press the [FUNC] b utton to light its indicator , and then press the [SYSTEM] button to display the SYSTEM menu. 2 Turn [F1] to display the Initial sub menu. Initial Init↓ 5/14 3 Press [F] to initialize the settings. The “Init?” message appears. 4 To initialize the settings, turn [F] to select YES, and then press the [F] switch. T o cancel the initialization, turn [F ] to select NO, and then press the [F] switch. Initial Init? 5/14 No YES
8 6. External interfaces This unit comes with RS-4, GPI and tally connectors to serve as external interfaces. 6-1. RS-422 connector This enables the unit to be controlled by an external device. Use it with the settings below. (D-sub 9-pin, female)Baud rate: 38400 bps Parity: ODD Stop bit: 1 bit 12345 9 8 7 6 Pin assignment Pin No. Signal name Description of signal 1 FRAME GROUND Frame ground TXD – Send data (–) 3 RXD + Receive data (+) 4 GROUND Ground 5 NC Not used 6 GROUND Ground 7 TXD + Send data (+) 8 RXD – Receive data (–) 9 FRAME GROUND Frame ground The following lists the functions which can be controlled by editing controller AG-A850. (Compliant with the GVG protocol) • Crosspoint switch • Wipe pattern selection (BKGD) • Transition mode (MIX/WIPE) selection • Auto transition time setting • Auto transition execution RS-422 control AV-HS400 RS-422 control AV-HS400 RS-422 control AV-HS400 RS-422 control AV-HS400 0 WIPE #1 1 SQ #14SL #1 363D #1 1 WIPE # 13SQ # 5 SL # 37 3D # WIPE #3 14 SQ #36SL #3 383D #3 3 WIPE #4 15 SQ #4 7SL #4 393D #4 4 WIPE #5 16 SQ #5 8—403D #5 5 WIPE #6 17 SQ #6 9 SL #6 413D #6 6 WIPE #7 18 SQ #7 30SL #7 43D #7 7 WIPE #8 19 SQ #8 31SL #8 433D #8 8 WIPE #9 0 SQ #9 3SL #9 443D #9 9 WIPE #10 1 SQ #10 33—45 3D #10 10 WIPE #11 —34 —46 3D #11 11 WIPE #1 3 SQ #135—47 3D #1 : Set “No. 56” when control is to be exercised from the AG-A850. On the System sub menu of the SYSTEM menu, set On or Off for control from the external device (editor) connected to the RS-4 connector . For details on the settings, see 5-6-.
83 6. External interfaces 6-2. GPI connector These connectors enable the unit to be controlled from an external source. Signals are input using contacts. The following types of control are exercised using the contacts as triggers. Use stereo mini plugs with a 3.5 mm diameter for connection to the unit. GPI2 COMMON GPI1 Function assignedDescription of control Remarks AUTO Control exercised using AUTO button on unit’s panel CUT Control exercised using CUT button on unit’s panel DSK Control exercised using DSK button on unit’s panel PinP Control exercised using PinP button on unit’s panel FTB Control exercised using FTB button on unit’s panel BGDAUTO Auto transition control for background Control is exercised regardless of the selection statuses of the switches and buttons on the unit’s panel. BGDCUT Cut transition control for background KEYAUTO Auto transition control for key KEYCUT Cut transition control for key PortFunction assigned Description of control GPI1 AUTOControl exercised using AUTO button on unit’s panel GPI DSKControl ex ercised using DSK button on unit’s panel Use the GPI sub menu under the SYSTEM menu to set the functions to be controlled using the external switches connected to the GPI ports and to enable or disable the control using the external switches. For details on the settings, see 5-6-3.
84 6. External interfaces 6-3. Tally connector The tally connector comes with tally output, output enable, power supply or fan alarm output pins. The output signals from the tally output pins are for lighting the tally lamps, and these outputs are open collector outputs. (D-sub 15-pin male) 54321 9 10 11 126 137 148 15 Pin assignment Pin No. Signal name Input/output Description of signal 1 IN1Open collector output Tally output of input video 1 IN Open collector output Tally output of input video 3 IN3Open collector output T ally output of input video 3 4 IN4Open collector output Tally output of input video 4 5 IN5Open collector output Tally output of input video 5 6 IN6Open collector output Tally output of input video 6 7 IN7Open collector output Tally output of input video 7 8 IN8Open collector output Tally output of input video 8 9 ALARM Open collector output Fan alarm or power supply alarm output 10, 11, 1 RESER VED K eep these pins unconnected. 13 ENABLE Input Enable signal of tally output and alarm output Open: Output; GND: no output 14, 15 GROUND GROUND Ground Pins 1 to 9 must satisfy the following conditions: Dielectric strength: Max. DC 4 V Current: Max. 50 mA Example of tally connections AV-HS400N (Max. voltage: 24V) Tally LED GROUND (Max. current: 50mA)Tally, Alarm output (IN1 to 8, ALARM)
85 7. Setting menu table A setting is entered when an item displayed (↓) is selected and then the [F1], [F], [F3], [F4] or [F5] switch is pressed. (It will not be entered unless the switch is pressed.) Menu Sub menuParameter 1 Parameter 2 Parameter 3 Parameter 4Turn F1 to select. Turn F to select. Turn F3 to select. Turn F4 to select. Turn F5 to select. TIME BKGD ParameterTransTime Unit — 1/5 Setting range 0 to 13s 0 to 999f Frame, Sec — Default value 1s 0fSec — KEY ParameterTransTime Unit — /5 Setting range 0 to 13s 0 to 999f Frame, Sec — Default value 1s 0fSec — DSK ParameterTransTime Unit — 3/5 Setting range 0 to 13s 0 to 999f Frame, Sec — Default value 1s 0fSec — PinP ParameterTransTime Unit — 4/5 Setting range 0 to 13s 0 to 999f Frame, Sec — Default value 1s 0fSec — FTB Parameter Unit — 5/5 Setting range 0 to 13s 0 to 999f Frame, Sec — Default value 1s 0fSec — WIPE Border ParameterBorder WidthSoft 1/5 Setting range On, Off 0.1 to 100.0 0.0 to 100.0 Default value Off 5.00.0 BodrCol ParameterHue SatLumLoad ↓ /5 Setting range 0.0 to 359.9 0.0 to 100.0 0.0 to 108.0 White , Y ellow , Cyan , Green , Magenta , Red , Blue , Black Def ault value 0.0 0.0100.0White WIPEPos ParameterSelect X-PosY-PosCopyTO ↓ 3/5 Setting range BKGD, KEY −100.00 to +100.00−100.00 to +100.00Display only Default value BKGD 0.000.00 SQPos ParameterSelect X-PosY-PosCopyTO ↓ 4/5 Setting range BKGD, KEY −100.00 to +100.00−100.00 to +100.00Display only Default value BKGD 0.000.00 Modify ParameterLight Trim 5/5 Setting range On, Off Off, 4:3 (Selection enabled when HD format is used) Default value Off Off COLOR CBGD ParameterHue SatLumLoad ↓ 1/1 Setting range 0.0 to 359.9 0.0 to 100.0 0.0 to 108.0 White, Yellow, Cyan, Green, Magenta, Red, Blue, Black Default value 0.0 0.0100.0White
86 MenuSub menuParameter 1 Parameter 2 Parameter 3 Parameter 4Turn F1 to select. Turn F to select. Turn F3 to select. Turn F4 to select. Turn F5 to select. KEY KEY ParameterType LumKey Fill PVW 1/8 Setting range Lum, Linear, Chroma ChrmOn, ChrmOff Bus, Matte Auto, On, Off Default value Linear ChrmOff Bus Auto Adjust ParameterClip GainDensityInvert /8 Setting range 0.0 to 108.0 0.0 to 00.0 0.0 to 100.0 On, Off Default value 0.0 100.0100.0Off FillMatt ParameterHue SatLumLoad ↓ 3/8 Setting range 0.0 to 359.9 0.0 to 100.0 0.0 to 108.0 White, Yellow, Cyan, Green, Magenta, Red, Blue, Black Default value 0.0 0.0100.0White Edge ParameterType Width 4/8 Setting range Off, Border, Drop, Shadow, Outline 0 to 4 Default value Off EdgeCol Parameter Hue SatLumLoad ↓ 5/8 Setting range 0.0 to 359.9 0.0 to 100.0 0.0 to 108.0 White, Yellow, Cyan, Green, Magenta, Red, Blue, Black Default value 0.0 0.00.0Black Mask ParameterMask Invert 6/8 Setting range On, Off On, Off Default value Off Off MaskAdj ParameterLeft TopBottomRight 7/8 Setting range −50.00 to +50.00 −50.00 to +50.00 −50.00 to +50.00 −50.00 to +50.00 Default value − 5.00 + 5.00−5.00 +5.00 Trans Parameter OutPatt 8/8 Setting range Nor, Rev Default value Nor CHR KEY Auto ParameterMarker Aspect Sample ↓ 1/3 Setting range On, Off −50.00 to +50.00 Start Default value Off 0.00 Adjust1 ParameterHue SatLumY-Infl /3 Setting r ange 0.0 to 359.9 0.0 to 100.0 0.0 to 110.0 0.0 to 100.0 Default value 354.0 100.07.00 Adjust2 ParameterHue-Rad Sat-Rad Soft Cancel 3/3 Setting range 0.0 to 100.0 0.0 to 100.0 0.0 to 100.0 0.0 to 100.0 Default value 100.0 50.000 FREEZE Status Display only FRZ: XPT:1 2 3 4 5 6 7 8 9 10 1/ Freeze P arameter Signal Select Freeze ↓ / Setting r ange IN1 to 8 Frame, Field Toggling between On and Off Default value — Frame Off 7. Setting menu table
87 MenuSub menuParameter 1 Parameter 2 Parameter 3 Parameter 4Turn F1 to select. Turn F to select. Turn F3 to select. Turn F4 to select. Turn F5 to select. DSK DSK ParameterType FillPVW 1/5 Setting range Lum, Linear Bus, Matte On, Off Default value Linear BusOff Adjust ParameterClip GainDensityInvert /5 Setting range 0.0 to 108.0 0.0 to 00.0 0.0 to 100.0 On, Off Default value 0.0 100.0100.0Off FillMatt ParameterHue SatLumLoad ↓ 3/5 Setting range 0.0 to 359.9 0.0 to 100.0 0.0 to 108.0 White, Yellow, Cyan, Green, Magenta, Red, Blue, Black Default value 0.0 0.0100.0White Edge ParameterType Width 4/5 Setting range Off, Drop, Shadow 0 to 4 Default value Off EdgeCol ParameterHue SatLumLoad ↓ 5/5 Setting range 0.0 to 359.9 0.0 to 100.0 0.0 to 108.0 White, Yellow, Cyan, Green, Magenta, Red, Blue, Black Default value 0.0 0.00.0Black PinP PinP ParameterDensity PVW 1/6 Setting range 0.0 to 100.0 On, Off Default value 100.0 Off Border ParameterBorder WidthSoft /6 Setting range Off, On 0.1 to 100.0 0.0 to 100.0 Default value Off 5.00.0 BodrCol ParameterHue SatLumLoad ↓ 3/6 Setting range 0.0 to 359.9 0.0 to 100.0 0.0 to 108.0 White, Yellow, Cyan, Green, Magenta, Red, Blue, Black Default value 0.0 0.0100.0White Position ParameterX-Pos Y-PosSize 4/6 Setting range −50.00 to +50.00 −50.00 to +50.00 0.00 to 100.00 Default value 0.00 0.005.00 Trim P arameter Trim Manual 5/6 Setting range Off, 4:3, Manual Free, Pair Default value Off Free TrimAdj ParameterLeft TopBottomRight 6/6 Setting range −50.00 to +50.00 −50.00 to +50.00 −50.00 to +50.00 −50.00 to +50.00 Default value −40.00 +40.00−40.00+40.00 7. Setting menu table
88 MenuSub menuParameter 1 Parameter 2 Parameter 3 Parameter 4Turn F1 to select. Turn F to select. Turn F3 to select. Turn F4 to select. Turn F5 to select. IN/OUT Input ParameterSignal FSMode ↓ AnaGain 1/11 Setting range IN1 to 8 On, Off Normal, UC, AUTO, D by D −30 to +30 Default value — OnNormal0 Output ParameterSignal Assign /11 Setting range OUT1 to 6 PGM, PVW, AUX, Multi, KEYOut Default value — Ref ParameterSync ↓ BBSetup GenLock 3/11 Setting range BBST, BBAD, TRI, INT 0IRE, 7.5IRE Locked, UnLock Default value BBST 7.5IRE — OutPhs ParameterSystem H-Phase V-Phase 4/11 Setting range 0H, 1H −13 0 to +1319 −100 to +100 Default value 1H 00 OSD ParameterOSD Select 5/11 Setting range On, Off PVW, Multi Default value On PVW Multi ParameterSplit CharPosSignal 6/11 Setting range 10SPL-A, 10SPL-B, 4SPL, 8SPL-A, 8SPL-B On, Off 1 to 8 (1 to 4) (1 to 6)IN1 to 8, FMEM1, FMEM , CBGD Def ault value 10SPL-A On — — Anci ParameterVAnci E.Audio 7/11 Setting range On, Off On, Off Default value Off Off DVIIn ParameterSignal ModeScaleAuto ↓ 8/11 Setting range IN5 to 8 Dig, Ana Fit-V, Fit-H, Full Black, White, Init Default value — DigFit-VBlack DVIPhs ParameterSignal ClkPhsH-PosV-Pos 9/11 Setting range IN5 to 8 −16 to 15 −100 to 100 −100 to 100 Default value — 000 DVIOut ParameterSignal Mode ↓ Size ↓ Scale ↓ 10/11 Setting range OUT3, OUT5 Dig, Ana Auto, XGA, WXGA, SXGA, WSXGA+, UXGA, WUXGA Fit-V, Fit-H, Full, 5:4 (“5:4” can be selected when SXGA has been selected as the Size item setting.) Default value — DigAutoFit-V UpConvt ParameterSignal Scale ↓ MovDet ↓ Sharp ↓ 11/11 Setting range IN5 to 8 SQ, EC, LB 1 to 5 1 to 5 Default value — SQ33 7. Setting menu table
89 MenuSub menuParameter 1 Parameter 2 Parameter 3 Parameter 4Turn F1 to select. Turn F to select. Turn F3 to select. Turn F4 to select. Turn F5 to select. MEMORY PSMEM ParameterMode NO.SelXPTExec ↓ 1/3 Setting range Store, Recall, Clear 1 to 10 Disable, Enable Default value — — — — FMEM ParameterSignal Store Exec ↓ /3 Setting range AUX FMEM1, FMEM Def ault v alue — — — SDCard ParameterMode ↓ Select SaveFile Ex ec ↓ 3/3 Setting range Load, Save, Init, No Card FMEM1, FMEM , System HS070531100000 Def ault value — — — XPT XPTStats Display only SIG:B 1 2 3 4 5 6 7 8 G XPT:1 2 3 4 5 6 7 8 9 10 1/3 XPTAsign ParameterXPT Signal /3 Setting range 1 to 10 IN1 to 8, Black, CBGD, CBAR, FMEM1, FMEM , None Def ault value — — — XPTSwch ParameterTiming 3/3 Setting range Any , Field1, Field Default value Any SYSTEM Format ParameterMode ↓ 1/14 Setting range 1080/59.94i, 1080/50i, 7 0/59.94p , 70/50p, 480/59.94i, 576/50i Default value 1080/59.94i System ParameterBusMode LCD-BL EditEN /14 Setting range A/B, PGM/PST On, Off On, Off Default value PGM/PST On On Button ParameterUSER1 USER2FTB 3/14 Setting range PinPPVW, DSKPVW, EditEN, GPIEN, OSD PinPPVW, DSKPVW, EditEN, GPIEN, OSDFTB, KEYAuto, Disable Default value PinPPVW DSKPVW FTB 7. Setting menu table
90 MenuSub menuParameter 1 Parameter 2 Parameter 3 Parameter 4Turn F1 to select. Turn F to select. Turn F3 to select. Turn F4 to select. Turn F5 to select. SYSTEM GPI ParameterGPI1 GPI2GPIEN 4/14 Setting range AUTO, CUT, DSK, PinP, FTB, BGDAUTO, BGDCUT, KEYAUTO, KEYCUT AUTO, CUT, DSK, PinP, FTB, BGDAUTO, BGDCUT, KEYAUTO, KEYCUTON, OFF Default value AUTO DSKON Initial ParameterInit ↓ 5/14 Setting range Alarm ParameterPower Fan 6/14 Setting range Alarm, NoAlarm Alarm, NoAlarm Default value NetWork1 ParameterIP Address Sa ve ↓ 7/14 Setting range 0 to 550 to 550 to 55 0 to 55 Default value 19 168 01 NetW ork2 P arameter Subnet Mask Save ↓ 8/14 Setting r ange 0 to 55 0 to 550 to 55 0 to 55 Default value 55 55 550 NetWork3 ParameterGateway Save ↓ 9/14 Setting range 0 to 55 0 to 550 to 55 0 to 55 Default value 0 000 NetWork4 ParameterMAC Address 10/14 Display only Date ParameterYear MonthDateSet ↓ 11/14 Setting range000 to 099 1 to 1 1 to 31 — Default value — — — — Time ParameterHour MinuteSecondSet ↓ 1/14 Setting r ange 0 to 3 0 to 59 0 to 59 — Def ault value — — — — MainVer ParameterSelect Version SysVer 13/14 Setting range Soft, Control, Panel, Input, M/E Version number Version number OptVer ParameterSelect BoardVersion 14/14 Setting range IN-SL1, IN-SL , OUT -SL1, OUT-SL SDI, Analog, D VI, DVI/Ana, None Version number 7. Setting menu table