Page 21
21 The underlined values are factory preset setting values. *1 When the monitor is shipped from the factory, “USER1” – “USER5” and “FACTORY” all have the same details. *2 You cannot save or load the settings for “H POSITION”, “V PO SITION”, “PHASE” and “CLOCK” ( J page 27). *3 Factory preset settings are The U.S.A. and Canada: SMPTE-C, Others: EBU. SYSTEM CONFIG Sub menu Settings Explanation CONT./BACK. Used to select the function to be assigned to [CONTRAST/ BACKLIGHT] (a knob on the front panel)....
Page 22
22 The underlined values are factory preset setting values. *1 If these settings are changed, th e menu settings will also change. FUNCTION Sub menu Settings Explanation FUNCTION 1 – FUNCTION 5 (Factory preset settings FUNCTION1: MARKER FUNCTION2: WFM FUNCTION3: LEVEL METER FUNCTION4: PIXEL TO PIXEL FUNCTION5: PIXEL POS.) Used to select the functions to be assigned to individual buttons [FUNCTION1] to [FUNCTIO N5] (front-panel buttons). Displays the...
Page 23
23 gRestrictions on various FUNCTION settings Under the following conditions, various settings are disabled. g Operation items displayed when a FUNCTION button is used When any of the buttons, [FUNCTION1] to [FUNCTION5], is pressed, the following messages are displayed according to the operation assigned to the pressed button. •HV DELAY DELAY OFF, V DELAY, H DELAY, HV DELAY • AUTOSETUP COMPLETE: Display for completion INCOMPLETE: Display for incompletion NOT RGB-COMP. CH • GAMMA SELECT GAMMA STANDARD,...
Page 24
24 gAbout HV DELAY This displays the video blanking period. By pushing the button, you can switch through the H blanking display J V blanking display J H and V blanking display J no blanking display. g About the SUB WINDOW You can compare saved still and movi ng images by using the “SUB WINDOW” function to separate the main window into 2 displays as shown below. Depending on the settings of the “SUB WINDOW” (FULL, PART) in the “SYSTEM CONFIG” menu (J page 21) it can be switched as shown below. The...
Page 25
25 gAbout WFM You can display the wave form monitor using the “WFM” function. The display changes each time you press one of the buttons, [FUNCTION1] to [FUNCTION5] ( J page 22), assigned with the [WFM] function (To use the “WFM” function, you must assign it to one of the [FUNCTION1] to [FUNCTION5] buttons). Even if “WFM” has turned ON”, “WFM” is not displa yed when using the “PIXEL TO PIXEL” function, “YP BPR/RGB” set in “INPUT SELECT” menu is “RGB-COMP.” or “RGB-VIDEO”, or using the “SUB WINDOW”...
Page 26
26 The “GPI CONTROL” item is used to set enable/disenable of all GPI functions, and assigns functions to each of the GPI terminal pins (J page 30). The underlined values are factory preset setting values. Note: Please be aware that the following can not be performed. •“SD ASPECT” operation when input signal is HD or PC • “SCAN” operation when the input signal is PC • “GAMMA SELECT” operation when the input signal is PC • “RGB SYNC” operation when anything other than “RGB-VIDEO” is selected in “YP...
Page 27
27 The underlined values are factory preset setting values. *1 “AUTO” is set when the monitor is shipped from the factory, but if there are concerns about noise etc. from outside the input signal, we recommend assigning specific format. g COMP. The following menus are switched by selecting “RGB-COMP.” in “YP BPR/RGB” in the “INPUT SELECT” menu. The underlined values are factory preset setting values. *1 “EXECUTING” is displayed while “AUTOSETUP” is be ing executed, and “COMPLETE” is displayed when...
Page 28
28 g “PHASE” and “CLOCK” factory preset setting values Adjusting the speaker output. The underlined values are factory preset setting values. *1 When speaker output set in “INPUT SELECT” menu is analog, the level meter does not move regardless of its display status. FORMAT CLOCK PHASE FORMAT CLOCK PHASE 640x400(70Hz) 800 18 1024x768(60Hz) 1344 1 640x480(60Hz) 800 18 1024x768(70Hz) 1328 21 640x480(75Hz) 840 10 1024x768(75Hz) 1312 9 640x480(85Hz) 832 5 1024x768(85Hz) 1376 9 800x600(60Hz) 1056 27...
Page 29
29 Main Menu (continued) The underlined values are factory preset setting values. *1 The menu can be displayed when the lock is engaged. The only menu setting that can be changed when the lock is engaged is the “CONTROL/LOCAL ENA.” item. When the lock is engaged, the picture adjusting knob is disabled. Operations when the lock is engaged follow the settings in “LOCAL ENA.”. When the lock is engaged, the volume knob can be operated ( J page 9, ). When the lock is engaged, the key mark is...
Page 30
30 REMOTE Specifications REMOTE operation is possible on this monitor using the GPI/RS-232C terminal. Each of the items in the GPI screen ar e compatible with the following terminals. You can assign functions to each terminal in the menu GPI screen ( J page 26). The functions assigned to each terminal operate when the GND (5 Pin) is connected (ON) or open (OFF). gOperating conditions Level operation: operates when GND is connected. Edge operation: operates when GND changes from open to connected....