Have a look at the manual Panasonic Memory Card SRecorder AG-AC90P AG-AC90PJ AG-AC90PX Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
- 31 - 1Change the mode to .≥Extract the LCD monitor. 2Press the button.≥When photos are being recorded, the remaining recordable number of photos and the photo operation display are displayed. ∫ About the screen indications while recording still pictures Recording Recording still pictures Size of still pictures R3000 Remaining number of still pictures Still picture indication AMode switch R3000 R3000 R3000M3 M3 AG-AC90-VQT4M99_mst.book 31 ページ 2012年9月25日 火曜日 午後12時6分
- 32 - ∫ About picture size The number of recording pixels changes depending on the [REC FORMAT] ( l89) and the [ASPECT] ( l92). ≥It is possible to record still pictures while recording motion pictures. (Simultaneous recording) ≥ It is recommended to use a tripod when recording under low light conditions because the shutter speed becomes slow. ≥ If simultaneous recording is used while recording a motion picture, the remaining recordable time will shorten. If the unit is turned off or the mode switch operated, the remaining recordable time may lengthen. ≥ The 16:9 still pictures recorded using this unit may be cropped at the edges when printed. So, be sure to check before printing in the store or on your printer. ≥ Please refer to page 11 8 about approximate number of recordable pictures. Recording formatASPECTPicture size [PS 1080/60p], [PH 1080/60i], [PH 1080/30p], [PH 1080/24p], [HA 1080/60i], [HE 1080/60i] - 2304k1296 [SA 480/60i] 16:9 4:3 1728k1296 M3 2.2M AG-AC90-VQT4M99_mst.book 32 ページ 2012年9月25日 火曜日 午後12時6分
- 33 - ≥ is displayed in the Manual Mode. ≥ The following modes appropriate for the condition are set just by pointing the unit to what you want to record in the Intelligent Auto Mode. * When [AUTO SLOW SHTR] ( l93) is [OFF], Low Light Mode will not be entered. ≥Depending on the recording conditions, the unit may not enter the desired mode. ≥ In the Portrait, Spotlight, or Low Light Mode, the face will be surrounded by a white frame when detected. In the Portrait Mode, a subject that is bigger and close to center of the screen will be surrounded by an orange frame. ( l98) ≥ Faces cannot be detected depending on the recording conditions, such as when faces are of certain sizes or at certain tilts or when digital zoom is used. Recording Intelligent Auto Mode/Manual Mode ModeEffect Portrait Faces are detected and focused automatically, and the brightness is adjusted so it is recorded clearly. SceneryThe whole landscape will be recorded vividly without whiting out the background sky, which may be very bright. SpotlightVery bright object is recorded clearly. Low light*It can record very clearly even in a dark room or twilight. NormalIn modes other than those described above, the contrast is adjusted to give a clear picture. iA/MANU switchSlide the switch to change the Intelligent Auto Mode/Manual Mode. MANU MNL AG-AC90-VQT4M99_mst.book 33 ページ 2012年9月25日 火曜日 午後12時6分
- 34 - ∫ Intelligent Auto Mode When switching to Intelligent Auto Mode, the Auto White Balance and Auto Focus operate and automatically adjust the color balance and focusing. Depending on the brightness of the subject etc., the aperture and shutter speed are automatically adjusted for an optimum brightness. ≥Color balance and focus may not be adjusted automatically depending on light sources or scenes. If so, manually adjust these settings. ( l38, 40 ) Automatic White BalanceThe illustration shows the range over which Automatic White Balance functions. 1) The effective range of Automatic White Balance adjustment on this unit 2) Blue sky 3) Cloudy sky (rain) 4) Sunlight 5) White fluorescent lamp 6) Halogen light bulb 7) Incandescent light bulb 8) Sunrise or sunset 9) Candlelight If the Automatic White Balance is not functioning normally, adjust the White Balance manually. ( l40) Auto FocusThe unit focuses automatically. ≥Auto Focus does not work correctly in the following situations. Record pictures in the Manual Focus Mode. ( l38) j Recording distant and close-up objects at the same time j Recording a subject behind dirty or dusty window j Recording a subject that is surrounded by objects with glossy surfaces or by highly reflective objects 4) 5) 6) 7) 8) 10 000K 9 000K 8 000K 7 000K 6 000K 5 000K 4 000K 3 000K 2 000K2) 1) 3) 9) AG-AC90-VQT4M99_mst.book 34 ページ 2012年9月25日 火曜日 午後12時6分
- 35 - It can be zoomed up to 12k. ≥ It can zoom up to 25 k when the [i.Zoom] is set to [ON]. ( l92) ≥ Zoom magnification can be checked in the screen display of Z00 to Z99. The value gets larger when zoomed in, and the value gets smaller when zoomed out. 99 is displayed during the i.Zoom. Ring zoom Zoom operation can be done using the zoom ring. Recording Using the zoom Zoom ring AZoom by rotating the ring. A side: Wide-angle recording (zoom out) B side: Close-up recording (zoom in) Zoom lever/Sub zoom leverT side: Close-up recording (zoom in) W side: Wide-angle recording (zoom out) T T W W W W T T W W A B A B AG-AC90-VQT4M99_mst.book 35 ページ 2012年9月25日 火曜日 午後12時6分
- 36 - ∫ About the zoom speed ≥The zoom speed will vary depending on how far the zoom lever is pressed or how fast the zoom ring is rotated. ≥ Zoom speed of the sub zoom lever will vary depending on the setting of [SUB ZOOM]. ( l99) ≥ The zoom speed does not vary when operating with the wireless remote control. ≥If you take your finger off the zoom lever during zoom operation, the operation sound may be recorded. When returning the zoom lever to the original position, move it quietly. ≥ It can be focused approximately 1.2 m (3.9 feet) or further when the zoom magnification is at its maximum. ≥ It can be focused approximately 3.5 cm (1.4 q) or further when the zoom magnification is set to 1 k . Utilizing the USER buttonDigital zoom can be used by setting the USER button. ( l59) ≥ Please refer to page 55 for details about setting the USER button. AG-AC90-VQT4M99_mst.book 36 ページ 2012年9月25日 火曜日 午後12時6分
- 37 - Use the image stabilizer to reduce the effects of shake during recording. This unit is equipped with Hybrid Optical Image Stabilizer. Hybrid Optical Image Stabilizer is a hybrid of optical and electrical image stabilizer. ∫Changing Image Stabilizer Mode When set to [ON], you can further improve image stabilization for recording while walking, or holding the unit and recording a distant subject with zoom. ≥This function’s default setting is [ON]. ≥ This cannot be set when Optical Image Stabilizer is set to (setting canceled). ≥Stabilization may not be possible under strong shaking conditions. ≥ When using a tripod, we recommend that you set the image stabilizer to (setting canceled). Recording Image Stabilizer Function : [RECORD SETUP] # [HYBRID O.I.S.] # [ON] or [OFF] Optical image stabilizer buttonPress the button to turn optical image stabilizer on/off. / # (setting canceled) ≥ When [HYBRID O.I.S.] is [ON], is displayed. When [OFF], is displayed. O.I.S. MENU AG-AC90-VQT4M99_mst.book 37 ページ 2012年9月25日 火曜日 午後12時6分
- 38 - Perform focus adjustments using the focus ring. If auto focusing is difficult due to the conditions, then use Manual Focus. ≥Switch to Manual Mode. ( l33) 1Press the FOCUS A/M/ ¶ button to switch to Manual Focus.≥ It will switch to MF from AF. 2Adjust the focus by rotating the focus ring.≥The focus value can be set from MF00 (focus distance: approximately 3.5 cm (1.4 q)) to MF99 (focus distance: infinity). The larger the focus value gets, the further the position where focus is achieved. ≥ It is set to MF95 and the focus will move to infinite when the FOCUS A/M/ ¶ button is pressed and held. ≥ To return to Auto Focus, either press the FOCUS A/M/ ¶ button or set to Intelligent Auto Mode by switching the iA/MANU switch. ≥ When the distance to the subject approaches within 1 m (3.3 feet) approx., the unit switches to the macro range and or . (The unit may switch to the macro range even when the distance to the subject is 1 m (3.3 feet) or more depending on the subject.) ≥ Depending on the zoom magnification, this unit may fail to switch to the macro range, or go to a non-displayed focus value. ≥ When you perform a zoom operation in the macro range, this unit may go out of focus. Recording Focus FOCUS A/M¿ FOCUS ASSIST A FOCUS ASSIST button B FOCUS A/M/ ¶ button C Focus ring AG-AC90-VQT4M99_mst.book 38 ページ 2012年9月25日 火曜日 午後12時6分
- 39 - ∫ Focus Assist When the FOCUS ASSIST button is pressed, Focus Assist can be set. The in-focus area is displayed in red. ≥When it is pressed once more, the settings are canceled. ≥The red display does not appear on the images actually recorded. ≥ The red display does not appear on TV. Utilizing the USER buttonWhen performing Manual Focus, Push AF can be used by setting the USER button. ( l55) ≥ Please refer to page 55 for details about setting the USER button. AG-AC90-VQT4M99_mst.book 39 ページ 2012年9月25日 火曜日 午後12時6分
- 40 - Automatic White Balance function may not reproduce natural colors depending on the scenes or lighting conditions. If so, you can adjust the White Balance manually. Switch the modes of White Balance by pressing the W.B. button. * Only displayed when Manual Mode is in use. ≥To return to auto setting, either set to ATW or set to Intelligent Auto Mode by switching the iA/ MANU switch. ≥ ATW and ATW Lock can also be set to the USER button. ( l55) Recording White Balance ModeSettings AT W It will automatically adjust in accordance with the recording condition. AT W L o c k It will lock the setting for ATW. P3.2k*Preset value for studio/indoor recording (halogen lamp, etc.) P5.6k*Preset value for outdoors Ach* Bch*Setting in accordance to the recording scenes can be set. ( l41) W.B. A W.B. button AG-AC90-VQT4M99_mst.book 40 ページ 2012年9月25日 火曜日 午後12時6分