    							21
    Using Web Browser (continued)
     Mail with the contents shown below is sent when an error has occurred.
    Command port set up page
    Set the port number to be used with command control.
    Click [Detailed set up] → [Command port set up].
    1 Input the port number to be used with command control
    2 Setting update button
    1
    2 
    						
    							22
    PJLink protocol
    The network function of the projector supports PJLink class 1, and the PJLink protocol can be used to perform 
    projector setting and projector status query operations from a computer.
    Control commands
    The following table lists the PJLink protocol commands that can be used to control the projector.
    CommandControl detailsNotes
    POWRPower supply control
    Parameters
    0 = Standby
    1 = Power ON
    POWR ?Power supply status query
    Parameters
    0 = Standby 1 = Power ON
    2 = Cool-down in progress 
    INPTInput selectionParameters
    11 = RGB1  12= RGB(Scart) 13 = RGB2                        
    21 = VIDEO   22 = COMPONENT 25= S-VIDEO
    33 = HDMI 
    INPT ?Input selection query
    AV M TAV MUTE controlParameters
    30 = AV MUTE mode off
    31 = AV MUTE mode onAVMT ?AV MUTE status query
    ERST ?Error status query
    Parameters
    1st byte : Indicates fan errors, range 0 – 2
    2nd byte : Indicates lamp errors, range 0 – 2
    3rd byte : Indicates temperature errors, range 0 – 2
    4th byte : Fixed at 0
    5th byte : Indicates filter errors, range 0 – 2
    6th byte : Indicates other errors, range 0 – 2
    Definitions for each value from 0 to 2 are as follows.
    0 = No error known 1 = Warning 2 = Error
    LAMP ?Lamp status query
    Parameters
    1st digits (1 – 5 digits) : Lamp cumulative operating time
    2nd digit : 0 = Lamp off, 1 = Lamp on
    INST ?Input selection list queryThe followings are returned as parameters. 
     “11, 12, 13, 21, 22, 25, 33”
    NAME ?Projector name queryThe name set for [NAME CHANGE] in [NETWORK] is returned.
    INF1 ?Manufacturer name query“Panasonic” is returned.
    INF2 ?Model name queryAnswer the model name with either “VW330” or “VX400”
    INF0 ?Other information queryInformation such as version number is returned.
    CLSS ?Class information query“1” is returned.
    PJLink security authorization
    When using PJLink with security authorization, either of the password set for administrator privileges and the 
    password set for user privileges with Web browser control can be used as the password for PJLink (See page 16).
    When using PJLink without security authorization, set use without the password for administrator privileges and the 
    password for user privileges of Web browser control.
    For specifications regarding PJLink, refer to the Japan Business Machine and Information System Industries 
    Association website. 
    URL http://pjlink.jbmia.or.jp/ 
    						
    							23
    Control commands via LAN
    When WEB Control administrator rights password is set (Protect mode)
    Connection method
    Obtain the IP address and port number (Initial set value = 1024) of the projector and 1) 
    make a request for connection to the projector.
    Acquire the IP address from the menu screen of the projector, and the port number from the WEB control 
    page.
    IP address :Obtain from MAIN MENU → [Network] → [Network status]
    Port No. :Acquire from the WEB control “Detailed set up ” → “Command port set up” page
    There is a response from the projector.2)  
    Response data
    Data sectionBlankModeBlankRandom number 
    section
    Termination 
    symbol
    “NTCONTROL”
    (ASCII string)
    ‘ ’
    0x20
    ‘1’
    0x31
    ‘ ’
    0x20
    “zzzzzzzz”
    (ASCII code hexadecimal 
    number)
    (CR)
    0x0d
    9 bytes1 byte1 byte1 byte8 bytes1 byte
    Mode : 1 = Protect mode
    Generate a 32-byte hash value from the following data using MD5 algorithm.3)  
    “xxxxxx:yyyyy:zzzzzzzz”
    xxxxxx :Administrator rights user name for WEB CONTROL (Default user name is “admin1”)
    yyyyy :Password of above administrator rights user (Default password is “panasonic”)
    zzzzzzzz :8-byte random number obtained in Step 2
    Command transmission method
    Transmit using the following command format.
    Transmitted data
    HeaderData sectionTermination symbol
    Hash value
    (See above  
    )
    ‘0’
    0x30
    ‘0’
    0x30
    Control command
    (ASCII string)
    (CR)
    0x0d
    32 bytes1 byte1 byteUndefined length1 byte
    Receive data
    HeaderData sectionTermination symbol
    ‘0’
    0x30
    ‘0’
    0x30
    Control command
    (ASCII string)
    (CR)
    0x0d
    1 byte1 byteUndefined length1 byte
    Error response
    Error messageTermination symbol
    “ ERR1”
    “ERR2”
    “ERR3”
    “ERR4”
    “ERR5”
    “ ER R A”
    Undefined control command
    Out of parameter range
    Busy state or no-acceptable period
    Timeout or no-acceptable period
    Wrong data length
    Password mismatch
    (CR)
    0x0d
    4 bytes1 byte 
    						
    							24
    Control commands via LAN (continued)
    When WEB Control administrator rights password is not set (Non-protect mode)
    Connection method
    Obtain the IP address and port number (Initial set value = 1024) of the projector and 1) 
    make a request for connection to the projector.
    Acquire the IP address from the menu screen of the projector, and the port number from the WEB control 
    page.
    IP address :Obtain from MAIN MENU → [Network] → [Network status]
    Port No. :Acquire from the WEB control “Detailed set up” → “Command port set up” page
    There is a response from the projector.2)  
    Response data
    Data sectionBlankModeTermination symbol
    “NTCONTROL”
    (ASCII string)
    ‘ ’
    0x20
    ‘0’
    0x30
    (CR)
    0x0d
    9 bytes1 byte1 byte1 byte
    Mode : 0 = Non-protect mode
    Command transmission method
    Transmit by the following command format.
    Transmitted data
    HeaderData sectionTermination symbol
    ‘0’
    0x30
    ‘0’
    0x30
    Control command
    (ASCII string)
    (CR)
    0x0d
    1 byte1 byteUndefined length1 byte
    Receive data
    HeaderData sectionTermination symbol
    ‘0’
    0x30
    ‘0’
    0x30
    Control command
    (ASCII string)
    (CR)
    0x0d
    1 byte1 byteUndefined length1 byte
    Receive data
    Error messageTermination symbol
    “ ERR1”
    “ERR2”
    “ERR3”
    “ERR4”
    “ERR5”
    “ ER R A”
    Undefined control command
    Out of parameter range
    Busy state or no-acceptable period
    Timeout or no-acceptable period
    Wrong data length
    Password mismatch
    (CR)
    0x0d
    4 bytes1 byte 
    						
    							25
    Glossary
    ItemDescriptionsSee 
    page
    DNSAbbreviation for Domain name system. This function sets IP address of the DNS 
    server.
    7
    10
    DHCPAbbreviation for Dynamic Host Configuration Protocol. This function 
    automatically assigns IP addresses to the connected equipment. If a device with 
    the DHCP server function is present within a LAN, it automatically assigns IP 
    addresses to the connected equipment
    7
    10
    Default gatewayThe devices that are used for different network standards from yours. Default 
    Gateway enables a connection with other network, by adjusting bilateral 
    differences such as communication protocols. If no gateway is specified for the 
    IP address of access destination, data will be sent to the host set as the default 
    gateway.
    7
    10
    IP addressInternet Protocol (IP) is a protocol for distributing data, and the address 
    corresponding to the data distribution destination is called the IP address. The 
    same IP address cannot be used within the same LAN.
    7
    10
    LANAbbreviation for Local Area Network. This is a network with a relatively narrow 
    range such as inside a company.
    4
    SubnetThis limits the range of the IP addresses assigned to computers in order to 
    divide the network into a number of sections during TCP/IP connection. The 
    value used to divide the network at this time is called the subnetmask.
    7
    10
    Trademarks
    Microsoft• ® and its logos, Windows®, Windows® XP, Windows Vista®, Windows® 7, and Internet Explorer® are the 
    registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries.
    Macintosh, Mac OS and Safari are the trademarks of Apple Inc. registered in the United States and other • 
    countries.
    PJLink is a pending trademark in Japan, the United States and other countries and regions.• 
    Other company names, product names or other names noted in this manual are trademarks or registered • 
    trademarks of the respective companies. Note that ® and ™ marks are not indicated in the text of this manual.
    Notes:
    Unauthorized use or reproduction of part or all of this manual is strictly prohibited.• 
    Panasonic cannot be held liable for any effects resulting from the use of this manual.• 
    Panasonic reserves the right to revise this manual contents without notice.•  
    						
    							0ñ1111111
    10Á0ä11111111
    11
    Web Site : http://panasonic.net/avc/projector/
    © Panasonic Corporation 201 1
    S S 0 8 11 - 0 
    						
    All Panasonic manuals Comments (0)

    Related Manuals for Panasonic LCD Projector Pt Vw330 Network Operations Manual