Home > Panasonic > Camera > Panasonic Intraoral Camera Ej Ca01up Operating Instructions

Panasonic Intraoral Camera Ej Ca01up Operating Instructions

    Download as PDF Print this page Share this page

    Have a look at the manual Panasonic Intraoral Camera Ej Ca01up Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							Using with a PC
    21
    3Select the installation destination 
    folder, and click [Next].
    4Click [Install] to start the 
    installation.
    5Click [Install] to install the driver 
    software.
    6Click [Finish].
    ≥A screen asking whether to create a shortcut is 
    displayed. Click [Yes] to create a shortcut. 
    Otherwise, click [No].
    ≥ After creating a shortcut, a screen inquiring 
    whether or not to restart the computer is 
    displayed. Click [Yes] to restart immediately. 
    Otherwise, click [No].
    Uninstalling
    Use the following method to uninstall the 
    software.
    1. Select [Start] # [Control Panel]  # 
    [Uninstall a program].
    2. Select [Dental@i Viewer] and click  [Uninstall].
    3. Click [Yes] after the confirmation message  is displayed.
    Note:
    ≥ On Windows® XP, the screen shown 
    below is displayed during installation. 
    Click [Continue Anyway] to continue 
    the installation.
    Note:
    ≥ The uninstalling procedure may vary 
    depending on the PC. For details, 
    refer to the operating instructions of 
    the PC being used.
    EJ-CA01UP&EP_mst.book  21 ページ  2011年4月5日 火曜日 午前10時18分 
    						
    							22
    Connecting to a PC
    1Connect the cable of the Camera handpiece to the Cable 
    box.
    2Connect the DC plug of the AC adaptor to the Cable box.
    ≥Insert the DC plug straight into the DC IN terminal of the Cable box.
    3Connect the AC cord to the AC adaptor.
    4Insert the power plug into the electrical outlet.
    5Connect the Cable box and the PC using the supplied USB 
    cable.
    ≥Slide the Terminal cover of the Cable box in the direction of the arrow. Insert the 
    USB cable in the USB terminal. Connect the other end of the USB cable into a 
    USB terminal on the PC.
    6Turn the power to the PC on.
    7Press the POWER button on the Camera handpiece to turn the power on.
    Note:
    ≥ Connecting to a TV monitor is not available while using the Intraoral Camera with a PC.
    Note:
    ≥Do not connect anything other than the supplied USB cable to the USB terminal of the 
    Cable box.
    ≥ On Windows
    ® XP, when [Found New Hardware Wizard] screen is displayed, select [Install 
    the software automatically (Recommended)] to continue installation. If the [Hardware 
    Installation] screen is displayed midway thro ugh installation, click the [Continue Anyway] 
    button.
    0Ò0Õ
    0Ö
    0Ô
    0Ø
    0×
    0Ó
    Camera handpiece AC adaptor
    Cable box Electrical outlet
    AC cord
    USB cable PC
    EJ-CA01UP&EP_mst.book  22 ページ  2011年4月5日 火曜日 午前10時18分 
    						
    							23
    Using with a PC
    Starting the software
    Double click the desktop shortcut icon to start the software.
    ≥It is possible to start the software from the Windows start menu.
    [All Programs (Programs)]  # [Panasonic]  # [DentaliViewer] # [Dental@i Viewer]
    Read the software Operating Instructions
    Procedure: 
    From the start menu, select [All Programs (Programs)]  # [Panasonic] # [DentaliViewer]  #
    [Operating Instructions].
    For details on how to use the software, refer to the software Operating Instructions (PDF file).
    ≥ Adobe Reader is required in order to read the software Operating Instructions (PDF file).
    From the website below, download and install the Adobe Reader version that is compatible with the 
    OS that you are using.
    http://get.adobe.com/reader/otherversions/
    EJ-CA01UP&EP_mst.book  23 ページ  2011年4月5日 火曜日 午前10時18分 
    						
    							24
    Capturing images on a PC
    After Dental@i Viewer starts, the main screen is displayed on the PC. This document outlines and 
    introduces the screen related to capturing operations and button names. For details on how to 
    capture, refer to the software Operating Instructions (PDF file).
    1Press the POWER button on the Camera handpiece to turn the power on.
    ≥ The image taken with the Intraoral Camera is displayed in the image display area of the main screen.
    ≥ The Live mode icon   is displayed in the upper left of the image display area for several seconds, and 
    the auto focus icon   is displayed in the upper right of the image display area for several seconds.
    2Bring the Camera handpiece Lens close to the location that you would like to 
    capture.
    3Switch the mode and adjust focus as necessary. (P. 13, P. 14)
    4Capture the image.
    ≥The following methods are used for capturing images.
    Playing back images on a PC
    Use a PC to playback images. For details, refer to the software Operating Instructions (PDF file).
    1 Image display area
    2 Capture still picture button
    3 Capture moving picture button
    *Changes to the stop moving picture capture button   
    during moving picture capturing.
    Still pictures
    ≥ Press the Shutter button.
    ≥ Click the capture still picture button   on the main screen.
    ≥ Press the [F5] key on the keyboard.
    Moving pictures
    ≥ Click the capture moving picture button   on the main screen to start capturing, and click 
    the stop moving picture capture button   to stop.
    ≥ Press the [F7] key on the keyboard to start capturing, and press the [F7] key again to stop.
    Note:
    ≥When adjusting the color of an image, use the PC monitor to make the adjustments.
    For details, refer to the operating instructions of the PC monitor you are using.
    
    
    \b
    AF
    EJ-CA01UP&EP_mst.book  24 ページ  2011年4月5日 火曜日 午前10時18分 
    						
    							25
    Using with a TV Monitor
    Using with a PC
    Connecting to a TV monitor
    1Connect the cable of the Camera handpiece to the Cable 
    box.
    2Connect the DC plug of the AC adaptor to the Cable box.
    ≥Insert the DC plug straight into the DC IN terminal of the Cable box.
    3Connect the AC cord to the AC adaptor.
    4Insert the power plug into the electrical outlet.
    5Using the supplied Video cable, connect the TV monitor to 
    the Cable box.
    ≥Slide the Terminal cover of the Cable box in the direction of the arrow. Insert the 
    Video cable into the VIDEO OUT terminal. Connect the other end of the Video 
    cable to the video input terminal (yellow terminal) of the TV monitor.
    6Turn on the power to the TV monitor, and switch to external input.
    ≥For details, refer to the operating instructions of the TV monitor.
    7Press the POWER button on the Camera handpiece to turn the power on.
    Note:
    ≥ Connecting to a PC is not available while using the Intraoral Camera with a TV monitor.
    Note:
    ≥Do not connect the Video cable to anything other than a TV monitor. If it is connected to a 
    commercially available video selector or video printer, a normal image might not be 
    obtained.
    0Ò0Õ
    0×
    0Ö
    0Ó
    0Ô
    0Ø
    AUDIO IN
    VIDEO IN
    Video cable
    Camera handpiece
    Cable boxAC cord
    AC adaptor
    Electrical outlet
    TV monitor
    EJ-CA01UP&EP_mst.book  25 ページ  2011年4月5日 火曜日 午前10時18分 
    						
    							26
    Capturing images on a TV monitor (Still pictures only)
    1Press the POWER button on the Camera handpiece to turn the power on.
    ≥The image taken with the Intraoral Camera is displayed on the screen.
    ≥ The Live mode icon   is displayed in the upper left of the screen for 
    several seconds, and the auto focus icon   is displayed in the upper 
    right of the screen for several seconds.
    2Bring the Camera handpiece Lens close to the location that you want to 
    capture.
    3Switch the mode and adjust focus as necessary. (P. 13, P. 14)
    4Press the Shutter button to capture.
    ≥The maximum number of still pictures that can be recorded in the internal 
    memory of the Camera handpiece is 4. If 5 or more images are captured, the 
    oldest still picture data is overwritten.
    Note:
    ≥ If the Camera handpiece is turned off, the still pictures saved in the internal memory are 
    automatically deleted. The still pictures are also deleted when the power is turned off by 
    Automatic power off.
    ≥ The still pictures saved in the internal memory can not be transferred or displayed on PC.
    ≥ Image quality may differ depending on the performance of the TV monitor.
    ≥ When adjusting the color of an image, use the TV monitor to make the adjustments.
    For details, refer to the operating instru ctions of the TV monitor you are using.
    AF
    AF
    EJ-CA01UP&EP_mst.book  26 ページ  2011年4月5日 火曜日 午前10時18分 
    						
    							Using with a TV Monitor
    27
    Playing back images on a TV monitor
    1Press the MODE button to switch to Playback mode.
    Each press of the MODE button, the mode changes as follows.
    Once the mode has been switched to Playback mo de, the last captured image will be displayed.
    2Press the MODE button or LIGHT button to switch the displayed image.
    Display the prior (old) image # MODE button 
    Display the next (new) image  # LIGHT button 
    The screen switches as follows.
    MODE button
    LIGHT button
    ≥ When the displayed image is switched, the number indicating the order in which that image was captured 
    and the number of images saved in the internal memory are displayed in the upper left of the screen for 
    several seconds.
    ≥ If only 1 image has been saved, the image will not switch even if the LIGHT button is pressed. Also, even 
    when the MODE button is pressed, a 4 split-screen will not be displayed and the mode will immediately 
    return to Live mode.
    ≥ Images are displayed in a 4 split-screen in following order.
    The size of the screen parts does not change even for 2 or 3 saved images.
    To exit playback
    Press the MODE button several times until the Live mode icon is displayed.
    Live mode
    Special mode
    (Return) Playback mode
    1/4
    2/43/4 4/4
    Live mode
    Playback 
    mode
    Special 
    mode
    1/4
    2/43/4 4/4
    Live mode
    Playback 
    mode
    Special 
    mode
    34
    2nd oldest image (2/4)
    Oldest image (4/4)
    Last captured image (1/4)
    3rd oldest image (3/4)
    EJ-CA01UP&EP_mst.book  27 ページ  2011年4月5日 火曜日 午前10時18分 
    						
    							28
    Maintenance
    Daily maintenance
    CAUTION: When performing maintenance, disconnect the power plug.
    Main unit: Camera handpiece and Camera stand
    ≥Use clean gauze containing ethanol for disinfection  to wipe away the dirt. If the amount of ethanol 
    for disinfection is too great when doing this, it  might seep into the main unit from the connection 
    parts, causing the product to malfunction. Also, do not disinfect by soaking or spraying.
    ≥ When the lens surface is dirty, a clear image cannot be captured. The lens must be cleaned. Gently 
    wipe the lens surface.
    ≥ Because the quality or shape of the Camera handpiece could be altered, do not use the following 
    disinfectants, solvents, detergents, etc.
    - Chemicals containing acetone, iodine, or phenols
    - Organic solvents such as benzine and thinner
    - Detergents such as kitchen detergent
    ≥ Also, if chemicals besides those used for daily maintenance get on the product, immediately wipe 
    them away with ethanol for disinfection.
    ≥ Do not perform sterilization treatment using an autoclave or similar device. This could cause the 
    product to malfunction.
    Camera cable
    Wipe with a soft cloth that contains a neutral detergent.
    Accessories (Other than the Camera stand)
    Wipe with a dry, soft cloth. At that time, remove all connection cables from accessories that are 
    connected to the Camera handpiece, PC, or TV monitor. Remove the power plug of the AC adaptor 
    from the outlet.
    Daily check
    Check that there are no chips, cracks or dirt in the Camera handpiece, Camera cable or Camera stand.
    Do not use damaged devices.
    Before use, check that each part is operating correctly and safely. Not doing so could cause 
    unexpected accidents or malfunction.
    Setting / storage location
    Use care in selecting the setting / storage location. Not doing so could cause the product to 
    malfunction.
    ≥The acceptable ranges for ambient temperature, relative humidity, and atmospheric pressure are 
    shown below.
    ≥ Do not expose to direct sunlight for a long period of time.
    ≥ Do not place in an unstable location.
    ≥ Do not use with a base of Camera cable bent.
    ≥ When using a product that has not been used for a long period of time, you must check that it 
    operates normally and safely before use. Ambient temperature Relative humidity Atmospheric pressure
    Usage 
    conditions: 5
    eC to 35 eC
    (41 eF to 95 eF ) 10 % to 80 % 700 hPa to 1 060 hPa
    Storage and  transport 
    conditions: —10
    eC to 60 eC
    (14 eF to 140 eF ) 0 % to 90 %
    700 hPa to 1 060 hPa
    EJ-CA01UP&EP_mst.book  28 ページ  2011年4月5日 火曜日 午前10時18分 
    						
    							29
    Other
    Troubleshooting
    Even if it appears that something is malfunctioning, it might be quickly fixed with a small operation or 
    careful attention. Before ordering repairs from a dealer, check the following items.
    If the condition does not improve, contact the dealer where the product was purchased.
    If you are not sure on how to use the software, refer to the software Operating Instructions (PDF file). 
    QuestionAnswer
    The power cannot be turned 
    on ≥
    Check that the power plug is securely inserted all the way to its base 
    into the electrical outlet.
    ≥ Check whether the DC plug of the AC adaptor is securely inserted 
    into the DC IN terminal of the Cable box.
    ≥ Check that the Camera cable is securely inserted into the Cable box.
    The power turns off 
    unexpectedly ≥
    If there is no button operation for 5 minutes, the power will 
    automatically turn off. (Automatic power off)
    Time until the power is turned off automatically is different 
    depending on the status of usage.  (P. 13)
    Moving pictures do not 
    appear on the TV monitor ≥
    Check that the power plug of the TV monitor is securely inserted all 
    the way to its base into the electrical outlet.
    ≥ Check that the Video cable is securely inserted into the Cable box and 
    the TV monitor.
    Moving pictures do not 
    appear on the PC screen ≥
    Check that the main screen of Dental@i Viewer is displayed on the 
    PC.
    ≥ Check that the USB cable is securely  inserted into the Cable box and 
    the PC.
    Images are not clear ≥
    Check that the Disposable cover is not dirty.
    ≥ Check that the lens cover glass is not dirty.
    Does not work the auto 
    focus feature (Live mode) ≥
    Is FOCUS set to Auto focus mode? (P. 14)
    The mode does not switch 
    to Playback mode ≥
    When connected to a PC, there is no Playback mode.
    ≥ The image has not been saved.
    The LED light cannot be 
    turned off ≥
    In Special mode, the LED light cannot be turned off.
    EJ-CA01UP&EP_mst.book  29 ページ  2011年4月5日 火曜日 午前10時18分 
    						
    							30
    Specifications
    General
    Camera handpiece
    Cable box
    Usage conditions: 
    ambient temperature / relative 
    humidity / atmospheric pressureAmbient temperature: 5 °C to 35 °C  (41
    eF to 95 eF )
    Relative humidity: 10 % to 80 %
    Atmospheric pressure: 700 hPa to 1 060 hPa
    Storage and transport conditions: 
    ambient temperature / relative 
    humidity / atmospheric pressure Ambient temperature: —10 °C to 60 °C (14
    eF to 140 eF )
    Relative humidity: 0 % to 90 %
    Atmospheric pressure: 700 hPa to 1 060 hPa
    Protection against electric shock 
    classification Class 
    II equipment
    Applied part classification Type BF applied part
    Power consumption 
    (With the Cable box) DC 5V  0.7A
    AC adaptor input: 9.5 VA – 13.5 VA (AC 100 V – 240 V)
    Main unit dimensions237 mm 
    k 29 mm  k 36 mm (length  k width  k height)
    [9.33 q k  1.14 q k  1.42 q (length  k width  k height)]
    Mass Approx. 210g (with Camera cable) [Approx. 0.46 lbs.]
    Signal system EIA standard: NTSC color signal
    Imaging device1/6q CCD 680 000 pixels
    Effective pixels 350 000 pixels
    Lens 5-group 6-element Auto Iris installed Open F-number 4.0
    Focal length 2.1 mm (35 mm film equivalent: 39.5 mm)
    Focus method (auto)Video image contrast detection
    Focus range: 0 mm to 
    ¶ (Live mode )
    Focus method (manual) Live mode: zone focus 3 areas
    Special mode: None
    LED light
    White LED 4 lights
    Stabilization correction Still picture: High-speed electronic shutter
    Moving picture: Electronic stabilization correction
    Camera cable length
    2 m [6.6 ft]
    IP Code IPX0
    Dimensions 99 mm 
    k 54 mm  k 30 mm (length  k width  k height)
    [3.90 q k  2.13 q k  1.18 q (length  k width  k height)]
    Mass Approx. 65g [Approx. 0.14 lbs.]
    Video image output (USB connection) Standard: USB2.0 (Isochronous transfer)
    Video image output (TV connection) Standard / format: NTSC 1.0 V [P–P] 75 h
    Terminal
    CAMERASpecial jack
    USB USB Mini-B jack Hi-Speed (USB2.0)
    VIDEORCA pin jack
    DC INDC jack (DC 5 V)
    EJ-CA01UP&EP_mst.book  30 ページ  2011年4月5日 火曜日 午前10時18分 
    						
    All Panasonic manuals Comments (0)