Have a look at the manual Panasonic Intraoral Camera Ej Ca01up Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Safety Precautions Using with a PC Preparation Using with a TV Monitor Other Operating Instructions Intraoral Camera Model No. &+$61 ≥ Please read these instructions carefully before using this product, and save these instructions for future use. ≥ The information contained in the Safety Precautions (P. 4 – P. 7) is important for the safe and reliable operations of the product. Read and understand the information thoroughly before attempting to set up and operate the product. ≥ Compliant with medical safety standards This design complies with the UL 60601-1 and EN 60601-1 safety standards, meeting the requirements for use in the medical field. Customer’s Record The serial number of this product can be found on the Logo sheet of Camera handpiece. You should note this serial number in the space provided below and retain this book, plus your purchase receipt, as a permanent record of your purchase to aid identification in the event of theft or loss, and for Warranty Service purposes. Model NumberSerial Number EJ-CA01UP&EP_mst.book 1 ページ 2011年4月5日 火曜日 午前10時18分
2 Introduction This Intraoral Camera captures and displays inside of the patient’s mouth. This product achieves accurate color reproducibility inside the mouth, and it helps you to capture clear images the first time around with its auto focus and stabilization correction features. The product is intended to be used to assist in providing explanations to your patients. Captured pictures are not intended to be used for an image diagnosis. Connect this product to a PC or a TV monitor. Connecting to a PC Use the Dental@i Viewer software on the CD-ROM (supplied) to browse and record still pictures or moving pictures. Still pictures can also be printed by connecting a printer to the PC. Connecting to a TV monitor Use the operation button of the Camera handpiece to capture or to playback images. There is a 4 split-screen that allows multiple still pictures to be displayed simultaneously during playback. Note . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . To the customer: This product is a medical device, and the user must be completely familiar with its operation. Read thoroughly each of the items in the Operating Instructions. To the dealer:After attaching the product, be sure to adequately explain each of the items in these Operating Instructions to the customer to ensure safety. This product is intended to only dental treatment US Federal law restricts this device to sale by or on the order of a ____ ”, the blank to be filled with the word “physician ”, “dentist ”, “veterinarian ”, or with the descriptive designation of any other practitioner licensed by the law of the State in which he practices to use or order the use of the device. EJ-CA01UP&EP_mst.book 2 ページ 2011年4月5日 火曜日 午前10時18分
3 Using with a PC Safety Precautions Preparation Using with a TV Monitor Other Table of Contents Read “ Safety Precautions ” (P.4 – P.7) thoroughly before use. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Safety PrecautionsSafety Precautions (These must be observed) . . . . . . . . . . . . . . . 4 Information for your safety . . . . . . . . . . . . . . 8 PreparationBefore using . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Optional Accessories . . . . . . . . . . . . . . . . . . . . 12 Part names and functions. . . . . . . . . . . . . . . . 13 Product display symbols . . . . . . . . . . . . . . . . . 16 Fitting / Removing the Disposable cover . . . . . . . . . . . . . . . . . . . . . . . 17 Using with a PCInstalling the software . . . . . . . . . . . . . . . . . . 19 Connecting to a PC . . . . . . . . . . . . . . . . . . . . . 22 Starting the software . . . . . . . . . . . . . . . . . . . 23 Capturing images on a PC . . . . . . . . . . . . . . . 24 Playing back images on a PC . . . . . . . . . . . . . 24 Using with a TV MonitorConnecting to a TV monitor . . . . . . . . . . . . . . 25 Capturing images on a TV monitor (Still pictures only) . . . . . . . . . . . . . . . . . . . . . 26 Playing back images on a TV monitor . . . . . . 27 OtherMaintenance . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . 29 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . 30 EMC Relevant Information . . . . . . . . . . . . . . . 32 When using the product with a PC For details on how to use the product when it is connected to a PC, refer to the software Operating Instructions (PDF file). EJ-CA01UP&EP_mst.book 3 ページ 2011年4月5日 火曜日 午前10時18分
4 Safety Precautions (These must be observed) The following symbols describe the need to observe certain content in order to prevent human injury or damage to property. ?These describe and classify the degree of injury or damage that occurs with incorrect use. ? The following symbols describe content to be observed. (The following symbols are examples.) Equipment connected to this product must conform to IEC standards ( i.e. IEC 60601-1 for Medical electrical equipment, IEC 60950-1 for Information technology equipment, IEC 60065 for Audio, video and similar electronic apparatus). In addition, the combination and installation shall conform to IEC 60601-1. Any person who connects this product is responsible for ensuring that the system conforms to IEC 60601-1-1. To conform to IEC 60601-1, equipment connected to this product should be connected to the power supply via an isolation transformer and have at least basic insulation. When connecting to other devices, there is a risk that the leakage current may increase. If there is anything that you do not understand, please contact the dealer where this product was purchased. WARNINGThis indicates “ content that involves a risk of serious injury or death ”. CAUTIONThis indicates “ content that involves a risk of injury or damage to property ”. This indicates “content that must NOT be performed ”. This indicates “content that MUST be performed ”. WARNING Use the Intraoral Camera after fitting the specified Disposable cover. Using the Intraoral Camera without fitting the specified Disposable cover could cause infection, device breakage and accidental ingestion of broken parts. Use a new Disposable cover for each patient. Reusing the Disposable cover could cause infection. Before and after using the product, wipe it with gauze or a similar material containing ethanol for disinfection. Using the product in an unsanitary condition could cause infection. Do not use a torn Disposable cover. If you use a torn Disposable cover, it may cause infection or the Camera handpiece malfunction. Do not use a damaged Camera handpiece. This could cause accidental ingestion of damaged parts or electric shock. EJ-CA01UP&EP_mst.book 4 ページ 2011年4月5日 火曜日 午前10時18分
5 Safety Precautions WARNING In the following situations, stop using it and disconnect the power plug; — smoke rise from the product, — the product is abnormally hot, — the product smells burnt, — abnormal noise is heard from the product, — if water or foreign bodies get inside the product, — the external case of the product is damaged. Continuing to use the product could cause fire or electric shock. ≥ Use an electrical outlet for the power plug that allows the plug to be easily reached by hand. If there is lightning or thunder, do not touch the product or the devices to which it is connected (PC, TV monitor, power plug). This could cause electric shock. Only the included AC adaptor (LSEQ0879) and AC cord (K2CA2YY00116) should be used. Using an AC adaptor other than the one supplied with this product could cause electric shock, smoke and fire. Do not use in excess of the rating for the electrical outlet or wiring device. Exceeding the rating by using too many plugs in the same outlet or wiring device could cause a fire due to heat. Do not damage the AC cord, AC adaptor, Camera cable, USB cable, or Video cable. (Do not scratch, modify, put near hot devices, forcibly turn, twist, tug, place heavy items upon, or knot). Using these when damaged could cause fire, electric shock or short-circuiting. ≥For repairs of the cord or cable, please contact your dealer. Do not directly touch the product for a long period of time with the power turned on. The temperature of the LED light exceeds 41 °C (after several minutes of use). In order to prevent burns caused by heat, be careful not to let the LED light part continuously touch the inside of the patients mouth. Direct, prolonged contact with the hot parts of the product could cause low-temperature burns*. * Persons that have poor blood flow (vascular disorders, blood circulation impairment, diabetes, high blood pressure) or persons that have weak skin sensation, etc. tend to get low-temperature burns. EJ-CA01UP&EP_mst.book 5 ページ 2011年4月5日 火曜日 午前10時18分
6 Safety Precautions (These must be observed)–Continued WARNING When the LED light of the product is illuminated, do not look directly into the LED light from close-up, and do not shine it in a persons eyes. This product uses IEC 60825-1 class I LED. Intense light could hurt the eyes. Do not use this product near persons that use pacemakers and other similar devices. The radio waves from this product could affect the operation of pacemakers, etc. Do not use the Camera handpiece when it is wet. This could cause electric shock or product malfunction. Do not pour water on or wet the product. Water getting inside the product could cause fire, electric shock, or product malfunction. If water gets inside the product, contact your dealer. Do not connect or disconnect the power plug with wet hands. This could cause electric shock. Do not disassemble or modify the product. The inside of the product contains high-voltage parts that could cause electric shock. ≥ Order repairs and inspections of the inside of the product from your dealer. Securely insert the power plug into the outlet. An incompletely inserted plug could cause electric shock or fire due to heat. ≥Do not use damaged plugs or loose electrical outlets. Periodically remove dust and other particles from the power plug. If dust or other particles collect on the plug, humidity, etc. could impair insulation and cause a fire. ≥Disconnect the power plug and wipe with a dry cloth. EJ-CA01UP&EP_mst.book 6 ページ 2011年4月5日 火曜日 午前10時18分
7 Safety Precautions CAUTION When performing maintenance or when the product is not to be used for a long period of time, disconnect the power plug to ensure safety. Leaving or storing while plugged in could cause insulation degradation, short-circuiting, etc., which could cause a fire. Do not place the product in an unstable location (On an uneven table or an incline, etc.). If the product falls, this could cause injury or product malfunction. When disposing of this Intraoral Camera, you must obey the laws applicable in your area and country and comply with the regulations of your hospital. EJ-CA01UP&EP_mst.book 7 ページ 2011年4月5日 火曜日 午前10時18分
8 Information for your safety General ≥The switching power supply is intended use for medical electrical equipment purpose, not direct to contact to patient. ≥ Please read these safety instructions carefully. ≥ Please keep this Operating Instructions for later reference. To prevent the damage ≥Do not drop or knock this product or put a lot of pressure on it. This may damage this product. ≥ Do not expose this product to excessive heat or direct sunlight as to avoid the risk of fire. ≥ Handle this product with care. Rough handling will damage its internal components. Use this product in the appropriate position ≥For pluggable equipment, the socket outlet shall be installed near this product and shall be easily accessible. ≥ To avoid risk of electrical damage, keep this product away from fluids and chemicals. ≥ Do not use this product near inadequately shielded medical devices. ≥ Do not use this product near electromagnetic equipment, radio transmitters or high voltage lines. For cleaning or storage ≥Please disconnect this product from AC outlet before cleaning. Do not use liquid or sprayed detergent for cleaning. Use moisture sheet or cloth for cleaning. ≥ Please keep this product from humidity. Contact to the dealer ≥Do not remove any parts of this product. Contact an authorized dealer in your area. ≥ If one of the following situations arises, get this product checked by service personnel: - The AC cord or plug is damaged. - Liquid has penetrated into this product. - This product has been exposed to moisture. - This product has not worked well or you can not get it work according to Operating Instructions. - This product has dropped and damaged. - If this product has obvious sign of breakage. EJ-CA01UP&EP_mst.book 8 ページ 2011年4月5日 火曜日 午前10時18分
9 - For U.S.A. - FCC STATEMENT: Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential inst allation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular inst allation. If this equipment does cause harmful interference to radio or television reception, wh ich can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: ≥ Reorient or relocate the receiving antenna. ≥ Increase the separation between the equipment and receiver. ≥ Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. ≥ Consult the dealer or an experienced radio / TV technician for help. FCC Caution: To assure continued compliance, follow the attached installation instructions and use only shielded interface cable with ferrite core when connecting to computer or peripheral devices. Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. Declaration of Conformity Trade Name: Panasonic Model No.: &+$61 Responsible party: Panasonic Corporation of North America One Panasonic Way, Secaucus, NJ 07094 Support Contact: Panasonic Factory Service Center Panasonic Service and Technology Company 410B Airport Road Elgin, IL 60123-9333 Attention: Intraoral Camera In the USA FOR SERVICE CALL TOLL FREE 1-800-528-6747 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful in terference, and (2) this device must accept any interference received, including interfer ence that may cause undesired operation. EJ-CA01UP&EP_mst.book 9 ページ 2011年4月5日 火曜日 午前10時18分
10 Before using Handling this product ≥Do not exert strong shocks or vibrations on the product by dropping it, hitting it, etc. Also, do not apply strong pressure to the product. This could cause the product to malfunction, impossible recording, or damage to occur to device parts such as the lens. ≥ When operating or transporting this product, hold the main part of the Camera handpiece. If the product is held dangling by grabbing the Camera cable, the Camera handpiece could hit the floor or other medical devices, causing it to become damaged or to malfunction. ≥ Do not touch the lens or terminal with hands. Also, be careful to prevent liquid and foreign materials from getting into the product from the lens or button gaps. ≥ The supplied cords and cables must be used. ≥ Do not use devices that emit electromagnetic radiation near this product. The electromagnetic radiation emitted by communication devices such as mobile phones, PHS, transceivers, etc. can affect this device and lead to glitches that cause the product to malfunction. In a clinical setting, instruct that these communication devices be turned off. ≥ Do not use lights that emit electromagnetic radiation near this product. The electromagnetic radiation emitted from an inverter operation light (film viewer, fluorescent light, etc.) could affect the image. Indemnity about recorded content ≥Panasonic does not accept any responsibility for damages directly or indirectly due to any type of problems that result in loss of recorded conten t, and does not guarantee any content if recording does not work properly. EJ-CA01UP&EP_mst.book 10 ページ 2011年4月5日 火曜日 午前10時18分