Home > Panasonic > Chair/Seating > Panasonic Household Massage Lounger Ep1080 Operating Instructions

Panasonic Household Massage Lounger Ep1080 Operating Instructions

    Download as PDF Print this page Share this page

    Have a look at the manual Panasonic Household Massage Lounger Ep1080 Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							English	1
    Español	S1
    Operating	Instructions
    Instrucciones de Uso
    Sillón de Masaje Doméstico
    Household 	Massage 	Lounger
    Model No./Nº de Modelo  EP1080
    Before operating this unit, please read these instructions completely.
    Antes de utilizar esta unidad, lea compleatamente estas instrucciones y \
    guárdelas para referencia futura. 
    						
    							1
    English	IMPORTANT	SAFETY	INSTRUCTIONS
    Basic precautions should always be followed when using an electrical unit, including the following.
    Please ensure that you read all instructions before using the Household Massage Lounger.
    DANGER – To reduce the risk of electric shock:
      1.  Always unplug this unit from the electrical outlet immediately after using and before cleaning.
    WARNING – To reduce the risk of burns, fire, electric shock, or injury to persons:
      1.  Always insert the power plug all the way into the outlet to reduce the risk of short-circuit and fire.
      2.  The unit should never be left unattended when plugged in. Always unplug the unit when not in use.
      3.  The unit is not to be used by people who cannot move or communicate on their own.
      4.  Only use the unit for the purpose described in these instructions.
      5.  Do not stand on the unit.
      6.  Do not use any accessories other than those recommended by the manufacturer.
      7.  Always return the seat to the upright position. Keep children away from the unit.
      8.  Never operate the unit if it has a damaged power cord or plug. Return the unit to the nearest authorized service 
    center if it is not working properly, if it has been dropped or damaged, or if it has been immersed in water. 
      9.  K eep po
    
    wer cords away from heated surfaces. Do not carry the unit by the power cord.
    10.  Never block the air openings during operation and make sure that all air openings are kept free of lint and hair, 
    etc. Do not drop or insert anything into any of the openings of the unit.
    11.  Do not use the unit on top of heating appliances, such as electr
    
    ic carpets, etc. Do not operate the unit under 
    blanket or pillow. Excessive heating can occur and cause fire, electric shock, or injury to persons.
    12.  Do not use the unit in bathrooms or other damp or humid places as this m\
    ay cause electr
    
    ic shock or cause the 
    unit to malfunction. Do not spill water, etc. onto the controller.
    13.  Do not use the unit outdoors.
    14.  Do not use or oper
    
    ate where aerosol spray products are being used or where oxygen is being administered.
    15.  When unplugging the unit, turn off all controls before removing the plug from power outlet. Do not use the unit 
    with a transformer as this may lead to malfunction or electric shock. 
    16.  Connect this unit to a properly g
    
    rounded outlet only. See Grounding Instructions.
    SAVE	THESE	INSTRUCTIONS	 
    						
    							2
    English
    	SAFETY	PRECAUTIONS
    WARNING:	To	avoid	the	risk	of	injury:
      1.  Persons with any of the conditions listed below or who are undergoing medical treatment or suffer from medical 
    conditions should consult with their physicians before using the unit:
    a)  Pregnant w
    
    omen, people who are ill, in poor physical shape.
    b)  People suffering from back, neck, shoulder, or hip pain.
    c)  People who have a pacemaker, defibrillator, or other personal medical devices prone to electronic 
    interference.
    d)  P
    
    eople suffering from heart disease.
    e)  People who are prohibited from receiving massage by a physician due to thrombosis or aneurism, acute 
    varicose veins, or other circulatory disorders.
    f)  P
    
    eople with irregular curvatures of the spine.
      2.  This unit should not be used by children. Remove the key when not in use and store out of reach of children.
      3.  Sit down slowly after checking the position of the massage heads. Never put any part of your body between the 
    massage heads as the squeezing action of the massage heads may cause injury. Never put your fingers or feet 
    in the gap between the backrest and seat, the backrest and the armrest, or the seat and cover under the 
    armrest.
      4.  Do not use the unit against bare skin. 
    
    While thin clothing may increase effectiveness, exposing the skin directly 
    to the massager may irritate the skin.  
    Do not use the unit while wearing anything hard on your head like a hair accessory, etc. Do not use the unit for 
    massaging the head, abdomen, front neck, elbows or knees.  
    Do not use excessively strong massage action on the back of the neck.
      5.  When using the massager, use the Nec
    
    k Roller Position button to adjust the massage heads to the correct 
    position. You can adjust the shoulder position in this way in the pre-programs and Rolling in the manual 
    operation. 
    Failure to align the shoulder position correctly can lead to injury. 
      6.  Do not stretch the back m
    
    uscles for more than approximately 15 minutes at a time. To avoid overstretching the 
    muscles which may result in discomfort, do not use the unit for more than 5 minutes when first using it. You can 
    gradually increase the duration and strength of the massage as you become used to it.  
    Do not massage any one point f
    
    or more than 5 minutes at a time.  
    Excessive massaging can overstimulate the muscles and nerves and result in an adverse effect.  
    To prevent excessive massaging, do not use the massager for more than a total of 15 minutes each session.  
    After approximately 15
    
     minutes, the massage heads will be retracted and stop moving.  
    The back cushion can be removed if you want to experience a stronger back massage. Exercise extreme care 
    when you use this mode in order to avoid back pain or injury. Use only for short periods of time (no more than 
    15 
     minutes). Reinstall the back cushion if you want to restore to normal massage intensity.
      7.  While using the massager, if you start feeling sick or if the massage seems painful, stop using it immediately. 
    While using the massager, if the pressure seems too strong, the movement of the massage heads can be 
    stopped at any time by pressing the Quick Stop button.
      8.  Do not go to sleep while using the unit. Do not use the unit after dr
    
    inking alcohol. 
      9.  When the seat back is in a reclined position, do not sit on it or sit with your legs resting on the headrest.
    10.  Do not allow children or pets to play on or around the unit, especially during operation. 
    11.  Do not unplug the unit or turn it off during operation. Unplug the unit immediately if there is a power outage. 
    12.  Be sure to start on the gentle massage program if using the massager for the first time. The shiatsu massage is 
    stronger and should be enjoyed after one has gotten accustomed to the chair.
    13.  Do not allow children to pla
    
    y on this mechanized furniture or operate the mechanism. Always leave in an upright 
    and closed position. Keep hands and feet clear of mechanism. Only the occupant should operate it.
    14.  Alwa
    
    ys raise the back cushion to check that the fabric of the unit itself has not been ripped before using the unit. 
    Please also check other areas to ensure that the fabric has not been ripped. No matter how small the rip, if you 
    find one then immediately stop using the unit, unplug the power cord and have the unit repaired at an 
    authorized service center. 
    						
    							3
    English	OPERATING	PRECAUTIONS
    WARNING:	To	avoid	damaging	the	chair, 	follow	these	precautions:
     1.  The chair is designed for a maximum user weight of 264 lbs (120 kg). Exceeding the maximum weight may 
    cause permanent damage to the massage mechanism and/or other components of the un\
    it. Any such damage 
    is deemed to be user abuse and is not covered under the Limited Warranty.
      2.  Do not sit on or drop the controller.
    
     Do not pull the controller cord or the power cord. Be careful not to catch the 
    cord of the controller between the armrest and the chair back.
      3.  Do not treat the chair roughly, tur
    
    n the chair on its side, turn the chair over or stand on it.
      4.  Do not treat the covering roughly.
    Keep sharp or pointed objects away from the covering of the chair. Be careful not to drop lit ashes, lit cigarettes 
    or matches on the chair.
    Exposure to direct sunlight can cause fading or a change in color of the covering.
      5.  If the massager functions abnormally
    
    , immediately turn off the power and have the massager checked by an 
    authorized service center.
      6.  Do not repeatedly operate an
    
    y switch at short intervals. Such action may cause the switch to malfunction.
      7.  Some noise may be heard coming from the massager while in use. This is due to the structure of the massager 
    and is normal.
      8.  Make sure there are no obstacles behind the chair bef
    
    ore reclining it. The chair can be reclined to a maximum 
    angle of 170˚. If the back hits a wall or pillar, the chair may malfunction. Be sure to have ample space behind 
    the chair. Recline the chair slowly in order to avoid contact with an obstacle.
      9.  When excessiv
    
    e pressure is applied to the massage heads, they may stop moving for safety. When moving the 
    heads up from the lowered position, one’s body weight may stop the heads’ movement. In such a case, slightly 
    raise your body and allow the massage heads to move up.
    10.  After each massage, slide the po
    
    wer switch, which is located on the right side of the chair, to the “off ” position 
    and turn its lock switch to the “lock” position.
    11.  Do not sit on the chair with wet body or hair
    
    .
    12.  The unit must not be used in “wet rooms” (sauna, swimming pool) or outdoors.
    13.  Do not attempt to open or disassemble any part of the unit. Only use an authorized Panasonic servicer to fix 
    your unit. •
    • 
    						
    							4
    English
    	GROUNDING	INSTRUCTIONS
    This product must be grounded. If it should malfunction or break down, grounding provides a path of least 
    resistance for electric current to reduce the risk of electric shock. This product is equipped with a cord having an 
    equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is 
    properly installed and grounded in accordance with all local codes and ordinances.
    DANGER
    Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with 
    a qualified electrician or serviceman if you are in doubt as to whether the product is properly grounded. Do not 
    modify the plug provided with the product – if it will not fit the outlet, have a proper outlet installed by a qualified 
    electrician.
    This product is for use on a nominal 120-volt circuit and has a grounding plug that looks like the plug illustrated in 
    Figure A. Make sure that the product is connected to an outlet having the same configuration as the plug.
    No adapter should be used with this product.
    Figure AGROUNDED 
    OUTLET
    GROUNDED 
    OUTLET BOX
    GROUNDING PIN 
    						
    							5
    English
    1918 17
    20
    1
    2
    3
    5
    6
    7
    8
    9
    10
    11
    13
    14
    15
    1621
    12
    4
    14	Specification	Label
    15 	Power	Cord
    16	Power	Plug
    17	Power	Switch
    18	Lock	Switch
    19	Lock	Switch	Key
    20	Lock	Switch	Key	 Tag
    To prevent children from 
    accidentally swallowing the lock 
    switch key.
    21	Wheels •
    1
    	Pillow	
    Velcroes
    2
    	Armrest
    3
    	Controller	Holder On both the left and right side.
    4
    	Legrest
    5
    	Pillow For use when watching TV or just 
    relaxing.
    The pillow has a height 
    adjustment. (See Page 10)
    The pillow is detachable, and can 
    also be flipped over.
    6
    	Back	Cushion •
    •
    •
    • 7
    	Retracted	Position	of	Massage	
    Heads The massage heads are normally 
    retracted to the left and right in 
    the upper part of the backrest.
    8
    	Velcro	for	securing	the	controller	 cord
    9
    	Back	Cushion	Zipper The back cushion is detachable.
    10	Handle
    11	Back	Cover
    12	Backrest	Latch
    13	Safety	Precaution	Label•
    •
    	SPECIFICATIONS
    Power	Supply:
    AC 120 V 60 Hz
    Rated	current: 2.0 A
    Upper	Body	Massage
    Massage Area (Up-Down): Approx. 26.6 in. (67.5 cm)
    Massage Area (Left-Right): Distance between Massage Heads during Operation
    Approx. 2.4 in. – 7.1 in. (6.0 cm – 18.0 cm)
    Up-Down Movement Speed: Approx. 20 – 35 sec. return.
    Massage Speed: Knead:  Approx.
      20 cycles/min. – 30 cycles/min.
    Swedish:   Approx. 30 cycles/min. – 50 cycles/min. 
    Compression:  Approx. 20 cycles/min. – 30 cycles/min.
    Hawaiian:   Approx. 30 cycles/min. – 50 cycles/min.
    Soft Shiatsu:  Approx. 150 cycles/min. – 210 cycles/min.
    Tap:   Approx. 230 cycles/min. – 350 cycles/min.
    Full Roll:     Approx. 20 sec./cycle – 35 sec./cycle 
     
    [Movement range: Approx. 21.1 in. (53.5 cm)]
    Regional Roll:  
      Appro
    
    x. 7 sec./cycle – 9 sec./cycle  
    [Movement range: Approx. 4.7 in. (12 cm)]
    	PART	NAMES	AND	FUNCTIONS
    MASSAGE	LOUNGER 
    						
    							6
    English
    Reclining	Angle:	
    Backrest:  Approx.  120° – 170°
    Legrest:   Approx. 0° – 80°
    Automatic	Shut-Off: 	
    Approx. 15 min. for both upper and lower body 
    (Approx. 5 minutes for the quick massage)
    Dimensions
    When not reclined. (H × W × D):
    When reclined. (H × W × D): Approx. 43.3 in. × 29.1 in. × 42.1 in. (110 cm × 74 cm × 107 cm)
    Approx. 24.0 in. × 29.1 in. × 61.0 in. (61 cm × 74 cm × 155 cm)
    Weight	of	Unit: 	
    Approx. 121 lbs (55 kg)
    Dimensions	of	Box	(H	×	 W	
     ×	D):
    Approx. 30.7 in. × 30.3 in. × 47.6 in. (78 cm × 77 cm × 121 cm)
    Weight	in	Box: Approx. 154 lbs (70 kg)
    Maximum	User	 Weight: 	
    Appro
     x. 264 lbs (120 kg)
    Minimum	Distance	from	 Wall:
    15.7 in.
      (40 cm)
    32	Operation	Indicator
    Displays operational status.
    33	Cover
    34	Manual	Operation	buttonsThis allows you to select the 
    massage action you desire.  
    (See Page 13)
    35	Speed	Adjustment	buttonAdjusts speed of upper body 
    massage in 5 steps during 
    manual operation.
    36	Speed	Indicator
    37	Massage	Position	Adjustment	button Adjusts position of massage 
    heads during manual operation. 
    (See Page 13)
    •
    •
    •
    •
    22	OFF/ON	button
    Switches the controller on and off.
    23	Time	IndicatorDisplays time remaining before 
    end of massage.
    24	Ottoman	buttonUse this button to adjust the angle 
    of the legrest.
    25	Pre-Programs	buttons
    26	Massage	Focus	buttonsUsed to select focus of massage.
    27	Tapping	OFF/ON	button
    28	Neck	Roller	Position	button
    29	Neck	Roller	Position	Indicator
    30	Quick	Stop	buttonUsed to stop the massage 
    immediately.
    31	Reclining	buttonUse this button to adjust the angle 
    of the backrest and legrest.
    •
    •
    •
    •
    •
    •
    23
    22
    24
    25
    26
    27
    28
    29
    30
    31
    32
    33
    34
    35
    36
    37
    Cover	Closed
    Cover	Opened
    CONTROLLER 
    						
    							7
    English	SETTING	UP	THE	UNIT
    WHERE	TO	USE	THE	UNIT
    Keep	at	least	3.9	(10	cm)	away	from	the	wall.
    Approx. 	76.8	(195
    	cm)
    Approx. 	13.8	
    (35	
    cm)
    Width	approx. 	
    27.5	 (70	cm)
    Approx. 	11.8	
    (30	
    cm)
    Mat
    Area	where	legrest	
    could	touch	the	floor Area	where	unit	
    touches	the	floor Avoid places where the unit will be exposed to direct sunlight 
    for long periods of time or places where it will be exposed to 
    high temperatures, such as in front of a heater, etc., as this 
    can cause discoloration or hardening of the synthetic leather.
    Placing a mat or cloth under the unit is recommended to 
    prevent floor damage. The size of the mat should be sufficient 
    [at least 47.2 in. × 27.5 in. (120 cm × 70 cm)] to cover the 
    areas where the unit touches and where the legrest could 
    touch the floor.
    Set the unit near the outlet.
     See Warning No. 11 and 12 on page 1.
    •
    •
    •
    1	UNPACK	
    THE	UNIT	AND	RAISE	 THE	BACKREST
    CAUTION
    When	raising	the	backrest, 	be	careful	not	to	cause	hands	or	feet	to	become	caught	between	the	backrest	and	the	
    backrest	latch	or	the	backrest	and	the	armrests. 
    Failure to follow this precaution may result in injury.
    •
    Check	that	there	
    is	nothing	
    around	the	unit.
    Backrest latch
    1Remove	the	top	of	the	shipping	container.
    When packed for shipping the backrest is folded forward.
    2Remove	the	packing	and	cushioning	
    materials	and	take	out	all	accessories.
    	
    3Raise	the	backrest.
    Do not connect the power cord to an electrical outlet during setup.
    Hold the backrest with both hands and lift in the direction of the 
    arrow until it comes to a stop.
    Be careful the power cord and controller are not caught in the 
    backrest.
    •
    •
    •
    •
    2	INSPECT	CONTENTS	OF	SHIPPING	CONTAINER	
    Massage	LoungerPillowBack	CushionAllen	Key	—	1
    Attachment	 Screws	—	8Lock	Switch	Key	—	1
    The lock switch key has 
    been inserted in the 
    lock switch prior to 
    leaving the factory.
    •
    Armrests 	
    —	2 
    						
    							8
    English
    3	HOW	TO	MOVE	 THE	UNIT
    Using	the	wheels	to	move	the	unit
    Grasp the legrest to move the unit when using the wheels.
    It is easier to move the unit with the massage heads 
    retracted and the backrest in the upright position.
    *   Place a mat or cloth on the floor and mo
    
    ve the unit slowly 
    to prevent floor damage. 
    •
    •
    Lifting	the	Unit
    Move the unit by having one person hold the legrest and 
    another person use the handles on the back. 
    *   Please hold the handles and leg
    
    rest securely to avoid 
    dropping the unit as it may damage your floor.
    •
    Move	it	slowly
    Legrest Wheels
    Place	your	
    fingers	inside	
    the	handle
    4	INSTALL	THE	ARMRESTS	ON	 THE	UNIT
    Front Back
    Left
    Velcro Zipper
    Convex
    FrontRear
    Round hole
    1Install	the	armrests.
    (Be careful to avoid damaging the coated fabric.)
    1	 Unfasten	the	velcro.
    2	 Unfasten	the	zipper	of	the	armrest	completely.
    3	 Check	the	side	(right	or	left)	of	the	armrest.
    	Check	
    the	direction	(front	or	back)	of	the	armrest	as	well.
    The illustration shows the left armrest. The right armrest 
    is stamped “Front”, “Right” and “Back”.
    *   The left ar
    
    mrest must be installed on the left hand side of 
    the unit.
    4	 Align
    
    	the	convex	portion	of	the	armrest	with	the	
    round	hole	on	the	unit, 	and	embed	the	armrest	on	
    the	unit. 	Avoid	catching	the	coated	fabric	between	
    them.
    If it is caught, pull it out without damaging the fabric.
    Lift up
    Secure with screws
    Allen key
    2Secure	the	armrests	with	attachment	
    screws.
    (Total of 4 positions for a single armrest)
    Lift	the	coated	fabric	on	the	side	of	the	armrest	and	
    insert	the	attachment	screw	onto	the	end	of	the	Allen	
    key, 	and	then	tighten.
    (Tighten the screws in the 4 positions lightly at first, and 
    then tighten all screws firmly.)
    *   If the scre
    
    w does not enter into the hole, tighten the screw 
    by pushing the armrest from the top.
    3Close	the	zipper	at	the	bottom	side	of	
    the	armrests.
    When closing the zipper, be careful not to twist the end of 
    the zipper.
    1	 Set
    
    	the	zipper.
    2	 Fasten	the	zipper.
    4Put	both	ends	of	the	zipper	into	the	
    inside.
    1	 Turn	in	the	edge	of	the	zipper.
    2	 Fix	the	sliding	tab	of	the	zipper	with	the	velcro. 
    						
    							9
    English
    6	ATTACHING	THE	BACK	CUSHION	AND	PILLOW
     
    1	Attach	the	back	cushion	using	the	zipper.
    2	Attach	the	pillow	using	the	velcroes.
    	BEFORE	USING	 THE	UNIT
    1	CHECK	THE	SURROUNDING	AREA
    Check	that	there	is	nothing	around	the	
    unit.
    5	FIX	THE	CONTROLLER	CORD
    Approx. 18 (45 cm) 
    Use	the	controller	cord	velcroes	to	secure	the	cord, 	leaving	approximately	18	in.	
    (45	cm)	of	free	wire.
    *   Confirm that there is a margin for the controller cord length when the backrest is reclined.
    (The illustration shows that the cord is attached to the right armrest.)
    	FOLDING	 THE	BACKREST	FORWARD	(REPACKING)
    CAUTION
    Keep	hands, 	feet,	children, 	objects,	etc.,	clear	of	openings	on	the	unit, 	including	seat,	armrests	and	legrest; 	gaps	
    between	the	unit	and	the	floor; 	and	the	backrest’s	range	of	movement	when	being	folded	forward. 
    Failure to do so could result in injury.
    The 	
    
    unit	should	not	be	turned	on	and	the	controls	should	not	be	operated	on	when	the	backrest	is	folded	forward. 
    Failure to follow these instructions could result in injury.
    The 	
    
    unit	should	not	be	climbed	on	and	objects	should	not	be	placed	on	the	unit	when	the	backrest	is	folded	
    forward.
    Failure to follow these instructions could result in damage to the unit. In 	
    
    the	interests	of	safety, 	the	backrest	should	always	be	folded	forward	by	two	persons.
    •
    •
    •
    •
    1	Press	the	OFF/ON	button	to	switch	off	the	power.
    2	Slide	the	power	switch	to	the	
    “off”	position, 	lock	it,	and	then	unplug	the	power	
    cord.
    3	Remove	the	back	cushion	and	the	pillow	from	the	unit.
    4	Remove	the	armrest	from	the	unit.
    Refer to “INSTALL THE ARMRESTS ON THE UNIT” on page 8 and remove them in 
    reverse order.
    5	Insert	a	screwdriver	into	the	opening	for	the	backrest	latch	
    approx. 	1.6	in.	(4	cm)	from	the	upper	edge	of	the	opening	
    (until	the	screwdriver	contacts	the	backrest	latch).
    6	Push	tip	of	screwdriver	downward	approx. 	1	in.	(2.5	cm)	to	
    release	backrest	latch.
    7	Pull	out	screwdriver	when	pushing	of	backrest	toward	 seat	begins.
    *Be careful to avoid catching the controller or the cord between the backrest and the seat.
    *	 It	is	recommended	that	you	move	the	unit	before	folding	the	backrest	
    (upright
    
    	
    position). 	When	the	backrest	is	folded, 	it	is	not	fixed	and	is	unstable.
    77
    55
    6
    6 
    						
    All Panasonic manuals Comments (0)

    Related Manuals for Panasonic Household Massage Lounger Ep1080 Operating Instructions