    Have a look at the manual Panasonic High Definition Plasma Display Th 103vx200 Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							
    11
    Connections
    AC cord connection and fi xing, cable  fi xing
    TH-85VX200U
    1 2 
     Note:  
     
    Two  fi xing bands are supplied with this unit. In case of securing cables at th\
    ree positions, please purchase it separately.
    – How to Unfasten the AC cord
    – Cable  fi xing bands
    Secure any excess cables with bands as required.
    AC cord of this model is 
    fi xed and connected to the main unit. No AC cord needs to be connected.
    Pass the attached cable 
    fi  xing band through the 
    clip as shown in the 
    fi  gure.  To secure cables connected to Terminals, wrap the cable 
    fi xing band around them then 
    pass the pointed end through the locking block, as shown in the  fi gure.
    While ensuring there is suf fi cient slack in cables to minimize stress (especially 
    in the power cord),  fi rmly bind all cables with the supplied  fi xing band.
    To tighten:
    Loosen the  fi xing band securing the AC cord.
    To loosen:
    To loosen:
    PullPull
    Pull
    Push the catch
    Push the catch 
    						
    							
    12
    Connections
    1 2 
    TH-103VX200U
    To secure cables connected to Terminals, wrap the cable fi xing band around them then 
    pass the pointed end through the locking block, as shown in the  fi gure.
    While ensuring there is suf fi cient slack in cables to minimize stress (especially 
    in the power cord),  fi rmly bind all cables with the supplied  fi xing band.
     Note:
     
     
    Two  fi xing bands are supplied with this unit. In case of securing cables at fo\
    ur positions, please purchase it separately.
    – Cable  fi xing bands
    Secure any excess cables with bands as required.
    Pass the attached cable 
    fi  xing band through the 
    clip as shown in the 
    fi  gure. 
    To tighten: To loosen:
    Pull Pull
    Push the catch
    Note:
    Make sure that the 
    AC cord is locked on both 
    the left and right sides.
    Push until 
    the hook clicks.
    2.
     Pull off.
    1.  Keep the 
     knob pressed.
    – AC cord 
    fi xing
    Unplug the AC cord
    Unplug the 
    AC cord 
    pressing the 
    two knobs.
    Note: 
    When disconnecting the AC 
    cord, be absolutely sure to 
    disconnect the AC cord plug 
    at the socket outlet  fi rst.
    Close
    Open
     
    Plug the AC cord into 
    the display unit.
     Plug the AC cord until it clicks.
      Fix the AC cord with 
    the clamper.
    2
    1 
    						
    							
    13
    Video equipment connection
    AUDIO OUT connection
    Connections
    COMPONENT/RGB IN
    Component/RGB Video 
    Input Terminal 
    (see 
    page 14)
    AV IN (HDMI 1-4)
    HDMI Input Terminal 
    (see page 14)PC IN
    PC Input Terminal
    Connect to video 
    terminal of PC or 
    equipment with Y, 
    P
    B(CB) and PR(CR) 
    output. 
    (see page 15)
    SERIAL
    Control the Plasma Display 
    by connecting to PC.
    (see page 16)3D SHUTTER OUT
    Connect the 3D IR 
    TRANSMITTER 
    (optional accessory).AUDIO OUT
    Connect to sound 
    equipment.
    (see below)
    LAN
    Connect to a 
    network to control 
    the unit.
    (see page 58)SLOT
    Terminal board 
    (optional accessories) 
    insert slot
    (see page 6)
    Note:
    Additional equipment and cables shown are not supplied with this set.
    Stereophonic sound code
    audio equipment
    line-in 
    						
    							
    14
    Connections
    HDMI connection
    [Pin assignments and signal names]
    1931
    4218
    Note: 
    Additional equipment and HDMI cable shown are not supplied with this set\
    .
    Pin No.Signal NamePin No.Signal Name
    1T.M.D.S Data2+11T.M.D.S Clock 
    Shield
    2T.M.D.S Data2 
    Shield12T.M.D.S Clock-
    3T.M.D.S Data2-13CEC
    4T.M.D.S Data1+14Reserved 
    (N.C. on device)
    5T.M.D.S Data1 
    Shield
    6T.M.D.S Data1-15SCL
    7T.M.D.S Data0+16SDA
    8T.M.D.S Data0 
    Shield17DDC/CEC 
    Ground
    9T.M.D.S Data0-18+5V Power
    10T.M.D.S Clock+19Hot Plug Detect
    HDMI 
    AV OUTHDMI 
    AV OUTHDMI 
    AV OUTHDMI 
    AV OUT
    HDMI cables
    DVD Player or SET-TOP-BOX
    (HDMI compatible machines only)
    HDMI cables
    COMPONENT / RGB IN connection
    , 
    Y  ,  P B ,    P R OUT 
    PR
    P B 
    Y 
    AUDIO 
    OUT 
    R
    L
    Notes: 
    •  Additional equipment and cables shown are not supplied with this set.
    •  Change the “COMPONENT/RGB-IN SELECT” setting in the “SET UP” menu to “COMPONENT” (when COMPONENT 
    signal connection) or “RGB” (when RGB signal connection). (see\
     page 44)
    •  Accepts only RGB signals with “SYNC ON G”.
    DVD Player
    Computer RGB Camcorder 
    						
    							
    Conversion adapter 
    (if necessary)Mini D-sub 15p
    RGB
    PC cable Stereo mini plug (M3)
    Audio
    Connect a cable which matches
    the audio output terminal on the computer.
    (Male)(Female)
    COMPUTER
    15
    PC Input Terminals connection
    Notes:
    •  With regard to the typical PC input signals that are described in the ap\
    plicable input signals list (see page 65), adjustment  
    values such as for the standard picture positions and sizes have already\
     been stored in this unit. You can add up to eight 
    PC input signal types that are not included in the list.
    •  Computer signals which can be input are those with a horizontal scanning\
     frequency of 15 to 110 kHz and vertical scanning  frequency of 48 to 120 Hz. (However, the image will not be displayed properly if the signals exceed 1,200 l\
    ines.)
    •  The display resolution is a maximum of 1,440 × 1,080 dots when the as\
    pect mode is set to “4:3”, and 1,920 × 1,080  dots  when the aspect mode is set to “FULL”. If the display resolu\
    tion exceeds these maximums, it may not be possible 
    to show  fi ne detail with suf fi cient clarity.
    •  The PC input terminals are DDC2B-compatible. If the computer being conne\
    cted is not DDC2B-compatible, you will need  to make setting changes to the computer at the time of connection.
    •  Some PC models cannot be connected to the set.
    •  There is no need to use an adapter for computers with DOS/V compatible M\
    ini D-sub 15P terminal.
    •  The computer shown in the illustration is for example purposes only.
    •  Additional equipment and cables shown are not supplied with this set.
    • Do not set the horizontal and vertical scanning frequencies for PC signa\
    ls which are above or below the speci fi ed 
    frequency range.
    •  Component Input is possible with the pin 1, 2, 3 of the Mini D-sub 15P Connector.
    •  Change the “COMPONENT/RGB-IN SELECT” setting in the “SET UP” menu to “COMPONENT” 
      (when COMPONENT signal connection) or “RGB” (when RGB signal connection). (se\
    e page 44)
    Signal Names for Mini D-sub 15P Connector
    Pin Layout for PC Input 
    Terminal
    Pin No.Signal NamePin No.Signal NamePin No.Signal Name
    1 R (PR/CR)6 GND (Ground)11  NC (not connected)
    2 G (Y)7 GND (Ground)12 SDA
    3 B (PB/CB)8 GND (Ground)13 HD/SYNC
    4 NC (not connected)9 +5 V DC14 VD
    5 GND (Ground)10 GND (Ground)15 SCL
    Connections
    1 
    6 
    7 
    8 
    3 
    9 
    4 
    5 
    10 
    15 14 13 12 11 
    2  
    						
    							
    COMPUTERRS-232C Straight cable
    D-sub 9p(Male)
    (Female)
    6789
    1
    3
    4
    52
    16
    The SERIAL terminal is used when the Plasma Display is controlled by a computer.
    Note:
    To use serial control for this unit, make sure to set the “CONTROL I/F SELECT” in the “NETWORK SETUP” menu to 
    “RS-232C”. (see page 55)
    Connections
    SERIAL Terminals connection
    Notes:
    •  Use the RS-232C straight cable to connect the computer 
    to the Plasma Display.
    •  The computer shown is for example purposes only.
    •  Additional equipment and cables shown are not supplied  with this set.
    The SERIAL terminal conforms to the RS-232C interface 
    speci fi cation, so that the Plasma Display can be controlled 
    by a computer which is connected to this terminal.
    The computer will require software which allows the 
    sending and receiving of control data which satis fi es  the 
    conditions given below. Use a computer application such as 
    programming language software. Refer to the documentation 
    for the computer application for details.
    Basic format for control data
    The transmission of control data from the computer starts with 
    a STX signal, followed by the command, the parameters, and 
    lastly an ETX signal in that order. If there are no parameters, 
    then the parameter signal does not need to be sent.
    Start
    (02h) 3-character
    command (3 bytes)Colon Parameter(s)
    (1 - 5 bytes) End
    (03h)
    STX C1 C2 C3 P1 P2 P3 P4
    : P5 ETX
    Notes:
    •  If multiple commands are transmitted, be sure to wait for 
    the response for the  fi rst command to come from this unit 
    before sending the next command.
    •  If an incorrect command is sent by mistake, this unit will  send an “ER401” command back to the computer.
    •  S1A and S1B of Command IMS are available only when a  dual input terminal board is attached.
    Command
    Command Parameter Control details
    PON None Power ON
    POF None Power OFF
    AVL ** Volume 00 - 63
    AMT 0 Audio MUTE OFF 1 Audio MUTE ON
    IMS None SL1
    S1A
    S1B
    YP1
    HM1
    HM2
    HM3
    HM4
    PC1
    Input select (toggle)
    SLOT input (SLOT INPUT)
    SLOT input (SLOT INPUT A)
    SLOT input (SLOT INPUT B)
    COMPONENT/RGB IN input 
    (COMPONENT)
    HDMI 1 input (HDMI1)
    HDMI 2 input (HDMI2)
    HDMI 3 input (HDMI3)
    HDMI 4 input (HDMI4)
    PC IN input (PC)
    DAM NoneZOOM
    FULL
    JUST
    NORM
    SJST
    SNOM
    SFUL
    ZOM2Screen mode select (toggle)
    ZOOM (For Video/SD/PC signal)
    FULL
    JUST (For Video/SD signal)
    4:3 (For Video/SD/PC signal)
    JUST (For HD signal)
    4:3 (For HD signal)
    H-FILL (For HD signal)
    ZOOM (For HD signal)
    With the power off, this display responds to PON command only.
    Communication parameters
    Signal level RS-232C compliant
    Synchronization method Asynchronous Baud rate 9600 bpsParity None
    Character length 8 bits Stop bit 1 bit
    Flow control -
    Signal names for D-sub 9P connector
    Pin No.
    Details
    2 R X D
    3 T X D
    5 GND
    4  • 6 Non use
    7 
    8 (Shorted in this set)
    1  • 9 NC
    These signal names are those of computer speci fi cations.
    Pin layout for SERIAL Terminal
      
    						
    							
    Connecting the AC cord plug to the Plasma Display.
    For TH-103VX200U
    Fix the AC cord plug securely to the Plasma Display 
    with the clamper. (see page 12) 
    Remote Control
    SensorPower IndicatorRight side surface
    Main Power 
    On / Off Switch
    Connecting the plug to the Wall Outlet.
    Note: 
    For TH-103VX200U
    When disconnecting the AC cord, be absolutely sure to 
    disconnect the AC cord plug at the socket outlet  fi rst.
    Press the Power switch on the Plasma Display to turn the 
    set on: Power-On. Power Indicator: Green
    Press the  button on the remote control to turn the Plasma Display off.
    Power Indicator: Red (standby) 
    Press the  button on the remote control to turn the Plasma Display on.
    Power Indicator: Green
    Turn the power to the Plasma Display off by pressing the  switch on the unit, 
    when the Plasma Display is on or in standby mode.
    Note: 
    During operation of the power management function, the power indicator t\
    urns 
    orange in the power off state.
    17
    Power ON / OFF 
    						
    							
    18
    OSD LANGUAGE
    Power ON / OFF
    English (UK)Deutsch
    Français Italiano
    ENGLISH (US)
    Русский
    OSD LANGUAGE
    Español
    Notes:Once the language is set, this screen won’t be displayed 
    • 
    when switching on the unit next time.
    After the setting, language selection can be done from 
    • 
    the SET UP menu. (see page 46)
    When 3D images will be viewed by unspeci fi ed number of 
    people or used for commercial applications, someone in 
    authority should convey the following precautions.
    These precautions should be followed in the home as well.
    To enjoy 3D images safely and comfortably, please refer 
    to the Operating Instructions for in-depth description.
    Please refrain from viewing 3D images if you do not 
    feel well or are experiencing visual fatigue.
    3D Safety Precautions
    If the power is turned on for the next and 
    subsequent times, 3D Safety Precautions 
    are displayed.
    If you do not want to show this message, set 
    to hide it in the “3D Safety Precautions” on 
    the OPTIONS menu. (see page 57) When  fi rst switching on the unit
    Following screen will be displayed when the unit is turned on for the  fi rst time.
    Select the language with the remote control. Unit buttons are invalid.
    1  Select the language.
    2  Set. 
    						
    							
    19
    Selecting the input signal
    Press to select the input signal to be played back from the equipment 
    which has been connected to the Plasma Display.
    HDMI input terminals in HDMI 1 to HDMI 4.
    Component or RGB input terminal in COMPONENT/RGB IN.*
    PC input terminal in PC IN.
    * “COMPONENT” may be displayed as “RGB” depending on the 
    setting of “COMPONENT/RGB-IN SELECT”. (see page 44)
    Input terminal in Terminal Board
    When a dual input Terminal Board is installed, “SLOT INPUT A” and “SLOT INPUT B” are 
    displayed.
    When an optional Terminal Board is installed:
    Using dedicated buttons for input selection
    Notes:
    •  Selecting is also possible by pressing the INPUT button on the unit.
    •  Select to match the signals from the source connected to the component/
    RGB input terminals. (see page 44)
    •  Image retention (image lag) may occur on the plasma display panel  when a still picture is kept on the panel for an extended period. The 
    function that darkens the screen slightly is activated to prevent image \
    retention (see page 63), but this function is not the perfect solution\
     to 
    image retention.
    INPUT MENU
    ENTER/
    HDMI1
    HDMI2
    HDMI3
    HDMI4
    COMPONENT
    PC
    INPUT
    SLOT INPUT
    HDMI1
    HDMI2
    HDMI3
    HDMI4
    COMPONENT
    PC
    INPUT
    Press to select HDMI signal terminals in HDMI 1 to HDMI 4.
    Press to select component or RGB signal terminal in COMPONENT/RGB IN.
    Press to select PC signal terminal in PC IN.
    Press to select Input terminal in Terminal Board.
    For dual input Terminal Board, you can select either input terminal 
    using A or B button. 
    						
    							
    INPUT  MENU 
    ENTER/ 
    20
    Up / Down button
    When the menu screen is displayed:
    “▲ ” : press to move the cursor up 
    “▼ ” : press to move the cursor down
    (see page 27)
    MENU Screen ON / OFF
    Each time the MENU button is pressed, the menu 
    screen will switch. (see page 27)
    Normal Viewing PICTURE SETUP SOUND POS. /SIZE
    Main Power On / Off Switch
    Enter / Aspect button 
    (see page 22, 27)
    INPUT button
    (INPUT signal selection)
    (see page 19)
    Right side 
    surface
    Power Indicator
    The Power Indicator will light.
    • Power-OFF ......   Indicator not illuminated 
    (The unit will still consume 
    some power as long as the 
    power cord is still inserted 
    into the wall outlet.)
    • Standby ...........   Red
    Orange (When “CONTROL 
    I/F SELECT” is set to “LAN”. 
    See page 55)
    • Power-ON ........ Green
    • PC POWER MANAGEMENT (DPMS)
           ...................   Orange (With PC input signal. 
    See page 46)
    Remote control sensor
    Main Unit
    Infrared transmitter for 3D 
    Eyewear
    Note:
    Do not place any objects 
    between the transmitter and 
    3D Eyewear.
    Basic Controls 
    						
    All Panasonic manuals Comments (0)

    Related Manuals for Panasonic High Definition Plasma Display Th 103vx200 Operating Instructions