    Have a look at the manual Panasonic Hd Integrated Camera Aw He2_adv Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							- 41 -
    Maintenance screen
    You can perform such operations as displaying the unit information, restoring the unit’s 
    default settings.
    A[Information] tab
    B [Other] tab
    Click the [Information] tab on the Maintenance screen.≥The model number ([Model no.]), MAC address ([MAC address]), and firmware version 
    ([Firmware version]) of the unit, and the user who last logged into the Setup screen 
    ([Access log]) are displayed.
    ∫ To check the firmware version on the camera menu
    To display the unit information on the Information screen
    [MAINTENANCE]  # [FIRMWARE VERSION]
     
    						
    							- 42 -
    Click the [Other] tab on the Maintenance screen.
    ≥
    The Other screen opens.
    You can restore the unit’s default settings. (The settings for the Network screen, the User 
    mng. screen and  the system frequen cy do not change)
    Click [Execute].≥A confirmation message is displayed. Click [OK].
    ∫ Setting Using the Camera Menu
    ≥A confirmation message is displayed. Select [YES].
    To configure the settings on the Other Screen
    [Reset to the default (Except the network settings)]
    [MAINTENANCE]  # [INITIAL SET] 
    						
    							- 43 -
    Change the image displayed on the HDMI output monitor or the web setting screen.
    Select your desired item and click [Execute].
    ≥You can also switch the display between the camera image and the color bars by pressing 
    the MODE button on the wireless remote controller or the controller.
    ≥ The color bar type differs depending on the system frequency setting.
    You can set whether to show/hide the guideline display.
    Select your desired item and click [Execute].
    ∫ Setting Using the Camera Menu
    You can check the operation time of the unit.
    ∫Setting Using the Camera Menu
    [CAM/BAR][Camera]/[Colorbar]
    [Camera]:The camera image is displayed.
    [Colorbar]:Color bars are displayed.
    [Guideline][Off]/[On]
    [MAINTENANCE]  # [GUIDE LINES]  # desired setting
    [Operation time]
    [MAINTENANCE]  # [OPERATION TIME] 
    						
    							- 44 -
    Setting Using the Camera Menu
    ≥The following items can only be set from the camera menu:
    You can set whether to show the menu screen and the status display of the White Balance 
    Setting when the unit receives a tally light-up signal.
    You can update the firmware of the unit.
    ≥ After contacting the store of purchase, save the latest firmware on to a microSD card 
    (always check the precautions of the store of purchase before following any 
    instructions).
    1 Insert a microSD card containing an update file into the card insertion portion.
    2 Select the menu.
    ≥ Follow the on-screen instructions to update.
    ≥ Do not turn off the unit while it is updating.
    ≥ Do not perform any operations while it is updating.
    You can set the resolution of the camera image displayed on the web setting screen.
    ≥  When displaying camera images of this unit in the web setting screen of other devices, 
    camera images in the web setting screen of this unit will be displayed at 320 k180/10fps.
    [OSD OFF WITH TALLY][ON]/[OFF]
    [SYSTEM]  # [OSD OFF WITH TALLY]  # desired setting
    [ON]:Hides the display.
    [OFF]:Shows the display.
    [UPDATE]
    [MAINTENANCE]  # [UPDATE]
    [IMAGE RESOLUTION][640k360]/[320k 180]
    [SYSTEM]  # [IMAGE RESOLUTION]  # desired setting 
    						
    							- 45 -
    ∫
    It is not a malfunction in following cases
    Troubleshooting
    Object seems to be 
    warped. ≥
    Object seems to be warped slightly when the object 
    moves across the image very fast, but this is because the 
    unit is using MOS for the image sensor. This is not a 
    malfunction.
    When the flash is fired 
    during shooting, only 
    the top or bottom of the 
    screen becomes lighter. ≥
    With a MOS image sensor, the shooting timing differs 
    slightly between the top left and bottom right of the 
    screen. This means that when the flash is fired, the 
    bottom of the screen will become lighter in the field 
    concerned and the top will become lighter in the next 
    field.
    This is normal and not indicative of any problem.
    Power
    ProblemCheck points
    This unit cannot be 
    turned on. ≥
    When the status display lamp is off, power is not supplied 
    or the unit is turned off.
    jCorrectly connect the AC adapter, the AC cable, and 
    the USB cable.
    j Press the power button of the unit.
    ≥ When using the wireless remote controller, select the unit 
    by pressing one of the CAM1 to CAM4 buttons, and then 
    press and hold the ON/STANDBY button for 2 seconds.
    ≥ If you turn off the unit with the power button of the unit, 
    the unit cannot be turned on by the web setting screen, 
    the wireless remote controller or controller. Press the 
    power button to turn on the unit.  
    						
    							- 46 -
    Wireless remote controller
    ProblemCheck points
    Cannot operate.≥Check if the status display lamp is lit green and the unit is 
    turned on.
    ≥ Before operating, select the unit by pressing one of the 
    CAM1 to CAM4 buttons.
    ≥ When strong light from a fluorescent lamp, a plasma 
    monitor, the sun, etc. is shining on the wireless remote 
    control signal light-sensing area, the unit may not 
    respond.
    ≥ If the status display lamp does not blink even when you 
    operate near the wireless remote control signal light-
    sensing area, the batteries of the wireless remote 
    controller are depleted. Replace the batteries.
    ≥ Set [IR Control] to [On] on the web setting screen. ( l36)
    Controller
    ProblemCheck points
    Cannot operate. ≥Check whether the status display lamp lights up green 
    and the unit is turned on.
    ≥ Before operations, press CAMERA STATUS/
    SELECTION button 1 to 5 to select the camera.
    ≥ It may be necessary to upgrade the version of the 
    controller so that the controller will support the unit. 
    Consult with your dealer.
    Web setting screen
    ProblemCheck points
    The web setting screen 
    cannot be accessed. ≥
    Check the system requirements of the web setting 
    screen.
    ≥ Use a category 5 or above LAN cable.
    ≥ When the LAN lamp is not lit, the LAN is not connected 
    correctly or the connected network is not operating 
    correctly. Check for a loose contact of the LAN cable and 
    check the wiring. 
    						
    							- 47 -
    Web setting screen
    ProblemCheck points
    The web setting screen 
    cannot be accessed.≥
    Turn on the unit or set it to Standby mode.
    ≥ Check if a valid IP address is set for the unit. 
    ≥ After changing the IP address of the unit, enter [http:// 
    Post-change IP address/] into the address bar of the web 
    browser.
    ≥ Make sure that you do not access a wrong IP address.
    j[When using Windows]
    Execute the Windows command prompt, ping [The IP 
    address set for the unit]. If a reply comes back from the 
    unit, there are no operational problems.
    If a reply does not come back, restart the unit and 
    change the IP address using the Easy IP Setup 
    Software.
    j [When using Mac OS X]
    Using the Mac OS X terminal, execute ping -c 10 [The 
    IP address set for the unit]
    If a reply comes back from the unit, there are no 
    operational problems.
    If a reply does not come back, perform the following 
    steps.
    1) Press the INIT button to initialize the network 
    settings of this unit.
    2) Start the web setting screen to configure the network  settings.
    j For information on how to start the web setting screen, 
    please read the “Operating Instructions .”
    ≥ Make sure that the HTTP port number is not set to 554. 
    For information on the HTTP port numbers supported by 
    the unit, refer to page 40.
    ≥ Check if the set IP address is not overlapping with that of 
    another device, and the set address match the network/
    subnet of the connection destination.
    j[When the personal computer is connected to the unit 
    within the same subnet]
    Set the IP addresses of this unit and the computer to a 
    common subnet. Further, cancel the “Use proxy server” 
    setting on the web browser. When accessing this unit in 
    the same subnet, it is recommended that you set the 
    address of this unit as a “Remove from proxy” address.
    j [When the unit and personal computer are connected 
    to different subnets]
    Check if the default gateway value set for the unit is 
    correct. 
    						
    							- 48 -
    The settings on the web 
    setting screen or the 
    image on the camera is 
    not updated or displayed 
    properly.≥
    The unit’s ports may be filtered by the firewall or other 
    function of the anti-virus software.
    Change the HTTP port number of the unit to a port 
    number which will not be filtered.
    [When using Windows]
    ≥ Press the [F5] key on the personal computer keyboard 
    and update the display.
    ≥ Follow the steps below to delete the temporary Internet 
    files.
    1) In Internet Explorer, click [Tools]  # [Internet Options].
    2) Click the [General] tab, and click the [Delete...] button  in [Browsing history].
    3) In the [Delete Browsing History] dialog box, select  [Temporary Internet files], and click the [Delete] button.
    4) Click the [OK] button.
    ≥ If, in the Temporary Internet Files settings, the check 
    [Every time I visit the webpage] setting is not selected for 
    [Check for newer versions of stored pages], the web 
    setting screen may not be displayed properly. Follow the 
    steps below.
    1) In Internet Explorer, click [Tools]  # [Internet Options].
    2) Click the [General] tab, and click the [Settings] button in 
    [Browsing history].
    3) In the [Temporary Internet Files and History settings]  dialog box, turn [Every time I visit the webpage] of 
    [Check for newer versions of stored pages] on.
    4) Click the [OK] button.
    [When using Mac OS X]
    ≥ Press the [Command] + [R] key on the personal computer 
    keyboard and update the display.
    ≥ Follow the steps below to delete the temporary Internet 
    files.
    1) In Safari, select [Safari]  # [Empty Cache...].
    2) Click the [Empty] button in [Are you sure you want to 
    empty the cache?] pop-up.
    Web setting screen
    ProblemCheck points 
    						
    							- 49 -
    Video
    ProblemCheck points
    No pictures are 
    displayed or the pictures 
    are disturbed.≥
    Check if the unit is correctly connected with other 
    devices.
    ≥ If your system is configured in such a way that a 
    displayed image is automatically switched in conjunction 
    with your camera selection, select the correct camera.
    ≥ Check if [Format], [Down CONV. Mode], and [System 
    Frequency] are set correctly. ( l34, 35)
    The picture is flipped 
    vertically. ≥
    Turn the middle ring portion by 180° so that the internal 
    stereo microphones are facing up.
    Multiple color bands 
    (color bars) are 
    displayed. ≥
    Switch to the camera picture. ( l5, 43)
    The menu screen is 
    displayed. ≥
    To close the camera menu, press the MENU button of the 
    wireless remote controller.
    ≥ Press and hold the CAMERA OSD button of the controller 
    for 2 seconds to exit the camera menu.
    Something is wrong with 
    the coloring of the 
    pictures. ≥
    Set the white balance to ATW (auto). If colors do not 
    appear correct even in ATW mode, perform the White 
    Balance Setting. ( l15)
    When fine lines or 
    cyclical patterns are 
    shot, flickering is seen 
    or coloring is added to 
    them. ≥
    This phenomenon occurs because the pixels are 
    arranged systematically on each image sensor. It is 
    noticeable when the spatial frequency of a subject and 
    the pixel pitch are brought into proximity so change the 
    camera angle or take other such action. 
    						
    							- 50 -
    Precautions when using a computer
    When using a computer, the symptoms described below may occur.
    If any of them occurred, follow the instructions to solve each problem.
    (The instructions describe solutions for administrators.)
    ≥Descriptions in this document are based on operation check by Panasonic Corporation.
    Possible symptoms may vary depending on platforms or operating system versions, etc.
    Operating procedures and screen are described using Windows 7 and Internet Explorer 9.0.
    ∫ When accessing the web browser, the Pop-up Blocker is displayed 
    and you cannot log in.
    ≥Follow procedures A and B below.
    A Set the popup to [Always allow] using the information bar.
    1) Click [Options for this site] on the information bar.
    2) Click [Always allow].
    B Add the IP address of the camera to trusted sites, and perform the security setting.
    1) In Internet Explorer, click [Tools]  # [Internet Options].
    2) Click the [Security] tab, and select [Trusted  sites].
    3) Select [Low] for [Security level for this zone].
    ≥ If the lower setting is sele cted, the security level 
    of personal computer will go down.
    4) Click [Sites].
    When using Windows 
    						
    All Panasonic manuals Comments (0)

    Related Manuals for Panasonic Hd Integrated Camera Aw He2_adv Operating Instructions